Image not available
Illustrative purposes only
VGS-200E-24
AC/DC Enclosed Power Supply (PSU), ITE, Industrial & Household, 1 Outputs, 201.6 W, 24 VDC, 8.4 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CUI
- Product type: AC / DC Enclosed Power Supplies
- SVHC: To Be Advised
- Product Range: VGS-200E Series
- No. of Outputs: 1Outputs
- Output Power Max: 201.6W
- Input Voltage VAC: 85V AC to 305V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 8.4A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Household
| Delivery and price | |
|---|---|
| Units per pack | 26 |
| Price | 66.69 € |
| Current stock | 10+ |
| Lead time | 30 days |
Additional Resources: Product Page | 3D Model **date** 10/17/2023 **page** 1 of 7 ## **SERIES:** VGS-200E **DESCRIPTION:** AC-DC POWER SUPPLY **│** ## **FEATURES** - 200 W continuous switching power supply - 85 ~ 305 Vac, 120 ~ 430 Vdc input voltage - adjustable output voltage - EN/UL/BS EN 62368-1 - designed to meet EN 60335, EN 61558, GB 4943 - CISPR32/EN55032 CLASS B compliant - temperature range -40 °C ~ +70 °C with derating - baseplate cooling - over-temperature, output over-voltage, over-current, short-circuit protection - over-current & short-circuit protection delay - 5,000 m operating altitude - accepts AC or DC input (dual-use of same terminal) **==> picture [29 x 29] intentionally omitted <==** **----- Start of picture text -----**<br> RoHS<br>~<br>**----- End of picture text -----**<br> |**MODEL**||**output**<br>**voltage**|**output**<br>**current**|**output**<br>**power**|**ripple**<br>and noise’|**efficiency2**| |---|---|---|---|---|---|---| ||**typ**<br>(Vdc)|**range**<br>(Vdc)|**max**<br>(A)|**max**<br>(W)|**typ**<br>(mVp-p)|**typ**<br>(%)| |VGS-200E-5|5|4.5~5.5|40.0|200.0|200|91| |VGS-200E-12|12|11.4~12.6|16.7|200.4|240|93| |VGS-200E-24|24|22.8~25.2|8.4|201.6|240|94| |VGS-200E-36|36|34.2~37.8|5.6|201.6|240|94| |VGS-200E-48|48|45.6~50.4|4.2|201.6|300|94| Note: i 1. Ripple and noise are measured at 20 MHz BW with 47 uF aluminum electrolytic capacitor and 0.1 uF ceramic capacitor on the output. 2. Measured at 230 Vac. ii 3. Unless otherwise specified, the parameters in this datasheet were measured under the conditions of Ta=25°C, humidity<75% RH with nominal input voltage and rated output load. ## **PART NUMBER KEY** ## **VGS-200E - XX** Base Number Output Voltage **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VGS-200E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/17/2023 **│ page** 2 of 7 ## **INPUT** |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |voltage range|ac input<br>dc input|85<br>120||305<br>430|Vac<br>Vdc| |frequency range||47||63|Hz| |current|at 115 Vac<br>at 230 Vac|||2.5<br>1.2|A<br>A| |inrush current|at 115 Vac, cold start<br>at 230 Vac, cold start||40<br>80||A<br>A| |leakage current|at 240 Vac|||0.5|mA| |power factor|at 115 Vac, full load<br>at 230 Vac, full load||0.98<br>0.95||| ## **OUTPUT** |**OUTPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||5 Vdc output model|||10,000|μF| ||12 Vdc output model|||8,000|μF| |capacitive load|24 Vdc output model|||5,000|μF| ||36 Vdc output model|||3,000|μF| ||48 Vdc output model|||2,000|μF| |initial set point acuracy|5 Vdc output model, full load range<br>all other models, full load range||±2<br>±1||%<br>%| |line regulation|5 Vdc output model, rated load<br>all other models,rated load||±0.5<br>±0.3||%| |load regulation|5 V model at 230 Vac, 0~100% load<br>all other models at 230 Vac, 0~100% load||±1<br>±0.5||%<br>%| |hold-up time|at 115 & 230 Vac, full load||10||ms| ## **PROTECTIONS** |**PROTECTIONS**|| |---|---| |**parameter**|**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**| |over current protection4|normal & high temperature, 230 Vac, rated load<br>105<br>200<br>%| ||low temperature, 230 Vac, rated load<br>105<br>%| |over voltage protection|5 Vdc output model, hiccup<br>12 Vdc output model, hiccup<br>24 Vdc output model, hiccup<br>36 Vdc output model, hiccup<br>48 Vdc output model, hiccup<br>6.3<br>16<br>35<br>47<br>60<br>Vdc<br>Vdc<br>Vdc<br>Vdc<br>Vdc| |short circuit protection5|5 Vdc output model<br>hiccup, constant current (200~300%Io) works 200ms, turn of 10s,<br>continuous, auto recovery| ||all other models<br>hiccup, constant current (200~300%Io) works 1s, turn of 10s,<br>continuous, auto recovery| |over temperature protection|output shutdown, auto recovery| Note: i 4. At 230 Vac, rated load. Delay time is 1s with auto recovery after the abnormality is removed. 5. Recovery time is 10s max after the short circuit disappears. **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VGS-200E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/17/2023 **│ page** 3 of 7 ## **SAFETY & COMPLIANCE** |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |---|---|---|---|---|---| ||input to output for 1 minute, 5 mA max|4,000|||Vac| |isolation voltage|input to ground for 1 minute, 5 mA max|2,000|||Vac| ||output to ground for 1 minute, 5 mA max|1,250|||Vac| ||certifed to 62368-16: UL, EN, BS EN||||| |safety approvals|designed to meet60335: EN<br>designed to meet61558: EN||||| ||designed to meet4943: GB||||| |safety class|Class I||||| |conducted emissions|CISPR32/EN55032 CLASS B||||| |radiated emissions|CISPR32/EN55032 CLASS B||||| |harmonic current|IEC/EN61000-3-2 CLASS A, CLASS C and CLASS D||||| |ESD|IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV, perf. Criteria A||||| |radiated immunity|IEC/EN 61000-4-3 10V/m, perf. Criteria A||||| |EFT/burst|IEC/EN 61000-4-4 ±4KV, perf. Criteria A||||| |surge|IEC/EN 61000-4-5 line to line ±2KV/line to ground|±4KV, perf. Criteria A|||| |conducted immunity|IEC/EN61000-4-6 10Vrms, perf. Criteria A||||| |voltage dips and interruption|IEC/EN61000-4-11 0%, 70%, perf. Criteria B||||| |intercom interference test|MS-SOP-DQC-007, perf. Criteria B||||| |RoHS compliant|yes||||| |MTBF|as per MIL-HDBK-217F at 25 °C|300,000|||hrs| Note: i6. Certification applies to 100~240 Vac applications. ## **ENVIRONMENTAL** |**ENVIRONMENTAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature|see derating curve|-40||70|°C| |storage temperature||-40||85|°C| |operating humidity|non-condensing|20||90|%| |storage humidity|non-condensing|10||95|%| |temperature coefcient|||0.03||%/°C| |**MECHANICAL**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |dimensions|194.00 x 55.00 x 26.00||||mm| |weight|||430||g| |cooling|natural convection||||| |case material|metal (AL6063, SGCC)||||| **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VGS-200E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/17/2023 **│ page** 4 of 7 ## **MECHANICAL DRAWING** units: mm [inches] tolerance: ±1.00 [±0.039] ADJ: Output voltage adjustable resistor. |PIN OUT|PIN OUT| |---|---| |PIN|Function| |1|+Vo| |2|+Vo| |3<br>~~oe~~|-Vo<br>~~oe~~| |4<br>~~oe~~|-Vo<br>~~oe~~<br>~~©~~| |5<br>~~oe~~|~~oe~~<br>~~©~~| |6<br>~~we~~|AC(N)<br>~~we~~| |7<br>~~we~~|AC(L)<br>~~we ~~| > Note: At least one position 1 ~ 4 OO. * > must be securely connected to the . © ## CONNECTOR WIRES RANGE |CONNECTOR WIRES RANGE|CONNECTOR WIRES RANGE|CONNECTOR WIRES RANGE|CONNECTOR WIRES RANGE|CONNECTOR WIRES RANGE| |---|---|---|---|---| ||Input<br>connector|Output connector<br>(single wire)|Output connector<br>(double wires)|Output connector<br>(double wires)| |5 V|22 ~ 14 AWG|not suggested|14 ~ 12 AWG|-Vodouble wires<br>+Vodouble wires| |12 V||14 ~ 12 AWG|18 ~ 12 AWG|| |24, 36, 48 V||18 ~ 12 AWG|20 ~ 12 AWG|| |Screw / Torque|M3.5,<br>Max 0.5 N·m|M3.5, Max 0.8 N·m||| **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VGS-200E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/17/2023 **│ page** 5 of 7 ## **INSTALATION DIAGRAM** |Position|Screw Spec.|L(suggested)|Torque(max)| |---|---|---|---| |1 ~ 4|M3|4 mm|0.4 N·m| Note: 6. In order to meet the “derating curve”, the product testing must be installed onto an aluminum plate. - The size of the suggested aluminum plate is shown as above. For optimizing thermal performance, it is necessary to apply thermal grease on the bottom of the product. 7. It is suggested to install the product with M3 x 5 combination screws, and the product must be firmly installed at the centre of the aluminum plate. **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VGS-200E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/17/2023 **│ page** 6 of 7 ## **DERATING CURVES** Note: 8. With an AC input voltage between 80 ~ 100 Vac and a DC input between 120 ~ 140 Vdc the output power must be derated as per the temperature derating curves. 9. This product is suitable for applications using natural convection. For applications in closed enviroment please consult CUI. ## **EFFICIENCY CURVES** **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** VGS-200E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/17/2023 **│ page** 7 of 7 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|10/17/2023| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [117 x 37] intentionally omitted <==** **Headquarters** 20050 SW 112th Ave. Tualatin, OR 97062 **800.275.4899** Fax 503.612.2383 **cui** .com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →