TXN 200-148
AC/DC Enclosed Power Supply (PSU), ITE & Industrial, 1 Outputs, 200 W, 48 VDC, 4.2 A
- Manufacturer: TRACO POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (27-Jun-2024)
- Product Range: TXN 200 Series
- No. of Outputs: 1Outputs
- Output Power Max: 200W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 4.2A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Industrial
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 39.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC/DC Industrial Power Supply** **TXN 200 Series, 200 Watt** - **Compact metal case with screw terminal block** - **Universal input 90-264 VAC** - **I/O reinforced isolation 3000 VAC** - **Active power factor correction >0.9** - **Internal EN 55032 class B filter** - **High efficiency up to 89%** - **Operating temperature range –30°C to 70+°C** - **Short circuit, overvoltage and overload protection** - **IEC/EN/UL 62368-1 safety approvals** - **3-year product warranty** UL 62368-1 IEC 62368-1 The TXN 200 is a cost efficient, metal enclosed AC/DC power supplies series and is designed for industrial applications. With a low-profile metal case and screw terminal block connection, they are easy to install in any equipment. Active PFC (>0.9), internal EMC filter, high IO-isolation and wide temperature range qualify them for numerous industrial applications. All models within the TXN 200 series have universal input (90-264 VAC) and comply with the latest industrial standard IEC/EN/UL 62368-1, European EMC standards and the Low Voltage Directive (LVD). ## **Models** |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**(adjustable)|**Output Current**<br>**max.**|**Efficiency**<br>**typ.**| |---|---|---|---|---| |**TXN 200-112**<br>**TXN 200-115**<br>**TXN 200-124**<br>**TXN 200-148**|200 W|12 VDC(10.0 - 13.2 VDC)<br>15 VDC(13.5 - 15.5 VDC)<br>24 VDC(20.0 - 26.4 VDC)<br>48 VDC(41.0 - 56.0 VDC)|16'600 mA<br>13'300 mA<br>8'300 mA<br>4'200 mA|87 %<br>87 %<br>88 %<br>89 %| ## **Options** **on demand** (backorder with MOQ - Optional model with 36 VDC and 5'500 mA non stocking item) **Page 1 / 4** **October 8, 2024** **www.tracopower.com** **TXN 200 Series, 200 Watt** ## **Input Specifications** |Input Voltage|- AC Range|Operational Range: 90 - 264 VAC(Full Range)| |---|---|---| |||Rated Range: 100 - 240 VAC(Full Range)| ||- DC Range|Operational Range: 140 - 340 VDC(Designed for, no certification)| |||Polarity: +DC: L / –DC: N| |Input Frequency||Operational Range: 47 - 63 Hz| |||Certified: 50/60 Hz| |Power Consumption|- No load & Vin = 230 VAC|6 W max.| ||- No load & Vin = 115 VAC|6 W max.| |Input Current|- Full load & Vin = 230 VAC|1.3 A max.| ||- Full load & Vin = 115 VAC|3 A max.| |Input Inrush Current|- At 230 VAC|60 A max.| ||- At 115 VAC|30 A max.| |Power Factor|- At 230 VAC|0.9 min.(Active Power Factor Correction)| ||- At 115 VAC|0.95 min.(Active Power Factor Correction)| |Input Protection||T 6.3 A / 250 VAC(Internal Fuse in L)| |Recommended Input Fuse||(The need of an external fuse has to be assessed| |||in the final application.)| ## **Output Specifications** |Output Voltage Adjustment||12 VDC model: 10.0 - 13.2 VDC| |---|---|---| |||15 VDC model: 13.5 - 15.5 VDC| |||24 VDC model: 20.0 - 26.4 VDC| |||36 VDC model: 32.4 - 39.6 VDC| |||48 VDC model: 41.0 - 56.0 VDC| |||(By trim potentiometer)| |||Outputpower must not exceed ratedpower!| |Voltage Set Accuracy||±1% max.| |Regulation|- Input Variation (Vmin - Vmax)|0.5% max.| ||- Load Variation(10 - 90%)|1% max.| |Ripple and Noise||12 VDC model: 150 mVp-p max.(w/ 0.1 µF || 47 µF)| |(20 MHz Bandwidth)||15 VDC model: 150 mVp-p max.(w/ 0.1 µF || 47 µF)| |||24 VDC model: 150 mVp-p max.(w/ 0.1 µF || 47 µF)| |||36 VDC model: 240 mVp-p max.(w/ 0.1 µF || 47 µF)| |||48 VDC model: 240 mVp-pmax. (w/ 0.1µF||47µF)| |Minimum Load||Not required| |Temperature Coefficient||±0.03 %/K max.| |Hold-up Time|- At 230 VAC|8 ms min.| ||- At 115 VAC|8 ms min.| |Start-up Time|- At 230 VAC|1.5 s max.| ||- At 115 VAC|1.5 s max.| |Short Circuit Protection||Continuous,Automatic recovery| |Output Current Limitation||110 - 160% of Iout max.| |Overvoltage Protection||110 - 140% of Vout nom.| ## **Safety Specifications** |Standards|- IT / Multimedia Equipment|EN 62368-1| |---|---|---| |||IEC 62368-1| |||UL 62368-1| ||- Certification Documents|www.tracopower.com/overview/txn200| |Protection Class||Class I(Prepared): Connection to PE| |Pollution Degree||PD 2| |Over Voltage Category||OVC II| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 4** **October 8, 2024** **www.tracopower.com** **TXN 200 Series, 200 Watt** ## **EMC Specifications** EMI (Emissions) - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) - Harmonic Current Emissions EN 61000-3-2, class A - Voltage Fluctuations & Flicker EN 61000-3-3 EMS (Immunity) EN 55035 (Multimedia) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria B Contact: EN 61000-4-2, ±6 kV, perf. criteria B - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±1 kV, perf. criteria B L to PE: EN 61000-4-5, ±2 kV, perf. criteria B - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria B - PF Magnetic Field Continuous: EN 61000-4-8, 30 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria C >95%, 0.5 periods, perf. criteria B >95%, 250 periods, perf. criteria C EMC / Environmental - Certification Documents www.tracopower.com/overview/txn200 |**General Specifications**|**General Specifications**||| |---|---|---|---| |Relative Humidity|||95% max. (non condensing)| |Temperature Ranges|- Operating Temperature||–30°C to +70°C| ||- Storage Temperature||–40°C to +80°C| |Power Derating|- High Temperature||2 %/K above 50°C| ||- Low Input Voltage||1 %/V below 110 VAC| |||See application note:|www.tracopower.com/overview/txn200| |Over Temperature|- Protection Mode||Automatic recovery| |Protection Switch Off|- Measurement Point||Internal IC temperature| |CoolingSystem|||Natural convection(20 LFM)| |Remote Control|- Voltage Controlled Remote||Off: 4 to 10 VDC| ||(passive = on)||Refers to '+Remote' and '-Remote' Pin| ||||On: < 0.6 VDC or open circuit or short circuit| ||- Remote Pin Input Current||0.5 to 2.5 mA| |Altitude DuringOperation|||5'000 m max.| |Regulator Topology|||Forward Converter| |SwitchingFrequency|||75 kHz typ. (PWM)| |Insulation System|||Reinforced Insulation| |Isolation Test Voltage|- Input to Output, 60 s||3'000 VAC| ||- Input to Case or PE, 60 s||1'500 VAC| ||- Output to Case or PE, 60 s||500 VAC| |Isolation Resistance|- Input to Output,500 VDC||10 MΩ min.| |Leakage Current|- Earth Leakage Current||3.5 mA max.| |(at 240 VAC / 60 Hz)|||| |Reliability|- Calculated MTBF||225'800 h(MIL-HDBK-217F, ground benign)| |WashingProcess|||Not allowed| |Environment|- Vibration||2 g, 3 axis, 60 min, 10-500 Hz, 10 min/cycle| ||- Mechanical Shock||20 g, 3 axis, 3 shocks| |HousingMaterial|||Aluminum(Chassis)| |HousingType|||Metal Case| |MountingType|||Chassis Mount| |Connection Type|||Screw Terminal| |Weight|||800 g| |Status Indicator|||Indicated by green LED| |Sense Function|||0.2% max. of Vout nom.| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 4** **October 8, 2024** **www.tracopower.com** **TXN 200 Series, 200 Watt** Environmental Compliance - REACH Declaration - RoHS Declaration - SCIP Reference Number www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) 10d38219-6664-4b19-bdba-f0841289695e ## **Supporting Documents** Overview Link (for additional Documents) www.tracopower.com/overview/txn200 ## **Outline Dimensions** **==> picture [264 x 235] intentionally omitted <==** **----- Start of picture text -----**<br> 15 2-M4 (Side) 15 AUX (CON3)<br>7.5 7.5 2 1<br>4 3<br>Vout adjustment Status indicator Vout adjustment<br>Status<br>indicator<br>9<br>8<br>7<br>6<br>5<br>4<br>3<br>2<br>1<br>32.5±0.3 150±0.4 4-M4 (Bottom) 30±0.5<br>2-M4 (Side)<br>14 15<br>215±1.0<br>6.9 12.8<br>50±0.2 115±0.5<br>32.5±0.3<br>6.9 12.8<br>**----- End of picture text -----**<br> **==> picture [144 x 187] intentionally omitted <==** **----- Start of picture text -----**<br> Pin connectors<br>Input/Output AUX<br>Pin Function Pin Function<br>1 AC (L) 1 +Remote<br>2 AC (N) 2 –Remote<br>3 PE 3 +Sense<br>4 4 –Sense<br>5 –Vout<br>6<br>7<br>8 +Vout<br>9<br>**----- End of picture text -----**<br> Input/Output: Wire dimension range: 22 - 12 AWG 0.324 - 3.31 mm² AUX: mating connector: YL028-106-004, 2mm pitch Dimensions in mm Terminal screw tightening torque: Max. 1.2 Nm Mounting screw tightening torque: Max. 0.8 Nm Mounting screw penetration depth: Max. 4 mm © Copyright 2024 Traco Electronic AG Specifications can be changed without notice. Rev. October 8, 2024 www.tracopower.com **Page 4 / 4**
Updated at June 7, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →