TMM 40215
AC/DC PCB Mount Power Supply (PSU), Medical, 2 Output, 40 W, 15 VDC, 1.33 A, -15 VDC
- Manufacturer: TRACO POWER
- Product type: AC / DC PCB Mount Power Supplies
- Depth: 88.9mm
- Width: 63.5mm
- Height: 30mm
- Product Range: TMM 40 Series
- No. of Outputs: 2 Output
- Output Power Max: 40W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Approvals: Medical
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.33A
- Output Current - Output 2: 1.33A
- Output Voltage - Output 1: 15VDC
- Output Voltage - Output 2: -15VDC
| Delivery and price | |
|---|---|
| Units per pack | 500 |
| Price | 62.94 € |
| Current stock | 10+ |
| Lead time | 30 days |
## AC/DC Power Modules TMM 40 Series, 40 Watt ## Features - Fully encapsulated low profile plastic casing in PCB- or chassis mount version c(U)us CB C ~~€~~ dus Scheme UL 508 UL 60950-1 UL 60950-1 UL 60601-1 ES 60601-1 - 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition - IT and industrial safety according to IEC/UL 60950-1 and UL 508 - Ready to meet ErP directive - <0.3W no load power consumption - -40°C start-up temperature - Safety class II prepared - Protection against over-temperature overload and short circuit - 3-year product warranty ## Also see: ## TMM 24 Series, 24 Watt www.tracopower.com/products/tmm24.pdf ## TMM 60 Series, 60 Watt www.tracopower.com/products/tmm60.pdf The TMM 40 Series of fully encapsulated 40 Watt AC/DC power supply modules feature a reinforced/double I/O isolation system according to latest medical safety standards 60601-3 3rd edition for 2 x MOPP (Means Of Patient Protection). The high efficiency and the use of highest grade components make the units suitable for an operating temperature range of –40°C to +60°C while it goes up to 75°C with 50% load derating. EMI/EMC characteristics and the safety approval package qualify these modules not only for medical devices but also for demanding applications in transportation systems and for equipment in industrial an commercial environment. |Order code<br>PCB mount<br>Chassis mount|Order code<br>PCB mount<br>Chassis mount|Output power<br>max.|Output 1|Output 2|Efficiency| |---|---|---|---|---|---| |TMM 40105<br>TMM 40112<br>TMM 40115<br>TMM 40124<br>TMM 40212<br>TMM 40215|TMM 40105C<br>TMM 40112C<br>TMM 40115C<br>TMM 40124C<br>TMM 40212C<br>TMM 40215C|40 W|5.0 VDC / 8000 mA<br>12 VDC / 3330 mA<br>15 VDC / 2660 mA<br>24 VDC / 1660 mA<br>+12 VDC / 1660 mA<br>+15 VDC / 1330 mA|–12 VDC / 1660 mA<br>–15 VDC / 1330 mA|83 %<br>83 %<br>83 %<br>84 %<br>84 %<br>84 %| Page 1 of 4 http://www.tracopower.com AC/DC Power Modules TMM 40 Series 40 Watt ||~~Input Specifications~~<br>Input voltage ranges<br>– nominal<br>100 – 240 VAC<br>– AC input<br>85 – 264 VAC<br>– DC Input<br>120 – 370 VDC<br>Input frequency<br>47 – 440 Hz<br>Input current at full load(115 VAC / 230 VAC nominal input)<br>690 mA / 415 mA typ.<br>Leakage current<br>80µA typ.<br>No-Loadpower consumption<br><0.3 W<br>External input fuse required(recommended value)<br>3 A slow blow typeor characteristic C<br>~~Output Specifications~~<br>Voltage set accuracy<br>±2% typ.<br>Minimum load<br>no minimum load required<br>Regulation<br>– Input variation<br>0.5% typ.<br>– Load variation (0-100%)<br>single output models:1.0% typ.<br>dual output models:2.0% typ.<br>Temperature coefficient<br>0.02 %/K<br>Ripple and noise(20 MHz bandwidth)<br>5.0 VDC model:<1.8% of Vout [Vp-p] max.<br>other models:<1.3% of Vout [Vp-p] max.<br>Current limitation<br>above 105 % of rated output current.<br>hicup, auto recovery<br>Overvoltageprotection byZehner diode(main output only)<br>120 % of Vout typ.<br>Short circuitprotection<br>continous<br>Max. capacitive load<br>5.0 VDC model:8000 µF<br>12 VDC model:3900 µF<br>15 VDC model:3900 µF<br>24 VDC model:680 µF<br>±12 VDC model:1500 µF(each output)<br>±15 VDC model:1000µF(each output)| |---|---| All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. Page 2 of 4 http://www.tracopower.com ## AC/DC Power Modules TMM 40 Series 40 Watt ## ~~General Specifications~~ |Temperature ranges<br>|– Operating (natural convection cooling 20 LFM)<br>|–40°C to +80°C| |---|---|---| ||– Power derating above +60°C<br>|3.75 %/K| ||– Storage (non operating)<br>|–40°C to +95°C| |Over temperature protection|<br>shutdown:|at 90°C| ||automatic recovery:|at approx 67°C| |Humidity(non condensing)||95 % rel max.| |Altitude duringoperation||5000 m| |Switchingfrequency (pulse width modulation PWM)<br>||130 kHz typ.| |Hold-up time|115 VAC:|25 ms typ.| ||230 VAC:|80 ms typ.| |Isolation voltage<br>|– Input/Output<br>|4‘000 VAC| |Isolation resistance<br>|– at 500 VDC<br>|1‘000 MOhm| |Reliability/calculated MTBF(MIL-HDBK-217F, at +25°C,ground benign)<br>||>200’000 h| |EMI / RFI conducted and radiated<br>||EN 55022, class B, FCC part 15, level B| |||EN 55011 class B| |Electromagnets compatibility|– Electrostatic discharge ESD<br>|IEC / EN 61000-4-2, 8kV/4kV perf. criteria B| |(EMC), immunity<br>|– RF field immunity<br>|IEC / EN 61000-4-3, 10V/m perf. criteria A| ||– Electrical fast transients/burst immunity<br>|IEC / EN 61000-4-4, ± 2kV perf. criteria B| ||– Surge<br>|IEC / EN 61000-4-5, ± 1kV/± 2kV perf. criteria B| ||– Conducted RF<br>|IEC / EN 61000-4-6, 10 Vr.m.s perf. criteria B| ||– Magnetic field immunity<br>|IEC / EN 61000-4-8, 30A/mperf. criteria A| |Voltage dip and interruptions|according to EN 61000-4-11<br>|30%, 10ms perf. criteria B| |reference: 115 VAC / 60Hz|<br>|60%, 100ms perf. criteria C| |||95%, 5000msperf. criteria C| |Protection class II||acordingIEC/EN 60536| |Safety standards||UL 60950-1, IEC/EN 60950-1,| |||IEC/EN 60601-1 3rd edition, 2 x MOPP| |||ANSI/AAMI ES60601-1:2005(R)2012| |||UL 508for chassis mount version| |Safety approvals and<br>|– UL online certification (ES60601-1:2005(R)2012)<br>|www.ul.comFile e188913, copy:e188913qqhm2.pdf| |certifications<br>|– UL certificate (UL 60950-1)<br>|www.ul.comFile e188913, copy:e188913qqgq2.pdf| |<br>|– UL approval for UL 508 (chassis mount models only)www.ul.com-> certifications -> File: e322109<br> – CB certificate (60601-1 3rd edition 2 x MOPP)<br> www.tracopower.com/products/tmm24-cb60601.pdf<br>Pending|| ||– CB certificate (IEC/EN 60950-1)<br>|www.tracopower.com/products/tmm24-cb60950.pdf| |Casingmaterial||plastic resin + fiberglass(UL 94V-0 rated)| |Environmental compliance<br>|– Reach<br>|www.tracopower.com/products/reach-declaration.pdf| ||– RoHS<br>|RoHS directive 2011/65/EU| All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. Page 3 of 4 http://www.tracopower.com AC/DC Power Modules TMM 40 Series 40 Watt ## ~~Outline Dimensions~~ ## TMM 40: **==> picture [387 x 249] intentionally omitted <==** **----- Start of picture text -----**<br> for PCB mount: 63.5 (2.50)<br>15.24 12.70 12.70 15.24 30.0 (1.18)<br>(0.60) (0.50) (0.50) (0.60)<br>7 6 5 4 3<br>2 x M4 THD<br>15.9 (0.63) 31.6 (1.24)<br>Bottom view<br>2 1<br>27.94 (1.10) 27.94 (1.10) 0.5 (0.02) 6.0<br>(0.24)<br>31.75 (1.25)<br>5.0 (0.20)<br>(3.20) (3.50)<br>81.3 88.9<br>5.0 (0.20)<br>3.8 (0.15)<br>**----- End of picture text -----**<br> Pin diameter ø 1.0 mm (0.039) Weight: 310 g (10.94oz) ## TMM 40C: for chassis mount: **==> picture [446 x 258] intentionally omitted <==** **----- Start of picture text -----**<br> 63.8 (2.51) 34.1 (1.34) Pinout / Connection<br>50.0 (1.97) 6.9 5.0 11.8 Pin/con. Single Dual<br>(0.27) (0.20) (0.46)<br>1 AC (N) AC (N)<br>3 4 5 6 7 2 AC (L) AC(L)<br>4 x ø3.5 3 +Vout +Vout<br>4 No Pin / NC No Pin / NC<br>5 –Vout Common<br>6 No Pin / NC No Pin / NC<br>Top view 7 NC –Vout<br>NC = not to connect<br>1 2<br>Dimensions in[mm], () = Inches<br>Weight: 320 g (11.29oz) Tolerances = 0.5mm (0.02)<br>(3.94) (4.41) (3.62)<br>100.0 112.0 92.0<br>6.0 (0.24) 10.0 (0.39)<br>**----- End of picture text -----**<br> Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com Rev. August 22. 2014 Page 4 of 4 **www.tracopower.com** http://www.tracopower.com
Updated at February 9, 2023
TRACO Electronic AG, operating globally under the Traco Power brand, is a premier Swiss power supply specialist with over 35 years of industry expertise. Renowned for engineering high-quality power conversion products, the company delivers reliable, cost-effective solutions tailored to the exacting standards of industrial, medical, railway, and automation applications. The cornerstone of our Traco Power portfolio is an extensive selection of power conversion systems. Our offering is heavily focused on a vast array of high-performance AC/DC converters engineered to provide exceptional efficiency and safety for sensitive electronics. This is complemented by a robust lineup of DC/DC converters built to ensure stable, isolated power delivery in challenging environments. Beyond flagship power supplies, the Traco Power range includes specialized passive components and thermal management solutions essential for complete system integration. We supply power inductors, common mode chokes, and power line filters designed for rigorous EMC and RFI suppression, alongside natural convection heat sinks that guarantee optimal thermal performance and prolonged component lifespan.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →