TMM 60112C
AC/DC Enclosed Power Supply (PSU), Medical, 1 Outputs, 60 W, 12 VDC, 5 A
- Manufacturer: TRACO POWER
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:60W; Output Voltage - Output 1:12V; Output Current - Output 1:5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage
- SVHC: No SVHC (14-Jun-2023)
- Product Range: TMM 60C Series
- No. of Outputs: 1Outputs
- Output Power Max: 60W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 73.16 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC/DC Power Supply** **TMM 60C Series, 60 Watt** - **Fully encapsulated low profile plastic casing in chassis mount version** - **2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition** - **IT and industrial safety according to IEC/EN/UL 62368-1 and UL 508** - **Ready to meet ErP directive <0.5 W no load power consumption** - **–40°C start-up temperature** - **Safety class II prepared** - **Protection against over-temperature, overload and short circuit** - **3-year product warranty** UL 508 ES 60601-1 IEC 60601-1 UL 62368-1 IEC 62368-1 The TMM 60C Series of fully encapsulated 60 Watt AC/DC power supply modules feature a reinforced/double I/O isolation system according to latest medical safety standards 60601-3 3rd edition for 2 x MOPP (Means Of Patient Protection). The high efficiency and the use of highest grade components make the units suitable for an operating temperature range of –40°C to +60°C without load derating. EMI/EMC characteristics and the safety approval package qualify these modules not only for medical devices but also for demanding applications in transportation systems and for equipment in industrial an commercial environment. ## **Models** **==> picture [471 x 91] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Order Code|Output Power|Output Voltage|Output Current|Efficiency| |max.|nom.|max.|typ.| |TMM 60105C|51 W|5.1 VDC|10'000 mA|84 %| |TMM 60112C|12 VDC|5'000 mA|87 %| |TMM 60115C|15 VDC|4'000 mA|87 %| |60 W| |TMM 60124C|24 VDC|2'500 mA|87 %| |TMM 60148C|48 VDC|1'250 mA|88 %| **----- End of picture text -----**<br> ## **Options** **TMP-MK2** - Optional DIN-Rail Mounting Kit: www.tracopower.com/overview/tmp-mk2 **Page 1 / 5** **April 28, 2026** **www.tracopower.com** **TMM 60C Series, 60 Watt** ## **Input Specifications** |Input Voltage|- AC Range|Operational Range: 85 - 264 VAC(Full Range)| |---|---|---| |||Rated Range: 100 - 240 VAC(Full Range)| ||- DC Range|Operational Range: 120 - 370 VDC(Designed for, no certification)| |||Polarity: irrelevant| |Input Frequency||Operational Range: 47 - 440 Hz| |||Certified: 50/60 Hz| |Power Consumption|- No load & Vin = 230 VAC|750 mW max.| ||- No load & Vin = 115 VAC|500 mW max.| |Input Current|- Full load & Vin = 230 VAC|5.1 VDC model: 530 mA max.| |||12 VDC model: 600 mA max.| |||15 VDC model: 600 mA max.| |||24 VDC model: 600 mA max.| |||48 VDC model: 600 mA max.| ||- Full load & Vin = 115 VAC|5.1 VDC model: 880 mA max.| |||12 VDC model: 1'000 mA max.| |||15 VDC model: 1'000 mA max.| |||24 VDC model: 1'000 mA max.| |||48 VDC model: 990 mA max.| |Input Inrush Current|- At 230 VAC|60 A max.| ||- At 115 VAC|30 A max.| |Input Protection||T 2 A / 250 VAC(Internal Fuse in L & N)| |Recommended Input Fuse||(The need of an external fuse has to be assessed| |||in the final application.)| ## **Output Specifications** |Voltage Set Accuracy||±2% max.| |---|---|---| |Regulation|- Input Variation (Vmin - Vmax)|1% max.| ||- Load Variation(0 - 100%)|1% max.| |Ripple and Noise||5.1 VDC model: 160 mVp-p max.| |(20 MHz Bandwidth)||12 VDC model: 180 mVp-p max.| |||15 VDC model: 230 mVp-p max.| |||24 VDC model: 360 mVp-p max.| |||48 VDC model: 720 mVp-p max.| |||5.1 VDC model: 110 mVp-p typ.| |||12 VDC model: 120 mVp-p typ.| |||15 VDC model: 150 mVp-p typ.| |||24 VDC model: 240 mVp-p typ.| |||48 VDC model: 480 mVp-ptyp.| |Capacitive Load||5.1 VDC model: 8'000 µF max.| |||12 VDC model: 3'900 µF max.| |||15 VDC model: 3'300 µF max.| |||24 VDC model: 1'500 µF max.| |||48 VDC model: 680µF max.| |Minimum Load||Not required| |Temperature Coefficient||±0.02 %/K max.| |Hold-up Time|- At 230 VAC|50 ms min.| ||- At 115 VAC|10 ms min.| |Start-upOvershoot Voltage||5% max.| |Short Circuit Protection||Continuous,Automatic recovery| |Output Current Limitation||105% min. of Iout max.| |Overvoltage Protection||120% typ. of Vout nom. (ByZener diode)| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 2 / 5** **April 28, 2026** **www.tracopower.com** **TMM 60C Series, 60 Watt** ## **Safety Specifications** Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 - Industrial Control Equipment UL 508 - Medical Equipment EN 60601-1 IEC 60601-1 ANSI/AAMI ES 60601-1 CSA-C22.2, No 60601-1 2 x MOPP (Means Of Patient Protection) - Certification Documents www.tracopower.com/tmm60c-safety-cert Protection Class Class I & II (Prepared): Reinforced Insulation See application note: www.tracopower.com/info/protection-class.pdf Energy Source - Output, acc. to 62368-1 ES1 (5.1, 12 & 15 Vout model) ES2 (24 Vout model) ES3 (48 Vout model) Power Source - Output, acc. to 62368-1 PS3 Pollution Degree PD 2 Over Voltage Category OVC II ## **EMC Specifications** |EMI (Emissions)||EN 61000-6-3(Generic Residential)| |---|---|---| |||EN 61000-6-4(Generic Industrial)| ||- Conducted Emissions|EN 55011 class A(internal filter)| |||EN 55011 class B(internal filter)| |||EN 55032 class A(internal filter)| |||EN 55032 class B(internal filter)| |||FCC 47 Part 15 class A(internal filter)| |||FCC 47 Part 15 class B(internal filter)| ||- Radiated Emissions|EN 55011 class A(internal filter)| |||EN 55011 class B(internal filter)| |||EN 55032 class A(internal filter)| |||EN 55032 class B(internal filter)| |||FCC 47 Part 15 class A(internal filter)| |||FCC 47 Part 15 class B(internal filter)| |EMS (Immunity)||EN 61000-6-1(Generic Residential)| |||EN 61000-6-2(Generic Industrial)| |||EN 60601-1-2 edition 4(Medical Devices)| |||EN 55024(IT Equipment)| |||EN 55035(Multimedia)| ||- Electrostatic Discharge|Air: EN 61000-4-2, ±15 kV, perf. criteria A| |||Contact: EN 61000-4-2, ±8 kV, perf. criteria A| ||- RF Electromagnetic Field|EN 61000-4-3, 10 V/m, perf. criteria A| ||- EFT (Burst) / Surge|EN 61000-4-4, ±2 kV, perf. criteria A| |||L to L: EN 61000-4-5, ±1 kV, perf. criteria A| ||- Conducted RF Disturbances|EN 61000-4-6, 10 Vrms, perf. criteria A| ||- PF Magnetic Field|Continuous: EN 61000-4-8, 30 A/m, perf. criteria A| ||- Voltage Dips & Interruptions|230 VAC / 50 Hz: EN 61000-4-11| |||30%, 25 periods, perf. criteria A| |||>95%, 0.5 periods, perf. criteria A| |||>95%, 1 period, perf. criteria A| |||>95%,250periods, perf. criteria B| |EMC / Environmental|- Certification Documents|www.tracopower.com/tmm60c-emc-cert| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 3 / 5** **April 28, 2026** **www.tracopower.com** **TMM 60C Series, 60 Watt** ## **General Specifications** |Relative Humidity|||95% max. (non condensing)| |---|---|---|---| |Temperature Ranges|- Operating Temperature||–40°C to +80°C| ||- Storage Temperature||–40°C to +95°C| |Power Derating|- High Temperature||4.5 %/K above 60°C(5 Vout model)| ||||3.8 %/K above 60°C(other models)| |||See application note:|www.tracopower.com/tmm60c-cc| |CoolingSystem|||Natural convection(20 LFM)| |Altitude DuringOperation|||5'000 m max.| |SwitchingFrequency|||100 kHz typ. (PWM)| |Insulation System|||Reinforced Insulation| |WorkingVoltage (rated)|||240 VAC| |Isolation Test Voltage|- Input to Output,60 s||4'000 VAC| |Isolation Resistance|- Input to Output,500 VDC||1'000 MΩ min.| |Leakage Current|- Touch Current||100µA max.| |Reliability|- Calculated MTBF||125'000 h(MIL-HDBK-217F, ground benign)| |HousingMaterial|||Plastic resin(UL 94 V-0 rated)| |PottingMaterial|||Silicone(UL 94 V-0 rated)| |HousingType|||Plastic Case| |MountingType|||Chassis Mount| |Connection Type|||Screw Terminal| |Weight|||380 g| |Status Indicator|||Indicated by green LED| |Environmental Compliance|- REACH Declaration||www.tracopower.com/info/reach-declaration.pdf| ||||REACH SVHC list compliant| ||||REACH Annex XVII compliant| ||- RoHS Declaration||www.tracopower.com/info/rohs-declaration.pdf| ||||Exemptions: 6(c), 7(a)| ||||(RoHS exemptions refer to the component| ||||concentration only, not to the overall| ||||concentration in the product (O5A rule).)| ||- SCIP Reference Number||1ea9b5b6-1577-41c2-94c4-7ff00365fca8| |**Additional Information**|||| |SupportingDocuments|||www.tracopower.com/overview/tmm60c| |FrequentlyAsked Questions|||www.tracopower.com/glossary-faq| |Glossary|||www.tracopower.com/info/glossary.pdf| |Service Portal|||www.tracoserviceportal.com| All specifications valid at 230 VAC, resistive full load and +25°C after warm-up time, unless otherwise stated. **Page 4 / 5** **April 28, 2026** **www.tracopower.com** **TMM 60C Series, 60 Watt** ## **Outline Dimensions** **==> picture [268 x 274] intentionally omitted <==** **----- Start of picture text -----**<br> 67.8 (2.67) 38.0 (1.50)<br>50.0 (1.97) 8.9 5.0 11.8<br>(0.35) (0.20) (0.46)<br>3 4 5 6 7<br>Power OK LED 4 x ø3.5<br>Top view<br>1 2<br>Dimensions in mm (inch)<br>Tolerances ±0.5 (±0.02)<br>100.03.94)( 112.0)(4.41 90.03.54)(<br>11.0 (0.43)<br>6.0 (0.24)<br>**----- End of picture text -----**<br> **==> picture [106 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> Pinout<br>Pin Single Output<br>1 AC (N)<br>2 AC (L)<br>3 NC<br>4 +Vout<br>5 NC<br>6 –Vout<br>7 NC<br>**----- End of picture text -----**<br> NC: Not connected Wire dimension: 1.5 mm² (16 AWG) max. Note: The size of the wires has to be assessed in the fi nal application. Mounting screw tightening torque: Max. 0.5 Nm (5.1 kgfcm) Terminal screw tightening torque: Max. 0.5 Nm (5.1 kgfcm) © Copyright 2026 Traco Electronic AG Specifications can be changed without notice. Rev. April 28, 2026 **Page 5 / 5** www.tracopower.com
Updated at June 7, 2026
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →