TMPW 10-124
AC/DC PCB Mount Power Supply (PSU), 100 to 250VDC, ITE & Household, 1 Output, 10 W, 24 VDC, 417 mA
- Manufacturer: TRACO POWER
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: No SVHC (16-Jul-2019)
- Depth: 37mm
- Width: 27.5mm
- Height: 20mm
- Product Range: TMPW 10 Series
- No. of Outputs: 1 Output
- Output Power Max: 10W
- Input Voltage VAC: 90V AC to 305V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 417mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE & Household
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 11.69 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC/DC Power Supply** **TMPW 10 Series, 10 Watt** - **Compact PCB power module in 1.46" x 1.08" package** - **Wide input voltage range 90-305 VAC** - **Certified according to EN 60335-1 and IEC/EN/UL 62368-1** - **I/O-Isolation 4’000 VAC** - **Operating temperature range –40°C to +70°C** - **No load input power <0.1W (acc. ErP directive)** - **High efficiency up to 86%** - **Internal EN 55032 class B filter** - **Protection class II prepared** - **3-year product warranty** UL 62368-1 IEC 60335-1 IEC 62368-1 The TMPW 10 is a 10 Watt AC/DC series with an extended input range of 90-305 VAC and is suitable for industrial and household/building technology applications and comes in a compact encapsulated plastic case. The 305 VAC (277 VAC ±10%) threshold is derived from a 480 VAC three-phase supply voltage often used in heavy industrial applications. Through the increased voltage level, the drawn current from the load is effectively reduced, which allows for an overall more compact and lightweight design approach. They offer an I/O-isolation voltage of 4000 VAC, a high temperature range of -40 to +70°C and are prepared for protection class II applications. Additionally, an internal EN 55032 class B filter saves valuable board space for an otherwise often mandatory external filter setup. An energy efficient design (<0.1 Watt standby power consumption) and safety approvals according to IEC/EN/UL 62368-1 and EN 60335-1 make this series suitable for a wide range of industrial and household/building technology applications. |**Order Code**|**Output Power**<br>**max.**|**Output Voltage**<br>**nom.**|**Output Current**<br>**max.**|**Efficiency**<br>**typ.**| |---|---|---|---|---| |**TMPW 10-105**<br>**TMPW 10-112**<br>**TMPW 10-115**<br>**TMPW 10-124**|10 W|5 VDC<br>12 VDC<br>15 VDC<br>24 VDC|2'000 mA<br>833 mA<br>667 mA<br>417 mA|81 %<br>85 %<br>86 %<br>86 %| **Page 1 / 5** **April 16, 2026** **www.tracopower.com** **TMPW 10 Series, 10 Watt** ## **Input Specifications** Input Voltage - AC Range Operational Range: 90 - 305 VAC (Full Range) Rated Range: 100 - 277 VAC (Full Range) - DC Range Operational Range: 100 - 430 VDC Certified Range: 100 - 250 VDC Polarity: +DC: N / –DC: L (The rated range refers to 62368-1. For 60335-1 certification the rated input voltage is 100 - 240 VAC and DC input is not permitted.) |Input Frequency||Operational Range: 47 - 440 Hz| |---|---|---| |||Certified: 50/60 Hz| |Power Consumption|- No load & Vin = 230 VAC|100 mW max.(Ready to meet ErP directive)| ||- No load & Vin = 115 VAC|100 mW max.| |Input Current|- Full load & Vin = 230 VAC|140 mA max.| ||- Full load & Vin = 115 VAC|230 mA max.| |Input Inrush Current|- At 230 VAC|60 A max.| ||- At 115 VAC|30 A max.| |Recommended Input Fuse||1'600 mA(slow blow)| |||(The need of an external fuse has to be assessed| |||in the final application.)| ## **Output Specifications** |Voltage Set Accuracy||±2% max.| |---|---|---| |Regulation|- Input Variation (Vmin - Vmax)|0.2% max.| ||- Load Variation (0 - 100%)|1% max.(5 & 12 Vout models)| |||0.5 % max.(other models)| |Ripple and Noise||5 VDC model: 60 mVp-p max.(w/ 0.1 µF || 47 µF)| |(20 MHz Bandwidth)||12 VDC model: 120 mVp-p max.(w/ 0.1 µF || 47 µF)| |||15 VDC model: 150 mVp-p max.(w/ 0.1 µF || 47 µF)| |||24 VDC model: 240 mVp-pmax. (w/ 0.1µF || 47µF)| |Capacitive Load||5 VDC model: 3'500 µF max.| |||12 VDC model: 700 µF max.| |||15 VDC model: 390 µF max.| |||24 VDC model: 180µF max.| |Minimum Load||Not required| |Temperature Coefficient||±0.02 %/K max.| |Hold-upTime|- At 230 VAC|30 ms min.| |Start-up Time|- At 230 VAC|60 ms max.| ||- At 115 VAC|60 ms max.| |Short Circuit Protection||Continuous,Automatic recovery| |Output Current Limitation||140 - 235% of Iout max.| |Overvoltage Protection||105 - 145% of Vout nom. (ByZener diode)| |Transient Response|- Response Deviation|2% typ. / 3% max.(50% to 75% Load Step)| ||- Response Time|500 µs max.(50% to 75% Load Step)| ## **Safety Specifications** |Standards|- IT / Multimedia Equipment|EN 62368-1| |---|---|---| |||IEC 62368-1| |||UL 62368-1| ||- Household|EN 60335-1| |||IEC 60335-1| ||- Power Transformers|IEC 61558-1| |||IEC 61558-2-16| ||- Certification Documents|www.tracopower.com/tmpw10-safety-cert| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 5** **April 16, 2026** **www.tracopower.com** **TMPW 10 Series, 10 Watt** |Protection Class|||Class I & II(Prepared): Reinforced Insulation| |---|---|---|---| |||See application note:|www.tracopower.com/info/protection-class.pdf| |EnergySource|- Output,acc. to 62368-1||ES1| |Power Source|- Output,acc. to 62368-1||PS3| |Pollution Degree|||PD 2| |Over Voltage Category|||OVC II| |**EMC Specifications**|||| |EMI (Emissions)|- Conducted Emissions||EN 55032 class A(internal filter)| ||||EN 55032 class B(internal filter)| ||- Radiated Emissions||EN 55032 class A(internal filter)| ||||EN 55032 class B(internal filter)| ||- Harmonic Current Emissions||EN 61000-3-2, class A| ||- Voltage Fluctuations & Flicker||EN 61000-3-3| |EMS (Immunity)|||EN 61000-6-2(Generic Industrial)| ||||EN 55024(IT Equipment)| ||||EN 55035(Multimedia)| ||- Electrostatic Discharge|Air:|EN 61000-4-2, ±8 kV, perf. criteria A| |||Contact:|EN 61000-4-2, ±4 kV, perf. criteria A| ||- RF Electromagnetic Field||EN 61000-4-3, 10 V/m, perf. criteria A| ||- EFT (Burst) / Surge||EN 61000-4-4, ±2 kV, perf. criteria A| |||L to L:|EN 61000-4-5, ±1 kV, perf. criteria A| ||- Conducted RF Disturbances||EN 61000-4-6, 10 Vrms, perf. criteria A| ||- PF Magnetic Field|Continuous:|EN 61000-4-8, 30 A/m, perf. criteria A| ||- Voltage Dips & Interruptions|230 VAC / 50 Hz:|EN 61000-4-11| ||||30%, 25 periods, perf. criteria A| ||||60%, 10 periods, perf. criteria A| ||||>95%, 0.5 periods, perf. criteria A| ||||>95%, 250 periods, perf. criteria B| ||||100%, 0.5 periods, perf. criteria A| ||||100%, 1 period, perf. criteria A| ||||100%, 250 periods, perf. criteria B| |||115 VAC / 60 Hz:|EN 61000-4-11| ||||30%, 25 periods, perf. criteria A| ||||60%, 10 periods, perf. criteria A| ||||>95%, 0.5 periods, perf. criteria A| ||||>95%, 250 periods, perf. criteria B| ||||100%, 0.5 periods, perf. criteria A| ||||100%, 1 period, perf. criteria A| ||||100%,250periods, perf. criteria B| |EMC / Environmental|- Certification Documents||www.tracopower.com/tmpw10-emc-cert| ## **General Specifications** |Relative Humidity||95% max. (non condensing)| |---|---|---| |Temperature Ranges|- Operating Temperature|–40°C to +70°C| ||- Storage Temperature|–40°C to +85°C| |Power Derating|- High Temperature|2.5 %/K above 50°C| ||- Low Input Voltage|2.0 %/V below 100 VAC| |||See application note: www.tracopower.com/tmpw10-cc| |CoolingSystem||Natural convection(20 LFM)| |Altitude During Operation||5'000 m max.(acc. IEC 62368-1)| |||2'000 m max.(acc. IEC 60335-1)| |SwitchingFrequency||35 - 75 kHz (PWM,PFM)| |Insulation System||Reinforced Insulation| |WorkingVoltage (rated)||254 VAC| |Isolation Test Voltage|- Input to Output,60 s|4'000 VAC| |Leakage Current|- Touch Current|250µA max.| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 5** **April 16, 2026** **www.tracopower.com** **TMPW 10 Series, 10 Watt** |Reliability|- Calculated MTBF|450'000 h(MIL-HDBK-217F, ground benign)| |---|---|---| |WashingProcess||Not allowed| |Environment|- Vibration|IEC 60068-2-6| |||2 g, 3 axis, 60 min, 10-500 Hz, 10 min/cycle| ||- Mechanical Shock|IEC 60068-2-27| |HousingMaterial||Plastic resin(UL 94 V-0 rated)| |Potting Material||Silicone(UL 94 V-0 rated) (Hermetical sealed| |||structure,dust-proof onlynon water-proof)| |Pin Material||Brass| |Pin Surface Plating||Tin(120µm min.),matte| |HousingType||Plastic Case| |MountingType||PCB Mount| |Connection Type||THD(Through-Hole Device)| |Soldering Profile||Lead-Free Wave Soldering| |||270°C / 3 s max.| |Weight||31 g| |Environmental Compliance|- REACH Declaration|www.tracopower.com/info/reach-declaration.pdf| |||REACH SVHC list compliant| |||REACH Annex XVII compliant| ||- RoHS Declaration|www.tracopower.com/info/rohs-declaration.pdf| |||Exemptions: 7(c)-I| |||(RoHS exemptions refer to the component| |||concentration only, not to the overall| |||concentration in the product (O5A rule).)| ||- SCIP Reference Number|4a581b31-098c-465a-86ad-c16eed37056d| |**Additional Information**||| |SupportingDocuments||www.tracopower.com/overview/tmpw10| |FrequentlyAsked Questions||www.tracopower.com/glossary-faq| |Glossary||www.tracopower.com/info/glossary.pdf| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 4 / 5** **April 16, 2026** **www.tracopower.com** **TMPW 10 Series, 10 Watt** ## **Outline Dimensions** **==> picture [216 x 322] intentionally omitted <==** **----- Start of picture text -----**<br> 37.0<br>21.5 7.5 4.0<br>5 4 3<br>Bottom View<br>1 2<br>Ø0.6<br>Dimensions in mm<br>Tolerances: ±0.5<br>Pin diameter tolerance: ±0.05<br>3.25<br>21.0 27.5<br>20.0<br>3.5<br>**----- End of picture text -----**<br> |Pinout|Pinout| |---|---| |Pin|Single| |1|+Vout| |2|–Vout| |3|AC IN (L)| |4|AC IN (N)| |5|NC| |NC: Not connected|| © Copyright 2025 Traco Electronic AG Specifications can be changed without notice. Rev. April 16, 2026 **Page 5 / 5** www.tracopower.com
Updated at June 3, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →