Image not available
Illustrative purposes only
TR2/TCP500-R
SURFACE MOUNT FUSES FA 250V 500MA
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON / PARTNER STOCK
- Product type: SMD Fuses
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 7500 |
| Price | 0.786 € |
| Current stock | 1000+ |
| Lead time | 30 days |
## **TCP[™] Series** ## **TCP1.25A,Telecom Circuit Protector** ## **Description** - The first and most reliable surface mount telecom circuit protector designed to protect against power cross faults and comply with all surge requirements. **==> picture [32 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> RoHS<br>2002/95/EC<br>**----- End of picture text -----**<br> - Allows compliance with telecom regulatory standards including Bellcore GR 1089, UL 1950/60950, and FCC part 68. Application circuit testing is recommended. - Eliminates the need for a current limiting resistor. - Protects against overcurrent conditions found in telecom Subscriber Line Interface Cards (SLICs), xDSL Modem Applications, Set-Top Boxes, and Consumer Premises Equipment (CPE). ## **Dimensions**[mm] ⁄(inches) - TCP1.25A tested and confirmed compatible with STMicroelectronics Trisil™Transient Surge Arrestor (list of part numbers below) ## **STMicroelectronics Trisil™ P/N’s** SMP100LC-XXX SMP100MC-XXX |**ELECTRICAL CHARACTERISTICS**|**ELECTRICAL CHARACTERISTICS**| |---|---| |**% of Amp Rating**|**Opening Time**| |**of Amp Rating**<br>100%|**Opening Time**<br>4 Hours Minimum| |250%|1 Second Minimum| |250%<br>250%|1 Second Minimum<br>4-10 Seconds Typical| |250%*|120 Seconds Maximum| |300%|10 Seconds Maximum| - If the device does not open at 250% within 120 seconds, increase current to 300% of amp rating. Device must open in 10 seconds max. ## **Environmental Data** - Life Test: MIL-STD-202, Method 108A, Test Condition D - Load Humidity: MIL-STD-202, Method 103B - Moisture Resistance: MIL-STD-202, Method 106E - Thermal Shock: MIL-STD-202, Method 107D, air-to-air - Case Resistance: EIA/IS-722 - Resistance to Dissolution of Metallization: ANSI J-STD-002, Test D - Mechanical Shock: MIL-STD-202, Method 213B, Test Condition A - High Frequency Vibration: MIL-STD-202, Method 204D, Test Condition D - • Resistance to Solvents: MIL-STD-202, Method 215A **==> picture [176 x 78] intentionally omitted <==** **----- Start of picture text -----**<br> Land Pattern 5.2 3.7<br>k (0.204) — >\e (0.145) — >|<br>4.0<br>(0.157)<br>|] oe<br>12.6<br>}« — (0.496) oo ><br>**----- End of picture text -----**<br> ## **Agency Information** - UL Recognition Card: JDYX2/E19180 - CSA Component Certification Record and Class No.: 053787C000, 1422 30 ## **Ordering** - Specify packaging, product and option code (i.e., TR2/TCP1.25-R) ## **Soldering Method** - Wave Immersion: 260°C, 10 sec max. • Infrared: 260°C, 30 sec max. **==> picture [522 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> PC LIGHTNING SURGE SPECIFICATIONS<br>Surge Specification Surge Repetitions Waveform Current (A) Voltage (V) Performance<br>(µSec.) Requirement<br>Rs FCC 47 Part 68 GO Longitudinal Type A 2 10x160 100 per fuse 1500 Fuse cannot open<br>es FCC 47 Part 68 GO Metallic Type B 2 10x560 100 800 Fuse cannot open<br>Rs Bellcore GR-1089-CORE nn First Level Lightning (OOO 50 10x1000 100 1000 Fuse cannot open<br>Rs Bellcore GR-1089-CORE (OO First Level Lightning 50 2x10 500 2500 Fuse cannot open<br>es Surge out GO 1 10x160 160 N/A Fuse cannot open<br>en Surge out GO 1 10x560 GO 115 N/A Fuse cannot open<br>ELECTRICAL AND POWER CROSS SPECIFICATIONS<br>Product Voltage Interrupting DC Cold Typical Maximum Typical Alpha Code<br>Code Rating Rating* Resistance** (ohms) Melting Total Voltage Marking<br>AC 250VAC 600VAC min. typ. max. I [2] t† Clearing Drop‡ 1st Code 2nd Code<br>TCP1.25A 250 V 50 A 60 A 0.070 0.090 0.110 22.2 A [2] s 100 A [2] s 150mV J R***<br>**----- End of picture text -----**<br> - AC Interrupting Rating (Measured at designated voltage, 100% power factor) - ** DC Cold Resistance (Measured at 10% of rated current) - *** On RoHS Compliant Version (-R option) - Typical Melting I[2] t (Measured with a battery bank at 60V DC, 10x-rated current, time constant of calibrated circuit less than 50 microseconds) - Typical Voltage Drop (Measured at rated current after temperature stabilizes) **TCP[™] Series TCP1.25A,Telecom Circuit Protector** ## **Special Investigation** The TCP1.25A is designed to provide overcurrent protection for telecom SLIC, xDSL modem, and set-top box applications regardless of the overvoltage device selected. To provide an easier specification experience, Cooper Bussmann and STMicroelectronics have joined together to provide a special test report confirming the coordination between the TCP1.25A and SMP100MC-270 devices. ## **TEST CIRCUITS** **==> picture [405 x 182] intentionally omitted <==** **----- Start of picture text -----**<br> Fuse TCP 1.25A<br>Tip L Tip S<br>Fuse TCP 1.25A<br>L1 T1 SMP100MC-270*<br>SMP100MC-270* Gnd Gnd<br>L2 T2 SMP100MC-270*<br>Fuse TCP 1.25A<br>Ring L Ring S<br>**----- End of picture text -----**<br> **==> picture [47 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Test Circuit 1<br>**----- End of picture text -----**<br> Test Circuit 2 *** Note:** or other STMicroelectronics Trisil™part number listed in table on page 1 ## **TEST PROGRAM** |**Test**<br>**Standard**<br>**Results**|**Test**<br>**Standard**<br>**Results**|**Test**<br>**Standard**<br>**Results**| |---|---|---| |**Lightning Surge Tests**||| |10/1000µs+and–1kV 100A(25 pulses ofeachpolarity)|Bellcore GR-1089|Passed| |2/10µs+and–2.5 and 5kV500A(10 pulses ofeachpolarity)|Bellcore GR-1089|Passed| |10/560µs+and–800V 100A(1pulse ofeachpolarity)|FCCPart68|Passed| |10/160µs+and–1.5kV 200A(1pulse ofeachpolarity)|FCCPart68|Passed| |10/700µs+and–1.5kV37.5A(5 pulses ofeachpolarity)|K20|Passed| |**Electrical and Power Cross Tests**||| |600V3A 1.1s (first level)|Bellcore GR-1089|Passed| |277V 25A(secondlevel)|Bellcore GR-1089|Passed| |600V60A5s(secondlevel)|Bellcore GR-1089|Passed| |600V 40A 1.5s|UL60950|Passed| |600V 2.2A30min|UL60950|Passed| |600V 1A0.2s (Acriteria)|K20|Passed| |230V 1.44A/0.77A/0.38A 15min(Acriteria)|K20|Passed| |230V 23A 15min (A criteria)|K20|Passed| For additional information on STMicroelectronic’s Trisil™Product line, please see www.st.com/protection ## **TCP[™] Series** ## **TCP500MA & TCP2A,Telecom Circuit Protector** ## **Description** - Designed to protect Consumer Premises Equipment from harmful overcurrents. **==> picture [32 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> RoHS<br>2002/95/EC<br>**----- End of picture text -----**<br> - Allows compliance with telecom regulatory standards including UL 1950/60950, and FCC part 68. Application circuit testing is recommended. - Eliminates the need for a current limiting resistor. |harmful overcurrents.<br>• Allows compliance with telecom regulatory standards<br>including UL 1950/60950, and FCC part 68. Application<br>circuit testing is recommended.<br>• Eliminates the need for a current limiting resistor.|harmful overcurrents.<br>• Allows compliance with telecom regulatory standards<br>including UL 1950/60950, and FCC part 68. Application<br>circuit testing is recommended.<br>• Eliminates the need for a current limiting resistor.| |---|---| |**ELECTRICAL CHARACTERISTICS**|| |**% of Amp Rating**|**Opening Time**| |**of Amp Rating**<br>100%|**Opening Time**<br>4 Hours Minimum| |250%|1 Second Minimum| |250%|4-10 Seconds Typical| |250%*|10 Seconds Typical<br>120 Seconds Maximum| |300%|10 Seconds Maximum| ## **Dimensions**[mm] ⁄(inches) - If the device does not open at 250% within 120 seconds, increase current to 300% of amp rating. Device must open in 10 seconds max. ## **Agency Information** - UL Recognition Card: JDYX2/E19180 - CSA Component Certification Record and Class No.: 053787C000, 1422 30 ## **Environmental Data** - Life Test: MIL-STD-202, Method 108A, Test Condition D - Load Humidity: MIL-STD-202, Method 103B - Moisture Resistance: MIL-STD-202, Method 106E - Thermal Shock: MIL-STD-202, Method 107D, air-to-air - Case Resistance: EIA/IS-722 - Resistance to Dissolution of Metallization: ANSI J-STD-002, Test D - Mechanical Shock: MIL-STD-202, Method 213B, Test Condition A - High Frequency Vibration: MIL-STD-202, Method 204D, Test Condition D - • Resistance to Solvents: MIL-STD-202, Method 215A **==> picture [176 x 78] intentionally omitted <==** **----- Start of picture text -----**<br> Land Pattern 5.2 3.7<br>k (0.204) =e (0.145) = >|<br>4.0<br>(0.157)<br>| | | | +<br>12.6<br>}« — (0.496) —_—,_- —_——<br>**----- End of picture text -----**<br> ## **Ordering** - Specify packaging, product and option code (i.e., TR2/TCP500-R) ## **Soldering Method** - Wave Immersion: 260°C, 10 sec max. • Infrared: 260°C, 30 sec max. |**LIGHTNING SURGE SPECIFICATIONS**<br>||**LIGHTNING SURGE SPECIFICATIONS**<br>||**LIGHTNING SURGE SPECIFICATIONS**<br>||**LIGHTNING SURGE SPECIFICATIONS**<br>||**LIGHTNING SURGE SPECIFICATIONS**<br>||**LIGHTNING SURGE SPECIFICATIONS**<br>||**LIGHTNING SURGE SPECIFICATIONS**<br>|| |---|---|---|---|---|---|---| |**Surge Specification**|**Surge**|**Repetitions**|**Waveform**<br>**(µSec.)**|**Current (A)**<br>~~a~~|**Voltage (V)**<br>~~a~~<br>~~a~~|**Performance**<br>**Requirement**<br>~~a~~| |**TCP 500mA tested**<br>~~a~~<br>~~a~~<br>~~RsGe~~<br>~~QQ~~<br>~~OO~~||||||| |FCC 47 Part 68<br>~~Rs~~<br>~~Re~~|Longitudinal Type B<br>~~Ge~~<br>~~QQ~~|2<br>~~QQ~~<br>~~QQ~~|5x320<br>~~QQ~~<br>|37.5<br>~~OO~~<br>|N/A<br>~~OO~~<br>|Fuse cannot open<br>| |FCC 47 Part 68<br>~~Rs~~<br>~~Re~~<br>~~Re~~<br>~~CO~~|Metallic Type A<br>~~Ge~~<br>~~QQ~~<br>~~Qn~~<br>|2<br>~~QQ~~<br>~~QQ(QO~~<br>~~Qf~~<br>|10x560<br>~~QQ~~<br>~~(QO~~<br>~~Qf~~<br>|100<br>~~OO~~<br>~~(QO~~<br>~~QQ~~<br>|800<br>~~OO~~<br>~~(QO~~<br>~~QQ~~<br>|Fuse must open safely<br>~~(QO~~<br>| |Surge out<br>~~Re~~<br>~~Re~~<br>~~CO~~|~~QQ~~<br>~~Qn~~<br>|25<br>~~QQ(QO~~<br>~~Qf~~<br>|10x160<br>~~(QO~~<br>~~Qf~~<br>|65<br>~~(QO~~<br>~~QQ~~<br>|N/A<br>~~(QO~~<br>~~QQ~~<br>|Fuse cannot open<br>~~(QO~~<br>| |**TCP2A tested**<br>~~(QO~~<br>~~ReQn~~<br>~~QfQQ~~<br>~~COReQDQO(GG~~||||||| |FCC 47 Part 68<br><br>~~CORe~~<br>~~Rs~~|Longitudinal Type A<br>~~Qn~~<br>~~QD~~<br>~~Q~~|2<br>~~Qf~~<br>~~QO~~<br>~~Q~~|10x160<br>~~Qf ~~<br>~~(GG~~<br>~~Q~~|100 per fuse<br> ~~QQ~~<br>~~(GG~~<br>~~Q~~~~**Q**~~<br>~~O~~|1500<br>~~QQ~~<br>~~(GG~~<br>~~**Q**~~<br>~~O~~|Fuse cannot open<br>~~(GG~~<br>~~**Q**~~| |FCC 47 Part 68<br>~~Re~~<br>~~Rs~~<br>~~Re~~|Metallic Type B<br>~~QD~~<br>~~Q~~<br>|2<br>~~QO ~~<br>~~Q~~<br>|10x560<br> ~~(GG~~<br>~~Q~~<br>|100<br>~~(GG~~<br>~~Q~~~~**Q**~~<br>~~O~~<br>~~GO~~<br>|800<br>~~(GG~~<br>~~**Q**~~<br>~~O~~<br>~~GO~~<br>|Fuse cannot open<br>~~(GG~~<br>~~**Q**~~<br>| |Bellcore GR-1089-CORE<br>~~Rs~~<br>~~QQ~~<br>~~Re~~<br>~~Rs~~|First Level Lightning<br>~~Q~~<br>~~QQ~~<br>~~**Q**D~~|50<br>~~Q~~<br>~~QQ~~<br>~~QR~~|10x1000<br>~~Q~~<br>~~QQ~~<br>~~(QQ~~|100<br>~~Q~~~~**Q**~~<br>~~O~~<br>~~QQ~~<br>~~GO~~<br>~~(QQ~~|1000<br>~~**Q**~~<br>~~O~~<br>~~QQ~~<br>~~GO~~<br>~~(QQ~~|Fuse cannot open<br>~~**Q**~~<br>~~QQ~~<br>~~(QQ~~| |Bellcore GR-1089-CORE<br>~~QQ~~<br>~~Re~~<br>~~Rs~~|First Level Lightning<br>~~QQ~~<br>~~**Q**D~~|50<br>~~QQ~~<br>~~QR~~|2x10<br>~~QQ~~<br>~~(QQ~~|500<br>~~QQ~~<br>~~GO~~<br>~~(QQ~~<br>~~O~~|2500<br>~~QQ~~<br>~~GO~~<br>~~(QQ~~<br>~~O~~|Fuse cannot open<br>~~QQ~~<br>~~(QQ~~| |Surge out<br>~~Re~~<br>~~Rs~~|~~**Q**D~~|1<br>~~QR~~<br>~~QQ~~|10x160<br>~~(QQ~~<br>~~QQ~~|160<br>~~GO~~<br>~~(QQ~~<br>~~**Q**~~<br>~~O~~<br>~~QO~~|N/A<br>~~GO~~<br>~~(QQ~~<br>~~**Q**~~<br>~~O~~<br>~~QO~~|Fuse cannot open<br>~~(QQ~~<br>~~**Q**~~| |Surge out<br><br>~~Rs~~<br>~~Qe~~|~~**Q**D~~<br>~~Qe~~|1<br>~~QR ~~<br>~~Qe~~<br>~~QQ~~|10x560<br> ~~(QQ~~<br>~~Qe~~<br>~~QQ~~|115<br>~~(QQ~~<br>~~O~~<br>~~Qe~~<br>~~QO~~|N/A<br>~~(QQ~~<br>~~O~~<br>~~Qe~~<br>~~QO~~|Fuse cannot open<br>~~(QQ~~<br>~~Qe~~| - AC Interrupting Rating (Measured at designated voltage, 100% power factor) - ** DC Cold Resistance (Measured at 10% of rated current) - *** On RoHS Compliant Version (-R option) - Typical Melting I[2] t (Measured with a battery bank at 60V DC, 10x-rated current, time constant of calibrated circuit less than 50 microseconds) - Typical Voltage Drop (Measured at rated current after temperature stabilizes) ## **TCP[™] Series TCP500MA & TCP2A,Telecom Circuit Protector** ## **TIME CURRENT CURVE** **==> picture [356 x 438] intentionally omitted <==** ## **PACKAGING CODE** **Packaging Code Description TR2** 2,500 pieces of fuses on 24mm tape-and-reel on 13 inch (330mm) reel per EIA Standard 481, 8mm pitch **OPTION CODE Option Code Description -R** RoHS Compliant Version (Sn plating w/ Ni barrier) > Visit us on the web at: **North America Europe Asia Pacific** > **www.cooperbussmann.com** Cooper Electronic Technologies Cooper Bussmann Cooper Electronic Technologies Cooper Electronic Technologies Cooper Electronic Technologies 1225 Broken Sound Parkway NW P.O. Box 14460 Cooper (UK) Limited Avda. Santa Eulalia, 290 1 Jalan Kilang Timor > Datasheet: OC-2609 1/07 Suite F St. Louis, MO 63178-4460 Burton-on-the-Wolds 08223 #06-01 Pacific Tech Centre Boca Raton, FL 33487-3533 Tel: 1-636-394-2877 Leicestershire • LE12 5TH UK Terrassa, (Barcelona), Spain Singapore 159303 > © Cooper Electronic Tel: 1-561-998-4100 Fax: 1-800-544-2570 Tel: +44 (0) 1509 882 737 Tel: +34 937 362 812 Tel: +65 278 6151 > Technologies 2007 Fax: 1-561-241-6640 Fax: +44 (0) 1509 882 786 +34 937 362 813 Fax: +65 270 4160 Toll Free: 1-888-414-2645 Fax: +34 937 362 719
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →