Image not available
Illustrative purposes only
UHP-500R-36
AC/DC Enclosed Power Supply (PSU), ITE & Household, 1 Outputs, 500.4 W, 36 VDC, 13.9 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:500.4W; Output Voltage - Output 1:36V; Output Current - Output 1:13.9A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage
- SVHC: No SVHC (25-Jun-2025)
- Product Range: UHP-500 Series
- No. of Outputs: 1Outputs
- Output Power Max: 500.4W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 13.9A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 36VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Household
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 87.44 € |
| Current stock | 10+ |
| Lead time | 30 days |
500W Slim Type with PFC Switching Supply ## **UHP - 500 series** **==> picture [43 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> **==> picture [17 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> Video<br>**----- End of picture text -----**<br> **==> picture [200 x 28] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br> GB4943 UL62368-1 BS EN/EN62368-1 www.ID 2000000000tuv.com IEC62368-1<br>**----- End of picture text -----**<br> ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧-~+℃ - ‧ - - ‧ - ‧ ## ■ **** - ‧Industrial automation machinery - ‧Industrial control system - ‧Mechanical and electrical equipment - ‧Electronic instruments, equipments or apparatus - ‧LED display application - ‧Power Source Equipment for PoE(55V model) ## ■ **** - - ‧ - ‧ ## ■ **** ℃℃ ## ■ **** ** ** |||| |---|---|---| |||| |R||| _File Name:UHP-500-SPEC 2022-08-04_ 500W Slim Type with PFC Switching Supply ## **UHP - 500 series** ## **SPECIFICATION** |3.6~4.4V<br>**VOLTAGE ADJ. RANGE Note.7**<br>110~140% rated output power<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 50ms/230VAC; 1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time<br>90 ~ 264VAC 127 ~ 370VDC<br>Cold start 30A/115VAC 60A/230VAC<br><0.75mA / 240VAC<br>4.62 ~ 5.46V<br>-30 ~ +70℃(Refer to “Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH non-condensing<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>1264.1 K hrs min. Telcordia SR-332 (Bellcore) ; 167.6K hrs min. MIL-HDBK-217F (25℃)<br>PF<br>0.95/230VAC PF<br>0.98/115VAC at full load<br>≥<br>≥<br>12ms/230VAC 12ms/115VAC<br>±1.0%<br>±0.5%<br>±2.0%<br>200mVp-p<br>4.2V<br>**UHP-500 -4.2**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>℃<br><br><br><br><br><br><br><br><br>℃<br>The <br><br>The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed<br>that it still meets EMC directives.<br><br><br><br><br>※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>**ENVIRONMENT**<br>**PROTECTION**<br>232*81*31mm (L*W*H)<br>Protection type :Shut down O/P voltage,re-power on to recover<br>Protection type :Shut down O/P voltage, recovers automatically after temperature goes down<br>4.85A/115VAC 2.6A/230VAC<br>**RATED POWER**<br>0.905kg; 16pcs/15.48kg/0.82CUFT<br>47 ~ 63Hz<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>4.5~5.5V<br>±1.0%<br>±0.5%<br>±2.0%<br>200mVp-p<br>5V<br>11.4~12.6V<br>±0.5%<br>±0.3%<br>±1.0%<br>200mVp-p<br>12V<br>14.3~15.8V<br>200mVp-p<br>15V<br>22.8~25.2V<br>240mVp-p<br>24V<br>34.2~37.8V<br>360mVp-p<br>36V<br>45.6~50.4V<br>360mVp-p<br>48V<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>39.6 ~46.8V<br>13.2 ~ 15.6V<br>5.75 ~ 6.75V<br>16.5 ~ 19.5V<br>26.4 ~ 31.2V<br>52.8 ~ 62.4V<br>**UHP-500 -5**<br>**UHP-500 -12**<br>**UHP-500 -15 UHP-500 -24**<br>**UHP-500 -36**<br>**UHP-500 -48**<br>**FUNCTION**<br>**REDUNDANT(Optional)**<br>Contact rating(max.):30Vdc/1A resistive load<br>For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be<br>automatically enabled. This can prevent the system crash, and provide the reliability of system<br>**DC OK SIGNAL(Optional)**<br>**SAFETY STANDARDS**<br>**EMC EMISSION**<br>**EMC IMMUNITY**<br>Compliance to BS EN/EN55032,GB/T9254,Class B, BS EN/EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,<br>heavy industry level ,EAC TP TC 020<br>UL 62368-1,TUV BS EN/EN62368-1,BS EN/EN60335-1(Except for 55V), CCC GB4943, BSMI CNS14336-1,<br>EAC TP TC 004 approved;Design refer to BS EN/EN61558-2-16<br>80A<br>336W<br>80A<br>400W<br>41.7A<br>500.4W<br>33.4A<br>501W<br>20.9A<br>501.6W<br>13.9A<br>500.4W<br>501.6W<br>10.45A<br>**UHP-500 -55**<br>45~58V<br>500mVp-p<br>55V<br>±0.5%<br>±0.3%<br>±1.0%<br>500W<br>8.9A<br>89%<br>95%<br>94%<br>94%<br>94.5%<br>95%<br>90%<br>95%<br>60 ~ 69V<br>**INRUSH CURRENT(Typ.)Note9**|3.6~4.4V<br>**VOLTAGE ADJ. RANGE Note.7**<br>110~140% rated output power<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 50ms/230VAC; 1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time<br>90 ~ 264VAC 127 ~ 370VDC<br>Cold start 30A/115VAC 60A/230VAC<br><0.75mA / 240VAC<br>4.62 ~ 5.46V<br>-30 ~ +70℃(Refer to “Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH non-condensing<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>1264.1 K hrs min. Telcordia SR-332 (Bellcore) ; 167.6K hrs min. MIL-HDBK-217F (25℃)<br>PF<br>0.95/230VAC PF<br>0.98/115VAC at full load<br>≥<br>≥<br>12ms/230VAC 12ms/115VAC<br>±1.0%<br>±0.5%<br>±2.0%<br>200mVp-p<br>4.2V<br>**UHP-500 -4.2**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>℃<br><br><br><br><br><br><br><br><br>℃<br>The <br><br>The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed<br>that it still meets EMC directives.<br><br><br><br><br>※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>**ENVIRONMENT**<br>**PROTECTION**<br>232*81*31mm (L*W*H)<br>Protection type :Shut down O/P voltage,re-power on to recover<br>Protection type :Shut down O/P voltage, recovers automatically after temperature goes down<br>4.85A/115VAC 2.6A/230VAC<br>**RATED POWER**<br>0.905kg; 16pcs/15.48kg/0.82CUFT<br>47 ~ 63Hz<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>4.5~5.5V<br>±1.0%<br>±0.5%<br>±2.0%<br>200mVp-p<br>5V<br>11.4~12.6V<br>±0.5%<br>±0.3%<br>±1.0%<br>200mVp-p<br>12V<br>14.3~15.8V<br>200mVp-p<br>15V<br>22.8~25.2V<br>240mVp-p<br>24V<br>34.2~37.8V<br>360mVp-p<br>36V<br>45.6~50.4V<br>360mVp-p<br>48V<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>39.6 ~46.8V<br>13.2 ~ 15.6V<br>5.75 ~ 6.75V<br>16.5 ~ 19.5V<br>26.4 ~ 31.2V<br>52.8 ~ 62.4V<br>**UHP-500 -5**<br>**UHP-500 -12**<br>**UHP-500 -15 UHP-500 -24**<br>**UHP-500 -36**<br>**UHP-500 -48**<br>**FUNCTION**<br>**REDUNDANT(Optional)**<br>Contact rating(max.):30Vdc/1A resistive load<br>For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be<br>automatically enabled. This can prevent the system crash, and provide the reliability of system<br>**DC OK SIGNAL(Optional)**<br>**SAFETY STANDARDS**<br>**EMC EMISSION**<br>**EMC IMMUNITY**<br>Compliance to BS EN/EN55032,GB/T9254,Class B, BS EN/EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,<br>heavy industry level ,EAC TP TC 020<br>UL 62368-1,TUV BS EN/EN62368-1,BS EN/EN60335-1(Except for 55V), CCC GB4943, BSMI CNS14336-1,<br>EAC TP TC 004 approved;Design refer to BS EN/EN61558-2-16<br>80A<br>336W<br>80A<br>400W<br>41.7A<br>500.4W<br>33.4A<br>501W<br>20.9A<br>501.6W<br>13.9A<br>500.4W<br>501.6W<br>10.45A<br>**UHP-500 -55**<br>45~58V<br>500mVp-p<br>55V<br>±0.5%<br>±0.3%<br>±1.0%<br>500W<br>8.9A<br>89%<br>95%<br>94%<br>94%<br>94.5%<br>95%<br>90%<br>95%<br>60 ~ 69V<br>**INRUSH CURRENT(Typ.)Note9**|**UHP-500 -4.2**|**UHP-500 -5**|**UHP-500 -12**|**UHP-500 -15 **|**UHP-500 -24**|**UHP-500 -36**|**UHP-500 -48**|**UHP-500 -55**| |---|---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|4.2V|5V|12V|15V|24V|36V|48V|55V| ||**RATED CURRENT**|80A|80A|41.7A|33.4A|20.9A|13.9A|10.45A|8.9A| ||**RATED POWER**|336W|400W|500.4W|501W|501.6W|500.4W|501.6W|500W| ||**RIPPLE & NOISE (max.)Note.2**|200mVp-p|200mVp-p|200mVp-p|200mVp-p|240mVp-p|360mVp-p|360mVp-p|500mVp-p| ||**VOLTAGE ADJ. RANGE Note.7**|3.6~4.4V|4.5~5.5V|11.4~12.6V|14.3~15.8V|22.8~25.2V|34.2~37.8V|45.6~50.4V|45~58V| ||**VOLTAGE TOLERANCENote.3**|±2.0%|±2.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%|±0.3%|±0.3%|±0.3%|±0.3%|±0.3%|±0.3%| ||**LOAD REGULATION**|±1.0%|±1.0%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**SETUP, RISE TIME**|1000ms, 50ms/230VAC; 1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time|||||||| ||**HOLD UP TIME (Typ.)**|12ms/230VAC 12ms/115VAC|||||||| ||**VOLTAGE RANGE Note.4**|90 ~ 264VAC 127 ~ 370VDC|||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||||| ||**POWER FACTOR (Typ.)**|PF<br>0.95/230VAC PF<br>0.98/115VAC at full load<br>≥<br>≥|||||||| ||**EFFICIENCY (Typ.)**|89%|90%|94%|94%|94.5%|95%|95%|95%| ||**AC CURRENT (Typ.)**|4.85A/115VAC 2.6A/230VAC|||||||| ||**INRUSH CURRENT(Typ.)Note9**|Cold start 30A/115VAC 60A/230VAC|||||||| ||**LEAKAGE CURRENT**|<0.75mA / 240VAC|||||||| ||**OVERLOAD**|110~140% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||||||| ||**OVER VOLTAGE**|4.62 ~ 5.46V<br>Protection type :Shut down O/P voltage,re-power on to recover<br>39.6 ~46.8V<br>13.2 ~ 15.6V<br>5.75 ~ 6.75V<br>16.5 ~ 19.5V<br>26.4 ~ 31.2V<br>52.8 ~ 62.4V<br>60 ~ 69V|||||||| ||**OVER TEMPERATURE**|Protection type :Shut down O/P voltage, recovers automatically after temperature goes down|||||||| ||**DC OK SIGNAL(Optional)**|Contact rating(max.):30Vdc/1A resistive load|||||||| ||**REDUNDANT(Optional)**|For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be<br>automatically enabled. This can prevent the system crash, and provide the reliability of system|||||||| ||**WORKING TEMP.**|-30 ~ +70℃(Refer to “Derating Curve")|||||||| ||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing|||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85℃, 10 ~ 95% RH non-condensing|||||||| ||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)|||||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes|||||||| ||**SAFETY STANDARDS**|UL 62368-1,TUV BS EN/EN62368-1,BS EN/EN60335-1(Except for 55V), CCC GB4943, BSMI CNS14336-1,<br>EAC TP TC 004 approved;Design refer to BS EN/EN61558-2-16|||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC|||||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH|||||||| ||**EMC EMISSION**|Compliance to BS EN/EN55032,GB/T9254,Class B, BS EN/EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020|||||||| ||**EMC IMMUNITY**|Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,<br>heavy industry level ,EAC TP TC 020|||||||| ||**MTBF**|1264.1 K hrs min. Telcordia SR-332 (Bellcore) ; 167.6K hrs min. MIL-HDBK-217F (25℃)|||||||| ||**DIMENSION**|232*81*31mm (L*W*H)|||||||| ||**PACKING**|0.905kg; 16pcs/15.48kg/0.82CUFT|||||||| ||℃<br><br><br><br><br><br><br><br><br>℃<br>The <br><br>The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed<br>that it still meets EMC directives.<br><br><br><br><br>※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx||||||||| _File Name:UHP-500-SPEC 2022-08-04_ **UHP - 500 series** ## 500W Slim Type with PFC Switching Supply ## **Block Diagram** **==> picture [501 x 603] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc:60KHz<br>PWM fosc:65KHz~75KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & SWITCH- &<br>RECTIFIER CIRCUIT ING FILTER -V<br>FG DETECTION<br>CIRCUIT<br>O.T.P. O.L.P.<br>CONTROL<br>O.V.P.<br>DC OK Function<br>Redundant Function<br>Derating Curve<br>12V,15V 230Vac for 12V,15V<br>100 others 100 230Vac for other<br>90<br>230Vac for 4.2V,5V<br>80 4.2V,5V 80 110Vac for other 230Vac for 55V<br>70<br>60 60 110Vac for 4.2V,5V<br>50<br>40 40<br>30<br>20 20 110Vac for 55V<br>-30 0 10 20 30 40 45 50 60 70 (HORIZONTAL) -30 0 10 20 30 40 45 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ ) AMBIENT TEMPERATURE WITHOUT ALUMINUM PLATE( ℃ )<br>100<br>80<br>60<br>40<br>20<br>-30 0 10 20 30 40 50 60 70 80 90 (HORIZONTAL)<br>Tcase ( ℃ )<br>RATED CURRENT (%) RATED CURRENT (%)<br>RATED CURRENT (%)<br>**----- End of picture text -----**<br> _File Name:UHP-500-SPEC 2022-08-04_ **UHP - 500 series** 500W Slim Type with PFC Switching Supply ## **STATIC CHARACTERISTIC** **==> picture [195 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>60<br>50<br>40<br>90 100 110 120 140 160 180 200 220 240 264<br>INPUT VOLTAGE (V) 60Hz<br>LOAD (%)<br>**----- End of picture text -----**<br> ## **DC OK Relay Contact** |Contact Close|PSU turns on/DC ok| |---|---| |Contact Open|PSU turns off/DC fail| |Contact Rating(max.)|30Vdc/1A resistive load| ## **Redundant function** (1) UHP-500R is built-in redundant function and can be connected 2 units in parallel . (2) When in parallel operation the maximum load should not be greater than the rated power of any PSU. **==> picture [158 x 72] intentionally omitted <==** **----- Start of picture text -----**<br> +V<br>+V<br>PSU -V -V LOAD<br>+V<br>PSU -V<br>**----- End of picture text -----**<br> _File Name:UHP-500-SPEC 2022-08-04_ 500W Slim Type with PFC Switching Supply ## **UHP - 500 series** **==> picture [422 x 355] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>232<br>226 3<br>TB3<br>1<br>TB1<br>3 2<br>2<br>3<br>1 TB2<br>4<br>CN1<br>SVR<br>4-ψ4.2 L=6<br>116<br>t c<br>‧ : Max. Case Temperaturetc<br>9<br>9.0<br>7.62 63 81<br>1<br>2<br>15.5<br>31<br>**----- End of picture text -----**<br> **==> picture [108 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> CASE NO.:233D Unit:mm<br>**----- End of picture text -----**<br> |Pin No.<br>1<br>3<br>2<br>Assignment<br>AC/L<br>AC/N<br>AC Input Terminal(TB1) pin NO. Assignment<br>Terminal<br>(DEGSON)<br>Pin No.<br>1<br>2<br>Assignment<br>DC COM1<br>DC COM2<br>DC OK Connector(CN1):JST B2B-PH-K-S or requivalent<br>Mating Housing<br>JSTPHR-2<br>or requivalent<br>Terminal<br>JSTSPH-002T-P0.5S<br>or requivalent<br>DG28C-B-03P<br>Max mounting torque<br>5Kgf-cm|Pin No.<br>1<br>3<br>2<br>Assignment<br>AC/L<br>AC/N<br>AC Input Terminal(TB1) pin NO. Assignment<br>Terminal<br>(DEGSON)<br>Pin No.<br>1<br>2<br>Assignment<br>DC COM1<br>DC COM2<br>DC OK Connector(CN1):JST B2B-PH-K-S or requivalent<br>Mating Housing<br>JSTPHR-2<br>or requivalent<br>Terminal<br>JSTSPH-002T-P0.5S<br>or requivalent<br>DG28C-B-03P<br>Max mounting torque<br>5Kgf-cm|Pin No.<br>1<br>3<br>2<br>Assignment<br>AC/L<br>AC/N<br>AC Input Terminal(TB1) pin NO. Assignment<br>Terminal<br>(DEGSON)<br>Pin No.<br>1<br>2<br>Assignment<br>DC COM1<br>DC COM2<br>DC OK Connector(CN1):JST B2B-PH-K-S or requivalent<br>Mating Housing<br>JSTPHR-2<br>or requivalent<br>Terminal<br>JSTSPH-002T-P0.5S<br>or requivalent<br>DG28C-B-03P<br>Max mounting torque<br>5Kgf-cm|Pin No.<br>1<br>3<br>2<br>Assignment<br>AC/L<br>AC/N<br>AC Input Terminal(TB1) pin NO. Assignment<br>Terminal<br>(DEGSON)<br>Pin No.<br>1<br>2<br>Assignment<br>DC COM1<br>DC COM2<br>DC OK Connector(CN1):JST B2B-PH-K-S or requivalent<br>Mating Housing<br>JSTPHR-2<br>or requivalent<br>Terminal<br>JSTSPH-002T-P0.5S<br>or requivalent<br>DG28C-B-03P<br>Max mounting torque<br>5Kgf-cm|DC Output Terminal(TB2,TB3) pin NO. Assignment|DC Output Terminal(TB2,TB3) pin NO. Assignment|DC Output Terminal(TB2,TB3) pin NO. Assignment|DC Output Terminal(TB2,TB3) pin NO. Assignment| |---|---|---|---|---|---|---|---| |||||Pin No.|Assignment|Terminal|Max mounting torque| |||||1,2|-V|(MW)<br>MEL-400-02P<br>8Kgf-cm|| |||||3,4<br>+V|||| ||||||||| |Pin No.|Assignment|Mating Housing|Terminal||||| |1|DC COM1|JSTPHR-2<br>or requivalent|JSTSPH-002T-P0.5S<br>or requivalent||||| |2|DC COM2||||||| _File Name:UHP-500-SPEC 2022-08-04_ **UHP - 500 series** ## 500W Slim Type with PFC Switching Supply **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Installation<br>1.Operate with additional aluminum plate<br>In order to meet the“Derating Curve”and the “Static Characteristics” ,UHP-500 series must be installed onto an aluminum plate(or the cabinet of the same size)<br>on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and<br>smooth surface (or coated with thermal grease), and UHP-500 series must be firmly mounted at the center of the aluminum plate.<br>unit:mm<br>M3*4<br>450<br>450<br>3<br>**----- End of picture text -----**<br> _File Name:UHP-500-SPEC 2022-08-04_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →