VES300PS24
AC/DC Power Supply, ITE, 1 Output, 300 W, 24 VDC, 12.5 A
- Manufacturer: XP POWER
- Product type: AC / DC External Plug In Adaptor Power Supplies
- SVHC: No SVHC (15-Jan-2018)
- Plug Type: Mains Plug Sold Separately
- Product Range: VES300 Series
- No. of Outputs: 1 Output
- Output Connector: 8 Way Mini Fit JR
- Output Power Max: 300W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 12.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 76.57 € |
| Current stock | 50+ |
| Lead time | 30 days |
VES300 series ## 300W **External desktop** **AC-DC power supplies** The VES300 with energy efficiency level VI and CoC tier 2 these 300W desktop/external AC-DC power supplies are designed for high volume/low cost applications. With class I construction the VES300 are fitted with an IEC320-C14 inlet and have a voltage input range of 90 to 264VAC. Suitable UK, US and European mains cables are available to order separately. ## **Features** - f Single outputs from 19V to 48VDC - f Energy efficiency level VI - f European CoC Tier 2 **==> picture [329 x 67] intentionally omitted <==** **----- Start of picture text -----**<br> Applications Dimensions<br>197.4 x 88.9 x 39.0mm (7.77" x 3.5" x 1.53”)<br>a<br>Industrial Instrumentation Technology<br>electronics<br>**----- End of picture text -----**<br> - f China compulsory certification (CCC) qualified - f High power density - f 0.15W standby power - f -10°C to +60°C operating temperature - f 1 year warranty **==> picture [139 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> Documentation<br>For further information click the link or scan<br>the code<br>xppower.com<br>**----- End of picture text -----**<br> ## **Models & ratings** |Model number|Output voltage|Output current|Total regulation|Efficiency(1)|Output power| |---|---|---|---|---|---| |VES300PS19|19.0VDC|15.79A|±5%|92%|300W| |VES300PS24|24.0VDC|12.50A||92%|| |VES300PS48|48.0VDC|6.25A||91%|| Notes: 1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230VAC input. 1 C] **AC-DC power supplies** ## VES300 series **==> picture [32 x 31] intentionally omitted <==** ## **Input** **==> picture [553 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |**Characteristic**|**Minimum**|**Typical**|**Maximum**|**Units**|**Notes & conditions**| |---|---|---|---|---|---| ||||||| |Input voltage|90||264|VAC|Derate linearly from +100% load at 100VAC to 88% load at 90VAC| |Input frequency|47||63|Hz|| |Input current||2.9/1.5||A|Measured at 115/230VAC| |Inrush current|||120||230VAC, cold start at +25°C| |Power factor|EN61000-3-2 Class A||||| |Earth leakage current|||1|mA|264VAC, 60~~Hz~~| |No load input power|||0.15|W|| |Input protection<br>|T6.3A/250 VAC internal fuse in line||||| ## **Output** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristic|Minimum|Typical|Maximum|Units|Notes & conditions| |---|---|---|---|---|---| ||||||| |Output voltage|19||48|VDC|See models & ratings| |Initial set accuracy|||±2|%|At 50% load| |Minimum load|No minimum load required||||| |Start up delay|||3|s|| |Start up rise time|||50|ms|| |Hold up time|10|||ms|Full load and 115VAC| |Line regulation|||±0.5|%|| |Total regulation|||±5|%|| |Transient response|||5|%|Maximum deviation, recovering to less than 1% within<br>500µs for 50% to 100% step load change| |Ripple & noise|||260/380|mV pk-pk|19-24/48VDC. Measured with 20MHz Bandwidth and 10µF electrolytic in<br>parallel with 0.1µF ceramic capacitor.| |Temperature coeffcient||0.04||%/˚C|| |Short circuit protection|Trip and restart (hiccup), auto resetting||||| |Overshoot|||10|%|At turn on / turn off| |Overload protection|110||160|%|| |Overvoltage protection|||180|%|Recycle mains to reset| ## **General** **==> picture [554 x 28] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>Efficiency 91 % See models and ratings table and curves DoE Level VI, CoC Tier 2, MEPS<br>**----- End of picture text -----**<br> |Characteristic|Minimum|Typical|Maximum|Units|Notes & conditions| |---|---|---|---|---|---| |Effciency||91||%|See models and ratings table and curves DoE Level VI, CoC Tier 2, MEPS| |Isolation||3000||VAC|Input to output| |||1500||VAC|Input to ground| ||Output return is connected to input ground|||VDC|Output to ground| ||25||60|kHz|Variable. Main converter| |||80|||Variable. PFC stage| |Power density||0.43 (7.1)||W/cm3(W/in3)|| |Mean time between failure|100|||khrs|MIL-HDBK-217F, 25°C GB| |Weight||1340 (2.95)||g(lbs)|| Specifications subject to change without notice. 2 **AC-DC power supplies** ## VES300 series **==> picture [31 x 31] intentionally omitted <==** ## **Environmental** |Characteristic|Minimum|Typical|Maximum|Units|Notes & conditions|| |---|---|---|---|---|---|---| |Operatingtemperature|-10||+60|°C|Derate from 100% load at +40°C to 50% load at +60°C|| |Storage temperature|-20||+95|°C||| |Cooling|Natural convection|||||| |Operatinghumidity|10||90|%|RH, non-condensing|| |Storage temperature|-20||+95|°C||| |Operatingaltitude|||5000|m||| |Shock|IEC68-2-27, 30g, 30ms half sine, 3 times in each of 6 axes|||||| |Vibration|IEC68-2-6, 10-300 Hz, 2g 15 mins/sweep, 60 mins for each of 3 axes, non operating|||||| ## **EMC: Emissions** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test Level|Notes & conditions| |---|---|---|---| ||||| |Conducted|EN55032/FCC part 15|Class B|| |Radiated|EN55032/FCC part 15|Class B|| |Harmonic currents|EN61000-3-2|Class A|| |Voltage ficker|EN61000-3-3||| ## **EMC: Immunity** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Criteria Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test Level|Criteria|Notes & conditions| |---|---|---|---|---| |||||| |ESD immunity|EN61000-4-2|±8kV Air, ±6kV contact|A|| |Radiated immunity|EN61000-4-3|3V/m|A|| |EFT/burst|EN61000-4-4|2kV|A|| |Surge|EN61000-4-5|Installation Class 3|A|| |Conducted|EN61000-4-6|3V|A|| |Magnetic felds|EN61000-4-8|3A/m|A|| |Dips and interruptions|EN61000-4-11|Dip: 30% 500ms|A/B|High line/low line| |||Dip: 100% 5000ms|B|| |||Int: 100% 10ms|B|| ## **Safety approvals** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Certification Standard Notes & conditions<br>**----- End of picture text -----**<br> |Certification|Standard|Notes & conditions| |---|---|---| |||| |UL|UL62368-1|Approved for 0 to +40°C ambient.| |EN|EN62368-1|| |CB|IEC62368-1|| |AU/NZ|AU/NZ 62368-1|| |CCC|China CompulsoryCertifcation, GB4943|| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| 3 **AC-DC** ~~**po**~~ **wer supplies** ## VES300 se ~~ries~~ **==> picture [32 x 31] intentionally omitted <==** ## **Derating curve** **==> picture [531 x 297] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>80%<br>60%<br>40%<br>20%<br>-10 20 40 60<br>Ambient Temperature (ºC)<br>Efficiency curve<br>VES300US12 VES300US24<br>100% 100%<br>90% 90%<br>80% 80% 115Vac input<br>70% 70% 230Vac input<br>60% 60%<br>50% 50%<br>10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100<br>Load (%) Load (%)<br>Output Power (%)<br>Efficiency Efficiency<br>**----- End of picture text -----**<br> **==> picture [157 x 22] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical details<br>**----- End of picture text -----**<br> **==> picture [536 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> Pin Function<br>1<br>2<br>Return<br>3<br>4<br>5<br>6<br>Output+<br>7<br>8<br>3.5 45.0<br>(0.13) (1.77)<br>15.0<br>(0.59)<br>15.0<br> 1200 ±20.0 (47.2 ±0.79) 197.4, ±0.5 (7.77, ±0.01) (0.59)<br>88.9, ±0.5<br>(3.5, ±0.01) Pin 5 Pin 1<br>39.0, ±1.0<br>(1.53, ±0.03)<br>**----- End of picture text -----**<br> ## Notes: 1. All dimensions shown in mm (inches). Tolerance is 0.5 (0.02) maximum, except output cable length. 2. Output connector: molex Mini Fit JR, 8 way, mates with molex series #5569 plugs. 3. Weight: 1340g (2.95lbs) approx. 4. Output lead gauge is 16AWG. 5. For European mains lead, order part EU-MAINS-IEC, For UK mains lead order part UK-MAINS-IEC, For US mains lead order part US-MAINS-IEC 01 July 2025 4
Updated at June 3, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →