TPI 100-136A-J
AC/DC Open Frame Power Supply (PSU), ITE, 1 Output, 100 W, 85V AC to 264V AC, Adjustable, Fixed
- Manufacturer: TRACO POWER
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (16-Jul-2019)
- Product Range: TPI 100A Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 2.78A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 36VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 100W
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 65.64 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TPI 100A Series, 100 Watt** ## **AC/DC Industrial Power Supply** - **Highest power density 100 W open frame power supply in 2” x 3” package** - **I/O reinforced isolation 3000 VAC** - **Ready to meet ErP directive, < 0.3 W no load power consumption** - **Highest efficiency 91% - 92% across 10% - 100% load range** - **Active power factor correction > 95** - **Protection class II prepared** - **Operating up to 5000 m altitude** - **Adjustable output voltage** - **3-year product warranty** UL 62368-1 IEC 62368-1 The TPI 100A Series of 100 Watt AC/DC power supplies features a 3000 VAC I/O reinforced isolation. Excellent efficiency of up to 92% allows a high power density for the standard 2.0” x 3.0” packaging format. The full load operating temperature range is –40°C to +50°C while it goes up to 80°C with load derating. The power supplies are designed to meet the ErP directive (< 0.3 W no load power consumption). They come with an active power factor correction and the EMC characteristic is dedicated for applications in industrial and domestic fields. High reliability is provided by use of industrial quality grade components and an excellent thermal management. It makes the products an ideal solution for any demanding industrial devices and space critical applications. ## **Models** |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**(adjustable)|**Output Current**<br>**max.**|**Efficiency**<br>**typ.**| |---|---|---|---|---| |**TPI 100-112A-J**<br>**TPI 100-115A-J**<br>**TPI 100-124A-J**<br>**TPI 100-128A-J**<br>**TPI 100-136A-J**<br>**TPI 100-148A-J**|100 W|12 VDC(10.8 - 13.2 VDC)<br>15 VDC(13.5 - 16.5 VDC)<br>24 VDC(21.6 - 26.4 VDC)<br>28 VDC(25.2 - 30.8 VDC)<br>36 VDC(32.4 - 39.6 VDC)<br>48 VDC(43.2 - 52.8 VDC)|8'340 mA<br>6'670 mA<br>4'170 mA<br>3'580 mA<br>2'780 mA<br>2'090 mA|91 %<br>92 %<br>92 %<br>92 %<br>91 %<br>91 %| **Page 1 / 5** **April 16, 2026** **www.tracopower.com** **TPI 100A Series, 100 Watt** ## **Input Specifications** |Input Voltage|- AC Range|Operational Range:|85 - 264 VAC(Full Range)| |---|---|---|---| |||Rated Range:|100 - 240 VAC(Full Range)| ||- DC Range|Operational Range:|120 - 370 VDC(Designed for, no certification)| |||Polarity:|+DC: L / –DC: N| |Input Frequency||Operational Range:|47 - 440 Hz| |||Certified:|50/60 Hz| |Power Consumption|- No load & Vin = 230 VAC||300 mW max.(Ready to meet ErP directive)| ||- No load & Vin = 115 VAC||300 mW max.| |Input Current|- Full load & Vin = 230 VAC||550 mA max.| ||- Full load & Vin = 115 VAC||1'150 mA max.| |Input Inrush Current|- At 230 VAC||100 A max.| ||- At 115 VAC||55 A max.| |Power Factor|- At 230 VAC||0.95 min.| ||- At 115 VAC||0.95 min.| |Input Protection|||T 3.15 A / 250 VAC(Internal Fuse in L & N)| |Recommended Input Fuse|||(The need of an external fuse has to be assessed| ||||in the final application.)| |**Output Specifications**|||| |Output Voltage Adjustment|||±10%(By trim potentiometer)| ||||Output power must not exceed rated power!| |Voltage Set Accuracy|||±1% max.| |Regulation|- Input Variation (Vmin - Vmax)||0.2% max.| ||- Load Variation(0 - 100%)||0.5% max.| |Ripple and Noise||12 VDC model:|120 mVp-p typ.(w/ 10 µF X7R)| |(20 MHz Bandwidth)||15 VDC model:|150 mVp-p typ.(w/ 10 µF X7R)| |||24 VDC model:|160 mVp-p typ.(w/ 1 µF X7R)| |||28 VDC model:|180 mVp-p typ.(w/ 1 µF X7R)| |||36 VDC model:|190 mVp-p typ.(w/ 1 µF X7R)| |||48 VDC model:|340 mVp-ptyp. (w/ 0.1µF X7R)| |Capacitive Load||12 VDC model:|6'950 µF max.| |||15 VDC model:|4'450 µF max.| |||24 VDC model:|1'750 µF max.| |||28 VDC model:|1'280 µF max.| |||36 VDC model:|770 µF max.| |||48 VDC model:|430µF max.| |Minimum Load|||Not required| |Temperature Coefficient|||±0.02 %/K max.| |Hold-up Time|- At 230 VAC||22 ms min.| ||- At 115 VAC||22 ms min.| |Start-up Time|- At 230 VAC||1'000 ms max.| ||- At 115 VAC||1'000 ms max.| |Short Circuit Protection|||Continuous,Automatic recovery| |Output Current Limitation|||115 - 150% of Iout max.| |Overvoltage Protection|||115 - 135% of Vout nom.| |Transient Response|- Response Deviation||3% max.(50% to 75% Load Step)| ||- Response Time||500 µs typ.(50% to 75% Load Step)| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 5** **April 16, 2026** **www.tracopower.com** **TPI 100A Series, 100 Watt** ## **Safety Specifications** |Standards|- IT / Multimedia Equipment|EN 60950-1| |---|---|---| |||EN 62368-1| |||IEC 60950-1| |||IEC 62368-1| |||UL 60950-1| |||UL 62368-1| ||- Certification Documents|www.tracopower.com/tpi100a-safety-cert| |Protection Class||Class I & II(Prepared): Reinforced Insulation| |||See application note: www.tracopower.com/info/protection-class.pdf| |EnergySource|- Output,acc. to 62368-1|ES1| |Power Source|- Output,acc. to 62368-1|PS3| |Pollution Degree||PD 2| |Over Voltage Category||OVC II| ## **EMC Specifications** |EMI (Emissions)|||EN 61000-6-4(Generic Industrial)| |---|---|---|---| ||- Conducted Emissions||EN 55011 class A(internal filter)| ||||EN 55011 class B(internal filter)| ||||EN 55032 class A(internal filter)| ||||EN 55032 class B(internal filter)| ||||FCC 47 Part 15 class A(internal filter)| ||||FCC 47 Part 15 class B(internal filter)| ||- Radiated Emissions||EN 55011 class A(internal filter)| ||||EN 55032 class A(internal filter)| ||||FCC 47 Part 15 class A(internal filter)| ||- Harmonic Current Emissions||EN 61000-3-2, class A| ||||EN 61000-3-2, class D| ||- Voltage Fluctuations & Flicker||EN 61000-3-3| |EMS (Immunity)|||EN 55024(IT Equipment)| ||||EN 55035(Multimedia)| ||- Electrostatic Discharge|Air:|EN 61000-4-2, ±8 kV, perf. criteria A| |||Contact:|EN 61000-4-2, ±6 kV, perf. criteria A| ||- RF Electromagnetic Field||EN 61000-4-3, 20 V/m, perf. criteria A| ||- EFT (Burst) / Surge||EN 61000-4-4, ±2 kV, perf. criteria A| |||L to L:|EN 61000-4-5, ±1 kV, perf. criteria A| ||- Conducted RF Disturbances||EN 61000-4-6, 20 Vrms, perf. criteria A| ||- PF Magnetic Field|Continuous:|EN 61000-4-8, 10 A/m, perf. criteria A| ||- Voltage Dips & Interruptions|230 VAC / 50 Hz:|EN 61000-4-11| ||||30%, 25 periods, perf. criteria A| ||||>95%, 0.5 periods, perf. criteria A| ||||>95%, 250 periods, perf. criteria B| |||115 VAC / 60 Hz:|EN 61000-4-11| ||||30%, 25 periods, perf. criteria A| ||||>95%, 0.5 periods, perf. criteria A| ||||>95%,250periods, perf. criteria B| |EMC / Environmental|- Certification Documents||www.tracopower.com/tpi100a-emc-cert| |**General Specifications**|||| |Relative Humidity|||95% max. (non condensing)| |Temperature Ranges|- Operating Temperature||–40°C to +80°C| ||- Storage Temperature||–40°C to +85°C| ||||(-40°C startup: 80% load max. at Vin >100 VAC| ||||-40°C startup: 100% load max. at Vin >200 VAC)| |Power Derating|- High Temperature||Depending on model| ||- Low Input Voltage||1.33 %/V below 100 VAC| |||See application note:|www.tracopower.com/tpi100a-cc| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 5** **April 16, 2026** **www.tracopower.com** **TPI 100A Series, 100 Watt** |CoolingSystem||Natural convection(20 LFM)| |---|---|---| |Altitude DuringOperation||5'000 m max.| |Regulator Topology||Flyback Converter| |SwitchingFrequency||45 - 75 kHz (PWM QR)| |Insulation System||Reinforced Insulation| |WorkingVoltage (rated)||344 VAC| |Isolation Test Voltage|- Input to Output, 60 s|3'000 VAC| ||- Input to Case or PE, 60 s|1'500 VAC| ||- Output to Case or PE,60 s|1'500 VAC| |Isolation Resistance|- Input to Output,500 VDC|100 MΩ min.| |Leakage Current|- Touch Current|300 µA max.| |(at 264 VAC)||| |Reliability|- Calculated MTBF|790'000 h(MIL-HDBK-217F, ground benign)| |Environment|- Vibration|IEC 60068-2-6| |||1 g, 3 axis, sine sweep, 10-55 Hz, 1 oct/min| ||- Mechanical Shock|IEC 60068-2-27| |||10 g, 3 axis, half sine, 11 ms| |||20g,3 axis,3 shocks| |HousingType||Open Frame| |MountingType||Chassis Mount| |Connection Type||Pin Connector| |Weight||156 g| |Environmental Compliance|- REACH Declaration|www.tracopower.com/info/reach-declaration.pdf| |||REACH SVHC list compliant| |||REACH Annex XVII compliant| ||- RoHS Declaration|www.tracopower.com/info/rohs-declaration.pdf| |||Exemptions: 7(a), 7(c)-I| |||(RoHS exemptions refer to the component| |||concentration only, not to the overall| |||concentration in the product (O5A rule).)| ||- SCIP Reference Number|f11746f8-c399-40bd-b2b3-fcd7fddaaf3d| |**Additional Information**||| |SupportingDocuments||www.tracopower.com/overview/tpi100a| |FrequentlyAsked Questions||www.tracopower.com/glossary-faq| |Glossary||www.tracopower.com/info/glossary.pdf| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 4 / 5** **April 16, 2026** **www.tracopower.com** **TPI 100A Series, 100 Watt** ## **Outline Dimensions** **==> picture [260 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> 76.2 (3.00)<br>69.80 (2.748)<br>1<br>3<br>4<br>1<br>Ø 3.2 TOP VIEW Voltage adjustment<br>(Ø 0.13)<br>)<br>2.00)( CON1 1.750(<br>50.8 44.45<br>CON2<br>**----- End of picture text -----**<br> ## Pin connectors |Pin connectors|Pin connectors|Pin connectors|Pin connectors| |---|---|---|---| |Input(CON1)||Output(CON2)|| |Pin<br>1|Function<br>Line|Pin*<br>12|Function<br>–Vout| |3|Neutral|,<br>3,4|+Vout| *Terminal rated for 10 A max. (at higher current connection has to be split) CON1: JST series mates with JST crimp terminal: SVH-21T-P1.1 and terminal housing: VHR-3N CON2: JST series mates with JST crimp terminal: SVH-21T-P1.1 and terminal housing: VHR-4N **==> picture [257 x 153] intentionally omitted <==** **----- Start of picture text -----**<br> FRONT VIEW<br>Dimension in mm (inch)<br>Tolerances: x.x ±0.50 (±0.02)<br> x.xx ±0.25 (±0.01)<br>Mounting screw locked torque: max. 5.0 kgfcm / 0.49 Nm<br>0.06)( 1.16)(<br>29.5<br>1.6 2.5 max. (0.10 max.)<br>**----- End of picture text -----**<br> Specifications can be changed without notice. © Copyright 2025 Traco Electronic AG Rev. April 16, 2026 **Page 5 / 5** www.tracopower.com
Updated at April 27, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →