TPP30-112A-J
AC/DC Open Frame Power Supply (PSU), Medical, 1 Output, 30 W, 85V AC to 264V AC
- Manufacturer: TRACO POWER
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):30W; Power Rating (Forced Cooling):-; Input Voltage VAC:85V AC to 264V AC; Power Supply Output Type:Adjustable, Fixed; Output Volt
- SVHC: No SVHC (16-Jul-2019)
- Product Range: TPP 30A-J Series
- No. of Outputs: 1 Output
- Output Power Max: 30W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 2.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 30W
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 29.31 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TPP 30A-J Series, 30 Watt** ## **AC/DC Medical Power Supply** - **High power density power supply (open frame)** - **Certification according to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP** - **Low leakage current <75 µA rated for BF applications** - **EMC compliance to IEC 60601-1-2 4th edition** - **Risk management process according to ISO 14971 incl. risk management file** - **Acceptance criteria for electronic assemblies acc. to IPC-A-610 Level 3** - **Protection class l and ll** - **Operating up to 5000 m altitude** - **Ready to meet ErP directive, no load power consumption <60 mW** - **5 year product warranty** ES 60601-1 IEC 60601-1 UL 62368-1 IEC 62368-1 The TPP 30A-J AC/DC power supplies feature a reinforced double I/O isolation system according to medical safety standards IEC/EN/ES 60601-1 3rd edition for 2 x MOPP approved for an operating altitude of 5000 m. The earth leakage current is below 75 µA what makes the units suitable for BF (body floating) applications. The excellent efficiency of up to 92% offers a high power density in the packaging format 1.36” x 3.34”. The full load operating temperature range covers –40°C to +60°C while it goes up to 85°C with 50% load derating. The units operate in compliance to the medical EMC emission and immunity levels according to latest standard IEC 60601-1-2 4th edition. |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**(adjustable)|**Output Current**<br>**max.**|**Efficiency**<br>**typ.**| |---|---|---|---|---| |**TPP 30-103A-J**<br>**TPP 30-105A-J**<br>**TPP 30-109A-J**<br>**TPP 30-112A-J**<br>**TPP 30-115A-J**<br>**TPP 30-124A-J**<br>**TPP 30-136A-J**<br>**TPP 30-148A-J**|20 W|3.3 VDC(2.97 - 3.63 VDC)<br>5 VDC(4.5 - 5.5 VDC)<br>9 VDC(8.1 - 9.9 VDC)<br>12 VDC(10.8 - 13.2 VDC)<br>15 VDC(13.5 - 16.5 VDC)<br>24 VDC(21.6 - 26.4 VDC)<br>36 VDC(32.4 - 39.6 VDC)<br>48 VDC(43.2 - 52.8 VDC)|6'000 mA<br>6'000 mA<br>3'340 mA<br>2'500 mA<br>2'000 mA<br>1'250 mA<br>840 mA<br>630 mA|84 %<br>87 %<br>88 %<br>91 %<br>91 %<br>90 %<br>90 %<br>92 %| ||30 W|||| **Page 1 / 4** **March 18, 2019** **www.tracopower.com** **TPP 30A-J Series, 30 Watt** ## **Input Specifications** |Input Voltage|- AC Range|85 - 264 VAC(Full Range)| |---|---|---| ||- DC Range|120 - 370 VDC(designed for, no certification)| |Input Frequency||47 – 63 Hz| |Input Current|- Full Load & Vin = 230 VAC|400 mA max.| ||- Full Load & Vin = 115 VAC|800 mA max.| |Power Consumption|- at no Load|60 mW max. (Readyto meet ErP directive)| |Input Inrush Current|- at 230 VAC|40 A max.| |Input Protection||T 1.6 A / 250 VAC(Internal Fuse in L & N)| ## **Output Specifications** |Output Voltage Adjustment||±10% (bytrimpotentiometer)| |---|---|---| |Voltage Set Accuracy||±1% max.| |Regulation|- Input Variation (Vmin - Vmax)|0.2% max.| ||- Load Variation (0 - 100%)|0.5% max.| |||0.7% max.(3.3 and 5 VDC model)| |Ripple and Noise||3.3 VDC model: 50 mVp-p typ.(with 10 µF X7R)| |(20 MHz Bandwidth)||5 VDC model: 50 mVp-p typ.(with 10 µF X7R)| |||9 VDC model: 50 mVp-p typ.(with 10 µF X7R)| |||12 VDC model: 50 mVp-p typ.(with 1 µF X7R)| |||15 VDC model: 50 mVp-p typ.(with 1 µF X7R)| |||24 VDC model: 50 mVp-p typ.(with 1 µF X7R)| |||36 VDC model: 50 mVp-p typ.(with 1 µF X7R)| |||48 VDC model: 50 mVp-ptyp. (with 0.1µF X7R)| |Capacitive Load||3.3 VDC model: 10'000 µF max.| |||5 VDC model: 12'000 µF max.| |||9 VDC model: 3'720 µF max.| |||12 VDC model: 2'085 µF max.| |||15 VDC model: 1'350 µF max.| |||24 VDC model: 520 µF max.| |||36 VDC model: 235 µF max.| |||48 VDC model: 130µF max.| |Minimum Load||not required| |Temperature Coefficient||±0.02 %/K| |Hold-upTime|- at 115 VAC|16 ms min.| |Start-upTime|- at 230 VAC|1'500 ms max.| |Output Current Limitation||110 - 170% of Iout max.| |Short Circuit Protection||Continuous,automatic recovery| |Overvoltage Protection||125 - 140% of Vout nom.| |Transient Response|- Response Deviation|3% max.(50% to 75% Load Step)| ||- Response Time|500 µs typ.(50% to 75% Load Step)| ## **Safety Specifications** |Safety Standards|- IT / Multimedia Equipment|EN 62368-1| |---|---|---| |||IEC 62368-1| |||UL 62368-1| ||- Medical Equipment|EN 60601-1| |||IEC 60601-1| |||ANSI/AAMI ES 60601-1| |||2 x MOPP(Means Of Patient Protection)| ||- Certification Documents|www.tracopower.com/overview/tpp30a-j| |Protection Class||Class I Prepared: Connection to PE| |||Class II Prepared: Reinforced Insulation| |Pollution Degree||PD 2: Office or LaboratoryEnvironments| |Over Voltage Category||OVC II| All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. **Page 2 / 4** **March 18, 2019** **www.tracopower.com** **TPP 30A-J Series, 30 Watt** ## **EMC Specifications** EMC Emission EN 60601-1-2 edition 4 (Medical Devices) - Conducted Emissions EN 55011 class B (internal filter) EN 55014-1 EN 55032 class B (internal filter) FCC Part 15, class B FCC Part 18, class B - Radiated Emissions EN 55011 class B (internal filter) EN 55014-1 EN 55032 class B (internal filter) FCC Part 15, class B FCC Part 18, class B - Harmonic Current Emissions EN 61000-3-2, class A - Voltage Fluctuations & Flicker EN 61000-3-3 EMC Immunity EN 55024 (IT Equipment) EN 60601-1-2 edition 4 (Medical Devices) EN 55014-2 (Household Appliances Tools) - Electrostatic Discharge Air: EN 61000-4-2, ±15 kV, perf. criteria A Contact: EN 61000-4-2, ±8 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 20 V/m, perf. criteria A - EFT (Burst) EN 61000-4-4, ±2 kV, perf. criteria A - Surge L to L: EN 61000-4-5, ±1 kV, perf. criteria A L to PE: EN 61000-4-5, ±2 kV, perf. criteria A - Conducted RF Disturbances EN 61000-4-6, 20 Vrms, perf. criteria A - PF Magnetic Field EN 61000-4-8, 30 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, perf. criteria A, 25 periods 60%, perf. criteria A, 1 periods >95%, perf. criteria A, 1 period >95%, perf. criteria A, 250 periods 115 VAC / 60 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria A 60%, 1 periods, perf. criteria A >95%, 1 period, perf. criteria A >95%, 250 periods, perf. criteria A ## **General Specifications** |Relative Humidity||95% max. (non condensing)| |---|---|---| |Temperature Ranges|- Operating Temperature|-40°C to +85°C| ||- Storage Temperature|-40°C to +85°C| |Power Derating|- High Temperature|see application note| |||www.tracopower.com/overview/tpp30a-j| ||- Low Input Voltage|4 %/V below 90V| |Coolingsystem||Natural convection(no internal fan,20 LFM)| |Altitude duringOperation||5000 m max.| |SwitchingFrequency||30 - 60 kHz (PWM)| |Insulation System||Reinfoced Insulation| |WorkingVoltage(rated)||272 VAC| |Isolation Test Voltage|- Input to Output, 60 s|5'657 VDC| ||- Input to Case or PE, 60 s|2'121 VDC| ||- Output to Case or PE, 60 s|2'121 VDC| |Isolation Resistance|- Input to Output,500 VDC|100 MOhm min.| |Leakage Current|- Touch Current|75 µA max.| |(at 264 VAC)||| |Creepage||8 mm min.| |Clearance||8 mm min.| All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. **Page 3 / 4** **March 18, 2019** **www.tracopower.com** **TPP 30A-J Series, 30 Watt** Reliability - Calculated MTBF Environment - Vibration - Mechanical Shock Connection Type Weight Environmental Compliance - Reach - RoHS 3'300'000 h (acc. to MIL-HDBK-217F) IEC 60068-2-6 IEC 60068-2-27 JST 60.5 g www.tracopower.com/info/reach-declaration.pdf www.tracopower.com/info/rohs-declaration.pdf ## **Supporting Documents** Overview Link (for additional Documents) www.tracopower.com/overview/tpp30a-j ## **Outline Dimensions** **==> picture [315 x 270] intentionally omitted <==** **----- Start of picture text -----**<br> Each one of the 4 screw holes can be used<br>as a PE connection for CLASS I application.<br>3.2 (0.13)<br>2<br>1<br>1<br>3<br>3.45 (0.13)<br>V adjust<br>78.1 (3.08) 3.35 (0.13)<br>84.8 (3.34)<br>(0.77)<br>19.6<br>(0.11)<br>2.8<br>(1.10)<br>Output (1.36)<br>Input<br>27.9<br>34.6<br>**----- End of picture text -----**<br> |Pin connectors|Pin connectors|Pin connectors|Pin connectors| |---|---|---|---| |Input||Output|| |Pin|Function|Pin|Function| |1|Line|1|+Vout| |3|Neutral|2|–Vout| Input: JST series mates with JST crimp terminal: SVH-21T-P1.1 and terminal housing: VHR-3N Output: JST series mates with JST crimp terminal: SVH-21T-P1.1 and terminal housing: VHR-2N Print thickness: 1.6 mm (0.06 inch) Dimension in mm, () = inch Tolerances: x.x ±0.50 (±0.02) x.xx ±0.25 (±0.01) © Copyright 2019 Traco Electronic AG Specifications can be changed without notice. Rev. March 18, 2019 **Page 4 / 4** www.tracopower.com
Updated at April 27, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →