TPI 65-105A-JP
AC/DC Open Frame Power Supply (PSU), 120 to 370VDC, ITE, 1 Output, 50 W, 85V AC to 264V AC
- Manufacturer: TRACO POWER
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (16-Jul-2019)
- Product Range: TPI 65A-J Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 10A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 50W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 31.32 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TPI 65A-J Series, 65 Watt** ## **AC/DC Power Supply** - **65 Watt open frame power supplies in a 3" x 2" package** - **Compact and cost efficient design** - **Peak power function up to 140%** - **I/O reinforced isolation 3000 VAC** - **Operating temperature range –40°C to +85°C** - **No load input power <0.3W (acc. ErP directive)** - **High efficiency up to 93%** - **Internal EN 55032 class B filter** - **Protection class II prepared** - **3-year product warranty** UL 62368-1 IEC 62368-1 The TPI 65A-J is a 65 Watt AC/DC open frame power supplies series with a 3000 VAC reinforced isolation system. Our TPI line specifically focuses on providing cost efficient industrial power supplies in compact designs. This series offers a peak power function which enables the unit to deliver up to 140% of the rated power for up to 10 seconds. Excellent efficiency of up to 93% allows a compact design and an operating temperature range (natural convection) of –40°C to +70°C without derating, while going up to +85°C with either load derating or forced cooling. They are designed to meet the ErP directive (< 0.3 W no load power consumption) and come with an EMC characteristics dedicated for applications in industrial/automation and test & measurement fields. High reliability is provided by use of industrial high-quality grade components and an excellent thermal management. It makes the TPI 65A-J an ideal solution for any demanding industrial devices or space critical applications. |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**(adjustable)|**Output Current**<br>**max.**|**Output Current**<br>**peak**|**Efficiency**<br>**typ.**| |---|---|---|---|---|---| |**TPI 65-105A-JP**<br>**TPI 65-112A-JP**<br>**TPI 65-115A-JP**<br>**TPI 65-124A-JP**<br>**TPI 65-136A-JP**<br>**TPI 65-148A-JP**<br>**TPI 65-153A-JP**|50 W|5 VDC(4.0 - 5.5 VDC)<br>12 VDC(9.6 - 13.2 VDC)<br>15 VDC(12.0 - 16.5 VDC)<br>24 VDC(19.2 - 26.4 VDC)<br>36 VDC(28.8 - 39.6 VDC)<br>48 VDC(38.4 - 52.8 VDC)<br>53 VDC(42.4 - 58.3 VDC)|10'000 mA<br>5'420 mA<br>4'340 mA<br>2'710 mA<br>1'810 mA<br>1'360 mA<br>1'240 mA|13'000 mA<br>7'500 mA<br>6'000 mA<br>3'750 mA<br>2'500 mA<br>1'875 mA<br>1'698 mA|90 %<br>93 %<br>94 %<br>94 %<br>93 %<br>93 %<br>93 %| ||65 W||||| **Page 1 / 5** **April 16, 2026** **www.tracopower.com** **TPI 65A-J Series, 65 Watt** ## **Input Specifications** |Input Voltage|- AC Range|Operational Range:|85 - 264 VAC(Full Range)| |---|---|---|---| |||Rated Range:|100 - 240 VAC(Full Range)| ||- DC Range|Operational Range:|120 - 370 VDC(Designed for, no certification)| |||Polarity:|+DC: L / –DC: N| |Input Frequency||Operational Range:|47 - 440 Hz| |||Certified:|50/60 Hz| |Power Consumption|- No load & Vin = 230 VAC||180 mW max.(Ready to meet ErP directive)| ||- No load & Vin = 115 VAC||180 mW max.| |Input Current|- Full load & Vin = 230 VAC||900 mA max.| ||- Full load & Vin = 115 VAC||1'600 mA max.| |Input Inrush Current|- At 230 VAC||75 A max.| ||- At 115 VAC||40 A max.| |Input Protection|||T 3.15 A / 250 VAC(Internal Fuse in L)| |Recommended Input Fuse|||(The need of an external fuse has to be assessed| ||||in the final application.)| |**Output Specifications**|||| |Output Voltage Adjustment|||–20% to +10%(By trim potentiometer)| ||||Output power must not exceed rated power!| |Voltage Set Accuracy|||±1% max.| |Regulation|- Input Variation (Vmin - Vmax)||0.2% max.| ||- Load Variation (0 - 100%)||0.7% max.(5 VDC model)| ||||0.5% max.(other output models)| |Boost Power|||Output Current peak: See model table| ||||Peak power time: 5 s max.| ||||Peak power duty cycle: 20% max.| ||||Average operation power: 70% of full load| ||||(detailed description see application note)| |Ripple and Noise||5 VDC model:|75 mVp-p typ.(w/ 10 µF, 25 V, MLCC)| |(20 MHz Bandwidth)||12 VDC model:|75 mVp-p typ.(w/ 10 µF, 25 V, MLCC)| |||15 VDC model:|75 mVp-p typ.(w/ 10 µF, 25 V, MLCC)| |||24 VDC model:|75 mVp-p typ.(w/ 1 µF,50 V, MLCC)| |||36 VDC model:|75 mVp-p typ.(w/ 1 µF,50 V, MLCC)| |||48 VDC model:|150 mVp-p typ.(w/ 0.1 µF,100 V, MLCC)| |||53 VDC model:|150 mVp-ptyp. (w/ 0.1µF,100 V,MLCC)| |Capacitive Load||5 VDC model:|20'000 µF max.| |||12 VDC model:|4'520 µF max.| |||15 VDC model:|2'900 µF max.| |||24 VDC model:|1'130 µF max.| |||36 VDC model:|520 µF max.| |||48 VDC model:|285 µF max.| |||53 VDC model:|235µF max.| |Minimum Load|||Not required| |Temperature Coefficient|||±0.02 %/K max.| |Hold-up Time|- At 230 VAC||90 ms min.| ||- At 115 VAC||15 ms min.| |Start-up Time|- At 230 VAC||800 ms max.| ||- At 115 VAC||950 ms max.| |Short Circuit Protection|||Continuous,Automatic recovery| |Output Current Limitation|||165% typ. of Iout max.| |Overvoltage Protection|||125 - 140% of Vout nom.| |Transient Response|- Response Deviation||3% max.(50% to 75% Load Step at 2.5 A/µs)| ||- Response Time||600 µs typ.(50% to 75% Load Step at 2.5 A/µs)| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 5** **April 16, 2026** **www.tracopower.com** **TPI 65A-J Series, 65 Watt** ## **Safety Specifications** |Standards|- IT / Multimedia Equipment||EN 62368-1| |---|---|---|---| ||||IEC 62368-1| ||||UL 62368-1| ||- Certification Documents||www.tracopower.com/tpi65a-j-safety-cert| |Protection Class|||Class I & II(Prepared): Reinforced Insulation| |||See application note:|www.tracopower.com/info/protection-class.pdf| |EnergySource|- Output,acc. to 62368-1||ES1| |Power Source|- Output,acc. to 62368-1||PS3| |Pollution Degree|||PD 2| |Over Voltage Category|||OVC I| ||||OVC II| |**EMC Specifications**|||| |EMI (Emissions)|- Conducted Emissions||EN 55011 class A(internal filter)| ||||EN 55011 class B(internal filter)| ||||EN 55032 class A(internal filter)| ||||EN 55032 class B(internal filter)| ||||FCC 47 Part 15 class A(internal filter)| ||||FCC 47 Part 15 class B(internal filter)| ||- Radiated Emissions||EN 55011 class A(internal filter)| ||||EN 55011 class B(internal filter)| ||||EN 55032 class A(internal filter)| ||||EN 55032 class B(internal filter)| ||||FCC 47 Part 15 class A(internal filter)| ||||FCC 47 Part 15 class B(internal filter)| ||- Harmonic Current Emissions||EN 61000-3-2, class A| ||- Voltage Fluctuations & Flicker||EN 61000-3-3| |EMS (Immunity)|||EN 55024(IT Equipment)| ||||EN 55035(Multimedia)| ||- Electrostatic Discharge|Air:|EN 61000-4-2, ±15 kV, perf. criteria A| |||Contact:|EN 61000-4-2, ±6 kV, perf. criteria A| ||- RF Electromagnetic Field||EN 61000-4-3, 20 V/m, perf. criteria A| ||- EFT (Burst) / Surge||EN 61000-4-4, ±4 kV, perf. criteria A| |||L to L:|EN 61000-4-5, ±2 kV, perf. criteria A| ||- Conducted RF Disturbances||EN 61000-4-6, 20 Vrms, perf. criteria A| ||- PF Magnetic Field|Continuous:|EN 61000-4-8, 100 A/m, perf. criteria A| ||- Voltage Dips & Interruptions|230 VAC / 50 Hz:|EN 61000-4-11| |||115 VAC / 60 Hz:|EN 61000-4-11| |**General Specifications**|||| |Relative Humidity|||95% max. (non condensing)| |Temperature Ranges|- Operating Temperature||–40°C to +85°C| ||- Storage Temperature||–40°C to +85°C| |Power Derating|- High Temperature||Depending on model| ||- Low Input Voltage||4.0 %/V below 90 VAC| |||See application note:|www.tracopower.com/tpi65a-j-cc| |CoolingSystem|||Natural convection(20 LFM)| |Altitude DuringOperation|||5'000 m max.| |Regulator Topology|||Flyback Converter| |Switching Frequency|||60 kHz typ.(PWM QR) (5 VDC models)| ||||120 kHz typ.(PWM QR) (other models)| |Insulation System|||Reinforced Insulation| |WorkingVoltage (rated)|||273 VAC| |Isolation Test Voltage|- Input to Output,60 s||3'000 VAC| |Creepage|- Input to Output||8 mm min.| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 5** **April 16, 2026** **www.tracopower.com** **TPI 65A-J Series, 65 Watt** |Clearance|- Input to Output|8 mm min.| |---|---|---| |Isolation Resistance|- Input to Output,500 VDC|100 MΩ min.| |Leakage Current|- Earth Leakage Current|75 µA max.| |(at 264 VAC)||| |Distance Through Isolation||0.4 mm| |Reliability|- Calculated MTBF|1'490'000 h(MIL-HDBK-217F, ground benign)| |Environment|- Vibration|IEC 60068-2-6| ||- Mechanical Shock|IEC 60068-2-27| |HousingType||Open Frame| |MountingType||Chassis Mount| |Connection Type||Pin Connector| |Weight||117 g| |Environmental Compliance|- REACH Declaration|www.tracopower.com/info/reach-declaration.pdf| |||REACH SVHC list compliant| |||REACH Annex XVII compliant| ||- RoHS Declaration|www.tracopower.com/info/rohs-declaration.pdf| |||Exemptions: 7(a), 7(c)-I| |||(RoHS exemptions refer to the component| |||concentration only, not to the overall| |||concentration in the product (O5A rule).)| ||- SCIP Reference Number|54f38b10-a6c9-46f7-9475-640404133b0c| |**Additional Information**||| |SupportingDocuments||www.tracopower.com/overview/tpi65a-j| |FrequentlyAsked Questions||www.tracopower.com/glossary-faq| |Glossary||www.tracopower.com/info/glossary.pdf| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 4 / 5** **April 16, 2026** **www.tracopower.com** **TPI 65A-J Series, 65 Watt** ## **Outline Dimensions** **==> picture [267 x 332] intentionally omitted <==** **----- Start of picture text -----**<br> Voltage Adj.<br>1<br>3<br>4<br>1<br>Ø3.2 (Ø0.13)<br>69.80 (2.748)<br>76.2 (3.00)<br>Dimensions in mm (inch)<br>Tolerances: x.x ±0.5 (x.xx ±0.02)<br>Tolerances: x.xx±0.25 (x.xxx ±0.01)<br>Screw lock torque: Max. 0.49 Nm (5 kgfcm)<br>1.6 (0.06) 24.0 max. (0.94 max.)<br>2.5 max. (0.10 max.)<br>CON1 (1.750) (2.00)<br>44.45 50.8<br>CON2<br>**----- End of picture text -----**<br> |Pin connectors|Pin connectors|Pin connectors|Pin connectors| |---|---|---|---| |Input(CON1)||Output(CON2)|| |Pin|Function|Pin|Function| |1|Line|1,2*|–Vout| |3|Neutral|3,4*|+Vout| *Terminal rated for 10 A max per pin. (at higher current connection has to be split) Input: JST series mates with JST crimp terminal: SVH-21T-P1.1 and terminal housing: VHR-3N Output: JST series mates with JST crimp terminal: SVH-21T-P1.1 and terminal housing: VHR-4N Specifications can be changed without notice. © Copyright 2025 Traco Electronic AG Rev. April 16, 2026 **Page 5 / 5** www.tracopower.com
Updated at April 27, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →