VCT40US05
AC/DC Open Frame Power Supply (PSU), ITE, 1 Output, 40 W, 85V AC to 264V AC, Fixed
- Manufacturer: XP POWER
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):40W; Power Rating (Forced Cooling):-; Input Voltage VAC:85V AC to 264V AC; Power Supply Output Type:Fixed; Output Voltage -
- SVHC: No SVHC (15-Jan-2018)
- Product Range: VCTSeries
- No. of Outputs: 1 Output
- Output Power Max: 40W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 10A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 40W
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 20.86 € |
| Current stock | 10+ |
| Lead time | 30 days |
**60 Watts** xppower.com ## **VCT Series** - Low Cost - Single Outputs from 5 V to 30 V - Peak Load Capability - Convection-cooled - <0.5 W No Load Input Power - 2”x 4”Package **==> picture [60 x 35] intentionally omitted <==** **----- Start of picture text -----**<br> B a R A N D<br>**----- End of picture text -----**<br> - Fits 1U Applications ## **Speci** ~~**fication**~~ ## **Input** - Input Voltage • 85-264 VAC Input Frequency • 47-63 Hz Input Current • 1.7 A max at 115 VAC, 0.85 A max at 230 VAC - Inrush Current • 80 A typ. at 230 VAC, cold start at 25 °C Earth Leakage Current • 500 μ A at 264 VAC / 60 Hz Power Factor • EN61000-3-2, class A No Load Input Power • <0.5 W Input Protection • Internal T3.15A/250 V fuse in line ## **Output** - Output Voltage • See table Output Voltage Trim • None Initial Set Accuracy • ±2% at 50 % load Minimum Load • No minimum load requirement Start Up Delay • 2 s max Start Up Rise Time • 8 ms typical Hold Up Time • 8 ms typical at full load and 115 VAC Line Regulation • ±0.5% max Load Regulation • ±1.0% max (see note 1) Transient Response • 4% maximum deviation, recovering to less than 1% within 500 μ s for 50% step load Ripple & Noise • 1% max pk-pk (see note 2) Overvoltage Protection • See table Overload Protection • 133-166% Short Circuit Protection • Trip and restart (hiccup mode) Temperature • 0.02% / ˚ C Coefficient ## **General** |**General**|| |---|---| |Efficiency|• See table| |Isolation|• 3000 VAC Input to Output| ||1500 VAC Input to Ground| ||500 VDC Output to Ground| |Switching Frequency|• 60 kHz ±10 kHz| |MTBF|• >700 kHrs to Bell Core iss. 6| |**Environmental**|| |Operating Temperature|• -10˚C to +70˚C derate from 100% load| ||at 50˚C to 50% load at 70˚C| |Cooling|• Natural convection| |Operating Humidity|• 5% to 90% RH, non condensing| |Operating Altitude<br>Storage Temperature|• 3000 m<br>• -20˚C to +85˚C| |Shock|• IEC68-2-6, 30 g, 11 mins half sine, 3 times<br>in each of 6 axes| |Vibration|• IEC68-2-27, 10-500Hz, 2 g 10 mins /<br>sweep. 60 mins for each of 3 axes| ## **Environmental** ## **EMC & Safety** |**EMC & Safetyy**|| |---|---| |Emissions<br>Harmonic Currents|• EN55032, level B conducted & radiated<br>• EN61000-3-2 class A| |Voltage Flicker|• EN61000-3-3| |ESD Immunity|• EN61000-4-2, level 3, Perf Criteria A| |Radiated Immunity|• EN61000-4-3, 10 V/m, Perf Criteria A| |EFT/Burst|• EN61000-4-4, level 3, Perf Criteria A| |Surge|• EN61000-4-5, installation class 3,<br>Perf Criteria A| |Conducted Immunity|• EN61000-4-6, 10 V, Perf Criteria A| |Dips & Interruptions|• EN61000-4-11, 30% 10 ms,| ||60%, 100 ms, 100%, 5000 ms| ||Perf Criteria A, B, B| |Safety Approvals|• UL60950-1, IEC60950-1,| ||EN60950-1, UL62368-1, EN62368-1,| ||IEC62368-1, CE (Meets all applicable| ||directives), UKCA (Meets all applicable| ||legislation)| **VCT60** ## ~~**Models and Ratings**~~ |Output Voltage(6)|Output Current<br>Nominal<br>Peak(3)|Output Current<br>Nominal<br>Peak(3)|OVP Setting(5)|Efficiency(4)|Model Number| |---|---|---|---|---|---| |||Peak(3)|||| |5.0 V|8.00 A|10.0 A|7.0 V|82%|VCT40US05| |12.0 V|5.00 A|6.3 A|13.0 V|87%|VCT60US12| |15.0 V|4.00 A|5.0 A|17.0 V|87%|VCT60US15| |24.0 V|2.50 A|3.1 A|29.0 V|88%|VCT60US24| ## ~~**Notes**~~ _1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load)._ _2. Measured at the output connector with a 0.1 μ F ceramic capacitor and a 10 μ F electrolytic capacitor._ _3. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal._ _4. Average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input._ _5. Typical trip point._ _6. Other voltages between 5 V and 30 V available on request, contact sales for details._ ## ~~**Mechanical Details**~~ **==> picture [482 x 407] intentionally omitted <==** **----- Start of picture text -----**<br> 3.75 (95.3)<br>0.06 (1.6) PCB Thickness<br>0.12 (3.2)<br>2<br>—— 1 — = |<br>2.0<br>1.75 (50.8)<br>(44.5) 1<br>4<br>[es | Be i<br>0.09 (2.5) Lead Length<br>0.12<br>mS mo 2S<br>(3.1) Ø0.13 (3.5)-4 Places Output Connector<br>1 +Vout<br>2 +Vout<br>3 -Vout<br>4 -Vout<br>Mates with: Molex Housing<br>0.78 09-50-3041 and Molex Series<br>(20.0) 0.94 2878 crimp terminals.<br>(24.1)<br>Input Connector<br>Pin 1 Neutral<br>Pin 2 Live<br>(Om ai. —_<br>a 4.0 (101.6) Mates with: Molex Housing<br>09-50-3031 and Molex Series<br>2878 crimp terminals.<br>Mounting holes marked with<br> must be connected to<br>safety earth<br>Notes<br>**----- End of picture text -----**<br> 1. All dimensions shown in inches (mm). 3. Tolerance: x.xx = ±0.04 (x.x = ±0.1); x.xxx = ±0.2 (x.xx = ±0.5) 2. Weight 0.29 lbs (130 g) approx 28 Oct 2021
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →