TXO 200-124-J
AC/DC Open Frame Power Supply (PSU), ITE & Industrial, 1 Output, 200W @ 15CFM, 150 W
- Manufacturer: TRACO POWER
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (07-Nov-2024)
- Product Range: TXO 200 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 6.25A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Industrial
- Power Rating (Forced Cooling): 200W @ 15CFM
- Power Rating (Convection Cooling): 150W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 53.91 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC/DC Power Supply** **TXO 200 Series, 200 Watt** - **Industrial AC/DC power supplies for cost sensitive applications in 4" x 3" package** - **Universal input range 90 to 264 VAC** - **Operating temperature range: -20°C to +70°C** - **Protection class II prepared** - **Internal EN 55032 class B filter** - **Short circuit, overvoltage and overload protection** - **IEC/EN/UL 62368-1 safety approvals** - **Compliance to EN 61000-3-2** - **3-year product warranty** UL 62368-1 IEC 62368-1 The TXO 200 is a compact 200 Watt AC/DC open frame module with reinforced I/O isolation designed for a wide range of cost sensitive applications. A high efficiency of 90% allows the TXO 200 to deliver 150 Watt up to +50°C with convection cooling and 200 Watt up to +50°C with forced air cooling, while going up to +70°C with derating. It comes with an active power factor correction and EMC characteristics dedicated for applications in industrial/automation and test & measurement fields making these power supplies an ideal solution for various industrial and cost sensitive applications. ## **Models** |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**|**Output Current max.**<br>(Forced air cooling)|**Output Current max.**<br>(Natural convection)|**Efficiency**<br>**typ.**| |---|---|---|---|---|---| |**TXO 200-112-J**<br>**TXO 200-115-J**<br>**TXO 200-124-J**<br>**TXO 200-148-J**|200 W|12 VDC<br>15 VDC<br>24 VDC<br>48 VDC|16'670 mA<br>13'340 mA<br>8'340 mA<br>4'170 mA|11'670 mA<br>9'340 mA<br>6'250 mA<br>3'125 mA|89 %<br>89 %<br>90 %<br>90 %| ## **Options** |**TCI-AC1**|- Optional Cable:www.tracopower.com/overview/tci-ac1| |---|---| |**TXO 300-DC**|- Optional Cable:www.tracopower.com/overview/txo300-dc| |**on demand**|- Optional model with 36 VDC and 5'560 mA| |(backorder with MOQ|| |non stocking item)|- Optional model with 56 VDC and 3'580 mA| Note - Total output power must not exceed 150 W for convection cooling applications **Page 1 / 5** **November 28, 2024** **www.tracopower.com** **TXO 200 Series, 200 Watt** ## **Input Specifications** |Input Voltage|- AC Range|Operational Range: 90 - 264 VAC(Full Range)| |---|---|---| |||Rated Range: 100 - 240 VAC(Full Range)| ||- DC Range|Operational Range: 120 - 370 VDC(Designed for, no certification)| |||Polarity: irrelevant| |Input Frequency||Operational Range: 47 - 63 Hz| |||Certified: 50/60 Hz| |Power Consumption|- No load & Vin = 230 VAC|5'000 mW max.| ||- No load & Vin = 115 VAC|8'500 mW max.| |Input Current|- Full load & Vin = 230 VAC|1'100 mA max.| ||- Full load & Vin = 115 VAC|2'100 mA max.| |Input Inrush Current|- At 230 VAC|110 A max.| ||- At 115 VAC|65 A max.| |Power Factor|- At 230 VAC|0.9 min.(Active Power Factor Correction)| ||- At 115 VAC|0.9 min.(Active Power Factor Correction)| |Input Protection||T 4.0 A / 250 VAC(Internal Fuse in L & N)| |Recommended Input Fuse||4'000 mA(slow blow)| |||(The need of an external fuse has to be assessed| |||in the final application.)| |**Output Specifications**|**Output Specifications**||| |---|---|---|---| |Voltage Set Accuracy|||±3% max.| |Regulation|- Input Variation (Vmin - Vmax)||1% max.| ||- Load Variation(10 - 100%)||3% max.| |Ripple and Noise||12 VDC model:|200 mVp-p max.(w/ 22 µF ELCO || 0.1 µF| |(20 MHz Bandwidth)|||MLCC)| |||15 VDC model:|200 mVp-p max.(w/ 22 µF ELCO || 0.1 µF| ||||MLCC)| |||24 VDC model:|240 mVp-p max.(w/ 22 µF ELCO || 0.1 µF| ||||MLCC)| |||36 VDC model:|360 mVp-p max.(w/ 22 µF ELCO || 0.1 µF| ||||MLCC)| |||48 VDC model:|480 mVp-p max.(w/ 22 µF ELCO || 0.1 µF| ||||MLCC)| |||56 VDC model:|560 mVp-p max.(w/ 22 µF ELCO || 0.1 µF| ||||MLCC)| |Capacitive Load||12 VDC model:|20'000 µF max.| |||15 VDC model:|16'000 µF max.| |||24 VDC model:|8'000 µF max.| |||36 VDC model:|4'700 µF max.| |||48 VDC model:|2'600 µF max.| |||56 VDC model:|2'000µF max.| |Minimum Load|||Not required| |Temperature Coefficient|||±0.05 %/K max.| |Hold-up Time|- At 230 VAC||10 ms min.| ||- At 115 VAC||10 ms min.| |Start-up Time|- At 230 VAC||3'500 ms max.| ||- At 115 VAC||3'500 ms max.| |Start-upOvershoot Voltage|||10% max.| |Short Circuit Protection|||Continuous,Automatic recovery| |Output Current Limitation|||110 - 200% of Iout max.| |Overvoltage Protection|||105 - 150% of Vout nom.| |Transient Response|- Response Deviation||5% typ. / 8% max.(50% to 75% Load Step)| ||- Response Time||1'000 µs typ. / 2'000 µs max.(50% to 75%| ||||Load Step)| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 5** **November 28, 2024** **www.tracopower.com** **TXO 200 Series, 200 Watt** ## **Safety Specifications** |Standards|- IT / Multimedia Equipment||EN 62368-1| |---|---|---|---| ||||IEC 62368-1| ||||UL 62368-1| ||- Certification Documents||www.tracopower.com/overview/txo200| |Protection Class|||Class I & II(Prepared): Reinforced Insulation| |Pollution Degree|||PD 2| |Over Voltage Category|||OVC II| |**EMC Specifications**|||| |EMI (Emissions)|- Conducted Emissions||EN 55032 class A(internal filter)| ||||FCC 47 Part 15 class A(internal filter)| ||- Radiated Emissions||EN 55032 class A(internal filter)| ||||FCC 47 Part 15 class A(internal filter)| ||- Harmonic Current Emissions||EN 61000-3-2, class A| ||- Voltage Fluctuations & Flicker||EN 61000-3-3| |EMS (Immunity)|||EN 55035(Multimedia)| ||- Electrostatic Discharge|Air:|EN 61000-4-2, ±8 kV, perf. criteria A| |||Contact:|EN 61000-4-2, ±4 kV, perf. criteria A| ||- RF Electromagnetic Field||EN 61000-4-3, 3 V/m, perf. criteria A| ||- EFT (Burst) / Surge||EN 61000-4-4, ±1 kV, perf. criteria A| |||L to L:|EN 61000-4-5, ±1 kV, perf. criteria A| |||L to PE:|EN 61000-4-5, ±2 kV, perf. criteria A| ||- Conducted RF Disturbances||EN 61000-4-6, 3 Vrms, perf. criteria A| ||- PF Magnetic Field|Continuous:|EN 61000-4-8, 1 A/m, perf. criteria A| ||- Voltage Dips & Interruptions|230 VAC / 50 Hz:|EN 61000-4-11| ||||30%, 25 periods, perf. criteria A| ||||>95%, 0.5 periods, perf. criteria A| ||||>95%, 250 periods, perf. criteria B| |||115 VAC / 60 Hz:|EN 61000-4-11| ||||30%, 30 periods, perf. criteria B| ||||>95%,300periods, perf. criteria B| |**General Specifications**|**General Specifications**||| |---|---|---|---| |Relative Humidity|||95% max. (non condensing)| |Temperature Ranges|- Operating Temperature||–20°C to +70°C| ||- Approved Ambient Temp.||+70°C max.(for 50% load)| ||||+50°C max.(for 100% load)| ||||(for compliance to 62368-1)| ||- Storage Temperature||–40°C to +85°C| |Power Derating|- High Temperature||2.5 %/K above 50°C| ||- Low Input Voltage||Depending on model| |||See application note:|www.tracopower.com/overview/txo200| |Over Temperature|- Protection Mode||95°C min. / 105°C typ. / 115°C max.| |Protection Switch Off|||(Automatic recovery at 60°C typ.)| ||- Measurement Point||Internal IC temperature| |Cooling System|- Option 1||Forced air cooling(with external fan, 15 CFM)| ||- Option 2||Natural convection(20 LFM)| |Fan Power Source|- Characteristic||Constant fan speed(continuous)| ||- Output Voltage||12 VDC| ||- Output Current||300 mA max.| |Altitude DuringOperation|||2'000 m max.| |Regulator Topology|||LLC Converter| |SwitchingFrequency|||100 - 260 kHz (PFM)| |Insulation System|||Reinforced Insulation| |WorkingVoltage (rated)|||528 VAC| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 5** **November 28, 2024** **www.tracopower.com** **TXO 200 Series, 200 Watt** |Isolation Test Voltage|- Input to Output,60 s|4'242 VDC| |---|---|---| |Creepage|- Input to Output|5 mm min.| ||- Input to Case or PE|5 mm min.| ||- Output to Case or PE|0.85 mm min.| |Clearance|- Input to Output|3 mm min.| ||- Input to Case or PE|3 mm min.| ||- Output to Case or PE|0.85 mm min.| |Isolation Resistance|- Input to Output,500 VDC|100 MΩ min.| |Isolation Capacitance|- Input to Output,100 kHz,1 V|1'630pF typ. / 1'956pF max.| |Leakage Current|- Earth Leakage Current|300 µA max.| |(at 264 VAC / 60 Hz)|- Touch Current|500 µA max.| |Distance Through Isolation||0.16 mm| |Reliability|- Calculated MTBF|100'000 h(MIL-HDBK-217F, ground benign)| |WashingProcess||Not allowed| |Environment|- Vibration|2.4 g, 3 axis, random waveform, 30 min| ||- Mechanical Shock|20 g, 3 axis, half sine, 10 ms, total 6 shocks| |HousingType||Open Frame| |MountingType||Chassis Mount| |Connection Type||Pin Connector| |Weight||340 g| |Environmental Compliance|- REACH Declaration|www.tracopower.com/info/reach-declaration.pdf| |||REACH SVHC list compliant| |||REACH Annex XVII compliant| ||- RoHS Declaration|www.tracopower.com/info/rohs-declaration.pdf| |||Exemptions: 7a| |||(RoHS exemptions refer to the component| |||concentration only, not to the overall| |||concentration in the product (O5A rule).)| ||- SCIP Reference Number|e0d3eec3-a4ef-49f3-8a6d-f45a9ef39acc| ## **Supporting Documents** Overview Link (for additional Documents) www.tracopower.com/overview/txo200 All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 4 / 5** **November 28, 2024** **www.tracopower.com** **TXO 200 Series, 200 Watt** ## **Outline Dimensions** **==> picture [269 x 237] intentionally omitted <==** **----- Start of picture text -----**<br> CN2<br>4 8<br>1 5<br>CN3<br>1 2<br>CN1<br>3<br>1 4-Ø3.2 (Ø0.13)<br>20 (0.79) 93.1 (3.67)<br>101.6 (4)<br>)<br>2.67( 76.2 (3)<br>67.7<br>FAN (15 CFM min.)<br>38 )(1.5 max.<br>**----- End of picture text -----**<br> |Pin connectors<br>Input(CN1)<br>Output(CN2)|Pin connectors<br>Input(CN1)<br>Output(CN2)|Pin connectors<br>Input(CN1)<br>Output(CN2)|Pin connectors<br>Input(CN1)<br>Output(CN2)|Pin connectors<br>Input(CN1)<br>Output(CN2)| |---|---|---|---|---| |Pin<br>1|Function<br>AC (L)|Pin<br>1,2,5,6||Function<br>–Vout| |3|AC (N)|3,4,7,8||+Vout| |||||| |AUX(CN3)||||| |Pin<br>|Function|Pin<br>|Function|| |1|+Fan (12 V)|2|GND|| |Input:JST B3P-VH, 3.96 mm<br>mating connector:tbd||||| Output: Molex 39-28-1083 Mini-Fit Jr. Vertical Header, 4 pins, 4.20mm pitch mating connector: Molex 39-01-2080 or equivalent AUX: Molex 22-27-2021 Wafer, 2.54 mm pitch mating connector: Molex 22-01-2021 or equivalent Dimensions in mm (inch) Tolerances: ±0.5 (±0.02) Specifications can be changed without notice. © Copyright 2024 Traco Electronic AG Rev. November 28, 2024 **Page 5 / 5** www.tracopower.com
Updated at April 27, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →