Image not available
Illustrative purposes only
TGR600-12
AC/DC Enclosed Power Supply (PSU), 1 Outputs, 600 W, 12 V, 50 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TIGER POWER SUPPLIES
- Product type: AC / DC Enclosed Power Supplies
- SVHC: To Be Advised
- Product Range: TGR600 Series
- No. of Outputs: 1Outputs
- Output Power Max: 600W
- Current, Output 4: -
- Input Voltage VAC: 176V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 50A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 85.57 € |
| Current stock | 10+ |
| Lead time | 30 days |
**600W Enclosed Switching Power Supply TGR600-XX, TGR600-XX-Q Series** ## **FEATURES** - **Input voltage Range: 176 - 264VAC or 240 - 373VDC** - **Accepts AC or DC input (dual-use of same terminal)** - **Operating ambient temperature range: -30** ℃ **to +60** ℃ - **Compact size with a low 1U profile** - **LED indicator for power on** - **Operating up to 5000m altitude** - **Over-temperature protection, output short circuit, overcurrent, over-voltage protection** - **Safety according to IEC/EN/UL62368, GB4943** - **Withstand 300VAC surge input for 5s** - **Built-in DC fan** - **Remote sense function** _**TGR600-XX series is one of**_ **Tiger Power's** _**enclosed AC-DC switching power supply. It features AC input and at the same time accepts DC input voltage, cost-effective, low no load power consumption, high efficiency and high reliability. These converters offer excellent EMC performance and meet IEC/ EN61000-4, CISPR32/EN55032, IEC/UL/EN62368, GB4943 standards and they are widely used in areas of industrial, LED, street light control, electricity, security, telecommunications, smart home, etc.**_ ## **Selection Guide** |**Selection** **Guide**|**Selection** **Guide**|**Selection** **Guide**|**Selection** **Guide**|**Selection** **Guide**|**Selection** **Guide**|| |---|---|---|---|---|---|---| |**Certification**|**Part** **No.***|**Output**<br>**Power(W)**|**Nominal** **Output**<br>**Voltage** **and** **Current**<br>**(Vo/Io)**|**Output** **Voltage**<br>**Adjustable** **Range(V)**|**Efficiency** **at** **230VAC**<br>**(%)** **Typ.**|**Max.** **Capacitive** **Load**<br>**(µF)**| |**CE**|**TGR600-12**|**600**|**12V/50A**|**10** **-13.5**|**85**|**3000**| ||**TGR600-15**|**600**|**15V/40A**|**13.5** **-16.5**|**86**|**3000**| ||**TGR600-24**|**600**|**24V/25A**|**22** **-** **26.4**|**87**|**1000**| ||**TGR600-27**|**599.4**|**27V/22.2A**|**24** **-** **30**|**87**|**1000**| ||**TGR600-36**|**597.6**|**36V/16.6A**|**32** **-** **40**|**87**|**1000**| ||**TGR600-48**|**600**|**48V/12.5A**|**43** **-** **56**|**88**|**1000**| |**Note**:***Use** **suffix** **“Q”** **for** **conformal** **coating.**||||||| **Note** : ***Use suffix “Q” for conformal coating.** ## **Input Specifications** |**Input** **Specifications**|**Input** **Specifications**|**Input** **Specifications**|**Input** **Specifications**|**Input** **Specifications**|**Input** **Specifications**|**Input** **Specifications**| |---|---|---|---|---|---|---| |**Item**|**Operating** **Conditions**||**Min.**|**Typ.**|**Max.**|**Unit**| |**Input** **Voltage** **Range**|**AC** **input**||**176**|**--**|**264**|**VAC**| ||**DC** **input**||**240**|**--**|**373**|**VDC**| |**Input** **Voltage** **Frequency**|||**47**|**--**|**63**|**Hz**| |**Input** **Current**|**230VAC**||**--**|**7.5**|**8.5**|**A**| |**Inrush** **Current**|**230VAC**|**Cold** **start**|**--**|**60**|**--**|| |**Leakage** **Current**|**240VAC**||**--**|**--**|**2**|**mA**| |**Hot** **Plug**|||**Unavailable**|||| ## **Output Specifications** |**Output** **Specifications**|**Output** **Specifications**|**Output** **Specifications**|**Output** **Specifications**|**Output** **Specifications**|**Output** **Specifications**|**Output** **Specifications**| |---|---|---|---|---|---|---| |**Item**|**Operating** **Conditions**||**Min.**|**Typ.**|**Max.**|**Unit**| |**Output** **Voltage** **Accuracy**|**Full** **load** **range**|**12V/15V/24V/27V**<br>**36V/48V**|**--**|**±1**|**--**|**%**| |**Line** **Regulation**|**Rated** **load**||**--**|**±0.5**|**--**|| |**Load** **Regulation**|**0%** **-** **100%** **load**||**--**|**±0.5**|**--**|| |**Output** **Ripple** **&** **Noise***|**20MHz** **bandwidth**|**12V/15V/24V/27V**|**--**|**150**|**--**|**mV**| **Page 1 of 4** **www.TigerPowerSupplies.com** **600W Enclosed Switching Power Supply TGR600-XX, TGR600-XX-Q Series** ~~eGCO~~ **Temperature Coefficient 36V/48V** ~~GG~~ **---±0.05200 ---%/** ℃ ~~a~~ **Minimum Load** ~~OO~~ **0 -- -- %** ~~pe~~ **Hold-up Time 230VAC -- 20 -- ms** ~~a~~ **Short Circuit Protection Recover time <3s after the short circuit disappear. Hiccup, continuous, self-recover** ~~a~~ **Over-current Protection 105%-180% Io, self-recover 12V** ≤ **16.2V** ( **Hiccup, self-recover** ) ~~a G~~ **15V** ≤ **21V** ( **Hiccup, self-recover** ) ~~eG~~ **24V** ≤ **32.4V** ( **Hiccup, self-recover** ) **Over-voltage Protection** ~~a G~~ **27V** ≤ **36.5V** ( **Hiccup, self-recover** ) ~~eG~~ **36V** ≤ **50V** ( **Hiccup, self-recover** ) ~~a G~~ **48V** ≤ **60V** ( **Hiccup self-recover** ) ~~eG~~ **Over Temperature Over-temperature Protection Activation -- -- 70 Protection* Over-temperature Protection Deactivation 40 -- --** ℃ ~~a~~ **Note** : **1. *The “Tip and barrel method” is used for ripple and noise test, output parallel 47uF electrolytic capacitor** ~~———~~ **and 0.1uF ceramic capacitor, please refer to Enclosed Switching Power Supply Application Notes for specific information. 2. *Over-temperature Protection needs to be tested under rated full load conditions. General Specifications Item Operating Conditions Min. Typ. Max. Unit** ~~eG~~ **Input - 1500 -- --** ~~ee~~ **Isolation Test Input-output Electric strength test for 1min., leakage current <10mA** ~~ee~~ **3000 -- -- VAC** ~~|~~ **output - 500** ~~**ee**~~ **--** ~~ee~~ **-Input -** ~~ee~~ **50** ~~ee~~ **--** ~~ee~~ **-Insulation** ~~pom~~ **Resistance Input - output At 500VDC** ~~re~~ **50 -- -- M** Ω ~~|~~ **output - 50** ~~|a~~ **--** ~~|~~ **--** ~~ee~~ **Operating Temperature -30 -- +60** ℃ **Storage Temperature -40 -- +85** ~~WEY |~~ **Operating** ~~tc~~ **Humidity** ~~t;TTTTCUT RES PowerPower SuppliesSupplies~~ **20 --** ~~|~~ **90** ~~||~~ **Non-condensing %RH Storage Humidity 10 -- 95** ~~yer po~~ **+40** ℃ **to +60** ℃ ~~ee~~ **2** ~~ee~~ **--** ~~ee~~ **-Operating temperature derating %/** ℃ **-20** ℃ **to -30** ℃ **5 -- -- Power Derating** ~~ff~~ **176VAC - 200VAC 0.833 -- -- Input voltage derating %/VAC 200VAC - 264VAC 0 -- --** ~~a~~ ~~**e** e~~ ~~**e** e~~ **Safety Certification** ~~ee~~ **IEC/UL/EN62368/GB4943** ~~eeeee a GO a~~ **Safety Standard** ~~CO~~ **Meet IEC/EN/UL62368/GB4943** ~~a~~ **Safety Class** ~~GO~~ **CLASS I MTBF MIL-HDBK-217F@25** ℃ **> 300,000 h** ~~a A F~~ ## **Mechanical Specifications** |**Case** **Material**|**Metal** **(SGCC)**| |---|---| |**Dimensions**|**267.30** **x** **106.00** **x** **40.00** **mm**| |**Weight**|**1100g** **(Typ.)**| |**Cooling** **Method**|**Forced** **air** **cooling**| ## **Electromagnetic Compatibility (EMC)** |**Electromagnetic** **Compatibility** **(EMC)**|**Electromagnetic** **Compatibility** **(EMC)**|**Electromagnetic** **Compatibility** **(EMC)**|**Electromagnetic** **Compatibility** **(EMC)**| |---|---|---|---| |**Emissions**|**CE**|**CISPR32/EN55032** **CLASS** **A**|| ||**RE**|**CISPR32/EN55032** **CLASS** **A**|| |**Immunity**|**ESD**|**IEC/EN** **61000-4-2** **Contact** **±6KV** **/Air** **±8KV**|**Perf.** **Criteria** **A**| ||**RS**|**IEC/EN** **61000-4-3** **3V/m**|**perf.** **Criteria** **B**| **Page 2 of 4** **www.TigerPowerSupplies.com** **600W Enclosed Switching Power Supply TGR600-XX, TGR600-XX-Q Series** |**TGR600-XX, TGR600-XX-Q Series**||| |---|---|---| |**EFT**|**IEC/EN** **61000-4-4** **±1KV**|**perf.** **Criteria** **A**| |**Surge**|**IEC/EN** **61000-4-5** **line** **to** **line** **±1KV/line** **to** **ground** **±2KV**|**perf.** **Criteria** **A**| |**CS**|**IEC/EN61000-4-6** **10** **Vr.m.s**|**perf.** **Criteria** **A**| |**Voltage dips, short interruptions**<br>**and voltage variations**|**IEC/EN61000-4-11** **0%,** **70%**|**perf.** **Criteria** **B**| ## **Remark A** : - **1, One magnetic beed should be coupled with the output load line during CE/RE testing;** - **2, When the power supply is used in the European Union or in applications that mandatory to meet the requirements of EN61000-3-2, users need to handle the harmonic current requirements, details please refer to** Tiger Power Supplies **1) The terminal equipment is used in the European Union.** - **2) The terminal equipment is connected to public mains supply with 220VAC or greater rated nominal voltage that mandatory to meet the requirements of EN61000-3-2.** - **3) The power supply is installed in terminal equipment with average or continuous input power greater than 75W.** - **4) The power supply belong to a part of lighting system.** ## **Product Characteristic Curve** **Note** : **This product is suitable for applications using forced air cooling; for applications in closed environment please consult** Tiger **Power Supplies** **Page 3 of 4** **www.TigerPowerSupplies.com** ## **600W Enclosed Switching Power Supply TGR600-XX, TGR600-XX-Q Series** ## **Dimensions and Recommended Layout** ## **TGR600-xx, TGR600-xx-Q Series** ## **Note:** **1. For additional information on Product Packaging please refer to www.TigerPowerSupplies.com** **2. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25** ℃ **, humidity<75%RH with nominal input voltage and rated output load;** **3. The ambient temperature derating of 5** ℃ **/1000m is needed for operating altitude greater than 2000m;** **4. All index testing methods in this datasheet are based on our company corporate standards;** **5. In order to improve the efficiency at high input voltage, there will be audible noise generated, but it does not affect product performance and reliability;** **6. We can provide product customization service, please contact our technicians directly for specific information;** **7. Products are related to laws and regulations: see "Features" and "EMC";** **8. The out case needs to be connected to PE ( ) of system when the terminal equipment in operating;** **9. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by qualified units;** **10. The power supply is considered a component which will be installed into a final equipment. All EMC tests should be confirmed with the final equipment. Please consult our FAE for EMC test operation instructions.** **Page 4 of 4** **www.TigerPowerSupplies.com**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →