TXM100-105
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 100 W, 5 VDC, 20 A
- Manufacturer: TRACO POWER
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:100W; Output Voltage - Output 1:5V; Output Current - Output 1:20A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Output
- SVHC: No SVHC (16-Jul-2019)
- Product Range: TXM100 Series
- No. of Outputs: 1Outputs
- Output Power Max: 100W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 20A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 55.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TXM 100 Series, 100 Watt** ## **AC/DC Power Supply** - **Very compact metal cased power supplies** - **High operating temperature up to 60°C** - **Screw terminal block** - **No internal fan** - **Universal AC input, full range** - **Active power factor correction >0.93** - **Withstand 300 VAC surge input for 5 s** - **Adjustable output voltage** - **3-year product warranty** UL 62368-1 IEC 62368-1 The TXM 100 series of 100 Watt is a family of enclosed AC/DC power supplies designed for cost critical applications. With a low profile metal case and screw terminal block connections, they are easy to install in any equipment. There are five models of single output voltages from 5 VDC to 48 VDC. These power supplies have universal input and comply with European EMC standards and the Low Voltage Directive (LVD). ## **Models** |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**(adjustable)|**Output Current**<br>**max.**|**Efficiency**<br>**typ.**| |---|---|---|---|---| |**TXM 100-105**<br>**TXM 100-112**<br>**TXM 100-115**<br>**TXM 100-124**<br>**TXM 100-148**|100 W|5 VDC(3.3 - 5.5 VDC)<br>12 VDC(10.0 - 15.0 VDC)<br>15 VDC(13.5 - 17.0 VDC)<br>24 VDC(21.0 - 27.0 VDC)<br>48 VDC(43.2 - 52.8 VDC)|20'000 mA<br>8'500 mA<br>7'000 mA<br>4'200 mA<br>2'200 mA|84 %<br>87 %<br>87 %<br>88 %<br>88 %| ||102 W|||| ||105 W|||| ||101 W|||| ||106 W|||| **Page 1 / 4** **March 16, 2023** **www.tracopower.com** **TXM 100 Series, 100 Watt** ## **Input Specifications** |Input Voltage|- AC Range|Operational Range: 85 - 264 VAC(Full Range)| |---|---|---| |||Rated Range: 100 - 240 VAC(Full Range)| ||- DC Range|Operational Range: 120 - 375 VDC(Designed for, no certification)| |||Polarity: irrelevant| |||(Surge voltage(5 s max.): 300 VAC max.)| |Input Frequency||Operational Range: 47 - 63 Hz| |||Certified: 50/60 Hz| |Input Current|- Full Load & Vin = 115 VAC|1'500 mA max.| |Power Consumption|- No load & Vin = 230 VAC|5'100 mW max.| ||- No load & Vin = 115 VAC|5'000 mW max.| |Input Inrush Current|- At 230 VAC|50 A max.| ||- At 115 VAC|30 A max.| |Power Factor|- At 230 VAC|0.98 min.(Active Power Factor Correction)| ||- At 115 VAC|0.93 min.(Active Power Factor Correction)| |Recommended Input Fuse||(The need of an external fuse has to be assessed| |||in the final application.)| ## **Output Specifications** |Output Voltage Adjustment||5 VDC model: 3.3 - 5.5 VDC| |---|---|---| |||12 VDC model: 10.0 - 15.0 VDC| |||15 VDC model: 13.5 - 17.0 VDC| |||24 VDC model: 21.0 - 27.0 VDC| |||48 VDC model: 43.2 - 52.8 VDC| |||(By trim potentiometer)| |||Outputpower must not exceed ratedpower!| |Voltage Set Accuracy||±1% max.(24 & 48 VDC models)| |||±2 % max.(5,12 & 15 VDC models)| |Regulation|- Input Variation (Vmin - Vmax)|0.5% max.| ||- Load Variation (0 - 100%)|1% max.(24 & 48 VDC models)| |||2% max.(5,12 & 15 VDC models)| |Ripple and Noise||150 mVp-p max.(w/ 0.1 µF || 10 µF)| |(20 MHz Bandwidth)||| |Minimum Load||Not required| |Temperature Coefficient||±0.03 %/K max.| |Hold-upTime|- At 230 VAC|12 ms min.| |Start-up Time|- At 230 VAC|2'000 ms max.| ||- At 115 VAC|4'000 ms max.| |Start-upOvershoot Voltage||5% max.| |Short Circuit Protection||Continuous,Automatic recovery| |Output Current Limitation||110 - 150% of Iout max.| |Transient Response|- Response Deviation|5% max.(75% to 100% Load Step)| ||- Response Time|400 µs typ.(75% to 100% Load Step)| ## **Safety Specifications** |Safety Standards|- IT / Multimedia Equipment|EN 60950-1| |---|---|---| |||EN 62368-1| |||IEC 60950-1| |||IEC 62368-1| |||UL 60950-1| |||UL 62368-1| ||- Certification Documents|www.tracopower.com/overview/txm100| |Protection Class||Class I(Prepared): Connection to PE| |Pollution Degree||PD 2| |Over Voltage Category||OVC II| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 4** **March 16, 2023** **www.tracopower.com** **TXM 100 Series, 100 Watt** ## **EMC Specifications** EMI Emissions - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) - Harmonic Current Emissions EN 61000-3-2, class D - Voltage Fluctuations & Flicker EN 61000-3-3 EMS Immunity EN 55024 (IT Equipment) EN 55035 (Multimedia) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria B Contact: EN 61000-4-2, ±4 kV, perf. criteria B - RF Electromagnetic Field EN 61000-4-3, 3 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±1 kV, perf. criteria B L to L: EN 61000-4-5, ±1 kV, perf. criteria B L to PE: EN 61000-4-5, ±2 kV, perf. criteria B - Conducted RF Disturbances EN 61000-4-6, 3 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 1 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria C >95%, 0.5 periods, perf. criteria B >95%, 250 periods, perf. criteria C ## **General Specifications** |Relative Humidity||90% max. (non condensing)| |---|---|---| |Temperature Ranges|- Operating Temperature|–20°C to +60°C| ||- Storage Temperature|–30°C to +85°C| |Power Derating|- High Temperature|2.5 %/K above 40°C| ||- Low Input Voltage|1 %/V below 100 VAC| |||See application note: www.tracopower.com/overview/txm100| |CoolingSystem||Natural convection(20 LFM)| |Altitude DuringOperation||5'000 m max.| |SwitchingFrequency||100 kHz typ. (PWM)| |Insulation System||Reinforced Insulation| |WorkingVoltage (rated)||360 VAC| |Isolation Test Voltage|- Input to Output, 60 s|3'000 VDC| ||- Input to Case or PE, 60 s|1'500 VAC| ||- Output to Case or PE, 60 s|500 VAC| |Creepage|- Input to Output|6.2 mm min.| |Clearance|- Input to Output|6.2 mm min.| |Isolation Resistance|- Input to Output,500 VDC|100 MΩ min.| |Leakage Current|- Earth Leakage Current|3500 µA max.| ||- Touch Current|250 µA max.| |Reliability|- Calculated MTBF|200'000 h(MIL-HDBK-217F, ground benign)| |HousingMaterial||Aluminum| |HousingType||Metal Case| |MountingType||Chassis Mount| |Connection Type||Screw Terminal| |Weight||455 g| |Environmental Compliance|- REACH Declaration|www.tracopower.com/info/reach-declaration.pdf| |||REACH SVHC list compliant| |||REACH Annex XVII compliant| ||- RoHS Declaration|www.tracopower.com/info/rohs-declaration.pdf| |||Exemptions: 7a, 7c-I| |||(RoHS exemptions refer to the component| |||concentration only, not to the overall| |||concentration in the product (O5A rule).| |||The SCIP number isprovided on request.)| All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 4** **March 16, 2023** **www.tracopower.com** **TXM 100 Series, 100 Watt** ## **Supporting Documents** Overview Link (for additional Documents) www.tracopower.com/overview/txm100 ## **Outline Dimensions** **==> picture [326 x 267] intentionally omitted <==** **----- Start of picture text -----**<br> 129 (5.08)<br>121.5 (4.78) 4.5(0.18)<br>78 (3.07) 23.38<br>Ø3.5 (0.92)<br>(0.14)<br>1 3<br>LED<br>ADJ<br>6x M3<br>9<br>5 5x Ø3.5<br>(0.14)<br>4<br>3<br>10 2<br>1<br>2<br>4<br>Dimensions in mm (inch)<br>119.5 (4.7) 6.5 Outside dimension tolerance: ±1.0 (±0.04)<br>86 (3.386) 20 (0.26) Customer plate SMPS Cover<br>(0.79)<br>11 2x R 1.75 Assemble Screw<br>3x M3<br>14 Ø3.513<br>16<br>12<br>15<br>L max.<br>)<br>1.3( (3.37) 99 (3.9)<br>33 (1.94) 85.5<br>8.02 (0.32)<br>) 9.53 (0.38) 49.2<br>(1.22<br>31 (0.67)<br>17 7 (0.28)<br>12 (0.47) 18 (0.71) (1.14) (1.5)<br>(0.79) 38<br>29<br>11 (0.43) 20<br>**----- End of picture text -----**<br> **==> picture [83 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> Pin-Out<br>Pin Function<br>1 AC (L)<br>2 AC (N)<br>3 PE<br>4 – Vout<br>5 + Vout<br>**----- End of picture text -----**<br> |||||| |---|---|---|---|---| |Screw Defnition||||| |Installation Method|Position|No.<br>Screw Size|L max.|Torque max.| |Bottom Installation|1-4|M3|5 (0.20|)<br>7.0 kgfcm| ||9-10|M3|3 (0.12)|6.5 kgfcm| |Side Installation|11-13|M3|5 (0.20|)<br>7.0 kgfcm| ||14-16|M3|3 (0.12)|6.5 kgfcm| © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. Rev. March 16, 2023 **Page 4 / 4** www.tracopower.com
Updated at June 7, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →