TM3SAC5RG
SAFETY MODULE, 10V, 0.1A, SPRING
- Manufacturer: SCHNEIDER ELECTRIC
- Product type: Controller Accessories
- SVHC:No SVHC (15-Jan-2019)
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 233.16 € |
| Current stock | 10+ |
| Lead time | 28 days |
Product data sheet Characteristics Modicon TM3 Safety module - 1 Function, Cat 3 PL d/SIL CL2 (spring) 24Vdc ## TM3SAC5RG ## Main ||Main| |---|---| ||Range of product<br>Modicon TM3 Safety| ||Product or component<br>Safety module| ||type| ||Device short name<br>TM3SAC| ||Safety module<br>For emergency stop and switch monitoring| ||application| ||Function of module<br>Emergency stop monitoring 1-channel wiring| ||Emergency stop monitoring 2-channel wiring| ||Monitoring of a movable guard with 2 switches and| ||automatic start| ||Safety level<br>Can reach PL d/category 3 EN/ISO 13849-1 2008| |Complementary<br>Safety reliability data<br>Synchronisation time between inputs<br>Connections - terminals<br>Output type<br>Number of safety circuits<br>Maximum switching voltage<br>[Us] rated supply voltage<br>Power consumption in W<br>Input protection type<br>[Uc] control circuit voltage<br>Maximum cable distance between devices<br>Breaking capacity<br>Breaking capacity<br>Output thermal current|Can reach PL d/category 3 EN/ISO 13849-2 2012<br>Can reach SILCL 2 EN/IEC 62061 2005<br>Can reach SIL 2 EN/IEC 61508 2010<br>DC = 95 % EN/ISO 13849-1<br>SFF = 95 % IEC 61508-1<br>HFT = 1 IEC 61508-1<br>Type = A IEC 61508-1<br>PFHd = 5E-9 1/h IEC 61508-1<br>PFHd = 30E-9 1/h IEC 61508-1<br>MTTFd = 500 years EN/ISO 13849-1<br>MTTFd = 85 years EN/ISO 13849-1<br>Unlimited<br>Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible<br>without cable end 13-14, 23-24, 33-34<br>Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid<br>without cable end 13-14, 23-24, 33-34<br>Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible<br>with cable end, with bezel 13-14, 23-24, 33-34<br>Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible<br>with cable end, without bezel 13-14, 23-24, 33-34<br>Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible<br>with cable end, with double bezel 13-14, 23-24, 33-34<br>Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible<br>without cable end other terminals<br>Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid<br>without cable end other terminals<br>Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible<br>with cable end, with bezel other terminals<br>Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible<br>with cable end, without bezel other terminals<br>Relay instantaneous opening, 3 NO, potential free<br>3 NO relay instantaneous opening<br>230 V AC-15 50 Hz relay instantaneous opening)<br>24 V DC-13 relay instantaneous opening)<br>24 V - 15...20 % DC<br>0.2 W 5 V DC<br>3.6 W 24 V DC<br>Internal, electronic<br>24 V DC<br>98.43 ft (30 m)<br>360 VA holding AC-15 B300 relay output<br>3600 VA inrush AC-15 B300 relay output<br>4 A 24 V 50 ms DC-13 relay output<br>6 A per relay for relay output| ## Complementary Jan 13, 2021 1 |[Ith] conventional free air thermal current|18 A| |---|---| |Associated fuse rating|4 A gG or gL relay output EN/IEC 60947-5-1| ||6 A fast blow relay output EN/IEC 60947-5-1| |Minimum output current|10 mA relay output| |Output voltage|10 V relay output| |Maximum response time on input open|40 ms| |[Ui] rated insulation voltage|300 V 2)IEC 60647-5-1| |[Uimp] rated impulse withstand voltage|4 kV III IEC 60647-5-1| |Current consumption|100 mA 24 V DC external supply| |Local signalling|User 6 LEDs green/red)| |Electrical connection|Spring terminal| |Standards|EN/ISO 13849-1:2008| ||EN/ISO 13849-2:2012| ||EN/IEC 62061:2005| ||EN/IEC 61508:2010| ||EN/IEC 60947-5-1:2010| ||EN/IEC 61131-2:2007| ||EN/IEC 60204-1:2005| ||EN/IEC 60204-1:2009/A1| ||IEC 61010-1:2010| ||EN 50581:2012| |Product certifications|UL 61010-2-201| ||CSA 61010-2-201 (pending)| ||TÜV| ||EAC| ||CSA Haz Loc Class 1 Division 2 (pending)| ||ANSI Haz Loc Class 1 Division 2 (pending)| ||RCM| |Marking|CSA| ||EAC| ||CE| ||RCM| ||UL| ||TÜV| ||EFUP 10| |Electromagnetic compatibility|Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming| ||to EN/IEC 61000-4-2| ||Electrostatic discharge immunity test - test level: 6 kV (contact discharge)| ||conforming to EN/IEC 61000-4-2| ||Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) EN/IEC| ||61000-4-3| ||Susceptibility to electromagnetic fields 3 V/m 1.4 GHz...2 GHz) EN/IEC| ||61000-4-3| ||Susceptibility to electromagnetic fields 1 V/m 2 GHz...3 GHz) EN/IEC 61000-4-3| ||Magnetic field at power frequency 30 A/m 50...60 Hz) EN/IEC 61000-4-8| ||Electrical fast transient/burst immunity test 3 kV power lines (DC)) EN/IEC| ||61000-4-4| ||Electrical fast transient/burst immunity test 2 kV I/O) EN/IEC 61000-4-4| ||1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC))| ||conforming to EN/IEC 61000-4-5| ||Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/| ||IEC 61000-4-6| ||Radiated emission 40 dBµV/m 24 V)class A EN 55011| ||Radiated emission 47 dBµV/m 24 V)class A EN 55011| |Mounting support|Top hat type TH35-7.5 rail IEC 60715| ||Top hat type TH35-15 rail IEC 60715| ||Wall mount using attached fasteners| |Height|3.70 in (94 mm)| |Depth|2.87 in (73 mm)| |Maximum Width|1.72 in (43.7 mm)| |Net Weight|0.42 lb(US) (0.19 kg)| 2 ## Environment |Environment|| |---|---| |Standards|EN/IEC 60947-1| ||EN 60204-1| ||EN/ISO 13850| ||EN 1088/ISO 14119| ||EN/IEC 60947-5-1| |Resistance to electrostatic discharge|8 KV in air EN/IEC 61000-4-2| ||6 kV on contact EN/IEC 61000-4-2| |Resistance to electromagnetic fields|9.14 V/M (10 V/m) 80 MHz...1 GHz EN/IEC 61000-4-3| ||2.74 V/M (3 V/m) 1.4 GHz...2 GHz EN/IEC 61000-4-3| ||0.91 V/m (1 V/m) 2 GHz...3 GHz EN/IEC 61000-4-3| |Resistance to magnetic fields|30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8| |Resistance to fast transients|3 KV power lines (DC) DC)EN/IEC 61000-4-4| ||2 kV I/O linesEN/IEC 61000-4-4| |Surge withstand|1 KV power lines (DC) differential mode EN/IEC 61000-4-5 DC| ||1 kV power lines (DC) common mode EN/IEC 61000-4-5 DC| |Resistance to conducted disturbances|10 V 0.15...80 MHz EN/IEC 61000-4-6| |Electromagnetic emission|Radiated emissions 50 dBµV/m class A 24 V DC)30…230 Hz IEC 61131-3| ||Radiated emissions 57 dBµV/m class A 24 V DC)230…1000 Hz IEC 61131-3| |Ambient air temperature for operation|14…131 °F (-10…55 °C) horizontal installation| |Ambient air temperature for storage|-13…158 °F (-25…70 °C)| |Relative humidity|10…95 %, without condensation (in operation)| ||10…95 %, without condensation (in storage)| |IP degree of protection|IP20 terminals)EN/IEC 60529| |Pollution degree|2| |Operating altitude|0...6561.68 ft (0...2000 m)| |Storage altitude|0.00…9842.52 ft (0…3000 m)| |Vibration resistance|+/- 3.5 mm 5…150 Hz)IEC 60068-2-6| |Shock resistance|15 gn 11 ms IEC 60068-2-27| |Mechanical robustness|Bumps 6 ms 300 shocks 25 gn) IEC 60068-2-27| ## Ordering and shipping details |Ordering and shipping detailsg and shipping detailsand shipping detailspping detailsing detailsg detailsdetails|| |---|---| |Category|22533 - M2XX PLC & ACCESSORIES| |Discount Schedule|MSX| |GTIN|00785901993285| |Nbr. of units in pkg.|1| |Package weight(Lbs)|0.58 lb(US) (0.26 kg)| |Returnability|No| |Country of origin|DE| ## Packing Units |Packing Unitsg UnitsUnits|| |---|---| |Unit Type of Package 1|PCE| |Package 1 Height|2.95 in (7.5 cm)| |Package 1 width|4.17 in (10.6 cm)| |Package 1 Length|4.92 in (12.5 cm)| |Unit Type of Package 2|S03| |Number of Units in Package 2|18| |Package 2 Weight|11.60 lb(US) (5.26 kg)| |Package 2 Height|11.81 in (30 cm)| |Package 2 width|11.81 in (30 cm)| |Package 2 Length|15.75 in (40 cm)| 3 |Offer Sustainability|||| |---|---|---|---| |Sustainable offer status|Green Premium product||| |California proposition 65|WARNING: This product can expose you to chemicals including: Lead and||WARNING: This product can expose you to chemicals including: Lead and| ||lead compounds, which is known to the State of California to cause cancer|lead compounds, which is known to the State of California to cause cancer|| ||and birth defects or other reproductive harm. For more information go to||| ||www.P65Warnings.ca.gov||| |REACh Regulation|REACh Declaration<br>iy||| |EU RoHS Directive|Pro-active compliance (Product out of EU RoHS legal scope)|iy|EU RoHS| ||Declaration||| |Mercury free|Yes||| |RoHS exemption information|Yes<br>iy||| |China RoHS Regulation|China RoHS Declaration<br>iy||| |Environmental Disclosure|Product Environmental Profile<br>ay||| |Circularity Profile|End Of Life Information<br>ay||| |WEEE|The product must be disposed on European Union markets following specific||| ||waste collection and never end up in rubbish bins.||| |PVC free|Yes||| 4 ## Product data sheet Dimensions Drawings ## TM3SAC5RG ## Dimensions (*) 8.5 mm/0.33 in when the clamp is pulled out. 5 ## Product data sheet Mounting and Clearance ## TM3SAC5RG ## Spacing Requirements Mounting on a Rail Incorrect Mounting Mounting on a Panel Surface (1) Install a mounting strip Mounting Hole Layout 6 Product data sheet Connections and Schema ## TM3SAC5RG ## Emergency Stop Wiring Diagram S1 : Emergency stop switch S2 : Start switch (1) Safety outputs (2) For automatic start, directly connect [Y1] and [Y2] terminals (3) Fuses. Refer to technical specifications for fuse values - (4) Non-safety related TM3 Bus communication with logic controller 7
Updated at April 29, 2026
Schneider Electric is a recognized global leader in digital automation and energy management, dedicated to bridging progress and sustainability. By integrating world-leading process and energy technologies, they empower industries, infrastructure, and facilities to maximize efficiency and reliability. The company is renowned across the electronics and electrical sectors for manufacturing robust, innovative control and protection components that drive the digital transformation of industrial systems. Our comprehensive portfolio of Schneider Electric products strongly focuses on high-performance switching and automation control. We carry an extensive selection of relays, including hundreds of power relays, solid-state relays, contactors, and critical safety relays designed for demanding operational environments. For automation and process control applications, the range provides essential equipment such as motor starters, visual signal indicator units, process controllers, and versatile industrial switch accessories. To ensure the safety and integrity of electrical installations, we also supply a robust lineup of Schneider Electric circuit protection devices. This includes a wide array of thermal-magnetic circuit breakers, specialized fuse holders, and residual current devices. Supported by precision panel instrumentation, dependable AC/DC converters, and specialized DIN rail terminal blocks, our offering equips engineers with the critical components required for comprehensive industrial control and energy management solutions.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →