UCH600PS48
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 1 Output, 600 W, 90V AC to 264V AC, Fixed
- Manufacturer: XP POWER
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (15-Jan-2018)
- Product Range: UCH600 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3.1A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 600W
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 216.99 € |
| Current stock | 10+ |
| Lead time | 30 days |
UCH600 series ## 600W **Convection cooled** **AC-DC power supplies** Approved for medical and ITE applications, this range of convection cooled single output AC/DC power supplies are packaged in an ultra compact footprint of just 203.2 x 127.0 mm. The UCH600 provides up to 600W convection-cooled leading to very high power density of 9.5W/in[3] . A 12V/0.6A fan supply is included in the design to faciliate system cooling, if required, along with 5V/1A standby output. The power supply contains two fuses and low leakage currents as required by medical device applications. The low profile and safety approvals covering ITE and medical standards along with conducted emissions to EN55011/32 level B allow the versatile UCH600 series to be used in a vast range of applications. ## **Features** - f 600W convection cooled - f 203.2 x 127.0 x 40.0 mm U channel - f Suitable for BF applications **==> picture [145 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> Applications<br>je A<br>Healthcare Robotics Instrumentation<br>**----- End of picture text -----**<br> ## **Dimensions** 203.2 x 127.0 x 40.0 mm (8.00” x 5.00” x 1.57”) - f ITE and medical (BF) approvals - f Class B conducted & radiated emissions - f Power density 9.5W/in³ - f High efficiency, up to 95% - f 5V 1.0A standby - f Remote On/Off Medical diagnostic ## **Documentation** For further information click the link or scan the code xppower.com - f -20°C to +70°C operating temperature - f 3 year warranty ## **Models & ratings** |Model number|Output power|Output voltage|Output current|Standby output|Fan output(1,3)|Efficiency(2)| |---|---|---|---|---|---|---| |UCH600PS12|600W|12.0V|50.0A|5V/1.0A|12V/0.6A|93%| |UCH600PS24|600W|24.0V|25.0A|5V/1.0A|12V/0.6A|95%| |UCH600PS36|600W|36.0V|16.6A|5V/1.0A|12V/0.6A|95%| |UCH600PS48|600W|48.0V|12.5A|5V/1.0A|12V/0.6A|95%| Notes: 1. Typical voltage, actual regulated voltage will be in range of 11.4V to 12.6V. 2. Typical efficiencies measured at 100% load and 230VAC input. 3. Regulation of the fan output requires a minimum load of 10W on the main output. 1 C4 **AC-DC power supplies** ## UCH600 series ## **Input** **==> picture [553 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Input voltage - operating|80|115/230|264|VAC|| |Input frequency|47|50/60|63|Hz|| |Power factor||>0.9|||230VAC, 100% load. EN61000-3-2 class A, class C >150W| |Input current - full load||6.0/3.0||A|115/230 VAC| |Inrush current|||60|A|230 VAC cold start, 25°C| |Earth leakage current||80/140|300|µA|115/230VAC/50Hz (Typ), 264VAC/60Hz (Max)| |No load input power|||1.5|W|When main output is Inhibited| |Input protection|F12A/250 V Internal fuse ftted in line and neutral.||||| ## **Output** **==> picture [553 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Output voltage - V1|12||48|VDC|See models and ratings table| |Initial set accuracy|||±1|%|50% load, 115/230VAC| |Minimum load|0|||A|No minimum load required| |Start up delay|||2|s|115/230VAC full load.| |Hold up time|10|||ms|Min at full load, 115VAC| |Drift|||±0.02|%|After 20 min warm up| |Line regulation|||±0.5|%|90-264VAC| |Load regulation|||±0.5|%|0-100% load| |Transient response|||4|%|Recovery within 1% in less than 500µs for a 50-75% and 75-50% load<br>step| |Over/undershoot||5||%|Full load| |Ripple & noise|||1.5/1|% pk-pk|20MHz bandwidth and 47µF electrolytic capacitator in parallel with<br>0.1µF ceramic capacitator 12V/other models.| |Overvoltage protection|110||130|%|Vnom, recycle input to reset| |Overload protection|110||130|% Inom|| |Short circuit protection|Trip & restart||||| |Temperature coeffcient|||0.02|%/˚C|| |Overtemperature protection|||||Measured internally, Auto Resetting| |Output leakage current|||50|µA|264VAC/60Hz| |Remote On/Off|Connect CN202 pin 3 to pin 2 to inhibit output||||| ## **Output - 5V standby** |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Output voltage||5||VDC|| |Initial set accuracy||±1||%|50% load, 115/230VAC| |Minimum load|0|||A|No minimum load required| |Start up delay|||0.5|s|115/230VAC full load.| |Hold up time|500|||ms|Min at full load, 115VAC| |Drift|||±0.02|%|After 20 min warm up| |Line regulation|||±0.5|%|90-264VAC| |Load regulation|||1|%|0-100% load| |Transient response|||4|%|Recovery within 1% in less than 500µs for a 50-75% and 75-50% load<br>step| |Over/undershoot||5||%|Full load| |Ripple & noise|||2|% pk-pk|20MHz bandwidth and 47µF electrolytic capacitator in parallel with<br>0.1µF ceramic capacitator| |Overload protection|||2|A|| |Short circuit protection|Trip & restart||||| |Temperature coeffcient|||0.02|%/˚C|| Specifications subject to change without notice. 2 **AC-DC power supplies** ## UCH600 series ## **General** **==> picture [554 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>Efficiency 95 % 230VAC, full load (see fig. 1 & 2)<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Effciency||95||%|230VAC, full load (see fg. 1 & 2)| |Isolation: input to output<br>input to ground<br>output to ground|4000|||VAC|2 x MOPP| ||1500|||VAC|1 x MOPP| ||1500|||VAC|1 x MOPP| |Switching frequency|37||120|kHz|PFC, variable| ||76||106||Main converter, variable| |||100|||5V standby output| |Power density|||9.5|W/in3|| |Mean time between failure||300||khrs|MIL-HDBK-217F, Notice 2 +25°C GB.| |Weight||1.1 (2.43)||kg (lb)|| ## **EMC: Emissions** |Phenomenon|Standard|Test level|Notes & conditons| |---|---|---|---| |Conducted|EN55011/EN55032|Class B|| |Radiated|EN55011/EN55032|Class B|| |Harmonic currents|EN61000-3-2|Class A|Class C for Load >150W| |Voltage ficker|EN61000-3-3||| ## **EMC: Immunity** **==> picture [553 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Criteria Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Criteria|Notes & conditons| |---|---|---|---|---| |||||| |Medical device EMC|IEC60601-1-2|Ed.4.0 : 2014|as below|| |Low voltage PSU EMC|EN61204-3|High severity level|as below|| |ESD|EN61000-4-2|4|A|±8kV contact/±15kV air discharge| |Radiated|EN61000-4-3|3|A|| |EFT|EN61000-4-4|3|A|| |Surges|EN61000-4-5|Installation class 3|A|| |Conducted|EN61000-4-6|3|A|| |Magnetic feld|EN61000-4-8|4|A|| |Dips and interruptions|EN55024<br>(100VAC)|Dip >95% (0VAC), 8.3ms|A|| |||Dip 30% (70VAC), 416ms|B|| |||Dip >95% (0VAC), 4160ms|B|| ||EN55024<br>(240VAC)|Dip >95% (0VAC), 10ms|A|| |||Dip 30% (168VAC), 500ms|A|| |||Dip >95% (0VAC), 5000ms|B|| ||EN60601-1-2<br>(100VAC)|Dip 100% (0VAC), 10.0ms|A|| |||Dip 100% (0VAC), 20.0ms|B|| |||Dip 60% (40VAC), 100ms|B|| |||Dip 30% (70VAC), 500ms|B|| |||Dip 100% (0VAC), 5000ms|B|| ||EN60601-1-2<br>(240VAC)|Dip 100% (0VAC), 10.0ms|A|| |||Dip 100% (0VAC), 20.0ms|B|| |||Dip 60% (96VAC), 100ms|A|| |||Dip 30% (168VAC), 500ms|A|| |||Dip 100% (0VAC), 5000ms|B|| 3 **AC-DC power supplies** ## UCH600 series ## **Environmental** **==> picture [553 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Operating temperature|-20||+70|°C|See derating curve, safety approved to +50°C| |Storage temperature|-40||+80|°C|| |Cooling|||||Convection cooled| |Humidity|5||95|%RH|Non-condensing| |Operating altitude|||5000/4000|m|ITE/Medical| |Shock|±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (±0.5ms), half sine. Conforms to EN60068-2-27||||| |Vibration|Single axis 10-500Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6||||| ## **Safety approvals** |Certfcaton|Standard|Notes & conditons| |---|---|---| |CB report|IEC62368-1|Information technology| ||IEC60601-1 Ed 3.1 IncludingRisk Management|Medical| |UL|UL62368-1|Information technology| ||ANSI/AAMI ES60601-1 & CSA C22.2 No.60601-1:08|Medical| |TUV|EN62368-1|Information technology| ||EN60601-1|Medical| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| |||| ||Means of protecton|Notes & conditons| |Primaryto Secondary|2 x MOPP (Means of Patient Protection)|IEC60601-1 Ed 3.1| |Primaryto Earth|1 x MOPP (Means of Patient Protection)|| |Secondaryto Earth|1 x MOPP (Means of Patient Protection)|| 4 **AC-DC power supplies** ## UCH600 series ## **Mechanical details** **==> picture [464 x 387] intentionally omitted <==** **----- Start of picture text -----**<br> 193.2 (7.60) 5.0 (0.19)<br>40.0<br>(1.57)<br>20.0 (0.78)<br>M3 x 0.5 screw hole (4x)<br>203.2 (8.0) 40.0 (1.57)<br>+ + CN3<br>L4 + RT1 T3 C37++ JP2 -+ VO- VO-<br>VO-<br>Q5 w ++ 127.0(5.0) VO+<br>x + VO+ VO+<br>+<br>N N y + VO+<br>CN1L L C5 - 7 J1 1 + 1 3 1J3 3 CN2<br>CN1, 3 pin Remote On/Off CN202 CN2 other models 4 pin<br>barrier terminal DC Return barrier terminal block,<br>20.0 5VSB<br>block 9.5mm (0.79) 9.5mm pitch. M3.5.<br>pitch. M3. CN2 12V version 6 pin<br>barrier terminal block,<br>9.5mm pitch. M3.5<br>198.2 (7.8) CN3 - Fan connector<br>5.0<br>(0.197) Pin 1 Fan+<br>186.2 (7.33) M3 x 0.5 screw hole (4x) Pin 2 Fan-<br>15.2 (0.6) Mates with Molex 22-01-1022<br>CN202 - Signal connector<br>110.3 Pin 1 +5V standby<br>3.8 (4.34) Pin 2 DC return<br>(96.6)<br>Pin 3 Remote On/Off<br>Mates with JST Molex XHP-3<br>186.2 (7.33)<br>15.2 (0.6)<br>5.0 (0.197) 12.0 (0.47) 8.2 (0.32)<br>RF1<br>VO-<br>GSD<br>GSD VO+<br>R148<br>**----- End of picture text -----**<br> ## Notes: 1. All dimensions shown in mm (inches). Tolerance: 0.5 (±0.02). 2. Weight: 1100g (2.43lbs) approx. 4. To turn output off, connect Remote On/Off, Pin 3 to Return, Pin 2. Output is on if Remote On/Off, Pin 3 is floating or connected to 5V standby, Pin 1. 3. Maximum screw penetration 2.5mm (0.1”) ## **Application Notes** Efficiency Vs Load ## Figure 1 - UCH600PS12 ## Figure 2 - UCH600PS24 **==> picture [555 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> 100% 100%<br>90% 90%<br>80% 80% 110VAC input<br>110VAC input<br>70% 70% 230VAC input<br>230VAC input<br>60% 60%<br>50% 50%<br>10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100<br>Load (%) Load (%)<br>Efficiency Efficiency<br>**----- End of picture text -----**<br> 5 **AC-DC power supplies** ## UCH600 series ## **Applications Notes** Temperature derating curve Figure 3 **==> picture [265 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> 600<br>300<br>0<br>-20 0 +50 +70<br>Ambient Temperature (ºC)<br>Output Load (W)<br>**----- End of picture text -----**<br> ## **Thermal consideration** In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of direct air flow). See Mechanical Details for component locations. |Temperature measurements (at maximum ambient)|Temperature measurements (at maximum ambient)| |---|---| |Component|Max temperature °C| |**T3 coil**|110°C| |**L4 coil**|120°C| |**Q5 body**|120°C| |**C5**|105°C| |**C37**|105°C| ## **Service life** The estimated service life of the UCH600 is determined by the cooling arrangements and load conditions experienced in the end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitor with in the product when installed by the end application,. The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this temperature. Estimated service life vs component temperature Figure 4 **==> picture [312 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> 80000<br>70000<br>60000<br>50000<br>C37 C5<br>40000<br>30000<br>20000<br>10000<br>0<br>105 95 85 75 65 55 45<br>C5 + C37 Temperature (ºC)<br>Life�me (Hrs)<br>**----- End of picture text -----**<br> 18 November 2025 6
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →