VEC40US12
AC/DC Power Supply, ITE, 1 Output, 40 W, 12 VDC, 3.33 A
- Manufacturer: XP POWER
- Product type: AC / DC External Plug In Adaptor Power Supplies
- No. of Outputs:1 Output; Output Power Max:40W; Output Voltage - Output 1:12V; Output Current - Output 1:3.33A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Connector:Barrel
- SVHC: No SVHC (16-Jul-2019)
- Plug Type: IEC 60320 C14
- Product Range: VEC40 Series
- No. of Outputs: 1 Output
- Output Connector: Barrel Plug Center Positive 2.5mm x 5.5mm x 11mm
- Output Power Max: 40W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3.33A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 13.26 € |
| Current stock | 10+ |
| Lead time | 30 days |
## VEC40 Series ## 40W ## **AC-DC POWER SUPPLIES** The VEC40 Series of desktop AC-DC power supplies deliver 40W offering single output voltages of 12V, 15V and 24V, and are designed for high volume applications. A low standby power which is less than 75mW enables VEC40 to comply with energy efficiency level VI standards. With world-wide safety approvals, class B compliance for conducted and radiated emissions, high efficiency and 3kVAC isolation, the limited power source (LPS) approved VEC40 series benefits system designers with easy integration into a wide range of industrial applications including test and measurement, process control, industrial displays and analytical instrumentation. ## **Features** . ## • Single outputs of 12V, 15V and 24V - 90-264VAC input range **==> picture [156 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> Applications<br>Analytical Display Industrial Process<br>Instrumentation Systems Electronics Control<br>**----- End of picture text -----**<br> - High efficiency – 89% - <75mW standby power – Energy efficiency level VI - China Compulsory Certification (CCC) qualified **==> picture [54 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions<br>**----- End of picture text -----**<br> 4.58” x 2.06” x 1.23” (116.3 x 52.4 x 31.3mm) - ITE safety approvals - 3kVAC isolation - Class B conducted and radiated emissions - Operating temperature range of 0–65˚C - Overload, overvoltage, and short circuit protection - Optional inlet connector ## **Models & Ratings** |Model Number(1)<br>VEC40US12|Output Voltage<br>12.0V|Output Current<br>3.33A|Total Regulation<br>±5%|Efficiency(1)<br>89%|Output Power<br>40W| |---|---|---|---|---|---| |VEC40US15|15.0V|2.67A||89%|| |VEC40US24|24.0V|1.67A||89%|| Notes: 1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input. 2. For optional IEC320-C6 inlet add suffix -C6 to the part number, e.g. VEC40US24-C6. MOQs apply, contact sales for details. AC-DC POWER SUPPLIES ## VEC40 Series ## **Input** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Input Voltage|90||264|VAC|| |Input Frequency|47||63|Hz|| |Input Current||0.8/0.6|||Measured at 115VAC/240VAC| |Inrush Current|||110|A|230VAC cold start, 25°C| |Power Factor|||||EN61000-3-2 Class A| |Earth Leakage Current|||0.7|mA|240VAC, 60Hz| |No Load Input Power|||0.1|W|| |Input Protection|T3.15A/250VAC internal fuse in line||||| ## **Output** **==> picture [540 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Output Voltage|12||24|VDC|See Models and Ratings| |Minimum Load|No minimum load required||||| |Start Up Delay|||4|s|| |Start Up Rise Time|||50|ms|| |Hold Up Time|8|||ms|115VAC full load| |Line Regulation|||±0.5|%|| |Load Regulation|||±5|%|Including initial set accuracy| |Transient Response|||4|%|Maximum deviation, recovering to less than 1% within 500μs for 25%<br>step load| |Overshoot||5||%|At turn on/turn off| |Ripple & Noise|||240|% pk-pk|Measured with 20 MHz Bandwidth and 22μF electrolytic in parallel<br>with 0.1μF ceramic capacitor.| |Overvoltage Protection||175||%|Recycle mains to reset| |Overload Protection|110||170|%|| |Temperature Coeffcient||±0.04||%/˚C|| |Short Circuit Protection<br>|Trip and restart (hiccup mode), auto resetting||||| ## **General** |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Effciency||89||%|See Models and Ratings and Effciency Curves| |Isolation: Input to Output<br>Input to Ground<br>Output to Ground|||3000|VAC|| ||||1500|VAC|| |||||VDC|Negative output is connected to ground| |Switching Frequency||65||kHz|±10kHz| |Power Density|||3.14|W/in3|| |Mean Time Between Failure||>200||khrs|MIL-HDBK-217F 25°C GB| |Weight||0.52 (240)||lb (g)|| 2 AC-DC POWER SUPPLIES ## VEC40 Series ## **Application Notes** Derating Curve Figure 1 **==> picture [238 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>80%<br>60%<br>40%<br>20%<br>0 45 65<br>Ambient Temperature (ºC)<br>Output Power (%)<br>**----- End of picture text -----**<br> ## **Environmental** |Characteristic<br>Operating Temperature|Minimum<br>0|Typical|Maximum<br>+65|Units<br>°C|Notes & Conditions<br>Derate from 100% load at 45°C to 50% load at 65°C| |---|---|---|---|---|---| |Storage Temperature|-20||+85|°C|| |Cooling|Natural convection||||| |Humidity|5||90|%RH|Non-condensing| |OperatingAltitude|||5000|m|| |Vibration|IEC68-2-6, 10-500 Hz, 2g 10 mins/sweep, 60 mins for each of 3 axes||||| |Shock|IEC68-2-27, 30g, 11ms half sine, 3 times in each of 6 axes||||| ## **Efficiency Curves** **==> picture [45 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Figure 2<br>VEC40US12<br>**----- End of picture text -----**<br> ## **Figure 3 VEC40US24** **==> picture [235 x 100] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>10 20 30 40 50 60 70 80 90 100<br>Load (%)<br>**----- End of picture text -----**<br> **==> picture [235 x 101] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>10 20 30 40 50 60 70 80 90 100<br>Load (%)<br>**----- End of picture text -----**<br> 115VAC input 230VAC input Specifications subject to change without notice. 3 AC-DC POWER SUPPLIES ## VEC40 Series ## **EMC: Emissions** |Phenomenon|Standard|Test Level|Notes & Conditons| |---|---|---|---| |Conducted|EN55032|Class B|| |Radiated|EN55032|Class B|| |Voltage Flicker|EN61000-3-3||| ## **EMC: Immunity** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Criteria Notes & Conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test Level|Criteria|Notes & Conditons| |---|---|---|---|---| |Harmonic Current|EN61000-3-2|Class A||| |ESD Immunity|EN61000-4-2|±8kV Air, ±4kV contact|A|| |Radiated Immunity|EN61000-4-3|3V/m|A|| |EFT/Burst|EN61000-4-4|3|A|| |Surge|EN61000-4-5|Installation Class 3|A|| |Conducted|EN61000-4-6|3V|A|| |Magnetic Field|EN61000-4-8|3 A/m|A|| |Dips and Interruptions|EN61000-4-11|Dip: 30% 500ms|A/B|High Line/Low Line| |||Dip: 60% 200ms|A/B|High Line/Low Line| |||Int: 100% 5000ms|B|| ## **Safety Approvals** **==> picture [539 x 117] intentionally omitted <==** **----- Start of picture text -----**<br> Certification Standard Notes & Conditions<br>CB IEC60950-1, IEC62368-1<br>UL /CSA UL60950-1, UL62368-1<br>EN EN60950-1, EN62368-1 Approved at Limited Power Source (LPS)<br>CCC China Compulsory Certification, GB4943<br>AU/NZ AU/NZ 60950.1<br>CE Meets all applicable directives<br>UKCA Meets all applicable legislation<br>**----- End of picture text -----**<br> 4 AC-DC POWER SUPPLIES ## VEC40 Series ## **Mechanical Details** **==> picture [475 x 238] intentionally omitted <==** **----- Start of picture text -----**<br> Cable length: 47.2” ± 0.8” (1200 mm ±20 mm)<br>IEC320-C14<br>2.06<br>(52.4) 1.57 ±0.08 0.43<br>(40.0 ±2.0) (100.0) (11.0)<br>0.89 0.4<br>(22.7) (10.0)<br>4.58<br>(116.3)<br>Op�onal IEC320-C6<br>1.23<br>(31.3)<br>Core Diameter: 0.79” ± 0.08” (20mm ±2 mm)<br>0.89<br>(22.7)<br>3.94<br>**----- End of picture text -----**<br> Notes: 1. All dimensions are shown in inches (mm), Tolerance is 0.04” (±1.0) max except output lead. 2. Weight: 0.52lbs (240g) approx. 3. Output connector is barrel type with 11mm length, 5.5mm dia. outer, 2.5mm dia. inner with center + and outer shell - polarity. **==> picture [148 x 49] intentionally omitted <==** 20 Jun 2023 **5**
Updated at June 3, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →