TPP40-105A-J
AC/DC Open Frame Power Supply (PSU), Medical, 1 Output, 40 W, 85V AC to 264V AC
- Manufacturer: TRACO POWER
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):40W; Power Rating (Forced Cooling):-; Input Voltage VAC:85V AC to 264V AC; Power Supply Output Type:Adjustable, Fixed; Output Voltage
- SVHC: No SVHC (16-Jul-2019)
- Product Range: TPP 40A Series
- No. of Outputs: 1 Output
- Output Power Max: 40W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 8A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 40W
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 34.61 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TPP 40A Series, 40 Watt** ## **AC/DC Medical Power Supply** - **Open frame power supply with pin connector** - **Certification according to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP** - **Low leakage current <75 µA rated for BF applications** - **Risk management process according to ISO 14971 incl. risk management file** - **Acceptance criteria for electronic assemblies acc. to IPC-A-610 Level 3** - **EMC compliance to IEC 60601-1-2 ed. 4** **• Protection class l and ll prepared** adyZ eme **• Operating up to 5000 m altitude** ES 60601-1 IEC 60601-1 **• Ready to meet ErP directive, <0.15 W** The TPP 40A Series of 40 Watt AC/DC power supplies feature a reinforced **no load power consumption** double I/O isolation system according to latest medical safety standards **• 5 year product warranty** IEC/EN/ES 60601-1 3rd edition for 2 x MOPP up to 5000 m MSL. The earth leakage current is below 75 µA what makes the units suitable for BF (body floating) applications. The excellent efficiency of up to 92% allows a high power density for the standard 2.44” x 3.0” packaging format. The full load operating temperature range is –40°C to +70°C while it goes up to 85°C with 50% load derating. The EMC characteristic complies to IEC 60601-1-2 ed.4 and is dedicated for applications in industrial and domestic fields. High reliability is provided by use of industrial quality grade components and an excellent thermal management. It makes the products an ideal solution for medical devices and for demanding safety and space critical applications. **Models Order Code Output Power Output Voltage Output Current Efficiency max. nom.** (adjustable) **max. typ. TPP 40-105A-J** 5 VDC (4.5 - 5.5 VDC) 8'000 mA 90 % **TPP 40-112A-J** 12 VDC (10.8 - 13.2 VDC) 3'340 mA 92 % 40 W **TPP 40-124A-J** 24 VDC (21.6 - 26.4 VDC) 1'670 mA 92 % **TPP 40-148A-J** 48 VDC (43.2 - 52.8 VDC) 840 mA 93 % ~~—~~ Note - Other output models are available on request. **Page 1 / 4** **March 18, 2019** **www.tracopower.com** **TPP 40A Series, 40 Watt** ## **Input Specifications** |Input Voltage|- AC Range|85 - 264 VAC(Full Range)| |---|---|---| ||- DC Range|120 - 370 VDC(designed for, no certification)| |Input Frequency||47 – 63 Hz| |Input Current|- Full Load & Vin = 230 VAC|500 mA max.| ||- Full Load & Vin = 115 VAC|1000 mA max.| |Power Consumption|- at no Load|150 mW max. (Readyto meet ErP directive)| |Input Inrush Current|- at 230 VAC|60 A max.| |Input Protection||T 3.15 A / 250 VAC(Internal Fuse in L & N)| ## **Output Specifications** |Output Voltage Adjustment||±10% (bytrimpotentiometer)| |---|---|---| |Voltage Set Accuracy||±1% max.| |Regulation|- Input Variation (Vmin - Vmax)|0.2% max.| ||- Load Variation (0 - 100%)|0.5% max.| |||0.7% max.(5 VDC model)| |Ripple and Noise||5 VDC model: 75 mVp-p typ.(with 10 µF X7R)| |(20 MHz Bandwidth)||12 VDC model: 75 mVp-p typ.(with 10 µF X7R)| |||24 VDC model: 75 mVp-p typ.(with 1 µF X7R)| |||48 VDC model: 150 mVp-ptyp. (with 0.1µF X7R)| |Capacitive Load||5 VDC model: 16'000 µF max.| |||12 VDC model: 2'785 µF max.| |||24 VDC model: 700 µF max.| |||48 VDC model: 175µF max.| |Minimum Load||not required| |Temperature Coefficient||±0.02 %/K| |Hold-upTime|- at 115 VAC|25 ms min.| |Start-upTime|- at 230 VAC|1'000 ms max.| |Output Current Limitation||115 - 180% of Iout max.| |Short Circuit Protection||Continuous,automatic recovery| |Overvoltage Protection||125 - 140% of Vout nom.| |Transient Response|- Response Deviation|3% max.(50% to 75% Load Step)| ||- Response Time|600 µs typ.(50% to 75% Load Step)| ## **Safety Specifications** |Safety Standards|- Medical Equipment|EN 60601-1| |---|---|---| |||IEC 60601-1| |||ANSI/AAMI ES 60601-1| |||2 x MOPP(Means Of Patient Protection)| ||- Certification Documents|www.tracopower.com/overview/tpp40a| |Protection Class||Class I Prepared: Connection to PE| |||Class II Prepared: Reinforced Insulation| |Pollution Degree||PD 2: Office or LaboratoryEnvironments| |Over Voltage Category||OVC II| All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. **Page 2 / 4** **March 18, 2019** **www.tracopower.com** **TPP 40A Series, 40 Watt** ## **EMC Specifications** EMC Emission - Conducted Emissions - Radiated Emissions - Harmonic Current Emissions - Voltage Fluctuations & Flicker EMC Immunity - Electrostatic Discharge - RF Electromagnetic Field - EFT (Burst) - Surge - Conducted RF Disturbances - PF Magnetic Field - Voltage Dips & Interruptions EN 60601-1-2 edition 4 (Medical Devices) EN 55011 class B (internal filter) EN 55032 class B (internal filter) FCC Part 15, class B FCC Part 18, class B EN 55011 class B (internal filter) EN 55032 class B (internal filter) FCC Part 15, class B FCC Part 18, class B EN 61000-3-2, class A EN 61000-3-3 EN 60601-1-2 edition 4 (Medical Devices) Air: EN 61000-4-2, ±15 kV, perf. criteria A Contact: EN 61000-4-2, ±8 kV, perf. criteria A EN 61000-4-3, 20 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±1 kV, perf. criteria A L to PE: EN 61000-4-5, ±2 kV, perf. criteria A EN 61000-4-6, 20 Vrms, perf. criteria A EN 61000-4-8, 30 A/m, perf. criteria A 230 VAC / 50 Hz: EN 61000-4-11 30%, perf. criteria A, 25 periods >95%, perf. criteria A, 0.5 periods >95%, perf. criteria A, 1 period >95%, perf. criteria B, 250 periods 115 VAC / 60 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A >95%, 1 period, perf. criteria A >95%, 250 periods, perf. criteria B ## **General Specifications** |Relative Humidity||95% max. (non condensing)| |---|---|---| |Temperature Ranges|- Operating Temperature|-40°C to +85°C| ||- Storage Temperature|-40°C to +85°C| |Power Derating|- High Temperature|see application note| |||www.tracopower.com/overview/tpp40a| |Coolingsystem||Natural convection(no internal fan,20 LFM)| |Altitude duringOperation||5000 m max.| |SwitchingFrequency||50 - 140 kHz (PWM)| |Insulation System||Reinfoced Insulation| |WorkingVoltage(rated)||258 VAC| |Isolation Test Voltage|- Input to Output, 60 s|5'657 VDC| ||- Input to Case or PE, 60 s|3'535 VDC| ||- Output to Case or PE, 60 s|3'535 VDC| |Isolation Resistance|- Input to Output,500 VDC|100 MOhm min.| |Leakage Current|- Touch Current|75 µA max.| |(at 264 VAC)||| |Creepage||8 mm min.| |Clearance||8 mm min.| |Reliability|- Calculated MTBF|3'000'000 h (acc. to MIL-HDBK-217F)| |Environment|- Vibration|IEC 60068-2-6| |||3 axis, sine sweep, 10 - 55 Hz, 1 g, 1 oct/min| ||- Mechanical Shock|IEC 60068-2-27| |||3 axis, 10 g half sine, 11 ms shock| |||20g (3 directions each 3 times)| All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. **Page 3 / 4** **March 18, 2019** **www.tracopower.com** **TPP 40A Series, 40 Watt** www.tracopower.com/overview/tpp40apower.com/overview/tpp40aower.com/overview/tpp40app40a40a Connection Type Weight Environmental Compliance - Reach - RoHS JST 114 g www.tracopower.com/info/reach-declaration.pdf www.tracopower.com/info/rohs-declaration.pdf ## ~~Le~~ **Supporting Documents** Overview Link (for additional Documents) www.tracopower.com/overview/tpp40apower.com/overview/tpp40aower.com/overview/tpp40app40a40a ## **Outline Dimensions** ~~Ce~~ ## Screw Terminal |Input(CON1)|Output(CON2)| |---|---| |Pin<br>Function<br>1<br>Line<br>3<br>Neutral|Pin*<br>Function<br>1,2<br>–Vout<br>3,4<br>+Vout| *Terminal rated for 7 A max. (at higher current connection has to be split) CON1: JST series mates with JST crimp terminal: BVH-21T-P1.1 and terminal housing: VHR-3N CON2: JST series mates with JST crimp terminal: BVH-21T-P1.1 and terminal housing: VHR-4N Each one of the 4 screw holes can be used as a PE connection for CLASS I application. Dimensions in inch, ( ) = mm Outside dimension tolerance: ±0.02 inch (±0.5 mm) Hole spacing tolerance: ±0.01 inch (±0.25 mm) © Copyright 2019 Traco Electronic AG Specifications can be changed without notice. Rev. March 18, 2019 www.tracopower.com **Page 4 / 4**
Updated at April 27, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →