Image not available
Illustrative purposes only
UHP-350-36
AC/DC Enclosed Power Supply (PSU), ITE & Household, 1 Outputs, 351 W, 36 VDC, 9.75 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:351W; Output Voltage - Output 1:36V; Output Current - Output 1:9.75A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage -
- SVHC: No SVHC (25-Jun-2025)
- Product Range: UHP-350 Series
- No. of Outputs: 1Outputs
- Output Power Max: 351W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 9.75A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 36VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Household
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 72.35 € |
| Current stock | 10+ |
| Lead time | 30 days |
**UHP - 350 series** 350W Slim Type with PFC Switching Power Supply **==> picture [226 x 32] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>C @ GB4943 Al; UL60950-1 4 EN60950-1 HI CBCE IEC60950-1<br> EN60335-1<br>**----- End of picture text -----**<br> ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧-~℃ - ‧ ## ■ **** - ‧Industrial automation machinery - ‧Industrial control system - ‧Mechanical and electrical equipment - ‧Electronic instruments, equipments or apparatus - ‧Household appliances - ‧LED display application - - ‧ - ‧ - ‧ - ‧ ## ■ **** ℃ ℃ ; ## ■ **** |****|****|****|****|****|****|||| |---|---|---|---|---|---|---|---|---| |****<br>****<br>****<br>****<br>[|<br>LC||||||||| |~~i~~|||||||<br><br><br><br>|| |||||||||| |||||||||| ||R|||||||| _File Name:UHP-350-SPEC 2019-01-18_ 350W Slim Type with PFC Switching Power Supply ## **UHP - 350 series** ## **SPECIFICATION** |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGENote.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR(Typ.)**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>2000ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>Cold start 30A/115VAC 60A/230VAC<br><0.75mA / 240VAC<br>-30 ~ +70℃(Refer to “Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH non-condensing<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>285 K hrs min. MIL-HDBK-217F (25℃)<br>PF<br>0.94/230VAC PF<br>0.98/115VAC at full load<br>≥<br>≥<br>10ms/230VAC 10ms/115VAC<br>89%<br>±1.0%<br>±0.5%<br>±2.0%<br>150mVp-p<br>4.2V<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>℃<br><br><br><br><br><br><br><br>℃℃<br><br><br><br>**ENVIRONMENT**<br>**PROTECTION**<br>94%<br>3.6~4.4V<br>**VOLTAGE ADJ. RANGE**<br>110~140% rated output power<br>220*62*31mm (L*W*H)<br>Protection type :Shut down O/P voltage,re-power on to recover<br>Protection type :Shut down O/P voltage, recovers automatically after temperature goes down<br>4A/115VAC 2A/230VAC<br>**RATED POWER(convection)**<br>0.68 kg;16 pcs/11.88 kg/0.63CUFT<br>47 ~ 63Hz<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>91%<br>4.5~5.5V<br>±1.0%<br>±0.5%<br>±2.0%<br>200mVp-p<br>5V<br>11.4~12.6V<br>±0.5%<br>±0.3%<br>±1.0%<br>200mVp-p<br>12V<br>14.3~15.8V<br>200mVp-p<br>15V<br>22.8~25.2V<br>240mVp-p<br>24V<br>34.2~37.8V<br>240mVp-p<br>36V<br>45.6~50.4V<br>240mVp-p<br>48V<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>90%<br>92%<br>94%<br>94%<br>**FUNCTION**<br>**DC OK SIGNAL(Optional)**<br>**REDUNDANT(Optional)**<br>Contact rating(max.):15Vdc/10mA resistive load<br>For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be<br>automatically enabled. This can prevent the system crash, and provide the reliability of system<br>**SAFETY STANDARDS**<br>**EMC EMISSION**<br>**EMC IMMUNITY**<br>Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH<br>Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020<br>UL60950-1,TUV EN60950-1,EN60335-1,CCC GB4943,BSMI CNS14336-1,EAC TP TC 004 approved,Design refer to EN61558-1,-2-16<br>60A<br>252W<br>60A<br>300W<br>29.2A<br>350.4W<br>23.4A<br>351W<br>14.6A<br>350.4W<br>9.75A<br>351W<br>7.3A<br>350.4W<br>4.62 ~ 5.46V<br>39.6 ~46.8V<br>13.2 ~ 15.6V<br>5.75 ~ 6.75V<br>16.5 ~ 19.5V<br>26.4 ~ 31.2V<br>52.8 ~ 62.4V<br>88.5%<br>3.8 ~ 4.6V<br>3.2~3.5V<br>±0.5%<br>±2.0%<br>150mVp-p<br>3.3V<br>**UHP-350 -4.2**<br>**UHP-350 -5**<br>**UHP-350 -12**<br>**UHP-350 -15**<br>**UHP-350 -24**<br>**UHP-350 -36**<br>**UHP-350 -48**<br>**UHP-350 -3.3**<br>60A<br>198W<br>±1.0%|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGENote.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR(Typ.)**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>2000ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>Cold start 30A/115VAC 60A/230VAC<br><0.75mA / 240VAC<br>-30 ~ +70℃(Refer to “Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH non-condensing<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>285 K hrs min. MIL-HDBK-217F (25℃)<br>PF<br>0.94/230VAC PF<br>0.98/115VAC at full load<br>≥<br>≥<br>10ms/230VAC 10ms/115VAC<br>89%<br>±1.0%<br>±0.5%<br>±2.0%<br>150mVp-p<br>4.2V<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>℃<br><br><br><br><br><br><br><br>℃℃<br><br><br><br>**ENVIRONMENT**<br>**PROTECTION**<br>94%<br>3.6~4.4V<br>**VOLTAGE ADJ. RANGE**<br>110~140% rated output power<br>220*62*31mm (L*W*H)<br>Protection type :Shut down O/P voltage,re-power on to recover<br>Protection type :Shut down O/P voltage, recovers automatically after temperature goes down<br>4A/115VAC 2A/230VAC<br>**RATED POWER(convection)**<br>0.68 kg;16 pcs/11.88 kg/0.63CUFT<br>47 ~ 63Hz<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>91%<br>4.5~5.5V<br>±1.0%<br>±0.5%<br>±2.0%<br>200mVp-p<br>5V<br>11.4~12.6V<br>±0.5%<br>±0.3%<br>±1.0%<br>200mVp-p<br>12V<br>14.3~15.8V<br>200mVp-p<br>15V<br>22.8~25.2V<br>240mVp-p<br>24V<br>34.2~37.8V<br>240mVp-p<br>36V<br>45.6~50.4V<br>240mVp-p<br>48V<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>±0.5%<br>±0.3%<br>±1.0%<br>90%<br>92%<br>94%<br>94%<br>**FUNCTION**<br>**DC OK SIGNAL(Optional)**<br>**REDUNDANT(Optional)**<br>Contact rating(max.):15Vdc/10mA resistive load<br>For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be<br>automatically enabled. This can prevent the system crash, and provide the reliability of system<br>**SAFETY STANDARDS**<br>**EMC EMISSION**<br>**EMC IMMUNITY**<br>Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH<br>Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020<br>UL60950-1,TUV EN60950-1,EN60335-1,CCC GB4943,BSMI CNS14336-1,EAC TP TC 004 approved,Design refer to EN61558-1,-2-16<br>60A<br>252W<br>60A<br>300W<br>29.2A<br>350.4W<br>23.4A<br>351W<br>14.6A<br>350.4W<br>9.75A<br>351W<br>7.3A<br>350.4W<br>4.62 ~ 5.46V<br>39.6 ~46.8V<br>13.2 ~ 15.6V<br>5.75 ~ 6.75V<br>16.5 ~ 19.5V<br>26.4 ~ 31.2V<br>52.8 ~ 62.4V<br>88.5%<br>3.8 ~ 4.6V<br>3.2~3.5V<br>±0.5%<br>±2.0%<br>150mVp-p<br>3.3V<br>**UHP-350 -4.2**<br>**UHP-350 -5**<br>**UHP-350 -12**<br>**UHP-350 -15**<br>**UHP-350 -24**<br>**UHP-350 -36**<br>**UHP-350 -48**<br>**UHP-350 -3.3**<br>60A<br>198W<br>±1.0%|**UHP-350 -3.3**|**UHP-350 -4.2**|**UHP-350 -5**|**UHP-350 -12**|**UHP-350 -15**|**UHP-350 -24**|**UHP-350 -36**|**UHP-350 -48**| |---|---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|3.3V|4.2V|5V|12V|15V|24V|36V|48V| ||**RATED CURRENT**|60A|60A|60A|29.2A|23.4A|14.6A|9.75A|7.3A| ||**RATED POWER(convection)**|198W|252W|300W|350.4W|351W|350.4W|351W|350.4W| ||**RIPPLE & NOISE (max.) Note.2**|150mVp-p|150mVp-p|200mVp-p|200mVp-p|200mVp-p|240mVp-p|240mVp-p|240mVp-p| ||**VOLTAGE ADJ. RANGE**|3.2~3.5V|3.6~4.4V|4.5~5.5V|11.4~12.6V|14.3~15.8V|22.8~25.2V|34.2~37.8V|45.6~50.4V| ||**VOLTAGE TOLERANCENote.3**|±2.0%|±2.0%|±2.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%|±0.5%|±0.3%|±0.3%|±0.3%|±0.3%|±0.3%| ||**LOAD REGULATION**|±1.0%|±1.0%|±1.0%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**SETUP, RISE TIME**|2000ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load|||||||| ||**HOLD UP TIME(Typ.)**|10ms/230VAC 10ms/115VAC|||||||| ||**VOLTAGE RANGENote.4**|90 ~ 264VAC 127 ~ 370VDC|||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||||| ||**POWER FACTOR(Typ.)**|PF<br>0.94/230VAC PF<br>0.98/115VAC at full load<br>≥<br>≥|||||||| ||**EFFICIENCY(Typ.)**|88.5%|89%|90%|91%|92%|94%|94%|94%| ||**AC CURRENT (Typ.)**|4A/115VAC 2A/230VAC|||||||| ||**INRUSH CURRENT(Typ.)**|Cold start 30A/115VAC 60A/230VAC|||||||| ||**LEAKAGE CURRENT**|<0.75mA / 240VAC|||||||| ||**OVERLOAD**|110~140% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||||||| ||**OVER VOLTAGE**|Protection type :Shut down O/P voltage,re-power on to recover<br>4.62 ~ 5.46V<br>39.6 ~46.8V<br>13.2 ~ 15.6V<br>5.75 ~ 6.75V<br>16.5 ~ 19.5V<br>26.4 ~ 31.2V<br>52.8 ~ 62.4V<br>3.8 ~ 4.6V|||||||| ||**OVER TEMPERATURE**|Protection type :Shut down O/P voltage, recovers automatically after temperature goes down|||||||| ||**DC OK SIGNAL(Optional)**|Contact rating(max.):15Vdc/10mA resistive load|||||||| ||**REDUNDANT(Optional)**|For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be<br>automatically enabled. This can prevent the system crash, and provide the reliability of system|||||||| ||**WORKING TEMP.**|-30 ~ +70℃(Refer to “Derating Curve")|||||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85℃, 10 ~ 95% RH non-condensing|||||||| ||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)|||||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes|||||||| ||**SAFETY STANDARDS**|UL60950-1,TUV EN60950-1,EN60335-1,CCC GB4943,BSMI CNS14336-1,EAC TP TC 004 approved,Design refer to EN61558-1,-2-16|||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC|||||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH|||||||| ||**EMC EMISSION**|Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020|||||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020|||||||| ||**MTBF**|285 K hrs min. MIL-HDBK-217F (25℃)|||||||| ||**DIMENSION**|220*62*31mm (L*W*H)|||||||| ||**PACKING**|0.68 kg;16 pcs/11.88 kg/0.63CUFT|||||||| ||℃<br><br><br><br><br><br><br><br>℃℃<br><br><br>||||||||| _File Name:UHP-350-SPEC 2019-01-18_ **UHP - 350 series** ## 350W Slim Type with PFC Switching Power Supply ## **Block Diagram** **==> picture [496 x 569] intentionally omitted <==** **----- Start of picture text -----**<br> I/P EMI FILTER& PFC SWITCH-POWER RECTIFIERS& +V<br>RECTIFIER CIRCUIT ING FILTER -V<br>FG DETECTION<br>CIRCUIT<br>O.T.P. O.L.P.<br>CONTROL<br>O.V.P.<br>DC OK Function<br>Redundant Function<br>Derating Curve<br>230Vac for 12V~48V<br>100 100<br>230Vac for 3.3V~5V<br>80 80<br>70<br>60 60 110Vac for all model<br>40 40<br>20 20<br>-30 0 10 20 30 40 50 60 70 (HORIZONTAL) -20 0 10 20 30 40 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ ) AMBIENT TEMPERATURE WITHOUT ALUMINUM PLATE( ℃ )<br>100<br>80<br>60<br>40<br>20<br>-30 0 10 20 30 40 50 60 70 80 90 (HORIZONTAL)<br>Tcase ( ℃ )<br>RATED CURRENT (%) RATED CURRENT (%)<br>RATED CURRENT (%)<br>**----- End of picture text -----**<br> _File Name:UHP-350-SPEC 2019-01-18_ **UHP - 350 series** 350W Slim Type with PFC Switching Power Supply ## **STATIC CHARACTERISTIC** **==> picture [196 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>60<br>50<br>40<br>90 100 110 120 140 160 180 200 220 240 264<br>INPUT VOLTAGE (V) 60Hz<br>LOAD (%)<br>**----- End of picture text -----**<br> ## **Function Manual** ## **1.DC_OK Signal** DC_OK is a collector shorted signal. It is used by an optocoupler in the power supply which indicates the output status of the power supply as exhibited below. **==> picture [490 x 305] intentionally omitted <==** **----- Start of picture text -----**<br> +V DC OK +V<br>Optocoupler C-E Pin Conduction PSU turns on DC ok<br>Optocoupler C-E Pin Open PSU turns off DC fail<br>Optocoupler Rating(max.) 15Vdc/10mA resistive load<br>GND COM<br>PSU<br>2.Redundant function<br>(1) UHP-350R is built-in redundant function and can be connected 2 units in parallel .<br>(2) When in parallel operation the maximum load should not be greater than the rated power of any PSU.<br>+V<br>+V<br>PSU -V -V LOAD<br>+V<br>PSU -V<br>1K<br>C<br>E<br>**----- End of picture text -----**<br> _File Name:UHP-350-SPEC 2019-01-18_ ## 350W Slim Type with PFC Switching Power Supply ## **UHP - 350 series** ## **Mechanical Specification** CASE NO.:232C Unit:mm **==> picture [485 x 318] intentionally omitted <==** **----- Start of picture text -----**<br> 220<br>214 3<br>1 2<br>CN10<br>TB1 1<br>3 TB3<br>2<br>2<br>1 3<br>TB2<br>4<br>SVR<br>4-ψ3.3 L=6<br>110<br>tc<br>‧ : Max. Case Temperaturetc<br>7.8<br>9.25<br>8.5<br>7.62<br>10.9 46.4 62<br>15.5<br>31<br>**----- End of picture text -----**<br> AC Input Terminal(TB1) pin NO. Assignment Pin No. Assignment Terminal Max mounting torque 1 AC/L 2 AC/N DG28C(DEGSON)-B-03P 5Kgf-cm 3 DC OK Connector(CN10):JST B2B-PH-K-S or requivalent Pin No. Assignment Mating Housing Terminal 1 DC COM JST PHR-2 JST SPH-002T-P0.5S 2 DC OK +V or requivalent or requivalent DC Output Terminal(TB2,TB3) pin NO. Assignment Pin No. Assignment Terminal Max mounting torque 1,2 -V (MW) 3,4 +V TB-HTP-200-40A 8Kgf-cm _File Name:UHP-350-SPEC 2019-01-18_ **UHP - 350 series** ## 350W Slim Type with PFC Switching Power Supply ## **Installation** ## **1.Operate with additional aluminum plate** **==> picture [481 x 268] intentionally omitted <==** **----- Start of picture text -----**<br> In order to meet the“Derating Curve”and the “Static Characteristics” ,UHP-350 series must be installed onto an aluminum plate(or the cabinet of the same size)<br>on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and<br>smooth surface (or coated with thermal grease), and UHP-350 series must be firmly mounted at the center of the aluminum plate.<br>unit:mm<br>M3*4<br>450<br>450<br>3<br>**----- End of picture text -----**<br> _File Name:UHP-350-SPEC 2019-01-18_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →