Image not available
Illustrative purposes only
UHP-1000-24
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 1.008 kW, 24 VDC, 42 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: UHP-1000 Series
- No. of Outputs: 1Outputs
- Output Power Max: 1.008kW
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 42A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 260.43 € |
| Current stock | 10+ |
| Lead time | 30 days |
**UHP - 1000 series** 1000W Slim Type with PFC Switching Supply BauarSicherheitbeegelodwacmat geprufto ges g www.ID 2000000000tuv.com > E ~~S~~ **UL62368-1** Als **EN62368-1** ~~J~~ **TPTC004** HI CBCE **IEC62368-1** ## ■ ## ■ * - 30 ~+ 70 ℃ ## ■ Industrial automation machinery Industrial control system Mechanical and electrical equipment Electronic instruments, equipment or apparatus Test and measurement instrument Laser related machine Charging related equipment Household appliances ## ■ UHP-1000 series is a 1000W single-output slim type power supply with 41mm of low profile design. Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 12V,24V,36V and 48V. In addition to the high efficiency up to 96%, that the whole series operates from -30℃ ~ 70℃ under air convection without fan. UHP-1000 has the complete protection functions and 5G anti-vibration capability; It is complied with the international safety regulations such as TUV EN62368-1, UL62368-1, and design refers to EN61558-1 and EN60335-1. UHP-1000 series serves as a high performance power supply solution for various industrial applications. ## ■ _File Name:UHP-1000-SPEC 2019-07-29_ > 1000W Slim Type with PFC Switching Supply **UHP - 1000 series** MEAN WELL ~~OOOO~~ ## **SPECIFICATION** |**VOLTAGE ADJ. RANGE**<br>105~120% rated output power<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 50ms/230VAC 1000ms,50ms/115VAC at full load<br>90 ~ 264VAC 250 ~ 370VDC<br>Cold start 20A/115VAC 40A/230VAC<br><0.75mA / 240VAC<br>-30 ~ +70<br>(Refer to “Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>218.86K hrs min.<br>Telcordia SR-332 (Bellcore) ; 69.81K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>PF<br>0.95/230VAC PF<br>0.99/115VAC at full load<br>≥<br>≥<br>12ms/230VAC 12ms/115VAC<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>℃<br>includes set up tolerance,<br>derating curve<br>℃<br>℃<br>**ENVIRONMENT**<br>**PROTECTION**<br>240*115*41mm (L*W*H)<br>Protection type: Shut down O/P voltage, re-power on to recover<br>Protection type: Shut down O/P voltage, recovers automatically after temperature goes down<br>10.1A/115VAC 5.3A/230VAC<br>**RATED POWER(convection)**<br>1.74kg ; 8pcs/14.9kg/0.74CUFT<br>47 ~ 63Hz<br>Protection type: Constant current limiting with delay shutdown after 3 seconds, re-power on to recover<br>**FUNCTION**<br>**REMOTE ON/OFF CONTROL**<br>**AUXILIARY POWER**<br>**DC-OK SIGNAL**<br>Power ON: "Low" <0 ~ 0.5V or Short circuit Power OFF: "Hi" >2 ~ 5V or Open circuit<br>12V@0.5A tolerance 10%, ripple 150mVp-p<br>±<br>The TTL signal out, PSU turn on = 4.5 ~ 5.5V; PSU turn off = -0.1 ~ 0.5V. Please refer to the Function Manual.<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P: 3.75KVAC I/P-FG: 2KVAC O/P-FG: 1.25KVAC<br>I/P-O/P, I/P-FG,O/P-FG: 100M Ohms/500VDC/25<br>/ 70%RH<br>℃<br>UL62368-1, TUV EN62368-1,<br>approved; design refer to EN61558-1, EN60335-1<br>EAC TP TC 004<br>**MTBF**<br>**PACKING**<br>Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage<br>Please refer to the Function Manual.<br>Adjustment of constant current level is allowable to 20 ~ 100% of rated current.<br>Please refer to the Function Manual.<br>**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV) Note 5**<br>**OUTPUT CURRENT**<br>**PROGRAMMABLE(PC) Note 5**<br>**SHORT CIRCUIT**<br>Protection type: Constant current limiting with delay shutdown after 3 seconds, re-power on to recover<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61000-6-2<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32)<br>EN55032 (CISPR32)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-6-2<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class B<br>Class A<br>-----<br>By built-in potentiometer, SVR<br>150mVp-p<br>240mVp-p<br>300mVp-p<br>240mVp-p<br>48V<br>36V<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>94%<br>95%<br>96%<br>95.5%<br>14.5 ~ 16V<br>29 ~ 33V<br>59 ~ 66V<br>43.5 ~ 49V<br>**UHP-1000-12**<br>**UHP-1000-24**<br>**UHP-1000-36**<br>**UHP-1000-48**<br>960W<br>1008W<br>21A<br>28A<br>1008W<br>1008W<br>12V<br>24V<br>80A<br>42A<br>48~57.6V<br>12~14.4V<br>36~43.2V<br>24~28.8V<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 —_ofambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance:<br>line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the<br>for more details.<br>5. PV/PC functions when users do not use SVR.<br>6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies. ” (as available on http:/www.meanwell.com)<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**VOLTAGE ADJ. RANGE**<br>105~120% rated output power<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 50ms/230VAC 1000ms,50ms/115VAC at full load<br>90 ~ 264VAC 250 ~ 370VDC<br>Cold start 20A/115VAC 40A/230VAC<br><0.75mA / 240VAC<br>-30 ~ +70<br>(Refer to “Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>218.86K hrs min.<br>Telcordia SR-332 (Bellcore) ; 69.81K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>PF<br>0.95/230VAC PF<br>0.99/115VAC at full load<br>≥<br>≥<br>12ms/230VAC 12ms/115VAC<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>℃<br>includes set up tolerance,<br>derating curve<br>℃<br>℃<br>**ENVIRONMENT**<br>**PROTECTION**<br>240*115*41mm (L*W*H)<br>Protection type: Shut down O/P voltage, re-power on to recover<br>Protection type: Shut down O/P voltage, recovers automatically after temperature goes down<br>10.1A/115VAC 5.3A/230VAC<br>**RATED POWER(convection)**<br>1.74kg ; 8pcs/14.9kg/0.74CUFT<br>47 ~ 63Hz<br>Protection type: Constant current limiting with delay shutdown after 3 seconds, re-power on to recover<br>**FUNCTION**<br>**REMOTE ON/OFF CONTROL**<br>**AUXILIARY POWER**<br>**DC-OK SIGNAL**<br>Power ON: "Low" <0 ~ 0.5V or Short circuit Power OFF: "Hi" >2 ~ 5V or Open circuit<br>12V@0.5A tolerance 10%, ripple 150mVp-p<br>±<br>The TTL signal out, PSU turn on = 4.5 ~ 5.5V; PSU turn off = -0.1 ~ 0.5V. Please refer to the Function Manual.<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P: 3.75KVAC I/P-FG: 2KVAC O/P-FG: 1.25KVAC<br>I/P-O/P, I/P-FG,O/P-FG: 100M Ohms/500VDC/25<br>/ 70%RH<br>℃<br>UL62368-1, TUV EN62368-1,<br>approved; design refer to EN61558-1, EN60335-1<br>EAC TP TC 004<br>**MTBF**<br>**PACKING**<br>Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage<br>Please refer to the Function Manual.<br>Adjustment of constant current level is allowable to 20 ~ 100% of rated current.<br>Please refer to the Function Manual.<br>**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV) Note 5**<br>**OUTPUT CURRENT**<br>**PROGRAMMABLE(PC) Note 5**<br>**SHORT CIRCUIT**<br>Protection type: Constant current limiting with delay shutdown after 3 seconds, re-power on to recover<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61000-6-2<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32)<br>EN55032 (CISPR32)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-6-2<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class B<br>Class A<br>-----<br>By built-in potentiometer, SVR<br>150mVp-p<br>240mVp-p<br>300mVp-p<br>240mVp-p<br>48V<br>36V<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>94%<br>95%<br>96%<br>95.5%<br>14.5 ~ 16V<br>29 ~ 33V<br>59 ~ 66V<br>43.5 ~ 49V<br>**UHP-1000-12**<br>**UHP-1000-24**<br>**UHP-1000-36**<br>**UHP-1000-48**<br>960W<br>1008W<br>21A<br>28A<br>1008W<br>1008W<br>12V<br>24V<br>80A<br>42A<br>48~57.6V<br>12~14.4V<br>36~43.2V<br>24~28.8V<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 —_ofambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance:<br>line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the<br>for more details.<br>5. PV/PC functions when users do not use SVR.<br>6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies. ” (as available on http:/www.meanwell.com)<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**UHP-1000-12**|**UHP-1000-24**|**UHP-1000-24**|**UHP-1000-36**|**UHP-1000-36**|**UHP-1000-48**| |---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|12V|24V||36V||48V| ||**RATED CURRENT**|80A|42A||28A||21A| ||**RATED POWER(convection)**|960W|1008W||1008W||1008W| ||**RIPPLE & NOISE (max.) Note.2**|150mVp-p|240mVp-p||240mVp-p||300mVp-p| ||**VOLTAGE ADJ. RANGE**|By built-in potentiometer, SVR<br>48~57.6V<br>12~14.4V<br>36~43.2V<br>24~28.8V|||||| ||**VOLTAGE TOLERANCE Note.3**|±1.0%|±1.0%||±1.0%||±1.0%| ||**LINE REGULATION**|±0.5%|±0.5%||±0.5%||±0.5%| ||**LOAD REGULATION**|±0.5%|±0.5%||±0.5%||±0.5%| ||**SETUP, RISE TIME**|1000ms, 50ms/230VAC 1000ms,50ms/115VAC at full load|||||| ||**HOLD UP TIME (Typ.)**|12ms/230VAC 12ms/115VAC|||||| ||**VOLTAGE RANGE**<br>**Note.4**|90 ~ 264VAC 250 ~ 370VDC|||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||| ||**POWER FACTOR (Typ.)**|PF<br>0.95/230VAC PF<br>0.99/115VAC at full load<br>≥<br>≥|||||| ||**EFFICIENCY (Typ.)**|94%|95%||95.5%||96%| ||**AC CURRENT (Typ.)**|10.1A/115VAC 5.3A/230VAC|||||| ||**INRUSH CURRENT (Typ.)**|Cold start 20A/115VAC 40A/230VAC|||||| ||**LEAKAGE CURRENT**|<0.75mA / 240VAC|||||| ||**OVERLOAD**|105~120% rated output power<br>Protection type: Constant current limiting with delay shutdown after 3 seconds, re-power on to recover|||||| ||**SHORT CIRCUIT**|Protection type: Constant current limiting with delay shutdown after 3 seconds, re-power on to recover|||||| ||**OVER VOLTAGE**|Protection type: Shut down O/P voltage, re-power on to recover<br>14.5 ~ 16V<br>29 ~ 33V<br>59 ~ 66V<br>43.5 ~ 49V|||||| ||**OVER TEMPERATURE**|Protection type: Shut down O/P voltage, recovers automatically after temperature goes down|||||| ||**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV) Note 5**|Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage<br>Please refer to the Function Manual.|||||| ||**OUTPUT CURRENT**<br>**PROGRAMMABLE(PC) Note 5**|Adjustment of constant current level is allowable to 20 ~ 100% of rated current.<br>Please refer to the Function Manual.|||||| ||**REMOTE ON/OFF CONTROL**|Power ON: "Low" <0 ~ 0.5V or Short circuit Power OFF: "Hi" >2 ~ 5V or Open circuit|||||| ||**AUXILIARY POWER**|12V@0.5A tolerance 10%, ripple 150mVp-p<br>±|||||| ||**DC-OK SIGNAL**|The TTL signal out, PSU turn on = 4.5 ~ 5.5V; PSU turn off = -0.1 ~ 0.5V. Please refer to the Function Manual.|||||| ||**WORKING TEMP.**|-30 ~ +70<br>(Refer to “Derating Curve")<br>℃|||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50|||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes|||||| ||**SAFETY STANDARDS**|UL62368-1, TUV EN62368-1,<br>approved; design refer to EN61558-1, EN60335-1<br>EAC TP TC 004|||||| ||**WITHSTAND VOLTAGE**|I/P-O/P: 3.75KVAC I/P-FG: 2KVAC O/P-FG: 1.25KVAC|||||| ||**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|I/P-O/P, I/P-FG,O/P-FG: 100M Ohms/500VDC/25<br>/ 70%RH<br>℃|||||| |||**Parameter**||**Standard**||**Test Level / Note**|| |||Conducted||EN55032 (CISPR32)||Class B|| |||Radiated||EN55032 (CISPR32)||Class B|| |||Harmonic Current||EN61000-3-2||Class A|| |||Voltage Flicker||EN61000-3-3||-----|| |||EN55024 , EN61000-6-2|||||| |||**Parameter**||**Standard**||**Test Level / Note**|| |||ESD||EN61000-4-2||Level 3, 8KV air ; Level 2, 4KV contact|| |||Radiated||EN61000-4-3||Level 3|| |||EFT / Burst||EN61000-4-4||Level 3|| |||Surge||EN61000-6-2||2KV/Line-Line 4KV/Line-Earth|| |||Conducted||EN61000-4-6||Level 3|| |||Magnetic Field||EN61000-4-8||Level 4|| |||Voltage Dips and Interruptions||EN61000-4-11||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|| ||**MTBF**|218.86K hrs min.<br>Telcordia SR-332 (Bellcore) ; 69.81K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||||| ||**DIMENSION**|240*115*41mm (L*W*H)|||||| ||**PACKING**|1.74kg ; 8pcs/14.9kg/0.74CUFT|||||| ||℃<br>includes set up tolerance,<br>derating curve<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 —_ofambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance:<br>line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the<br>for more details.<br>5. PV/PC functions when users do not use SVR.<br>6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies. ” (as available on http:/www.meanwell.com)<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).||||||| ℃ /1000m with fanless models and of 5 ℃ _File Name:UHP-1000-SPEC 2019-07-29_ **UHP - 1000 series** 1000W Slim Type with PFC Switching Supply ## **BLOCK DIAGRAM** **==> picture [501 x 385] intentionally omitted <==** **----- Start of picture text -----**<br> PWM fosc : 55KHz<br>PFC fosc : 70KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P RECTIFIER& CIRCUIT SWITCHING FILTER& -V<br>O.L.P.<br>FG DETECTION<br>CIRCUIT PV/PC<br>O.L.P. PWM<br>CONTROL SHUT DOWN<br>O.V.P.<br>PFC O.T.P.<br>CONTROL REMOTE ON-OFF<br>REMOTE<br>CONTROL<br>ON-OFF<br>DC OK FUNCTION<br>STATIC CHARACTERISTIC EFFICIENCY VS LOAD (48V MODEL)<br>100 100<br>90 95<br>90<br>80<br>85<br>70 80<br>115VAC<br>75<br>60<br>70 230VAC<br>50 65<br>60<br>40<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>90 100 110 120 140 160 180 200 220 240 264 LOAD<br>INPUT VOLTAGE (V) 60Hz<br>EFFICIENCY (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> ## **DERATING CURVE** **==> picture [486 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> 230VAC for 12V 230VAC for 12V<br>100 100<br>230VAC for other 230VAC for other<br>80 80<br>60 60<br>110VAC 110VAC<br>50 50<br>20 20<br>-30 0 10 20 30 40 45 50 60 70 (HORIZONTAL) -30 0 10 20 30 40 45 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE WITH CONDUCTION COOLING( ℃ ) AMBIENT TEMPERATURE WITH FORCED AIR COOLING( ℃ )<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> **==> picture [237 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> 110VAC<br>80 for other 230VAC<br>70 for other<br>230VAC<br>60<br>for 12V<br>40<br>35<br>30 110VAC<br>20 for 12V<br>-30 0 10 20 30 40 45 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE WITH CONVECTION COOLING( ℃ )<br>LOAD (%)<br>**----- End of picture text -----**<br> **==> picture [239 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>40<br>20<br>-40 -25 0 20 45 55 65 75 90 (HORIZONTAL)<br>Tcase ( ℃ )<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:UHP-1000-SPEC 2019-07-29_ **UHP - 1000 series** 1000W Slim Type with PFC Switching Supply ## **FUNCTION MANUAL** **1.Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)** ※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL VOLTAGE. **==> picture [454 x 266] intentionally omitted <==** **----- Start of picture text -----**<br> CN80<br>2 1<br>1413<br>EXTERNAL<br>VOLTAGE (DC)<br>PIN4 -GND-signal PIN3 PV<br>12V 24V 36V 48V<br>14.4 28.8 43.2 57.6 100<br>Non-Linear<br>12 24 36 48 83.3<br>80<br>60<br>40<br>6 12 18 24<br>20<br>V<br>0 0 0 0 2.5 5 6 V 50 90 100 110 120<br>EXTERNAL VOLTAGE (DC) OUTPUT VOLTAGE (%)<br>OUTPUT VOLTAGE(V) OUTPUT CURRENT (%)<br>**----- End of picture text -----**<br> - ※ Caution: By factory default, the Output Voltage Programming is not activated, and _PV (pin1)_ and _PV-DIS(pin2)_ are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections’ diagrams, please keep _PV (pin1)_ and _PV-DIS(pin2)_ shorted ; otherwise the power supply will have no output. - ※ Caution: When this function is needed to activate, please keep PV(pin1) and PV-DIS(pin2) opened. ## **2.Output Current Programming (or, PC / remote current programming / dynamic current trim)** - ※ The output current can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE. **==> picture [444 x 153] intentionally omitted <==** **----- Start of picture text -----**<br> Iout<br>CN80<br>Non-linear Operating Area<br>2 1 100<br>1413 83.3<br>For 50~100% Vo<br>EXTERNAL<br>VOLTAGE (DC)<br>For 120% Vo<br>PIN12 -GND-signal PIN11 PC<br>20<br>V<br>1 1.83 5<br>EXTERNAL VOLTAGE(VDC)<br>OUTPUT CURRENT(%)<br>**----- End of picture text -----**<br> - ※ Caution: By factory default, the Output Current Programming is not activated, and _VCCS(pin13)_ and _PC-DIS(pin14)_ are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections’ diagrams, please keep _VCCS(pin13)_ and _PC-DIS(pin14)_ shorted ; otherwise, the power supply will have no output. - ※ Caution: When this function is needed to activate, please keep VCCS(pin13) and PV-DIS(pin14) opened. _File Name:UHP-1000-SPEC 2019-07-29_ 1000W Slim Type with PFC Switching Supply ## **UHP - 1000 series** ## **3.Remote ON-OFF Control** **==> picture [481 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> The power supply can be turned ON/OFF individually or along with other units in parallel by using the "Remote ON-OFF" function.<br>CN80 CN80<br>2 1 2 1<br>1413 1413<br>EXTERNAL<br>switch VOLTAGE (DC)<br>PIN8 -GND-signal PIN7 Remote ON-OFF PIN8-GND-signal PIN7 Remote ON-OFF<br>Remote ON-OFF Power Supply Status<br>“Low” <0~0.5V or Short circuit ON<br>“Hi” >2~5V or Open circuit OFF<br>**----- End of picture text -----**<br> ## **4.DC-OK Signal** DC-OK signal is a TTL level signal. The maximum sink current is 10mA and the maximum external voltage is 5.6V. **==> picture [309 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> CN80<br>2 1<br>1413<br>PIN9 DC-OK<br>Application<br>Circuit<br>PIN10 -GND-signal<br>DC-OK signal Power Supply Status<br>“Hi” >4.5~5.5V ON<br>“Low” <-0.1~0.5V OFF<br>**----- End of picture text -----**<br> _File Name:UHP-1000-SPEC 2019-07-29_ ## 1000W Slim Type with PFC Switching Supply ## **UHP - 1000 series** **==> picture [511 x 681] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No.:272A Unit:mm<br>240<br>232 4<br>TB2<br>1<br>2<br>TB1<br>3<br>3<br>2 TB3<br>1 4<br>5<br>6<br>1 13<br>SVR 2 14<br>4-ψ4.2 L=6 CN80<br>120<br>tc<br>�tc : Max. Case Temperature<br>AC Input Terminal(TB1) Pin NO. Assignment<br>DC Output Terminal (TB2,TB3) Pin NO. Assignment<br>Pin No. Assignment Terminal Max mounting torque Pin No. Assignment Terminal Max mounting torque<br>1 AC/L<br>2 AC/N T42-ES11-03DECA 13.8Kgf-cm 4,5,61,2,3 +V-V NEL-400(MW) 8Kgf-cm<br>3<br>※Control Pin No. Assignment(CN80): HRS DF11-14DP-2DS or equivalent<br>2 1<br>Mating Housing HRS DF11-14DS or equivalent<br>Terminal HRS DF11-**SC or equivalent<br>14 13<br>Pin No. Function Description<br>1,3 PV Connection for output voltage programming.<br>2 PV-DIS Short connecting between PV (pin1) and PV-DIS (pin2) if output voltage programming function is not activated.<br>4,8,10,12 GND (Signal) Negative output voltage signal.<br>Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin6).<br>5 +12V-AUX<br>The maximum load current is 0.5A. This output is not controlled by “Remote ON-OFF”.<br>Auxiliary voltage output GND.<br>6 GND-AUX<br>The signal return is isolated from the output terminals (+V & -V).<br>Remote The unit can turn the output ON/OFF by electrical signal or dry contact between Remote ON/OFF.<br>7<br>ON-OFF Short (0 ~ 0.5V): Power ON; Open (2 ~ 5V): Power OFF ; The maximum input voltage is 5.5V.<br>Low (-0.1 ~ 0.5V): When the Vout≦80%±5%.<br>9 DC-OK High (4.5 ~ 5.5V): When Vout≧80%±5%.<br>The maximum sink current is 10mA and only for output.<br>11 PC Connection for constant current level programming.<br>13 Vccs Positive output voltage signal.<br>14 PC-DIS Short connecting between Vccs (pin13) and PC-DIS (pin14) if output current programming function is not activated.<br>8<br>99 115<br>20.5<br>41<br>9<br>8.25<br>7<br>**----- End of picture text -----**<br> _File Name:UHP-1000-SPEC 2019-07-29_ **UHP - 1000 series** ## 1000W Slim Type with PFC Switching Supply ## **Operate with additional aluminum plate and fan** **==> picture [488 x 595] intentionally omitted <==** **----- Start of picture text -----**<br> In order to meet the “Derating Curve” and the “Static Characteristics” , UHP-1000 series can be installed onto an aluminum plate(or the cabinet of the same size)<br>on the bottom or apply forced air cooled solution. The size of the suggested aluminum plate and configuration of fan are shown as below. And for optimizing<br>thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and UHP-1000 series must be firmly mounted<br>at the center of the aluminum plate.<br>unit:mm<br>M3*4<br>120mm<br>23.5CFM<br>FAN<br>Air flow<br>direction<br>TB2<br>1<br>2<br>TB1<br>3<br>3<br>2 TB3<br>1 4<br>5<br>6<br>SVR<br>450<br>450<br>150mm<br>3<br>**----- End of picture text -----**<br> ## **INSTALLATION MANUAL** Please refer to : http://www.meanwell.com/manual.html _File Name:UHP-1000-SPEC 2019-07-29_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →