Image not available
Illustrative purposes only
VOFM-250C-15
AC/DC Open Frame Power Supply (PSU), Medical, 1 Output, 250W @ 8CFM, 150 W, 85V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CUI
- Product type: AC / DC Open Frame Power Supplies
- SVHC: Lead (21-Jan-2025)
- Product Range: VOFM-250C Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 16.7A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 15V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): 250W @ 8CFM
- Power Rating (Convection Cooling): 150W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 98.73 € |
| Current stock | 25+ |
| Lead time | 30 days |
Additional Resources: Product Page **date** 07/11/2024 **page** 1 of 6 ## **SERIES:** VOFM-250C **DESCRIPTION:** AC-DC POWER SUPPLY **│** ## **FEATURES** - universal input voltage (85 ~ 264 Vac) - operating temperature range -40~70 °C with derating - active power factor correction - certified to 60601 safety standards (2xMOPP) - suitable for safety class I or class II installations - over voltage, over current, over temperature, and short circuit protections - 12 V fan output - operating altitude 5,000 m - 300 W peak power capability |**MODEL**|**output**<br>**voltage**|**output**<br>**current1**|**output**<br>**power1**|**ripple**<br>**and noise2**|**efficiency3**| |---|---|---|---|---|---| |||**max**|**max**|**max**|**typ**| ||(Vdc)|(A)|(W)|(mVp-p)|**(%)**| |VOFM-250C-12|12|20.8|250|108|91| |VOFM-250C-15|15|16.7|250|135|91| |VOFM-250C-19|19|13.2|250|170|91| |VOFM-250C-24|24|10.4|250|210|92| |VOFM-250C-30|30|8.33|250|270|92| |VOFM-250C-36|36|6.94|250|300|93| |VOFM-250C-48|48|5.21|250|300|93| Notes: 1. 8 CFM forced air, 150 W max output power with natural convection. 2. At full load, nominal input, 20 MHz bandwidth oscilloscope, tip & barrel method, output terminated with 47 μF electrolytic and 0.1 μF ceramic capacitors. 3. Efficiency is measured at rated load, and nominal line. ## **PART NUMBER KEY** ## **- - VOFM 250C XX** Base Number Output Voltage **cui** .com Additional Resources: Product Page **CUI Inc │ SERIES:** VOFM-250C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 07/11/2024 **│ page** 2 of 6 ## **INPUT** |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |voltage||85|100~240|264|Vac| |frequency||47|50~60|63|Hz| |current|low line, at 100 Vac, full load<br>high line, at 240 Vac, full load||3.1<br>1.3||A<br>A| |inrush current|low line, at 100 Vac, full load, cold start, 25°C<br>high line, at 240 Vac, full load, cold start, 25°C|||20<br>40|A<br>A| |leakage current|at 240 Vac, 60 Hz||0.25||mA| |power factor correction|at full load|0.9||1|| |no load power consumption|||0.21||W| |**OUTPUT**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |line regulation4|at 100~120 Vac or 200~240 Vac, full load|||1|%| |load regulation5|||±3||%| |start-up time|at 100~240 Vac, full load||1||s| |hold-up time6|at 110 Vac, full load|||10|ms| |temperature coefcient||||±0.04|%/°C| |fan output voltage7|||7~12||Vdc| |fan output current|||0.5||A| Notes: 4. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. 5. Load regulation is defined by changing ±40% of measured output load from 60% rated load. 6. Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load and nominal line. 7. Temperature controlled fan output voltage: 7V-12V. 8. At factory, in 60% rated load condition, each output is checked to be within voltage accuracy. ## **PROTECTIONS** |**PROTECTIONS**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |over voltage protection|latching|112||132|%| |over current protection|auto recovery|120||150|%| |over temperature protection|auto recovery||||| |**SAFETY & COMPLIANCE**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |isolation voltage|input to output 10 mA max<br>input to ground 10 mA max|||4,000<br>1,500|Vac<br>Vac| |safety approvals|certifed to 60601-1||||| |safety class9|class I, II||||| |conducted emissions|EN 55011, EN55032 Class B||||| |radiated emissions|EN 55011, EN55032 Class B||||| |harmonic current|EN 61000-3-2, Class A, Class D||||| |ESD|IEC 61000-4-2 15 kV air discharge, 8 kV contact discharge, perf. Criteria A||||| |radiated immunity|IEC 61000-4-3, perf. Criteria A||||| |EFT/burst|IEC610000-4-4 Power line 2 kV, 5 or 100 kHz, perf.|Criteria A|||| |surge|IEC 61000-4-5 1 kV line to neutral, 2 kV line to PE,|neutral to PE, perf. Criteria A|||| |conducted immunity|IEC 61000-4-6 3 Vrms, 6 Vrms, perf. Criteria A||||| |PFMF|IEC 61000-4-8 30 A/m, 50 Hz, perf. Criteria A||||| ||IEC 61000-4-11 100% reduction for 0.5 cycle at 50|Hz, perf. Criteria|A||| |voltage dips|IEC 61000-4-11 100% reduction for 1 cycle at 50 Hz, perf. Criteria A||||| ||IEC 61000-4-11 30% reduction for 25/30 cycles at 50/60 Hz, perf. Criteria A||||| |voltage interruptions|IEC 61000-4-11, 100% reduction for 250/300 cycles at 50/60 Hz, perf. Criteria B||||| **cui** .com Additional Resources: Product Page **CUI Inc │ SERIES:** VOFM-250C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 07/11/2024 **│ page** 3 of 6 ## **SAFETY & COMPLIANCE (CONTINUED)** |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |---|---|---|---|---|---| |MTBF|as per MIL-HDBK-217F at 25°C|300,000|||hours| |RoHS|yes||||| Notes: 9. Safety Class II operation may require external EMI/EMC components. ## **ENVIRONMENTAL** |**ENVIRONMENTAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature|see derating curves|-40||70|°C| |storage temperature|10~95% RH|-40||85|°C| |operating humidity|non-condensing|0||95|%| |storage humidity|non-condensing|0||95|%| |vibration|10~500 Hz, 10 min/1 cycle, 60 min. each along X, Y, Z axes|10~500 Hz, 10 min/1 cycle, 60 min. each along X, Y, Z axes||5|g| |altitude||||5,000|m| ## **DERATING CURVES** **cui** .com Additional Resources: Product Page **CUI Inc │ SERIES:** VOFM-250C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 07/11/2024 **│ page** 4 of 6 ## **DERATING CURVES (CONTINUED)** **cui** .com Additional Resources: Product Page **CUI Inc │ SERIES:** VOFM-250C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 07/11/2024 **│ page** 5 of 6 ## **MECHANICAL** |**MECHANICAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |dimensions|50.8 × 101.6 × 32.5 [2.00 x 4.00 x 1.28 inch]||||mm| |weight|||200||g| |cooling|natural convection or 8 CFM forced air||||| ## **MECHANICAL DRAWING** units: mm [inch] screw size diameter: 2.9 mm (min) |PIN CONNECTIONS|PIN CONNECTIONS|PIN CONNECTIONS| |---|---|---| |Connector|PIN|Function| |P1|L|Line| |P1|N|Neutral| |P1|G|Ground or<br>PE| |P2|1|+Vout| |P2|2|+Vout| |P2|3|+Vout| |P2|4|-Vout| |P2|5|-Vout| |P2|6|-Vout| |P3|1|Vfan| |P3|2|RTN| **cui** .com Additional Resources: Product Page **CUI Inc │ SERIES:** VOFM-250C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 07/11/2024 **│ page** 6 of 6 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|07/11/2024| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [119 x 38] intentionally omitted <==** **Headquarters** 15575 SW Sequoia Pkwy #100 Portland, OR 97224 **800.275.4899** Fax 503.612.2383 **cui** .com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →