Image not available
Illustrative purposes only
UMA30F-48
AC/DC Open Frame Power Supply (PSU), ITE, Household & Medical, 1 Output, 31.2 W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: COSEL
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (23-Jan-2024)
- Product Range: UMAF Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 650mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Household & Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 31.2W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 20.57 € |
| Current stock | 25+ |
| Lead time | 30 days |
**AC-DC Power Supplies Medical Type** ~~——~~ : 414 Medical World wide Cost Safety EMI Inrush OCP OVP electric Effective Approvals current equipment limiting **UMA** ## **UMA-series** ## **Feature** For medical electric equipment Medical Isolation Grade 2MOPP 4kV isolation Suitable for BF application Low leakage current 2"× 3" standard footprint Economical design ## **Safety agency approvals** ANSI/AAMI ES60601-1, EN60601-1 3rd, C-UL (CAN/CSA-C22.2 No.60601-1), UL62368-1, EN62368-1, C-UL (CAN/CSA-C22.2 No.62368-1), Complies with EN60335 ## **CE marking** Low Voltage Directive RoHS Directive ## **UKCA marking** Electrical Equipment Safety Regulations RoHS Regulations **5-year warranty** (See Instruction Manual) ## **EMI** Complies with CISPR11 classB, CISPR32 classB, EN55011-B, EN55032-B, FCC Part15 classB and FCC Part18 classB **EMS Compliance** : EN61204-3, EN61000-6-2 IEC60601-1-2 (2014), EN60601-1-2 (2015) EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 **UMA-1** October 10, 2023 **AC-DC Power Supplies Medical Type Ordering information - - UM A 30 F** O O **UMA30F** ~~a~~ **UMA** ~~|ce~~ 1 2 3 4 5 6 1Series name 3 R UK 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *5 E : IEC Class II T : Terminal block Y : with Potentiometer |**MODEL**<br>~~es~~<br>~~|~~|**MODEL**<br>~~es~~<br>~~|~~|**UMA30F-5**|**UMA30F-12**|**UMA30F-15**|**UMA30F-24**|**UMA30F-36**| |---|---|---|---|---|---|---| |**VOLTAGE[V]**<br>~~es~~<br>~~|~~<br>i—‘“‘CSCSs—szCY||||||| |**CURRENT[A]**<br>~~|~~<br>~~ee~~<br>~~|~~|**ACIN 115V** <br>~~ee~~|0.35<br>~~ee~~||||| ||**ACIN 230V** <br>~~ee~~<br>~~a~~|0.15<br>~~ee~~||||| |**FREQUENCY[Hz]**<br>~~a~~<br>~~|~~<br>—“‘CSCSC*CY<br>~~ee~~||||||| |**EFFICIENCY[%]**<br>~~|~~<br>~~ee~~|**ACIN 115V** <br>~~a~~<br>~~e~~|81typ<br>~~ee ee~~|86typ<br>~~ee~~|86typ<br>~~ee~~|88typ<br>~~ee~~|88typ<br>~~ee~~| ||**ACIN 230V** <br>~~e~~<br>~~a~~|80typ<br>~~ee ee~~<br>~~a~~<br>~~a~~|87typ<br>~~ee~~<br>~~a~~<br>~~a~~|87typ<br>~~ee~~<br>~~a~~|89typ<br>~~ee~~|89typ<br>~~ee~~| |**INRUSH CURRENT[A]**<br>~~ee~~<br>~~—~~<br>~~|~~|**ACIN 115V** <br>~~e~~<br>~~—~~|||||| ||**ACIN 230V** <br>~~—~~<br>~~||~~<br>~~ee~~|||||| |**LEAKAGE CURRENT[uA] **<br>~~ee~~<br>~~|~~|**ACIN 264V** <br>~~ee~~<br>~~ee~~|||||| |**TOUCH CURRENT[uA] **<br>~~|~~<br>rt—“‘C*dSCsC*C|**ACIN 264V** <br>~~ee~~<br>rt—“‘C*dSCsC*C|||||| |**VOLTAGE[V]**<br>~~ee~~<br>~~|~~<br>~~a~~||5<br>~~ee~~|12|15|24|36| |**CURRENT[A]**<br>~~CQ~~||3<br>~~CQ~~|2.5<br>~~CQ~~|2<br>~~CQ~~|1.3<br>~~CQ~~|0.85<br>~~CQ~~| |**WATTAGE[W]**<br>~~a~~<br>~~Rs~~||15|30|30|31.2|30.6| |**LINE REGULATION[mV]**<br>*1 <br>~~Rs~~<br>~~Rs~~||20max<br>~~GO~~|48max<br>~~GO~~|60max<br>~~GO~~|96max<br>~~GO~~|144max<br>~~GO~~| |**LOAD REGULATION[mV]** *1 <br>~~Rs~~<br>~~Rs~~<br>~~eee~~<br>~~Re~~||100max<br>~~GO~~<br>~~eee~~<br>|120max<br>~~GO~~<br>|120max<br>~~GO~~<br>|150max<br>~~GO~~<br>|240max<br>~~GO~~<br>| |**RIPPLE NOISE[mVp-p]** *2 <br>~~Rs~~<br>~~ee~~<br>~~Re~~|**lo=100%** <br>~~Rs~~<br>~~ee~~<br>~~eee~~<br>|||||| |**TEMPERATURE REGULATION[mV] **<br>~~Re~~|**0~+50**C <br>~~eee~~<br>~~sf~~|100max<br>~~eee~~<br>~~sf~~|120max<br>~~sf~~|150max<br>~~sf~~|240max<br>~~sf~~|360max<br>~~sf~~| |**START-UP TIME[ms]**<br>~~Re~~<br>~~—~~|**ACIN 115V** <br>~~eee~~<br><br>~~—~~|||||| ||<br>**ACIN 230V**<br>~~—|~~|||||| |**HOLD-UP TIME[ms]**<br>~~—~~<br>~~|~~|**ACIN 115V** <br>~~—~~|||||| ||**ACIN 230V** <br>~~—~~<br>~~||~~|||||| |**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]** <br>~~||~~<br>~~|~~<br>—i(‘CSC™SC™*~*zY<br>~~Rs~~||||||| |**OUTPUT VOLTAGE SETTING[V]**<br>~~||~~<br>~~|~~<br>~~Rs~~<br>~~[|~~||4.90 to 5.30|11.50 to 12.50|14.40 to 15.60|23.00 to 25.00|34.50 to 37.50| |**OVERCURRENT PROTECTION[A]**<br>~~Rs~~<br>~~[|—sSY~~<br>~~Rs~~||||||| |**OVERVOLTAGE PROTECTION[V]**<br>~~[|~~<br>~~Rs~~<br>~~|~~||5.75 to 7.00|13.80 to 16.80|17.25 to 21.00|27.60 to 33.60|41.40 to 50.40| |**INPUT-OUTPUT**<br>~~Rs~~<br>~~|~~<br>—i(i‘CSs™S™Ss—~s~™Y||||||| |**INPUT-FG**<br>~~|~~<br>~~sis~~<br>~~|~~||||||| |**OUTPUT-FG**<br>~~|~~<br>rt—“‘“CS:*S*:C~C~C~s*zCY<br>~~|~~||||||| |**OPERATING TEMP.,HUMID.** *3 <br>~~|~~<br>~~|~~<br>—i—‘sSCSCsY<br>~~|~~||||||| |**STORAGE TEMP.,HUMID.**<br>~~|~~<br>~~|~~<br>t—(i‘“C;S™SC*~*™Y<br>~~|~~||||||| |**VIBRATION**<br>~~|~~<br>~~|~~<br>—(‘CS™S~S~—~s*CY<br>~~|~~||||||| |**IMPACT**<br>~~|~~<br>~~|—“CsSSCsY~~||||||| |**AGENCY APPROVALS**<br>~~|~~<br>~~|~~||||||| |**EMC EMISSON**<br>~~|~~<br>—“‘CS™SC™*~*™Y<br>~~|~~||||||| |**EMC EMMUNITY**<br>~~|~~<br>~~|~~<br>—its—‘CSsSC—szCY<br>~~|~~||||||| |**HARMONIC ATTENUATOR***6 <br>~~|~~<br>~~|~~<br>t—“‘CS*S*SC~s~s*zY<br>~~|~~||||||| |**CASE SIZE/WEIGHT***7 <br>~~|~~<br>~~|~~<br>——iti‘CsSCSC—~szCY<br>~~[|~~||||||| |**COOLING METHOD**<br>~~|~~<br>~~[|—“CsSSCsY~~<br>~~|~~<br>~~ti“~~||||||| |**WARRANTY**<br>*4<br>~~[|~~<br>~~|~~<br>~~ti“~~<br>(itwt:t:”™~*~:~szr||||||| - *1 Consult us about dynamic load and input response. Measure the output voltage by using the average mode of the tester to deal with the burst operation at low (Io=0~20%Atyp) load. - *2 This is the result of measurement of the testing board with capacitors of 47μF and 0.1μF placed at 150 mm from the output terminals by a 20MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-GikenRM104. - When the load factor is low (Io=0~20%Atyp), the switching power loss is reduced by burst operation, which will cause ripple noise to go beyond the specifications. - *3 Output power derating is required. Refer to "Derating" - *4 Consult us about details. - *5 The listed options may affect the published standard specifications. Please contact us for detailed product specifications and safety approvals. - *6 Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details. - *7 Dimensions below PCB are not included. - All parameters not specially mentioned are measured at ACIN 230V, rated load and 25℃ of ambient temperature. - Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. - * Parallel operation is not possible with this model. - Acoustic noise may be heard from the power supply when used for pulse load. **UMA-2** October 10, 2023 **UMA30F** **External view** ~~DT~~ **UMA** **==> picture [394 x 340] intentionally omitted <==** **----- Start of picture text -----**<br> Voltage adjust<br>Name plate (Optional -Y)<br> (Display item)<br>Model name<br>Rated Input/Output<br>Production Country<br>Lot No. 22.5<br>Safety Agency Mark Logo [0.89]<br>Company Logo<br>AC(L) ——s 3 -V 12<br>AC(N) 1 +V 34<br>CN1 CN2<br>Mating connector and terminal of CN1, CN2<br>I/O Connector Mating Connector Terminal Mfr.<br>Reel : SVH-21T-P1.1<br>F N] “|| CN1 B2P3-VH VHR-3N pieceLoose [ : BVH-21T-P1.1] J.S.T.<br>FG Chain : SVH-21T-P1.1<br>1 4- 3.3 [ 0.13] CN2 B4P-VH VHR-4N Loosepiece : BVH-21T-P1.1 J.S.T.<br>Mounting Hole<br>3.2 69.8 ±0.5<br>[0.13] [2.75]<br><Pin Assignments><br>76.2 CN1 CN2<br>[3] Pin No. Input Pin No. Output<br>1 AC(N) 1, 2 -V<br>2<br>3 AC(L) 3, 4 +V<br>en =e<br> Dimensions in mm, [ ] =inches<br> Tolerance : ±1 [±0.04]<br> Weight : 80g max<br> PCB Material/thickness : CEM-3/1.6 [0.06]<br>1 The mounting hole is for FG connection.<br>The mounting hole in the -E option is not for FG connection.<br>4<br>[0.16]<br>±0.5<br>50.8 [2]<br>44.4 [1.75]<br>3.2 [0.13]<br>21.7 [0.85]<br>2.5max [0.1max]<br>**----- End of picture text -----**<br> ## **Derating Curve** **==> picture [205 x 195] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80 ym Ty TNAL 15V<br>Po OY<br>70 5V, 12V, 24V, 36V, 48V<br>ONT<br>60 FEELIN<br>50 FEELS<br>40 FECES<br>30<br>a<br>20<br>FECES<br>10<br>FEELS<br>0 EL<br>-20 -10 0 10 20 30 40 50 60 70<br>Ambient temperature ( Cc )<br>*The shaded area is the derating required at start-up.<br>Fig.1 Derating curve depending on ambient temperature<br>Load factor (%)<br>**----- End of picture text -----**<br> **==> picture [204 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80 WA<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>85 115 264<br>Input Voltage(VAC)<br>Load factor (%)<br>**----- End of picture text -----**<br> **==> picture [150 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Fig.2 Derating curve depending on input voltage<br>**----- End of picture text -----**<br> ■The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be influenced by the heat from the power supply. Please consult us for more details. **UMA-3** October 10, 2023 ~~|~~ **UMA** **AC-DC Power Supplies Medical Type UMA60F UMA** ~~a~~ **Ordering information** ## R Ws DO) ~~CE~~ ES **- - UM A 60 F** O O 1 2 3 4 5 6 1Series name 2Single output 3Output wattage ay 4Universal input 5Output voltage 6Optional *5 E : IEC Class II T : Terminal block Y : with Potentiometer |*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.|*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.|*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.|*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.|*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.|*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.|*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.|| |---|---|---|---|---|---|---|---| |**MODEL**|**UMA60F-5**|**UMA60F-7R5**|**UMA60F-12**|**UMA60F-15**|**UMA60F-24**|**UMA60F-36**|**UMA60F-48**| |**MAX OUTPUT WATTAGE[W]**|30|41.25|54|52.5|60|61.2|60| |**DC OUTPUT**|5V 6A|7.5V 5.5A|12V 4.5A|15V 3.5A|24V 2.5A|36V 1.7A|48V 1.25A| ## **SPECIFICATIONS** |**MODEL**<br>~~CC~~<br>~~LF~~|**MODEL**<br>~~CC~~<br>~~LF~~|**UMA60F-5**<br>~~CC~~<br>|**UMA60F-7R5**<br>~~CC~~<br>|**UMA60F-12**<br>~~CC~~|**UMA60F-15**<br>~~CC~~|**UMA60F-24**<br>~~CC~~|**UMA60F-36**<br>~~CC~~| |---|---|---|---|---|---|---|---| |**VOLTAGE[V]**<br>~~LF~~|||||||| |**CURRENT[A]**<br>~~LFee~~<br>~~|~~|**ACIN 115V** <br>~~ee~~<br>~~es~~<br>|0.7<br>~~ee~~<br>~~ee~~<br>|1.0<br>~~ee~~<br>||||| ||**ACIN 230V** <br>~~ee~~<br>~~es~~<br>|0.3<br>~~ee~~<br>~~ee~~<br>|0.5<br>~~ee~~<br>||||| |**FREQUENCY[Hz]**<br>~~es~~<br>~~|~~|||||||| |**EFFICIENCY[%]**<br>~~|S/H,~~<br>~~|~~|**ACIN 115V** <br>~~es~~<br>~~S/H,~~|80typ<br>~~ee~~<br>~~S/H,~~|84typ<br>~~S/H,~~|87typ<br>~~S/H,~~|86typ<br>~~S/H,~~|88typ<br>~~S/H,~~|89typ<br>~~S/H,~~| ||**ACIN 230V** <br>~~S/H,~~<br>~~|~~|80typ<br>~~S/H,~~|85typ<br>~~S/H,~~|88typ<br>~~S/H,~~|87typ<br>~~S/H,~~|90typ<br>~~S/H,~~|91typ<br>~~S/H,~~| |**INRUSH CURRENT[A]**<br>~~|~~<br>~~Po~~<br>~~Lo~~|**ACIN 115V** <br>~~||~~<br>~~Po~~||||||| ||**ACIN 230V** <br>~~|~~<br>~~Po~~<br>~~ee~~||||||| |**LEAKAGE CURRENT[uA] **<br>~~ee~~<br>~~Lo~~|**ACIN 264V** <br>~~ee~~<br>~~ee~~||||||| |**TOUCH CURRENT[uA] **<br>~~Lo~~<br>~~—“(Cid~~|**ACIN 264V** <br>~~ee~~<br>~~—“(Cid~~||||||| |**VOLTAGE[V]**<br>~~ee~~<br>~~Lo~~<br>~~a ~~||5<br>~~ee~~<br> ~~CO~~|7.5<br>~~CO~~|12<br>~~CO~~|15<br>~~CO~~|24<br>~~CO~~|36<br>~~CO~~| |**CURRENT[A]**<br>~~PO~~||6<br>~~PO~~|5.5<br>~~PO~~|4.5<br>~~PO~~|3.5<br>~~PO~~|2.5<br>~~PO~~|1.7<br>~~PO~~| |**WATTAGE[W]**<br>~~GO~~||30<br>~~GO~~|41.25<br>~~GO~~<br>~~GD~~|54<br>~~GO~~<br>~~(OOO~~|52.5<br>~~GO~~<br>~~(OOO~~|60<br>~~GO~~<br>~~(OOO~~|61.2<br>~~GO~~| |**LINE REGULATION[mV]**<br>*1 <br>~~GD~~||20max<br>~~GD~~|36max<br>~~GD~~<br>~~GD~~|48max<br>~~GD~~<br>~~(OOO~~|60max<br>~~GD~~<br>~~(OOO~~|96max<br>~~GD~~<br>~~(OOO~~|144max<br>~~GD~~| |**LOAD REGULATION[mV]** *1 <br>~~||~~<br>~~|~~||100max|120max<br>~~GD~~|120max<br>~~(OOO~~|120max<br>~~(OOO~~|150max<br>~~(OOO~~|240max| |**RIPPLE NOISE[mVp-p]** *2 <br>~~|~~|**lo=100%** <br>~~||~~||||||| |**TEMPERATURE REGULATION[mV] **<br>~~|~~|**0~+50**C <br>~~||~~|100max|100max|120max|180max|240max|360max| |**START-UP TIME[ms]**<br>~~PO~~|**ACIN 115V** <br>~~|~~<br>~~PO~~||||||| ||<br>**ACIN 230V**<br>~~PO~~||||||| |**HOLD-UP TIME[ms]**<br>~~PE~~<br>~~|~~<br>~~J~~|**ACIN 115V** <br>~~PE~~<br>~~|~~<br>||||||| ||**ACIN 230V** <br>~~PE~~<br>~~|~~<br>||||||| |**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]** <br>~~|~~<br>~~J~~<br>~~[~~|||||||| |**OUTPUT VOLTAGE SETTING[V]**<br>~~|~~<br>~~JGD~~<br>~~[~~||4.90 to 5.30<br>~~GD~~<br>|7.20 to 7.80<br>~~GD~~<br>~~GD~~<br>|11.50 to 12.50<br>~~GD~~<br>~~DO~~<br>|14.40 to 15.60<br>~~GD~~<br>~~GO~~<br>|23.00 to 25.00<br>~~GD~~<br>|34.50 to 37.50<br>~~GD~~<br>| |**OVERCURRENT PROTECTION[A]**<br>~~[~~|||||||| |**OVERVOLTAGE PROTECTION[V]**<br>~~[PO~~<br>~~|~~||5.75 to 7.00<br>~~PO~~|8.63 to 10.50<br>~~GD~~<br>~~PO~~|13.80 to 16.80<br>~~DO~~<br>~~PO~~|17.25 to 21.00<br>~~GO~~<br>~~PO~~|27.60 to 33.60<br>~~PO~~|41.40 to 50.40<br>~~PO~~| |**INPUT-OUTPUT**<br>~~||~~|||||||| |**INPUT-FG**<br>~~||~~|||||||| |**OUTPUT-FG**<br>~~|Ls~~<br>~~|~~|||||||| |**OPERATING TEMP.,HUMID.** *3 <br>~~||~~|||||||| |**STORAGE TEMP.,HUMID.**<br>~~||~~<br>~~JF~~|||||||| |**VIBRATION**<br>~~|~~<br>~~JF|~~|||||||| |**IMPACT**<br>~~JF|~~<br>C—“‘CS:*sSCSC~s*zY|||||||| |**AGENCY APPROVALS**<br>~~|~~|||||||| |**EMC EMISSON**<br>~~[|~~<br>~~J~~|||||||| |**EMC EMMUNITY**<br>~~J|~~<br>~~tt:~C‘CsCSC‘szCS~~|||||||| |**HARMONIC ATTENUATOR***6 <br>~~J|~~<br>~~tt:~C‘CsCSC‘szCS~~<br>~~|~~|||||||| |**CASE SIZE/WEIGHT***7 <br>~~|~~<br>~~tt:~C‘CsCSC‘szCS~~<br>~~||~~|||||||| |**COOLING METHOD**<br>~~||~~<br>C(i‘“C;SCSCSCs*zr|||||||| |**WARRANTY**<br>*4<br>~~|~~<br>~~Pe~~|||||||| - *1 Consult us about dynamic load and input response. Measure the output voltage by using the average mode of the tester to deal with the burst operation at low (Io=0~20%Atyp) load. - *2 This is the result of measurement of the testing board with capacitors of 47μF and 0.1μF placed at 150 mm from the output terminals by a 20MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-GikenRM104. When the load factor is low (Io=0~20%Atyp), the switching power loss is reduced by burst operation, which will cause ripple noise to go beyond the specifications. - *3 Output power derating is required. Refer to "Derating" - *4 Consult us about details. *5 The listed options may affect the published standard specifications. Please contact us for detailed product specifications and safety approvals. *6 Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details. - *7 Dimensions below PCB are not included. * All parameters not specially mentioned are measured at ACIN 230V, rated load and 25℃ of ambient temperature. * Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is not possible with this model. - Acoustic noise may be heard from the power supply when used for pulse load. **UMA-4** October 10, 2023 **UMA60F** **UMA** ## **External view** ~~a~~ **==> picture [505 x 625] intentionally omitted <==** **----- Start of picture text -----**<br> Voltage adjust<br>Name plate (Optional -Y)<br> (Display item)<br>Model name<br>Rated Input/Output<br>Production Country<br>Lot No.<br>Safety Agency Mark Logo 20<br>Company Logo [0.79]<br>1<br>AC(L) 3 2 -V<br>AC(N) 1 34 +V<br>CN1 CN2 Mating connector and terminal of CN1, CN2<br>I/O Connector Mating Connector Terminal Mfr.<br>Reel : SVH-21T-P1.1<br>CN1 B2P3-VH VHR-3N pieceLoose [ : BVH-21T-P1.1] J.S.T.<br>FG1 4- 3.3 [ 0.13] CN2 B4P-VH VHR-4N Chain : SVH-21T-P1.1Loosepiece : BVH-21T-P1.1 J.S.T.<br>Mounting Hole<br>3.2 69.8 ±0.5<br>[0.13] [2.75]<br><Pin Assignments><br>CN1 CN2<br>76.2<br>[3] Pin No. Input Pin No. Output<br>1 AC(N) 1, 2 -V<br>2<br>3 AC(L) 3, 4 +V<br>ee ===<br>=<br> Dimensions in mm, [ ] =inches<br> Tolerance : ±1 [±0.04]<br> Weight : 120g max<br> PCB Material/thickness : FR-4/1.6 [0.06]<br>1 The mounting hole is for FG connection.<br>The mounting hole in the -E option is not for FG connection.<br>a Derating Curve<br>100 100<br>90 90<br>80 5V, 7.5V, 12V, 15V 80<br>70 70<br>24V, 36V, 48V<br>60 ew ee‘ 60<br>50 50<br>40 Pt | | | tt 40<br>30 Pt | | | tt 30<br>20 Pt | | | tt 20<br>10 Pt | | | tt 10<br>0 Pt | | | ft [tt] 0<br>Hace iz 85 115 264<br>-20 -10 0 10 20 30 40 50 60 70<br>Ambient temperature ( ) Input Voltage(VAC)<br>*The shaded area is the derating required at start-up. Fig.2 Derating curve depending on input voltage<br>Fig.1 Derating curve depending on ambient temperature<br>19 [0.75]<br>50.8 [2] 44.4 ±0.5 [1.75]<br>3.2 [0.13]<br>24.2 [0.95]<br>2.5max [0.1max]<br>Load factor (%) Load factor (%)<br>**----- End of picture text -----**<br> ■The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be influenced by the heat from the power supply. Please consult us for more details. **UMA-5** October 10, 2023 ## **UMA-series** ## | **UMA** ## **Assembling and Installation Method** - ■When the power supply is used with natural convection cooling, the standard mounting position is horizontal. **==> picture [501 x 397] intentionally omitted <==** **----- Start of picture text -----**<br> standard mounting position is horizontal. d1<br>CN1<br>d2<br>| :<br>Side view<br>■AC voltage exists on the primary side. Therefore, in order to prevent<br>d3<br>electric shock, or to meet the leakage current requirements of the<br>safety standard, you need to ensure the proper insulation distance.<br>CN1<br>d1=5mm min<br>d2=8mm min<br>d3=5mm min<br>d3<br>Top view<br>Mounting screw<br>■The mounting screws should be M3. 7mm 7mm<br> The hatched area indicates the proper area for mounting hardware. <a a<br>■This power supply is manufactured by SMD technology.<br>Fe R3.5 R3.5 at<br>Stress to the PCB such as twisting or bending may cause damage<br>to the unit, please handle with care.<br>CN1<br>R3.5 R3.5<br>※* 1 FG<br>t f<br>SHe 7mm 7mm SHe<br>* Recommend to electrically connect FG to metal chassis for<br>reducing noise.<br>d3 d3<br>7mm 7mm<br>7mm 7mm<br>**----- End of picture text -----**<br> ## **Instruction Manual** - ■Please read the“Instruction Manual”and“Before using our product”before you use our product. Instruction Manual https://en.cosel.co.jp/product/powersupply/UMA/ Before using our product https://en.cosel.co.jp/technical/caution/index.html **==> picture [83 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> UMA NOTICE<br>**----- End of picture text -----**<br> ## **Basic Characteristics Data** |Model|Circuit method|Switching<br>frequency<br>[kHz]|Input<br>current<br>[A]|Rated<br>input fuse|Inrush<br>current<br>protection<br>circuit|PCB/Pattern|PCB/Pattern|PCB/Pattern|Parallel<br>operation| |---|---|---|---|---|---|---|---|---|---| |||||||Material|Single<br>sided|Double<br>sided|| |UMA30F|Flyback converter|20 to 125|0.7|250V 2.5A|Thermistor|CEM-3|Yes||No| |UMA60F|Flyback converter|20 to 125|1.4|250V 2.5A|Thermistor|FR4||Yes|No| **==> picture [26 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> UMA-6<br>**----- End of picture text -----**<br> October 10, 2023
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →