Image not available
Illustrative purposes only
VMS-180C-12
AC/DC Open Frame Power Supply (PSU), 120 to 370VDC, Household & Medical, 1 Output, 180 W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CUI
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: VMS-180C Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 15A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Household & Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 180W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 51.83 € |
| Current stock | 10+ |
| Lead time | 30 days |
Additional Resources: Product Page | 3D Model **date** 06/15/2021 **page** 1 of 7 ## **SERIES:** VMS-180C **DESCRIPTION:** AC-DC POWER SUPPLY **│** ## **FEATURES** - universal input voltage (85 ~ 264 Vac) - active power factor correction - certified to 60601, 60335, and 61558 safety standards - suitable for safety class I or class II installations - over voltage, over current, over temperature, and short circuit protections - adjustable output via trim POT - low leakage current (< 0.1 mA) - low standby power consumption (0.5 W) |TAL|C€|||||| |---|---|---|---|---|---|---| |**MODEL**||**output**<br>**voltage**|**output**<br>**current**|**output**<br>**power**|**ripple**<br>**and noise2**|**efficiency3**| |||**range1**|**max**|**max**|**max**|**typ**| ||(Vdc)|(Vdc)|(A)|(W)|(mVp-p)|**(%)**| |VMS-180C-12|12|11.8 ~ 12.6|15.0|180|60|93| |VMS-180C-15|15|14.7 ~ 15.8|12.0|180|100|93| |VMS-180C-24|24|23.5 ~ 25.2|7.50|180|100|94| |VMS-180C-27|27|26.5 ~ 28.4|6.66|180|100|94| |VMS-180C-36|36|35.2 ~ 37.8|5.00|180|100|94| |VMS-180C-48|48|47.1 ~ 50.4|3.75|180|100|94| Notes: 1. When adjusting the output voltage care should be taken never to exceed the stated output power or output current of the unit. 2. At full load, nominal input, 20 MHz bandwidth oscilloscope, tip & barrel method, output terminated with 10 uF electrolytic and 0.1 uF ceramic capacitors. Under light load conditions (<15%) the measurement may double in an effort to maximize converter efficiency. 3. At 230 Vac. ## **PART NUMBER KEY** ## **- - - VMS 180C XX XXX** Base Number Output Voltage Chassis: “blank” = open-frame CNF = covered **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VMS-180C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 06/15/2021 **│ page** 2 of 7 |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |voltage|ac input<br>dc input|85<br>120||264<br>370|Vac<br>Vdc| |frequency||47||63|Hz| |current|at 115 Vac<br>at 230 Vac|||3.0<br>2.0|A<br>A| |inrush current|at 115 Vac, cold start<br>at 230 Vac, cold start||40<br>75||A<br>A| |leakage current|at 240 Vac|||0.1|mA| |power factor correction|at 115 Vac, full load<br>at 230 Vac, full load|0.99<br>0.95|||| |no load power consumption|||0.5||W| |**OUTPUT**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||12 Vdc output model|||6,000|μF| ||15 Vdc output model|||5,000|μF| |output capacitance|24 Vdc output model<br>27 Vdc output model|||3,200<br>2,400|μF<br>μF| ||36 Vdc output model|||2,000|μF| ||48 Vdc output model|||1,600|μF| |initial set point accuracy|full load||±1||%| |line regulation|rated load||±0.5||%| |load regulation|0 ~ 100% load||±0.5||%| |hold-up time|at 230 Vac, 25°C||12||ms| |temperature coefcient|||±0.03||%/°C| |fan power|15 Vdc output models, 6W max<br>other output models, 6W max|20.4<br>10.2|24<br>12|27.6<br>13.8|V<br>V| |**PROTECTIONS**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||output shutdown, latching||||| ||12 Vdc output model||16||Vdc| ||15 Vdc output model||20||Vdc| |over voltage protection|24 Vdc output model||32||Vdc| ||27 Vdc output model||35||Vdc| ||36 Vdc output model||50||Vdc| ||48 Vdc output model||60||Vdc| |over current protection|hiccup, auto recovery|110|||%| |short circuit protection|continuous, auto recovery, hiccup||||| |over temperature protection|output shutdown, auto recovery||||| **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VMS-180C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 06/15/2021 **│ page** 3 of 7 ## **SAFETY & COMPLIANCE** |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |---|---|---|---|---|---| ||input to ground for 1 minute; <10 mA|1,500|||Vac| |isolation voltage|input to output for 1 minute; <10 mA|4,000|||Vac| ||output to ground for 1 minute; <10 mA|1,500|||Vac| |safety approvals|certifed to 60601: ES, EN<br>certifed to 60335: EN<br>certifed to 61558: EN||||| |safety class|class I (with PE), class II (without PE)||||| |conducted emissions1|CISPR32/EN55032 CLASS B||||| |radiated emissions1|CISPR32/EN55032 (Class B for safety class I installations; Class||A for safety class II installations)||| |harmonic current|IEC/EN61000-3-2 CLASS D||||| |ESD|IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV perf. Criteria A||||| |radiated immunity|IEC/EN 61000-4-3 10V/m perf. Criteria A||||| |EFT/burst|IEC/EN 61000-4-4 ±4KV perf. Criteria A||||| |surge|IEC/EN 61000-4-5 ±2KV/±4KV perf. Criteria A||||| |conducted immunity|IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A||||| |voltage dips and interruptions|IEC/EN61000-4-11 0%, 70% perf. Criteria B||||| |MTBF|as per MIL-HDBK-217F|300,000|||hours| |RoHS|yes||||| |Notes:<br>1. The power supply is considered a component of the end system. All EMC performance has been tested on a metal plate with the dimensions 360 x 360|||||x 1 mm.| |The power supply must be|integrated into the end system for proper electromagnetic compatibility testing.||||| ## **ENVIRONMENTAL** |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |---|---|---|---|---|---| |operating temperature|see derating curves|-40||70|°C| |storage temperature||-40||85|°C| |operating humidity|non-condensing|20||90|%| |storage humidity|non-condensing|10||95|%| **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VMS-180C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 06/15/2021 **│ page** 4 of 7 ## **DERATING CURVES** Note: With an AC input voltage between 85 ~ 115 and a DC input between 120 ~ 160 Vdc the output power must be derated as per the temperature derating curve. ## **EFFICIENCY CURVES** **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VMS-180C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 06/15/2021 **│ page** 5 of 7 ## **MECHANICAL** |**MECHANICAL**||||| |---|---|---|---|---| |**parameter**|**conditions/description**<br>**min**|**typ**|**max**|**units**| |dimensions|open frame models: 101.6 × 50.8 × 25.4 [4.0 x 2.0 x 1.0 inch]<br>covered models: 103.4 × 62.0 × 37.0 [4.070 x 2.440 x 1.456 inch]|||mm<br>mm| |weight|open frame models<br>covered models|175<br>260||g<br>g| |cooling|natural convection (no integrated fan)|||| ## **MECHANICAL DRAWING** ## **Open-frame** units: mm [inch] general tolerance: ±1.00 [±0.039] |PIN-OUT|PIN-OUT|PIN-OUT|PIN-OUT| |---|---|---|---| |PIN|Function|Product<br>Connector|Customer Connector| |1|AC (N)/DC-|JST B3P-VH<br>or equivalent|Housing: JST VHR<br>Contact:JST SVH-21T-P1.1or<br>equivalent| |2|NC||| |3|AC (L)/DC+||| |4|Fan-|JST B2B-PH-K-S<br>or equivalent|Housing: JST PHR-2<br>Terminal: JST SPH-002T-P0.5S<br>or equivalent| |5|Fan+||| |6,7,8|-Vo|JST B6P-VH<br>or equivalent|Housing: JST VHR<br>Contact:JST SVH-21T-P1.1or<br>equivalent| |9,10,11|+Vo||| |Position|Screw Spec.|L<br>(recommended)|Torque| |---|---|---|---| |1 ~ 4|M3|6mm|0.4 N·m| |Note: 1. Class I system 1, 3 positions must be connected to the protective earth ground ( ).<br>2. Class II system 1, 3 positions must be connected together.<br>lore)<br>ore)<br>©|||| **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VMS-180C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 06/15/2021 **│ page** 6 of 7 ## **MECHANICAL DRAWING (CONTINUED)** ## **Covered** units: mm [inch] general tolerance: ±1.00 [±0.039] |PIN-OUT|PIN-OUT|PIN-OUT|PIN-OUT| |---|---|---|---| |PIN|Function|Product<br>Connector|Customer Connector| |1|AC (N)/DC-|JST B3P-VH<br>or equivalent|Housing: JST VHR<br>Contact:JST SVH-21T-P1.1<br>or equivalent| |2|NC||| |3|AC (L)/DC+||| |4|Fan-|JST B2B-PH-K-S<br>or equivalent|Housing: JST PHR-2<br>Contact:JST SPH-002T-P0.5S<br>or equivalent| |5|Fan+||| |6,7,8|-Vo|JST B6P-VH<br>or equivalent|Housing: JST VHR<br>Contact:JST SVH-21T-P1.1<br>or equivalent| |9,10,11|+Vo||| |iin|\_@a.50|Position<br>Screw Spec.<br>L<br>(recommended)<br>Torque<br> [20.138]| |---|---|---| |||1 ~ 2<br>M3<br>4mm<br>0.4 N·m<br>3 ~ 4<br>M3<br>3mm<br>0.4 N·m<br>Note: 1. Safety Class I integrations require the metal case to be securely fastened to protective<br>earth ground ( ).<br>~~POO |~~<br>~~POO |~~<br>an)| **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VMS-180C **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 06/15/2021 **│ page** 7 of 7 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|06/08/2021| |1.01|OVP updated|06/15/2021| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [119 x 38] intentionally omitted <==** **Headquarters** 20050 SW 112th Ave. Tualatin, OR 97062 **800.275.4899** Fax 503.612.2383 **cui** .com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →