Image not available
Illustrative purposes only
VGS-150E-18-M2
AC-DC 150W 18V ENCLOSED TB
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CUI
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (04-Feb-2026)
| Delivery and price | |
|---|---|
| Units per pack | 40 |
| Price | 77.59 € |
| Current stock | 10+ |
| Lead time | 30 days |
**date** 07/07/2025 **page** 1 of 5 ## **SERIES:** VGS-150E **DESCRIPTION:** INTERNAL AC-DC POWER SUPPLY **│** ## **FEATURES** - 100 W with natural convection, 150 W with forced air cooling - 3”x2” compact size, industrial design - IEC/EN/UL 62368-1 certified - operating temperature -20°C to 70°C (with derating) - short-circuit protection, over power protection, overvoltage protection - main output power ON LED indicators - low no load power consumption (<0.150 W) - chassis mounting |**MODEL**|**output**<br>**voltage**|**output**<br>**current1**|**output**<br>**power1,2**|**ripple**<br>**and noise3**|**efficiency**<br>**level4**| |---|---|---|---|---|---| |||**max**|**max**|**typ**|**typ**| ||(Vdc)|(A)|(W)|(mVp-p)|**(%)**| |VGS-150E-12|12|12.5|150|120|92| |VGS-150E-15|15|10.0|150|150|92| |VGS-150E-18|18|8.34|150|180|92| |VGS-150E-24|24|6.25|150|240|92| |VGS-150E-28|28|5.36|150|280|92| |VGS-150E-36|36|4.17|150|360|92| |VGS-150E-48|48|3.13|150|360|92| |VGS-150E-54|54|2.78|150|360|92| - Notes: 1. With forced air (10 CFM). 2. Maximum output power is 150 W with 10 CFM forced air cooling, and 100 W with natural convection cooling. 3. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10µF electrolytic capacitor and a 0.1µF ceramic capacitor in parallel at output connector. 4. At full load, 230 Vac. ## **PART NUMBER KEY** ## **- - VGS 150E XX - XX** Base Number Output Voltage Output Connections: “blank” = 4-pin connector M2 = terminal block connector **cui** .com **CUI Inc │ SERIES:** VGS-150E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 07/07/2025 **│ page** 2 of 5 ## **INPUT** |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |voltage||90|115~230|264|Vac| |frequency||47|50~60|63|Hz| |current|at 115 Vac/50 Hz|||2|A| |inrush current|at 230 Vac, cold start|||100|A| |leakage current|earth<br>touch<br>at 264 Vac (Class I)<br>at 264 Vac (Class II)|||300<br>100|µA<br>µA| |no load power consumption||||0.15|W| |power factor||0.9|||| ## **OUTPUT** |**OUTPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||12 Vdc output model|||8.34 / 12.5|A| ||15 Vdc output model|||6.67 / 10.0|A| ||18 Vdc output model|||5.56 / 8.34|A| |output current|24 Vdc output model|||4.17 / 6.25|A| |(natural convection/forced air5)|28 Vdc output model|||3.58 / 5.36|A| ||36 Vdc output model|||2.78 / 4.17|A| ||48 Vdc output model|||2.09 / 3.13|A| ||54 Vdc output model|||1.86 / 2.78|A| |load regulation|12, 15, 18, 24, 28 Vdc output models<br>all other output models||±3<br>±2||%| |hold-up time||10|||ms| |transient response|10% to full load deviation recovery time <20mS 10% max||||| |overshoot|turn-on and turn-of overshoot shall not exceed ±10% of the voltage regulation tolerance||||| |switching frequency|at full load|75||90|kHz| |Notes:<br>5. With forced air 10 CFM.|||||| |**PROTECTIONS**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||12 Vdc output, output shut-down with latch|13.2||15.6|Vdc| ||15 Vdc output, output shut-down with latch|16.5||19.5|Vdc| ||18 Vdc output, output shut-down with latch|19.8||23.4|Vdc| |over voltage protection|24 Vdc output, output shut-down with latch<br>28 Vdc output, output shut-down with latch|26.4<br>30.8||31.2<br>36.4|Vdc<br>Vdc| ||36 Vdc output, output shut-down with latch|39.6||46.8|Vdc| ||48 Vdc output, output shut-down with latch|52.8||62.4|Vdc| ||54 Vdc output, output shut-down with latch|59.4||64.8|Vdc| |over current protection|auto-recovery|105||160|%| |short circuit protection|auto-recovery||||| |over temperature protection|latching type, power recycle||||| **cui** .com **CUI Inc │ SERIES:** VGS-150E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 07/07/2025 **│ page** 3 of 5 ## **SAFETY & COMPLIANCE** |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |---|---|---|---|---|---| ||input to output, for 4 seconds (Class I & II)|5,656|||Vdc| |isolation voltage|input to frame ground, for 4 seconds (Class I)|2,121|||Vdc| ||output to frame ground, for 4 seconds (Class I)|2,121|||Vdc| |safety approvals|certified to 62368-1: IEC/EN/UL||||| |safety class|Class I, Class II||||| |EMI/EMC|EN55032 Class B & EN55035<br>FCC Part 15 Class B||||| |MTBF|as per Telcordia (Bellcore TR-332) at 25°C|400,000|||hours| |RoHS|yes||||| |**ENVIRONMENTAL**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature||-20||70|°C| |storage temperature||-20||85|°C| |operating humidity|non-condensing|10||95|%| |storage humidity|non-condensing|0||95|%| |altitude||||5,000|m| ## **DERATING CURVE** **cui** .com **CUI Inc │ SERIES:** VGS-150E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 07/07/2025 **│ page** 4 of 5 ## **MECHANICAL** |**MECHANICAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |dimensions|90.6 x 64.0 x 39.2 [3.57 x 2.52 x 1.55 inch]||||mm| |weight|||210||g| |cooling|forced air 10 CFM||||| ## **MECHANICAL DRAWING** units: mm [inch] |**CN1**: Input Connector (pitch: 3.96mm)<br>JST B3P-VH-B or equivalent<br>Mates with JST VHR-3N or equivalent|**CN1**: Input Connector (pitch: 3.96mm)<br>JST B3P-VH-B or equivalent<br>Mates with JST VHR-3N or equivalent| |---|---| |PIN|Function| |1|AC(L)| |2|AC(N)| **CN2** : Main Output Connector (pitch: 3.96mm / 3.50mm) |**CN2**: Main Output Connector<br>(pitch: 3.96mm / 3.50mm)|**CN2**: Main Output Connector<br>(pitch: 3.96mm / 3.50mm)|**CN2**: Main Output Connector<br>(pitch: 3.96mm / 3.50mm)| |---|---|---| |JST B4P-VH-B or equivalent<br>Mates with JST VHR-4N or equivalent||Eurostyle P.C.B. 3.50mm Terminal Block<br>16-24 AWG (1.5mm2) Wire range| |PIN|Function|Function| |1|GND|GND| |2|GND|GND| |3|+Vout|+Vout| |4|+Vout|+Vout| ## **DC FAN Recommended Direction** **cui** .com **CUI Inc │ SERIES:** VGS-150E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 07/07/2025 **│ page** 5 of 5 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|07/07/2025| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [155 x 34] intentionally omitted <==** 15575 SW Sequoia Pkwy #100 Portland, OR 97224 800.275.4899 Fax 503.612.2383 Belfuse.com powersupport@belf.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →