- Manufacturer: CUI
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 12 |
| Price | 198.42 € |
| Current stock | 10+ |
| Lead time | 30 days |
**date** 08/27/2024 **page** 1 of 11 ## **SERIES:** VGS-500B **DESCRIPTION:** AC-DC POWER SUPPLY **│** ## **FEATURES** - 500 W continuous output power - peak power of 600 W for 5 seconds - certified to UL/EN 62368 - designed to meet EIC/EN 60335-1 - 3” x 5” footprint - active PFC - temperature range -40 °C to 85 °C with derating - operating altitude up to 5000 m - short-circuit, over-current, over-voltage & over-temperature protection - 12 V, 0.5 A fan supply - 5 V, 1 A standby supply - remote on/off - remote output voltage sensing - parallel output operation |**MODEL**|**output**<br>**voltage**|**output**<br>**current1**|**output**<br>**power**|**ripple**<br>**and noise2**|**efficiency3**| |---|---|---|---|---|---| ||**typ**|**max**|**max**|**max**|**typ**| ||(Vdc)|(A)|(W)|(mVp-p)|**(%)**| |VGS-500B-12|12|41.67|500|120|92.5| |VGS-500B-18|18|27.78|500|150|93.5| |VGS-500B-24|24|20.83|500|150|94.5| |VGS-500B-28|28|17.86|500|200|94.5| |VGS-500B-30|30|16.67|500|200|94.5| |VGS-500B-36|36|13.89|500|200|94.5| |VGS-500B-48|48|10.42|500|250|94.5| - Notes: 1. With 21 CFM of forced air cooling 2. At full load, nominal input, 20 MHz bandwidth oscilloscope, output terminated with 10 μF electrolytic and 0.1 μF ceramic capacitors. 3. Efficiency is measured at full load, and 230 Vac input. 4. All specifications are typical at nominal input, full load at 25°C unless otherwise noted. ## **PART NUMBER KEY** ## **- - - VGS 500B XX XX** Base Number Output Voltage Chassis: “blank” = vertical terminal H = horizontal terminal PC = parallel control and vertical terminal **cui** .com **CUI Inc │ SERIES:** VGS-500B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 08/27/2024 **│ page** 2 of 11 |**INPUT**|| |---|---| |**parameter**|**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**| |voltage|80<br>100~240<br>264<br>Vac| |frequency|47<br>50~60<br>63<br>Hz| |current|at full load, 100 Vac input<br>6<br>A| |inrush current|at 240 Vac, cold start at 25 °C<br>8.5<br>A| |leakage current|earth<br>touch<br>0.3<br>0.1<br>mA<br>mA| |power factor correction|at 230 Vac input<br>0.97| |no load power consumption|0.5<br>W| |**OUTPUT**|| |**parameter**|**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**| |line regulation|high line to full line<br>±0.5<br>%| |load regulation|10 % to 100 % load<br>±1<br>%| |output voltage set point|at 80 Vac ~ 264 Vac input (see derating curve)<br>12 Vdc output model<br>18 Vdc output model<br>24 Vdc output model<br>28 Vdc output model<br>30 Vdc output model<br>36 Vdc output model<br>48 Vdc output model<br>11.88<br>17.82<br>23.76<br>26.6<br>28.5<br>35.64<br>47.52<br>12<br>18<br>24<br>28<br>30<br>36<br>48<br>12.12<br>18.18<br>24.24<br>29.4<br>31.5<br>36.36<br>48.48<br>Vdc<br>Vdc<br>Vdc<br>Vdc<br>Vdc<br>Vdc<br>Vdc| |hold-up time|at 115 Vac, full load<br>16<br>ms| |adjustability|via Vadj trim pot (see mechanical drawing)<br>±5<br>%| |peak power5|at 115 Vac & 230 Vac, full load, 25 °C<br>120<br>%| |current sharing accuracy|50 % to 100 % load<br>±5<br>%| |PS on signal6|power on<br>power of (PS on, GND open)<br>0<br>4<br>2<br>Vdc<br>Vdc| ||power on (PS on, GND short)<br>power of (PS on, GND open)<br>10<br>0<br>mA<br>mA| |PF signal|at 80 Vac to 264 Vac, full load<br>TTL high after power set up<br>100<br>500<br>ms| ||at 80 Vac to 264 Vac, full load<br>TTL low before Vo is below 90% of rated value<br>1<br>10<br>ms| |switching frequency|at maximum rated power<br>65<br>kHz| |fan output voltage7|12 Vdc / 0.5 A<br>12<br>Vdc| |standby|5 Vdc / 1 A (forced air & convection cooling)| Notes: 5. Peak power should be less than 5 seconds, with a maximum 10 % duty cycle, peak power function by 120% load 5 seconds and 75% load 45 seconds. 6. Absolute maximum rating: 60V. 7. Fan output can only operate normal when the stand-by output is above 0.5A. ## **PROTECTIONS** |**PROTECTIONS**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||latching (ac recycle to reset)||||| ||12 Vdc output model|||16|Vdc| |over voltage protection|18 Vdc output model<br>24, 28, 30 Vdc output models|||30<br>35|Vdc<br>Vdc| ||36 Vdc output model|||50|Vdc| ||48 Vdc output model|||63|Vdc| |over current protection|auto recovery|120||190|%| |short circuit protection|auto recovery||||| **cui** .com **CUI Inc │ SERIES:** VGS-500B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 08/27/2024 **│ page** 3 of 11 over temperature protection auto recovery ## **SAFETY & COMPLIANCE** |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |---|---|---|---|---|---| ||at 115 Vac & 230 Vac, full load, 25 °C||||| ||12 Vdc output model|||42,900|µF| ||18 Vdc output model|||28,600|µF| |capacitive load|24 Vdc output model<br>28 Vdc output model|||20,800<br>18,000|µF<br>µF| ||30 Vdc output model|||16,600|µF| ||36 Vdc output model|||14,000|µF| ||48 Vdc output model|||10,800|µF| ||input to output 1 minute|||4,000|Vac| |isolation voltage|input to ground 1 minute|||1,800|Vac| ||output to ground for 1 minute|||1,800|Vac| |safety approvals|certifed to 62368-1: UL, EN||||| |safety class|class I||||| ||EN 55032:2015+AC:2016, EN 61000-6-3 2007+A1: 2011+AC: 2012, Class B||||| |EMI/EMC|EN 61000-6-4:2007+A1:2011, 47 CFR FCC Part 15 Subpart B (Class B)||||| ||EN 61204-3:2000, EN 61000-3-2:2014, EN 61000-3-3:2013||||| |conducted emissions|EN 55032:2015+AC:2016, EN 61000-6-3 2007+A1: 2011+AC: 2012, Class B<br>EN 61000-6-4:2007+A1:2011, 47 CFR FCC Part 15 Subpart B (Class B)||||| |radiated emissions|EN 55032:2015+AC:2016, EN 61000-6-3 2007+A1: 2011+AC: 2012, Class B<br>EN 61000-6-4:2007+A1:2011, 47 CFR FCC Part 15 Subpart B (Class B)||||| |ESD|IEC 61000-4-2:2008, air discharge: ±8 kV, contact discharge: ±4 kV, perf. Criteria A||||| |radiated immunity|IEC 61000-4-3:2006+A1:2007+A2:2010, perf. Criteria A||||| |EFT/burst|IEC 61000-4-4:2012, ±1 kV, ±2 kV, perf. Criteria A||||| |surge|IEC 61000-4-5:2014+A1:2017, line to neutral: ±0.5 kV, ±1 kV, line to ground: ±0.5 kV, ± 1kV, ±2 kV,<br>perf. Criteria A||||| |conducted immunity|IEC 61000-4-6:2013+COR1:2015, perf. Criteria A||||| |PFMF|IEC 61000-4-8:2009, perf. Criteria A||||| |voltage dips|IEC 61000-4-11:2004+A1:2017, dip: 30 % reduction, dip > 95 % reduction, perf. Criteria A||||| |voltage interruptions|IEC 61000-4-11:2004+A1:2017, > 95 % reduction, perf. Criteria B||||| |MTBF|as per MIL-HDBK-217F at 25°C||200,000||hours| |RoHS|yes||||| |**ENVIRONMENTAL**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature|see derating curves|-40||85|°C| |maximum case temperature|center of the base plate|-40||85|°C| |storage temperature||-40||85|°C| |operating humidity|non-condensing|0||93|%| |shock|MIL-STD-810F table 516.5, table 516.5-I, 10ms,<br>each axis 3 times (±X, ±Y, ±Z axes)||75||g| |vibration|MIL-STD-810F table 514.5C-VIII, 15~2000 Hz,<br>X, Y, Z axes, 1 hour (each axis), total 3 hours||4||g| |altitude||||5,000|m| **cui** .com **CUI Inc │ SERIES:** VGS-500B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 08/27/2024 **│ page** 4 of 11 ## **DERATING CURVES** **cui** .com **CUI Inc │ SERIES:** VGS-500B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 08/27/2024 **│ page** 5 of 11 ## **DERATING CURVES (CONTINUED)** **cui** .com **CUI Inc │ SERIES:** VGS-500B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 08/27/2024 **│ page** 6 of 11 ## **DERATING CURVES (CONTINUED)** ## **EFFICIENCY CURVES** **cui** .com **CUI Inc │ SERIES:** VGS-500B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 08/27/2024 **│ page** 7 of 11 ## **EFFICIENCY CURVES (CONTINUED)** **cui** .com **CUI Inc │ SERIES:** VGS-500B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 08/27/2024 **│ page** 8 of 11 ## **MECHANICAL** |**MECHANICAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |dimensions|5.354 x 3.425x 1.673 inches [136.00 x 87.00 x 42.50 mm]||||inch| |weight|||635||g| ## **MECHANICAL DRAWING** tolerance: inches: x.xxx = ±0.02 iii ii mm: x.xx = ±0.5 |AC input connector (CN1): JST B2P3-VH or equivalent|AC input connector (CN1): JST B2P3-VH or equivalent|AC input connector (CN1): JST B2P3-VH or equivalent|AC input connector (CN1): JST B2P3-VH or equivalent| |---|---|---|---| |PIN|Function|Mating Housing|Terminal| |1|AC (L)|JST VHR-3N<br>or equivalent|JST SVH-41T-P1.1<br>or equivalent| |2|-||| |3|AC (N)||| |DC Output Connector (CN2): TKP P110I-04 or equivalent|DC Output Connector (CN2): TKP P110I-04 or equivalent|DC Output Connector (CN2): TKP P110I-04 or equivalent|DC Output Connector (CN2): TKP P110I-04 or equivalent| |---|---|---|---| |PIN|Function|Mating Housing|Terminal| |1|GND|JST PHR-4<br>or equivalent|JST SPH-002T-P0.5L<br>or equivalent| |2|+5VSB||| |3|GND||| |4|+12V FAN||| |DC Output Connector (CN3):TKP P110L-07 or equivalent|DC Output Connector (CN3):TKP P110L-07 or equivalent|DC Output Connector (CN3):TKP P110L-07 or equivalent|DC Output Connector (CN3):TKP P110L-07 or equivalent| |---|---|---|---| |PIN|Function|Mating Housing|Terminal| |1|GND|JST PHR-7<br>or equivalent|JST SPH-002T-P0.5L<br>or equivalent| |2|PF||| |3|FAN-EN||| |4|PS-ON||| |5|-Sense||| |6|+Sense||| |7|NC or PC<br>(option)||| Note: Pin 7 is PC only in models with parallel control and vertical terminal. |DC Output Connector: KANG YANG PCB-58M4<br>or equivalent|DC Output Connector: KANG YANG PCB-58M4<br>or equivalent| |---|---| |Function|Screw Locked Torque| |-Vo|M4 7KFG-CM| |+Vo|| Note: If the jumper on pins 3 & 4 is removed and replaced incorrectly or not at all, issues affecting the function of the part may arise. **cui** .com **CUI Inc │ SERIES:** VGS-500B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 08/27/2024 **│ page** 9 of 11 ## **PS ON/OFF REMOTE CONTROL AND FAN CONTROL** The PS-ON remote control is provided in CN3 pin 4. The diagram and control function are shown as follow: Power ON: VPS-ON ≤ 2 V, IPS-ON ≥ 10 mA (PS-ON and GND short, IPS-ON = 10 mA typical) Power OFF: Open circuit, VPS-ON = 4V ## **Figure 1** The fan control is provided in CN3 pin 3. The control function and diagram are shown as follow: Fan ON: VFAN-EN ≥ 1 V Fan OFF: Open circuit, VFAN-EN = 0 ## **Figure 2** When the PS-ON remote control function is not used,connect a short circuit between the pin PS-ON and FAN-EN. **Figure 3** Note: Product is supplied with remote control and fan control disabled via a jumper between PS-ON and FAN-EN (see Figure 3). To use these functions remove jumper and refer to Figures 1 and 2. **cui** .com **CUI Inc │ SERIES:** VGS-500B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 08/27/2024 **│ page** 10 of 11 ## **PARALLEL CONTROL AND CURRENT SHARING** The optional PC pin may be used to connect multiple power supplies in parallel for current sharing (see Figure 4). For proper operation, only power supplies with the same output voltage should be connected in parallel[1] , the total output power should be limited to 90% of the total rated power[2] , and the remote sensing feature should not be utilized[3] . For reliable operation, it is also suggested that the remote on/off feature be used to synchronize the outputs during turn on and turn off. ## **Figure 4 Connection diagram for parallel operation and current sharing** Notes: 1. Output voltage of all power supplies should be within 0.2 V of each other at no load. - ii 2. Total output power ≤ Po,rated x N x 0.9. - ii 3. Leave +Sense and -Sense pins open when current sharing. ii 4. It is recommended to use the PS-ON pin to enable/disable the power supplies output when current sharing. See Figure 4. **cui** .com **CUI Inc │ SERIES:** VGS-500B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 08/27/2024 **│ page** 11 of 11 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|08/16/2024| |1.01|parallel control & adjustabilityadded|08/27/2024| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [119 x 38] intentionally omitted <==** **Headquarters** 15575 SW Sequoia Pkwy #100 Portland, OR 97224 **800.275.4899** Fax 503.612.2383 **cui** .com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →