VCB60US12
AC/DC Open Frame Power Supply (PSU), ITE & Household, 1 Output, 60 W, 90V AC to 305V AC, Fixed
- Manufacturer: XP POWER
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (27-Jun-2024)
- Product Range: VCB60 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 305V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Household
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 60W
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 11.17 € |
| Current stock | 200+ |
| Lead time | 30 days |
## VCB60 Series ## 60W ## **CONVECTION COOLED** ## AC-DC POWER SUPPLIES The VCB60 is a series of open frame AC-DC single output power supplies designed for low cost ITE, industrial and domestic applications. With approvals to world-wide safety standards including ITE and Household, compliance with class B for conducted and radiated emissions, this series benefit system designers with easy integration into a wide range of applications. A wide input range of 90-305VAC and approval to overvoltage category III (OVC III) eases installation in building wiring systems. ## **Features** - 60W convection cooled ## **Applications** - 4” x 2” footprint, low 1.01” profile - Low cost - ITE & household appliance approvals - Overvoltage category III - EN55035 and EN55024 immunity standard - Class I operation - Input voltage range 90 to 305VAC - Regulated single outputs from 5 to 54VDC **==> picture [143 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> Household Industrial<br>Appliances Electronics<br>BQaN ©ao<br>Instrumentation IoT Robotics<br>**----- End of picture text -----**<br> - Efficiency to 90% - Short circuit, overvoltage & overload protection - -10°C to +70°C operating temperature ## **Dimensions** 4.00” x 2.00” x 1.01” (101.6 x 50.8 x 25.6mm) - Full load to +50°C ## **Models & Ratings** |Model Number<br>VCB60US05|Output Power<br>40W|Output Voltage<br>5.0VDC|Output Current<br>8.00A| |---|---|---|---| |VCB60US12|60W|12.0VDC|5.00A| |VCB60US15|60W|15.0VDC|4.00A| |VCB60US19|60W|19.0VDC|3.16A| |VCB60US24|60W|24.0VDC|2.50A| |VCB60US30|60W|30.0VDC|2.00A| |VCB60US48|60W|48.0VDC|1.25A| |VCB60US54|60W|54.0VDC|1.11A| AC-DC POWER SUPPLIES ## VCB60 Series ## **Input** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Input Voltage|90||305|VAC|| |Input Frequency|47||63|Hz|| |Input Current - Full Load||1.7/0.85||A rms|115/230VAC full load| |No Load Input Power|||0.3|W|| |Inrush Current|||70|A|At 230VAC, cold start 25°C| |Earth Leakage Current|||200|μA|| |Input Protection|Internal T3.15A/300VAC fuse ftted in line||||| ## **Output** **==> picture [540 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc<br>|Minimum|Typical|Maximum|Units<br>|Notes & Conditons| |---|---|---|---|---|---| |Output Voltage|5||54|VDC|| |Initial Set Accuracy|||1.0|%|| |Minimum Load|0|||A|No minimum load| |Line Regulation|||1|%|| |Load Regulation|||2|%|| |Start Up Delay|||2.5|s|| |Start Up Rise Time|||35|ms|| |Hold Up Time|8|14||ms|At full load and 115 VAC| |Transient Response|||4|%|Deviation, recovery within 1% in less than 500μs for a 25%<br>load change| |Ripple & Noise|||1|%|Measured with 20MHz bandwidth and 10μF electrolytic in parallel with<br>0.1μF ceramic| |Overvoltage Protection|115||160|%Vnom|| |Overload Protection|110||190|%|| |Short Circuit Protection|Trip and restart (hiccup mode)||||| |Temperature Coeffcient|||0.05|%/°C|| ## **General** |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Effciency||85||%|Model dependant| |Isolation: Input to Output<br>Input to Ground<br>Output to Ground|3000|||VAC|| ||1500|||VAC|| ||500|||VDC|| |Switching Frequency|5||75|kHz|Varied with load| |Power Density|||7.4|W/in3|| |Mean Time Between Failure|550|600||khrs|MIL-HDBK-217F, 25°C GB.| |Weight||0.29 (130)||lb (g)|| 2 AC-DC POWER SUPPLIES ## VCB60 Series ## **Efficiency Graphs** ## **VCB60US12** **==> picture [430 x 402] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>115Vac<br>80% 230Vac<br>70%<br>60%<br>50%<br>10 20 30 40 50 60 70 80 90 100<br>Load (%)<br>100%<br>90%<br>80%<br>115Vac<br>230Vac<br>70%<br>60%<br>50%<br>10 20 30 40 50 60 70 80 90 100<br>Load (%)<br>Efficiency<br>Efficiency<br>**----- End of picture text -----**<br> ## **VCB60US24** ## **Environmental** |**Environmental**|||||| |---|---|---|---|---|---| |Characteristic<br>Operating Temperature|Minimum<br>-10|Typical|Maximum<br>+70|Units<br>°C|Notes & Conditions<br>Derate linearly from 100% load at +50°C to 50%<br>load at +70°C.| |Storage Temperature|-40||+85|°C|| |Cooling|Convection cooled||||| |Humidity|||95|%RH|Non-condensing| |OperatingAltitude|||5000|m|| |Shock|IEC68-2-27, 30g, 11ms half sine, 3 times in each of 6 axes||||| |Vibration|IEC68-2-6, 2g, 10Hz to 500kHz, 10 mins/cycle, 60 mins each cycle||||| 3 AC-DC POWER SUPPLIES ## VCB60 Series ## **EMC: Emissions** **==> picture [539 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Criteria Notes & Conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test Level|Criteria|Notes & Conditons| |---|---|---|---|---| |Conducted|EN55032, EN55014-1|Class B||| |Radiated|EN55032, EN55014-1|Class B||| |Harmonic Current|EN61000-3-2|Class A||| |Voltage Flicker|EN61000-3-3|||| ## **EMC: Immunity** **==> picture [536 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Criteria Notes & Conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test Level|Criteria|Notes & Conditons| |---|---|---|---|---| |ITE|EN55024<br>EN55035<br>EN55014-2|As below|As below|| |ESD Immunity|EN61000-4-2|2 / 3|A|±6kV contact / ±8kV air discharge| |Radiated Immunity|EN61000-4-3|10V/m|A|| |EFT|EN61000-4-4|3|A|| |Surge|EN61000-4-5|2|A|Line to Line| |Conducted|EN61000-4-6|10Vrms|A|| |Magnetic Fields|EN61000-4-8|30A/m|A|| |Dips and Interruptions|EN61000-4-11<br>(115 VAC)|70% UT(80.5 VAC) for 100ms|A|| |||40% UT(46 VAC) for 200ms|B|| |||<5% UT(0 VAC) for 10ms|A|| |||<5% UT(0 VAC) for 5000ms|B|| ||EN61000-4-11<br>(230 VAC)|70% UT(161 VAC) for 100ms|A|| |||40% UT(92 VAC) for 200ms|A|| |||<5% UT(0 VAC) for 10ms|A|| |||<5% UT(0 VAC) for 5000ms|B|| ## **Safety Approvals** |Certfcaton|Standard|Notes & Conditons| |---|---|---| |CB Report|IEC60950-1, IEC62368-1|Information and Communication Technology<br>Equipment| ||IEC60335-1|Household and Similar Appliances| |UL|UL62368-1|Information and Communication Technology<br>Equipment| |EN|EN62368-1|Information and Communication Technology<br>Equipment| ||EN61558-1 & -2-16|General Safety for Power Supplies| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| 4 AC-DC POWER SUPPLIES ## VCB60 Series ## **Mechanical Details** **==> picture [475 x 332] intentionally omitted <==** **----- Start of picture text -----**<br> 4.00, ±0.04 (101.6, ±1.0) .<br>0.124, ±0.01<br>a —<—- —<br>(3.15, ±0.2)<br>P1 0.124 ±0.01 (3.15 ±0.2)<br>CN1<br>N L<br>Sy PT Ss<br>0.124 ±0.01<br>| : ——<br>(3.15 ±0.2)<br>2.00, ±0.04 L Oe<br>(50.8, ±1.0) Na 3] Te P1<br>q ai<br>_ e =iecom Q1 3<br>Ø0.14, x4 (Ø3.5 x 4) 0.124 ±0.01<br>(3.15 ±0.2)<br>T=0.06<br>(1.6)<br>A 0.12 max<br>0.83 (+0.08, -0.04) (3.0 max)<br>21.0 (+2.0, -1.0)<br>CN2<br>**----- End of picture text -----**<br> **==> picture [274 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> ee Pin Connections CN1 — Pin Connections CN2<br>Pin Function<br>EE<br>1 N<br>2 2 +Vout<br>3 L 3 -Vout<br>4 -Vout<br>Mates with MOLEX housing 09-50-3031<br>Mates with MOLEX housing 09-50-3041<br>and MOLEX series 2878 crimp terminals<br>and MOLEX series 2878 crimp terminals<br>**----- End of picture text -----**<br> ## **Notes:** 1. Dimensions in inches (mm). 3. Tolerances:x.xx = ± 0.04 (x.x = ±1.0) x.xxx = ± 0.01 (x.xx = ± 0.25) 2. Weight: 0.29lbs (130g) 5 15 Sept 2022
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →