VES90PS12
AC/DC Power Supply, ITE, 1 Output, 90 W, 12 VDC, 7.5 A
- Manufacturer: XP POWER
- Product type: AC / DC External Plug In Adaptor Power Supplies
- No. of Outputs:1 Output; Output Power Max:90W; Output Voltage - Output 1:12V; Output Current - Output 1:7.5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Connector:4 Way Mi
- SVHC: No SVHC (17-Jan-2023)
- Plug Type: Mains Plug Sold Separately
- Product Range: VES90 Series
- No. of Outputs: 1 Output
- Output Connector: 4 Way Mini DIN
- Output Power Max: 90W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 7.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 32.76 € |
| Current stock | 25+ |
| Lead time | 30 days |
VES90 series ## 90W **External desktop** **AC-DC power supplies** The 90W VES90 with Energy Efficiency Level VI and CoC Tier 2 these desktop/external ACDC power supplies are designed for high volume/low cost applications. With class I construction the VES90 are fitted with an IEC320-C14 inlet and have a voltage input range of 90 to 264VAC. The DC lead is fitted with a 4 pin power mini DIN connector as standard, alternatively a 5.5 x 2.5mm barrel jack connector can be specified as an option. **==> picture [538 x 67] intentionally omitted <==** **----- Start of picture text -----**<br> Features Applications Dimensions<br>f Single outputs from 12V to 48VDC 139.0 x 58.0 x 31.0mm (5.47" x 2.28" x 1.223")<br>f Energy efficiency level VI a<br>f European CoC tier 2 electronicsIndustrial Instrumentation Technology<br>**----- End of picture text -----**<br> - f <0.15W standby power - f China compulsory certification (CCC) qualified - f High power density - f Optional output connector - f 0°C to +60°C operation - f 1 year warranty **==> picture [139 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> Documentation<br>For further information click the link or scan<br>the code<br>: xppower.com<br>**----- End of picture text -----**<br> ## **Models & ratings** |Model number|Output voltage|Output current|Total regulation|Efficiency(1)|Output power| |---|---|---|---|---|---| |VES90US12|12.0VDC|7.50A|±5%|89%|90W| |VES90US19|19.0VDC|4.74A||89%|| |VES90US24|24.0VDC|3.75A||89%|| |VES90US48|48.0VDC|1.875A||89%|| Notes: 1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230VAC input. 2. For optional Barrel Jack Connector, 2.5mm inner positive, 5.5mm outer negative, 11mm length add suffix ‘-B’ e.g. VES90PS24-B. 1 [| **AC-DC power supplies** ## VES90 series **==> picture [32 x 31] intentionally omitted <==** ## **Input** **==> picture [553 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |**Characteristic**|**Minimum**|**Typical**|**Maximum**|**Units**|**Notes & conditions**| |---|---|---|---|---|---| ||||||| |Input voltage|90||264|VAC|| |Input frequency|47||63|Hz|| |Input current||1.5/0.6||A|Measured at 115/230VAC| |Inrush current|||130||230VAC, cold start at +25°C| |Power factor|EN61000-3-2 Class A<br>||||| |Earth leakage current|||3.5|mA|264 VAC, 60~~Hz~~| |No load input power|||0.15|W|| |Input protection<br>|T3.15A/250 VAC internal fuse in line||||| ## **Output** **==> picture [555 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristic|Minimum|Typical|Maximum|Units|Notes & conditions| |---|---|---|---|---|---| ||||||| |Output Voltage|12||48|VDC|See models & ratings| |Initial Set Accuracy|||±2|%|At 50% load| |Minimum Load<br>|No minimum load required||||| |Start Up Delay|||3|s|| |Start Up Rise Time|||50|ms|| |Hold Up Time|8/16|||ms|Full load and 115 VAC/230 VAC| |Line Regulation|||±0.5|%|| |Total Regulation|||±5|%|Includinginitial set accuracy| |Transient Response|||4|%|Maximum deviation, recovering to less than 1% within 500µs for 25%<br>step load change| |Ripple and Noise|||2/1|% pk-pk|2% for 12/19/24VDC,1% for 48VDC,<br>20MHz bandwidth, measured with 20MHz bandwidth and 10µF electrolytic<br>in parallel with 0.1µF ceramic capacitor.| |Overshoot||5||%|At turn on / turn off| |Overload Protection|120||200|%|| |Overvoltage Protection|||180|%|Recycle mains to reset| |Short Circuit Protection|Trip and restart (hiccup), auto resetting||||| |Temperature Coeffcient||0.04||%/°C|| ## **General** **==> picture [554 x 29] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>Efficiency 89 % See models and ratings table and curves<br>**----- End of picture text -----**<br> |Characteristic|Minimum|Typical|Maximum|Units|Notes & conditions| |---|---|---|---|---|---| |Effciency||89||%|See models and ratings table and curves| |Isolation|3000|||VAC|Input to output| ||1500|||VAC|Input to ground| ||Output return is connected to input ground||||Output to ground| |Switchingfrequency||55||kHz|At full load| |Power density||96.68 (5.9)||W/cm3(W/in3)|| |Mean time between failure||>100||khrs|MIL-HDBK-217F, 25°C GB| |Weight||370 (0.82)||g(lb)|| Specifications subject to change without notice. 2 **AC-DC power supplies** ## VES90 series **==> picture [31 x 31] intentionally omitted <==** ## **Environmental** |Characteristic|Minimum|Typical|Maximum|Units|Notes & conditions|| |---|---|---|---|---|---|---| |Operatingtemperature|0||+60|°C|Derate from 100% load at +40°C to 50% load at +60°C|| |Storage temperature|-40||+70|°C||| |Cooling|Natural convection|||||| |Operatinghumidity|10||90|%|RH, non-condensing|| |Operatingaltitude|||5000|m||| |Shock|IEC68-2-27, 30g, 30ms half sine, 3 times in each of 6 axes|||||| |Vibration|IEC68-2-6, 10-500 Hz, 0.25 g 10 mins/sweep, 60 mins for each of 3 axes|||||| ## **EMC: Emissions** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test Level|Notes & conditions| |---|---|---|---| ||||| |Conducted|EN55032|Level B|| |Radiated|EN55032|Level B|| |Harmonic currents|EN61000-3-2|Class A|| |Voltage ficker|EN61000-3-3||| ## **EMC: Immunity** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Criteria Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test Level|Criteria|Notes & conditions| |---|---|---|---|---| |||||| |ESD immunity|EN61000-4-2|±15kV Air, ±8kV contact|A|| |Radiated immunity|EN61000-4-3|3 V/m|A|| |EFT/burst|EN61000-4-4|2|A|| |Surge|EN61000-4-5|Installation Class 3|A|| |Conducted|EN61000-4-6|3V|A|| |Magnetic felds|EN61000-4-8|3A/m|A|| |Dips and interruptions|EN61000-4-11|Dip: 30% 500ms|A/B|High line/low line| |||Dip: 60% 200ms|A/B|High line/low line| |||Dip: 100% 5000ms|B|| |||Int: 100% 10ms|A|| ## **Safety approvals** **==> picture [554 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> Certification Standard Notes & conditions<br>UL UL60950-1 IEC62368-1<br>**----- End of picture text -----**<br> |Certification|Standard|Notes & conditions| |---|---|---| |UL|UL60950-1,IEC62368-1|| |EN|EN60950-1, EN62368-1|| |CB|IEC60950-1|| |AU/NZ|AU/NZ 60950.1|| |CCC|China CompulsoryCertifcation, GB4943|| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| 3 **AC-DC power supplies** ## VES90 series **==> picture [32 x 31] intentionally omitted <==** **==> picture [554 x 548] intentionally omitted <==** **----- Start of picture text -----**<br> Derating curve<br>100%<br>80%<br>60%<br>40%<br>20%<br>0 20 40 60<br>Ambient Temperature (ºC)<br>Efficiency curve<br>VES90US12 VES90US24<br>100%<br>100%<br>90% 90%<br>80% 80%<br>115Vac input<br>70% 70% 230Vac input<br>60% 60%<br>50% 50%<br>10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100<br>Load (%) Load (%)<br>Mechanical details<br> 1200 ±20 (47.24 ±0.79) 139.0 (5.47)<br>Pin Function<br>1 3 58.0<br>(2.28) 1 Output +<br>2 4 2 Output +<br>3 Return<br>LED Indicator<br>4 Return<br>IEC320-C14 (1.22)31.0 Shell return and input groundConnected to output<br>Rating Label<br>Output Power (%)<br>Efficiency Efficiency<br>**----- End of picture text -----**<br> **==> picture [139 x 54] intentionally omitted <==** ## Notes: 1. All dimensions shown in mm (inches). Tolerance is 0.5 (0.02) maximum, except output 2. Output connector: Power Mini DIN, mates with Kycon KPJX-4S or equivalent. cable length. 3. Weight: 370g (0.82lbs) approx. 30 January 2026 8
Updated at June 3, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →