Image not available
Illustrative purposes only
VSBU-120-D524A
AC/DC Open Frame Power Supply (PSU), ITE, 2 Output, 120 W, 90V AC to 260V AC, Fixed
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CUI
- Product type: AC / DC Open Frame Power Supplies
- SVHC: Lead (21-Jan-2025)
- Product Range: VSBU-120-D Series
- No. of Outputs: 2 Output
- Input Voltage VAC: 90V AC to 260V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 15A
- Output Current - Output 2: 3.5A
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: 24VDC
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 120W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 107.65 € |
| Current stock | 25+ |
| Lead time | 30 days |
Additional Resources: Product Page | 3D Model **date** 09/24/2020 **page** 1 of 4 ## **SERIES:** VSBU-120-D **DESCRIPTION:** AC-DC POWER SUPPLY **│** ## **FEATURES** - up to 120 W continuous power - industry standard 3” x 5” footprint - universal input 90~260 Vac - dual output - active power correction - internal EMI filter - no minimum load required - input surge current, over voltage, over load, and over current protections - UL/cUL and TUV safety approvals - efficiency 80% ## RoHS > |RoHS<br>><br>Abs|CES|CES||||| |---|---|---|---|---|---|---| |**MODEL**||**output**<br>**voltage**|**output**<br>**current**|**output**<br>**power**|**ripple and**<br>**noise**|**efficiency**| ||||**max**|**max**|**max**|**typ**| |||(Vdc)|(A)|(W)|(mVp-p)|(%)| |VSBU-120-D305|Vo1<br>Vo2|3.3<br>5|15<br>6|79.5<br>79.5|66<br>50|80<br>80| |VSBU-120-D312|Vo1<br>Vo2|3.3<br>12|15<br>6|120<br>120|66<br>120|80<br>80| |VSBU-120-D512|Vo1<br>Vo2|5<br>12|15<br>6|120<br>120|50<br>120|80<br>80| |VSBU-120-D515|Vo1<br>Vo2|5<br>15|15<br>6|120<br>120|50<br>150|80<br>80| |VSBU-120-D524A|Vo1<br>Vo2|5<br>24|15<br>3.5|120<br>120|50<br>240|80<br>80| |VSBU-120-D524B|Vo1<br>Vo3|5<br>-24|15<br>2|120<br>120|50<br>-240|80<br>80| |VSBU-120-D285|Vo1<br>Vo3|28<br>5|3.92<br>2|120<br>120|280<br>50|80<br>80| ## **PART NUMBER KEY** ## **VSBU-120 -DXXXXX - X** Base Number Output Voltage Power Fail Detect “Blank” = No P = Yes **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VSBU-120-D **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 09/24/2020 **│ page** 2 of 4 |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |voltage||90||260|Vac| |frequency||47||63|Hz| |current|at 115 Vac, full load<br>at 230 Vac, full load|||1.7<br>1.0|A<br>A| |inrush current|at 115 Vac, 25°C, full load, cold start<br>at 230 Vac, 25°C, full load, cold start||30<br>65|37<br>75|A<br>A| |power factor correction|full load at 90 ~ 260 Vac|0.95|0.97|1.0|| ## **OUTPUT** |**OUTPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |line regulation|full load||0.5|1|%| |load regulation|at 230 Vac||3|5|%| |temperature coefcient|all output|-0.04||0.04|%/°C| |transient response|full load to half load at 100 Vac|||4|ms| |start-up|full load at 100 Vac|0.3|1|2|s| |hold-up|full load at 110 Vac|16|||ms| |**PROTECTIONS**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |over voltage protection||112||132|%| |over current protection||110||150|%| |**SAFETY & COMPLIANCE**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |isolation voltage|primary to secondary<br>primary to earth ground|4,242<br>2,121|||Vdc<br>Vdc| |isolation resistance|test voltage of 500 Vdc|50|||MΩ| |safety approvals|UL 60950-1 2nd edition, EN 60950-1 2nd edition||||| |EMI/EMC|CISPR 22 class B, FCC part-15 class B||||| |leakage current|full load at 240 Vac||0.4|0.75|mA| |RoHS compliant|yes||||| |MTBF|MIL-HDSK-217F, 25°C ambient|100,000|||hrs| |**ENVIRONMENTAL**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature||0||70|°C| |storage temperature||-40||85|°C| |operating humidity|non-condensing|5||95|%| |storage humidity||0||75|%| **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VSBU-120-D **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 09/24/2020 **│ page** 3 of 4 ## **DERATING CURVES** ## output power vs. ambient temperature **==> picture [204 x 121] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>50<br>40<br>20<br>0 10 20 30 40 50 60 70<br>Ambient Temperature (°C)<br>Load (%)<br>**----- End of picture text -----**<br> ## **MECHANICAL DRAWING** |un<br>tol|10.9 0.429<br>0.5<br>L<br>N<br>G<br>0.5<br>0.217<br>2.571<br>0.5<br>0.5<br>5.5<br>65.3<br>76.2 3.000<br>M3XP0.5(MOUNTING H<br>**CN1**<br>1<br>ac line<br>2<br>ac neutral<br>3<br>ground<br>ts: mm[inches]<br>erance: ±0.5mm|10.9 0.429<br>0.5<br>L<br>N<br>G<br>0.5<br>0.217<br>2.571<br>0.5<br>0.5<br>5.5<br>65.3<br>76.2 3.000<br>M3XP0.5(MOUNTING H<br>**CN1**<br>1<br>ac line<br>2<br>ac neutral<br>3<br>ground<br>ts: mm[inches]<br>erance: ±0.5mm|10.9 0.429<br>0.5<br>L<br>N<br>G<br>0.5<br>0.217<br>2.571<br>0.5<br>0.5<br>5.5<br>65.3<br>76.2 3.000<br>M3XP0.5(MOUNTING H<br>**CN1**<br>1<br>ac line<br>2<br>ac neutral<br>3<br>ground<br>ts: mm[inches]<br>erance: ±0.5mm|10.9 0.429<br>0.5<br>L<br>N<br>G<br>0.5<br>0.217<br>2.571<br>0.5<br>0.5<br>5.5<br>65.3<br>76.2 3.000<br>M3XP0.5(MOUNTING H<br>**CN1**<br>1<br>ac line<br>2<br>ac neutral<br>3<br>ground<br>ts: mm[inches]<br>erance: ±0.5mm|||0.560<br>14.2<br>0.5<br>0.5<br>20.3 0.799<br>27.6 1.087<br>0.5<br>5.7<br>0.5<br>0.224<br>0.5<br>27.6 1.087<br>20.3 0.799<br>0.5<br>13|||0.5<br>76.2 3.000<br>33.6 1.323<br>0.5|**CN2**<br>VSBU<br>VSBU<br>VSBU-|**CN2**<br>VSBU<br>VSBU<br>VSBU-|**CN2**<br>VSBU<br>VSBU<br>VSBU-|**CN2**<br>VSBU<br>VSBU<br>VSBU-| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||||||||||||||| ||||||0.5<br>5.000<br>127.0<br>4.551<br>115.6<br>0.5<br>OLES)X4<br>40.0 1<br>0|.575<br>.5||||||||| |||||||||||||||| ||||||30.8 1.213<br>0.5<br>4.0(MOUNTING HO|LES)X4||MAX<br>3.0||76.2|1|-120-DXXX<br>V2|-120-D285<br>N/C|120-D524B<br>N/C| ||||||||||||2|V2|N/C|N/C| ||||||||||||3|V1|V1|V1| ||||||||||||4|V1|V1|V1| |||**CN1**||||||||||||| ||1<br>2<br>|ac line<br>ac neutral<br>|||||||||5|V1|V1|V1| ||||||||||||6<br>7|V1<br>com|V1<br>com|V1<br>com| ||3|ground|||||||||8<br>9|com<br>com|com<br>com|com<br>com| ||||||note:<br>1. Input connector mates with Molex housing 09-50-3051 and<br>Molex 2478 series crimp terminal.||||||10|n/c|V3|V3| ||||||||||||11|com|com|com| ||||||||||||12|com|com|com| ||||||||||||13|n/c|n/c|n/c| 1. Input connector mates with Molex housing 09-50-3051 and Molex 2478 series crimp terminal. 2. Output connector mates with Molex housing 09-50-3131 and Molex 2478 series crimp terminal. *pin 13 for optional power fail detect **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VSBU-120-D **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 09/24/2020 **│ page** 4 of 4 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|11/19/2010| |1.01|applied new spec template|02/29/2012| |1.02|corrected model number|04/23/2012| |1.03|V-Infnitybrandingremoved|08/14/2012| |1.04|updated deratingcurve|02/12/2013| |1.05|updated output connectorpart number|09/24/2020| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [119 x 38] intentionally omitted <==** **Headquarters** 20050 SW 112th Ave. Tualatin, OR 97062 **800.275.4899** Fax 503.612.2383 **cui** .com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →