Image not available
Illustrative purposes only
TECS65F-24
AC/DC Open Frame Power Supply (PSU), ITE, 1 Output, 66 W, 85V AC to 264V AC, Fixed
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: COSEL
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (23-Jan-2024)
- Product Range: TECS Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.75A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 66W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 67.41 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC-DC Power Supplies Open Frame** Tm GON PB YE Ed >) World wide Safety EMI Inrush OCP OVP Approvals current limiting ## **TECS-series** ## ~~a|~~ **Feature CE marking** Small and Lightweight High efficiency Harmonic attenuator (Complies with IEC61000-3-2) Universal input (85-264VAC) Low Voltage Directive RoHS Directive ## **UKCA marking** ## a Built-in inrush current, overcurrent and overvoltage protection circuits ClassII Electrical Equipment Safety Regulations RoHS Regulations ## **EMI** ## ~~H~~[a] **Safety agency approvals** Complies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part 15-B, FCC Part 18-B, VCCI-B UL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), EN62368-1 Complies with DEN-AN **EMS Compliance** : EN61204-3, EN61000-6-2 ## **5-year warranty (refer to Instruction Manual)** EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 **TECS-1** www.cosel.co.jp/en/ June 10, 2024 **TEC S 45 F** OO **-** O **==> picture [261 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> AC-DC Power Supplies Open Frame<br>TECS45F<br>|<br>R<br>Ais (D)C E EK =<br>**----- End of picture text -----**<br> ## **Ordering information** **==> picture [210 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2 3 4 5 6<br>1Series name<br>Example recommended EMI/EMC filter<br>EAM-03-000 2Single output<br>3Output wattage<br>| o~ 4Universal input<br>5Output voltage<br>6Optional Optional [[*][1]][[1]]<br>E2: Capacitor between Input<br>H : with the function to be<br>High voltage pulse noise type : EAP series<br>150KHz-1MHz(To safety ground the secondary<br>side ) : EAC series<br>*A higher current rating EMI/EMC filter N: with cover<br>may be recommended in view of the<br>other devices that could be connected<br>in parallel with the power supply.<br>**----- End of picture text -----**<br> - 6Optional Optional[[*][1]][[1]] E2: Capacitor between Input and Output is changed - H : with the function to be acceptable to output peak current (12V,24V) ## **ClassⅡ** This power supply is manufactured by SMD technology. The stress to PCB like twisting or bending causes the defect of the unit, so handle the unit with care. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. ||**MODEL**<br>~~a~~|**MODEL**<br>~~a~~|**TECS45F-5**|**TECS45F-12**|**TECS45F-12-H**|**TECS45F-24**|**TECS45F-24**| |---|---|---|---|---|---|---|---| |**INPUT**<br>~~P~~|**VOLTAGE[VAC]**<br>*2 <br>~~CS~~<br>~~P~~||85-264 1f(Refer to “Derating” and Instruction Manual 1.1)<br>||||| ||**CURRENT[A]**<br>~~P LU-_-E~~|**ACIN 100V**<br>~~LU-_-E~~|0.80typ<br>~~LU-_-E~~|0.90yp|||| |||**ACIN 230V**<br>~~LU-_-E~~<br>~~es~~|0.45typ<br>~~LU-_-E~~<br>~~es~~|0.50typ|||| ||**FREQUENCY[Hz]**<br>~~P~~<br>~~J~~<br>~~———————~~||50 / 60(45 - 66)<br><br>~~—————~~||||| ||**EFFICIENCY[%]**<br>~~———————~~|**ACIN 100V**<br>~~—————~~|90.0typ<br>~~—————~~|90.5typ<br>~~—————~~|90.5typ|91.5typ|91.5typ| |||**ACIN 230V**<br>~~—————~~<br>~~a~~|90.5typ<br>~~—————~~<br>~~a~~|91.5typ<br>~~—————~~|91.5typ|92.5typ|92.5typ| ||**INRUSH CURRENT[A]**<br>~~———————~~<br>~~PE~~|**ACIN 100V**<br>~~—————~~<br>~~a~~<br>~~PE~~|30typ (Io=100%)Ta=25Cat cold start<br>~~—————~~<br>~~a~~||||| |||**ACIN 230V**<br>~~PE~~|65typ (Io=100%)Ta=25Cat cold start||||| ||**LEAKAGE CURRENT[mA]**<br>~~tt~~||0.25max(ACIN 240V,60Hz,Io=100%,Accordingto IEC62368-1,and DEN-AN)||||| |**OUTPUT**<br>~~TO~~|**VOLTAGE[V]**<br>~~a~~||5<br>~~a~~|12|12|24|24| ||**CURRENT[A]**<br>*2 <br>~~LO~~||8.0<br>~~LO~~|3.8<br>~~LO~~|3.8(Peak 5.45)<br>~~LO~~|1.9<br>~~LO~~|1.9(Peak 2.75)| ||**LINE REGULATION[mV]**<br>*3 <br>~~a~~||20max<br>~~a~~|48max<br>~~OC~~|48max<br>~~OC~~|96max|96max| ||**LOAD REGULATION[mV]**<br>*3 <br>~~aa~~||40max<br>~~aa~~|100max<br>~~aa~~|100max|150max|150max| ||**RIPPLE[mVp-p]**<br>*4 <br>~~a~~|**-10 to +50**C<br>*5 <br>~~a~~<br>~~a ~~|240max<br>~~a~~<br> ~~a ~~|300max<br> ~~GC~~|300max<br>~~GC~~|360max<br>~~GC~~|360max| ||**RIPPLE NOISE[mVp-p]** *4 <br>~~a~~<br>~~TO~~|**-10 to +50**C<br>*5 <br>~~a ~~<br>~~a a~~|300max<br> ~~a~~<br>~~a~~|380max<br>~~A~~|380max|480max|480max| ||**TEMPERATURE REGULATION[mV]**<br>~~TO~~|**0 to +50**C<br>*5 <br>~~a a~~|50max<br>~~a~~|120max<br>~~A~~|120max|240max|240max| |||**-10 to +50**C<br>*5 <br>~~a a~~|60max<br>~~a~~|150max<br>~~A~~|150max|290max|290max| ||**DRIFT[mV]**<br>*6 <br>~~TO~~<br>~~a a~~<br>~~a~~||20max<br>~~a~~<br>~~OO~~|48max<br>~~A~~<br>~~OO~~|48max<br>~~OO~~|96max<br>~~OO~~|96max| ||**START-UP TIME[ms]**<br>~~TY~~||200typ (ACIN 100V,Io=100%)||||| ||**HOLD-UP TIME[ms]**<br>~~FY~~||10typ (ACIN 100V,Io=80%)/ 60typ (ACIN 230V,Io=100%)||||| ||**OUTPUT VOLTAGE SETTING[V]**<br>~~a~~||4.90 to 5.30|11.50 to 12.50|11.50 to 12.50|23.00 to 25.00|23.00 to 25.00| |**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**|**OVERCURRENT PROTECTION**<br>~~FY~~||Works over 105% of rating (works over 101% ofpeak current at option -H)and recovers automatically||||| ||**OVERVOLTAGE PROTECTION[V]** <br>~~a~~||5.50 to 6.50<br>~~a~~|13.20 to 15.60|13.20 to 15.60|26.40 to 31.20|26.40 to 31.20| ||**OPERATING INDICATION**<br>~~oY~~||Notprovided||||| ||**REMOTE SENSING**<br>~~ET~~||Notprovided||||| |**ISOLATION**|**INPUT-OUTPUT**<br>~~CT~~||3,000VAC 1minute,Cutoff current = 10mA,500VDC 50MWmin(At Room Temperature)||||| |**ENVIRONMENT**|**OPERATING TEMP.,HUMID.AND ALTITUDE** *2 <br>~~EY~~||-10 to +70C,20 - 90%RH(Non condensing), (Refer to “Derating”),5,000m(16,500feet)max||||| ||**STORAGE TEMP.,HUMID.AND ALTITUDE**<br>~~CY~~||-20 to +75C,20 - 90%RH(Non condensing),9,000m(30,000feet)max||||| ||**VIBRATION**<br>~~PT~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60minutes each alongX,Y and Z axis||||| ||**IMPACT**||196.1m/s2 (20G),11ms,once each X,Y and Z axis||||| |**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**|**AGENCY APPROVALS**<br>~~FY~~||UL62368-1,C-UL(equivalent to CAN/CSA-C22.2No.62368-1),EN62368-1,Complies with DEN-AN||||| ||**CONDUCTED NOISE**<br>*7 <br>~~PT~~||Complies with CISPR11-B,CISPR32-B,EN55011-B,EN55032-B,FCC Part 15-B,FCC Part 18-B,VCCI-B||||| ||**HARMONIC ATTENUATOR** *8 <br>~~ET~~||Complies with IEC61000-3-2(Class A) (No built-inpower factor correction)||||| |**OTHERS**|**CASE SIZE/WEIGHT**<br>~~CY~~||25.4X23.5X76.2mm[1.00X0.93X3.00 inches] (WXHXD)/ 60gmax(with cover : 80gmax)||||| ||**COOLING METHOD**<br>*2 <br>~~ET~~||Convection/Forced air(Requires external fan) (Refer to “Derating”)||||| - *1 The listed options may affect the published standard specifications. Please contact us for detailed product specifications. - *2 Derating is required. ( ) means peak current. There is a possibility that an internal device is damaged when the specification is exceeded. Please contact us about the detail. - *3 At low load conditions, the burst mode operation will start. To check load regulation, you will need to measure the characteristics at average mode with instruments. - *4 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from output terminal. (Refer to Instruction Manual) - *5 5V output product, the maximum temperature of 35C. 12V output product, the maximum temperature of 40C. - *6 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. - *7 When secondary circuit will be connected to earth, the spec will be changed. (Refer to Instruction Manual 2) - *8 Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details. - To meet the specification, do not operate overload condition. - Parallel operation is not possible. - Sound noise may be emitted from the power supply depending on operating conditions. **TECS-2** www.cosel.co.jp/en/ June 10, 2024 **TECS45F** ## **Block diagram** **==> picture [461 x 236] intentionally omitted <==** **----- Start of picture text -----**<br> FUSE<br>AC250V<br>5A INRUSH RECTIFIER<br>AC IN NOISE<br>CURRENT AND<br>85 - 264VAC FILTER<br>LIMIT FILTER<br>TRANSFORMER<br>RECTIFIER<br>CONTROL INVERTER AND DC OUT<br>FILTER<br>CURRENT<br>SENSING<br>Photocoupler<br>CONTROL<br>Photocoupler<br>OVER VOLTAGE<br>PROTECTION<br>**----- End of picture text -----**<br> ## **External view** **==> picture [232 x 249] intentionally omitted <==** **----- Start of picture text -----**<br> Standard type<br>Name plate<br>3 AC(L)<br>CN2 1<br>1 AC(N) 2 -VOUT<br>CN1 3<br>+VOUT<br>4<br>2- f 3.4 [ f 0.13]<br>Mounting Hole<br>3.2 69.8±0.5<br>[0.13] [2.75]<br>76.2<br>[3.0]<br>±0.5<br>25.4 [1.0] 19.0 [0.75]<br>3.2 [0.13]<br>20.5 [0.81]<br>3.0max [0.12max]<br>**----- End of picture text -----**<br> **==> picture [27 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Cover type<br>**----- End of picture text -----**<br> **==> picture [238 x 207] intentionally omitted <==** **----- Start of picture text -----**<br> Name plate<br>CN1<br>AC(L) 3 CN2<br>1<br>AC(N) 1 2 -Vout<br>3<br>+Vout<br>4<br>2- f 3.4 [ f 0.13]<br>Mounting Hole<br>5.25 69.8±0.5<br>[0.21] [2.75]<br>80.3<br>[3.16]<br>±0.5<br>30.7 [1.21] 19.0 [0.75]<br>5.85 [0.23]<br>27.6 [1.09]<br>**----- End of picture text -----**<br> Mating connector and terminal of CN1, CN2 |I/O Connector|I/O Connector|Matingconnector|Terminal|Mfr.| |---|---|---|---|---| |CN1|B2P3-VH|VHR-3N|Chain<br>Loose<br>SVH-21T-P1.1<br>BVH-21T-P1.1<br>:<br>:|J.S.T.| |CN2|B4P-VH|VHR-4N|Chain<br>Loose<br>SVH-21T-P1.1<br>BVH-21T-P1.1<br>:<br>:|J.S.T.| - Dimensions in mm, [ ]=inches - Tolerance : ± 1.5 [ ± 0.06] - Weight : 60g max (with cover : 80g max) - PCB Material / thickness : FR-4 / 1.1mm [0.04] - Optional Case Material : PBT - Maximum current per contact at CN2 is 5A. - There are two mounting holes. **TECS-3** www.cosel.co.jp/en/ June 10, 2024 **AC-DC Power Supplies Open Frame Ordering information - TEC S 65 F** OO **-** O **TECS65F** ~~|—~~ 1 2 3 4 5 6 **==> picture [108 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> R<br>Ais (D)C E EK<br>**----- End of picture text -----**<br> **==> picture [80 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> Example recommended EMI/EMC filter<br>EAC-03-000<br>|<br>High voltage pulse noise type : EAP series<br>150KHz-1MHz(To safety ground the secondary<br>side) : EAC series<br>*A higher current rating EMI/EMC filter<br>may be recommended in view of the<br>other devices that could be connected<br>in parallel with the power supply.<br>**----- End of picture text -----**<br> 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional[*][1] E2: Capacitor between Input and Output is changed H : with the function to be acceptable to output peak current (12V,24V) N: with cover ## **ClassⅡ** This power supply is manufactured by SMD technology. The stress to PCB like twisting or bending causes the defect of the unit, so handle the unit with care. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. ||**MODEL**<br>~~a~~|**MODEL**<br>~~a~~|**TECS65F-5**|**TECS65F-12**|**TECS65F-12-H**|**TECS65F-24**|**TECS65F-24-H**| |---|---|---|---|---|---|---|---| |**INPUT**|**VOLTAGE[VAC]**<br>*2 <br>~~Po~~||85 - 264 1f(Refer to “Derating” and Instruction Manual 3.1)||||| ||**CURRENT[A]**<br>~~a~~|**ACIN 100V**<br>~~a~~|1.00typ<br>~~a~~|1.25typ|||| |||**ACIN 230V**<br>~~a~~<br>~~ee~~|0.55typ<br>~~a~~<br>~~ee~~|0.70typ|||| ||**FREQUENCY[Hz]**<br>~~PO~~<br>~~a~~<br>~~ee~~||50 / 60(45 - 66)<br>~~es ee~~||||| ||**EFFICIENCY[%]**<br>~~a~~|**ACIN 100V**<br>~~ee~~|90.0typ<br>~~es ee~~|91.5typ<br>~~ee~~|91.5typ|92.5typ|92.5typ| |||**ACIN 230V**<br>~~ee~~|91.5typ<br>~~es ee~~|93.0typ<br>~~ee~~|93.0typ|93.5typ|93.5typ| ||**INRUSH CURRENT[A]**<br>~~a~~<br>~~Po~~|**ACIN 100V**<br>~~ee~~<br>~~[|~~<br>~~Po~~|30typ (Io=100%)Ta=25Cat cold start<br>~~es ee~~||||| |||**ACIN 230V**<br>~~Po~~|65typ (Io=100%)Ta=25Cat cold start||||| ||**LEAKAGE CURRENT[mA]**<br>~~fs~~||0.25max(ACIN 240V,60Hz,Io=100%,Accordingto IEC62368-1,and DEN-AN)||||| |**OUTPUT**<br>~~pF~~|**VOLTAGE[V]**<br>~~a~~<br>~~(n(n~~||5<br>~~(n(n~~|12<br>~~(n(n~~|12<br>~~(|~~|24<br>~~(|~~|24| ||**CURRENT[A]**<br>*2 <br>~~(n(n~~<br>~~Rs~~||10.0<br>~~(n(n~~<br>~~(QQ~~|5.45<br>~~(n(n~~<br>~~(QQ~~|5.45(Peak 7.50)<br>~~(|~~<br>~~(QQ~~|2.75<br>~~(|~~<br>~~|~~|2.75(Peak 3.75)| ||**LINE REGULATION[mV]**<br>*3 <br>~~(n(n~~<br>~~Rs~~||20max<br>~~(n(n~~<br>~~(QQ~~|48max<br>~~(n(n~~<br>~~(QQ~~|48max<br>~~(|~~<br>~~(QQ~~|96max<br>~~(|~~<br>~~|~~|96max| ||**LOAD REGULATION[mV]**<br>*3 <br>~~Rs~~<br>~~i~~<br>~~pFpm~~||40max<br>~~(QQ~~<br>~~pm~~|100max<br>~~(QQ~~<br>~~ET~~|100max<br>~~(QQ~~<br>~~ET~~|150max<br>~~|~~<br>~~ET~~|150max| ||**RIPPLE[mVp-p]**<br>*4 <br>~~pFpm~~|**-10 to 45**C*5 <br>~~pm~~|240max<br>~~pm~~|300max<br>~~ET~~<br>~~OO~~|300max<br>~~ET~~<br>~~ET~~|360max<br>~~ET~~<br>~~ET~~|360max| ||**RIPPLE NOISE[mVp-p]** *4<br>~~pF pm~~<br>~~pom~~<br>~~—_——————e~~|**-10 to 45**C *5 <br>~~pm~~<br>~~pom~~<br>~~—_——————e~~|300max<br>~~pm ~~<br>~~pom~~<br>~~—_——————e~~|380max<br> ~~ET~~<br>~~pom~~<br>~~OO~~<br>~~—_——————e~~|380max<br>~~ET~~<br>~~pom~~<br>~~ET~~<br>~~—_——————e~~|480max<br>~~ET~~<br>~~pom~~<br>~~ET~~<br>~~—_——————e~~|480max| ||**TEMPERATURE REGULATION[mV]**<br>~~—_——————e~~<br>~~es~~|**0 to +45**C *5 <br>~~—_——————e~~<br>~~a~~|50max<br>~~—_——————e~~<br>~~es~~|120max<br>~~OO~~<br>~~—_——————e~~|120max<br>~~ET~~<br>~~—_——————e~~|240max<br>~~ET~~<br>~~—_——————e~~|240max| |||**-10 to +45**C<br>*5 <br>~~—_——————e~~<br>~~a~~<br>~~es~~|60max<br>~~—_——————e~~<br>~~es~~<br>~~GQ~~|150max<br>~~—_——————e~~<br>~~GQ~~|150max<br>~~—_——————e~~<br>~~GQ~~|290max<br>~~—_——————e~~|290max| ||**DRIFT[mV]**<br>*6 <br>~~—_——————e~~<br>~~a~~<br>~~es~~||20max<br>~~—_——————e~~<br>~~es~~<br>~~GQ~~|48max<br>~~—_——————e~~<br>~~GQ~~|48max<br>~~—_——————e~~<br>~~GQ~~|96max<br>~~—_——————e~~|96max| ||**START-UP TIME[ms]**<br>~~es~~<br>~~PO~~||500typ (ACIN 100V,Io=100%)<br>~~GQ~~||||| ||**HOLD-UP TIME[ms]**<br>~~PO~~||10typ (ACIN 100V,Io=80%)/ 60typ (ACIN 230V,Io=100%)||||| ||**OUTPUT VOLTAGE SETTING[V]**<br>~~es~~||4.90 to 5.30<br>~~es~~|11.50 to 12.50<br>~~es~~|11.50 to 12.50<br>~~es~~|23.00 to 25.00<br>~~es~~|23.00 to 25.00| |**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**<br>~~LE~~|**OVERCURRENT PROTECTION**<br>~~Po~~<br>~~es~~||Works over 105% of rating (works over 101% ofpeak current at option -H)and recovers automatically<br>~~GQ~~<br>~~|~~||||| ||**OVERVOLTAGE PROTECTION[V]** <br>~~es~~||5.50 to 6.50<br>~~GQ~~|13.20 to 15.60<br>~~GQ~~|13.20 to 15.60<br>~~GQ~~|26.40 to 31.20<br>~~|~~|26.40 to 31.20| ||**OPERATING INDICATION**<br>~~es~~<br>~~PO~~||Notprovided<br>~~GQ~~<br>~~|~~||||| ||**REMOTE SENSING**<br>~~[rr~~<br>~~LE~~||Notprovided||||| |**ISOLATION**<br>~~LE~~|**INPUT-OUTPUT**<br>~~LE~~||3,000VAC 1minute,Cutoff current = 10mA,500VDC 50MWmin(At Room Temperature)||||| |**ENVIRONMENT**<br>~~LE~~|**OPERATING TEMP.,HUMID.AND ALTITUDE** *2 <br>~~LEPO~~||-10 to +70C,20 - 90%RH(Non condensing), (Refer to “Derating”),5,000m(16,500feet)max||||| ||**STORAGE TEMP.,HUMID.AND ALTITUDE**<br>~~PO~~||-20 to +75C,20 - 90%RH(Non condensing),9,000m(30,000feet)max||||| ||**VIBRATION**<br>~~Po~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60minutes each alongX,Y and Z axis||||| ||**IMPACT**<br>~~[rr~~||196.1m/s2 (20G),11ms,once each X,Y and Z axis||||| |**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**|**AGENCY APPROVALS**<br>~~PO~~||UL62368-1,C-UL(equivalent to CAN/CSA-C22.2No.62368-1),EN62368-1,Complies with DEN-AN||||| ||**CONDUCTED NOISE**<br>*7 <br>~~PO~~||Complies with CISPR11-B,CISPR32-B,EN55011-B,EN55032-B,FCC Part 15-B,FCC Part 18-B,VCCI-B||||| ||**HARMONIC ATTENUATOR** *8 <br>~~[rr~~||Complies with IEC61000-3-2(Class A) (No built-inpower factor correction)||||| |**OTHERS**<br>~~[~~|**CASE SIZE/WEIGHT**<br>~~Po~~<br>~~[~~||25.4X27.0X76.2mm[1.00X1.06X3.00 inches] (WXHXD)/ 70gmax(with cover : 90gmax)||||| ||**COOLING METHOD**<br>*2 <br>~~[~~||Convection/Forced air(Requires external fan) (Refer to “Derating”)||||| - *1 The listed options may affect the published standard specifications. Please contact us for detailed product specifications. - *2 Derating is required. ( ) means peak current. There is a possibility that an internal device is damaged when the specification is exceeded. Please contact us about the detail. - *3 At low load conditions, the burst mode operation will start. To check load regulation, you will need to measure the characteristics at average mode with instruments. - *4 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from output terminal. (Refer to Instruction Manual) - *5 5V, 12V output product, the maximum temperature of 40C. - *6 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. - *7 When secondary circuit will be connected to earth, the spec will be changed. (Refer to Instruction Manual 2) - *8 Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details. - To meet the specification, do not operate overload condition. - Parallel operation is not possible. - Sound noise may be emitted from the power supply depending on operating conditions. **TECS-4** www.cosel.co.jp/en/ June 10, 2024 **TECS65F** ## **Block diagram** **==> picture [461 x 236] intentionally omitted <==** **----- Start of picture text -----**<br> FUSE<br>AC250V<br>5A INRUSH RECTIFIER<br>AC IN NOISE<br>CURRENT AND<br>85 - 264VAC FILTER<br>LIMIT FILTER<br>TRANSFORMER<br>RECTIFIER<br>CONTROL INVERTER AND DC OUT<br>FILTER<br>CURRENT<br>SENSING<br>Photocoupler<br>CONTROL<br>Photocoupler<br>OVER VOLTAGE<br>PROTECTION<br>**----- End of picture text -----**<br> ## **External view** **==> picture [235 x 240] intentionally omitted <==** **----- Start of picture text -----**<br> Standard type Name plate<br>3 AC(L)<br>CN2<br>1<br>1 AC(N) 2 -VOUT<br>CN1 3<br>+VOUT<br>4<br>2- f 3.4[ f 0.13]<br>Mounting Hole<br>3.2 69.8±0.5<br>[0.13] [2.75]<br>76.2<br>[3.0]<br>±0.5<br>25.4 [1.0] 19.0 [0.75]<br>3.2 [0.13]<br>24.0 [0.94]<br>3.0max [0.12max]<br>**----- End of picture text -----**<br> **==> picture [236 x 227] intentionally omitted <==** **----- Start of picture text -----**<br> Cover type<br>Name plate<br>CN1<br>AC(L) 3 CN2<br>1<br>AC(N) 1 2 -Vout<br>3<br>+Vout<br>4<br>2- f 3.4[ f 0.13]<br>Mounting Hole<br>5.25 69.8±0.5<br>[0.21] [2.75]<br>80.3<br>[3.16]<br>±0.5<br>30.7 [1.21] 19.0 [0.75]<br>5.85 [0.23]<br>31.1 [1.22]<br>**----- End of picture text -----**<br> ## Mating connector and terminal of CN1, CN2 |I/O Connector|I/O Connector|Matingconnector|Terminal|M| |---|---|---|---|---| |CN1|B2P3-VH|VHR-3N<br><br>|Chain<br>Loose<br>SVH-21T-P1.1<br>BVH-21T-P1.1<br>:<br>:|J.S| |CN2|B4P-VH|VHR-4N<br><br>|Chain<br>Loose<br>SVH-21T-P1.1<br>BVH-21T-P1.1<br>:<br>:|J.S| - Dimensions in mm, [ ]=inches - Tolerance : ± 1.5 [ ± 0.06] - Weight : 70g max (with cover : 90g max) - PCB Material / thickness : FR-4 / 1.1mm [0.04] - Optional Case Material : PBT - Maximum current per contact at CN2 is 5A. - There are two mounting holes. **TECS-5** www.cosel.co.jp/en/ June 10, 2024 ## **TECS-series** ## **Assembling and Installation Method** ## Installation method - ¡ This power supply is manufactured by SMD technology. Do not touch any SMD components on the unit. Be especially careful when handling. - ¡ If using a metal chassis, keep proper insulation between the component and metal chassis, use the spacer of 8mm or more between bottom of power supply and metal chassis (except -N model). - If d1 and/or d2 are less than the value mentioned in right figure, insert an insulating sheet with reinforced insulation between the power supply unit and metal chassis (except -N model). - The following distance is not satisfactory for cooling condition. Please refer to “Derating” and Instruction Manual 4 for cooling method. - ¡ There is a possibility that it is not possible to cool enough when the power supply is used by the sealing up space as showing in right figure. - Please use it after confirming the temperature of points 1 of Instraction Manual 4. **==> picture [215 x 230] intentionally omitted <==** **----- Start of picture text -----**<br> d2<br>CN1<br>d1=8mm min<br>d2<br>CN1<br>d2<br>d2<br>d2=5mm min<br>d2<br>Case<br>Power supply<br>**----- End of picture text -----**<br> - ¡ Standard model can be mounted in the mounting position shown in the figure below. **==> picture [448 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> (A) (B) (C) (D) (E) (F)<br>CN1<br>CN1 CN1<br>CN1<br>CN1<br>Standard position<br>CN1<br>**----- End of picture text -----**<br> - ¡ Option-N model can be mounted in the mounting position shown in the figure below.The installation of (F) possible only forced air cooling. **==> picture [453 x 102] intentionally omitted <==** **----- Start of picture text -----**<br> (A) (B) (C) (D) (E) (F)<br>CN1<br>CN1 CN1<br>CN1<br>Standard position CN1<br>CN1<br>**----- End of picture text -----**<br> **TECS-6** www.cosel.co.jp/en/ June 10, 2024 ## **TECS-series** ## **Mounting Area** - ¡ The mounting screw should be M3. The hatched area shows the allowance of mounting area. **==> picture [256 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> 6.7<br>CN1<br>mounting area<br>(secondary side)<br>mounting area<br>(primary side) 6.7 Unit〔mm〕<br>R3.5<br>R3.5<br>6.7<br>6.7<br>**----- End of picture text -----**<br> - ¡ The mounting area (primary side) must be insulated from areas that user accessible parts of the final product, so if the enclosure is metal and the mounting components and spacers are metal, be careful to insulate them. - ¡ When installing, be careful to avoid contact with mounted components. - ¡ This product uses SMD technology. Please avoid the PCB installation method which includes the twisting stress or the bending stress. - ¡ Do not touch any SMD components on the unit and soldering points. ## **Derating** ## ¿ Derating curve for input voltage **==> picture [116 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>85 90<br>Input voltage [VAC]<br>Load factor [%]<br>**----- End of picture text -----**<br> ## ● TECS45F Ambient temperature derating curve at rated input (Reference value) **==> picture [219 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> ①②③④ ⑤<br>100<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>0<br>-10 0 10 20 30 35 40 45 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br> |Cooling method|Output voltage|Installation condition|Installation condition| |---|---|---|---| |||A,B,C,D,E|F| |Convection|5V|1|1| ||12V|2|1| ||24V|4|3| |Forced air<br>(0.5m3/min)|5V,12V,24V|5|| ## ● TECS65F Ambient temperature derating curve at rated input (Reference value) **==> picture [221 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> ①②③④ ⑤<br>100<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>0<br>-10 0 10 20 30 35 40 45 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br> |Cooling method|Output voltage|Installation condition|Installation condition|Installation condition| |---|---|---|---|---| |||A,B,C,E|D|F| |Convection|5V|3|3|2| ||12V|3|3|1| ||24V|4|3|3| |Forced air<br>(0.5m3/min)|5V,12V,24V|5||| **TECS-7** www.cosel.co.jp/en/ June 10, 2024 ## **TECS-series** ## ● TECS45F-N Ambient temperature derating curve at rated input (Reference value) **==> picture [219 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> ① ② ③<br>10080 NNNoO<br>60<br>40 eee eN<br>30<br>20 ee ee<br>0<br>Pt] TP Pe Pt Tt<br>-10 0 10 20 30 40 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br> ## ● TECS65F-N Ambient temperature derating curve at rated input (Reference value) **==> picture [219 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> ①② ③<br>10080 NGre<br>6040 ptt<br>30<br>20 ee| Pe PN<br>0<br>PTTtTeetit tt<br>-10 0 10 20 30 35 40 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br> **==> picture [217 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> Installation condition<br>Cooling method Output voltage<br>A,B,C,D,E F<br>5V 1<br>Convection 12V 1 -<br>24V 2<br>Forced air<br>5V,12V,24V 3<br>(0.5m [3] /min)<br>**----- End of picture text -----**<br> **==> picture [216 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> Installation condition<br>Cooling method Output voltage<br>A,B,C,D,E F<br>5V 1<br>Convection 12V 1 -<br>24V 2<br>Forced air<br>5V,12V,24V 3<br>(0.5m [3] /min)<br>**----- End of picture text -----**<br> ¡ In case of forced air cooling, ventilation must be uniform. ¡ In case of forced air cooling, ventilation must be uniform. ## **Instruction Manual** ~~OO~~ ◆ Please see catalog and instructionmanual before you use. Instruction Manual https://www.cosel.co.jp/redirect/catalog/en/TECS/ Before using our product https://en.cosel.co.jp/technical/caution/index.html |◆ Please see catalog and instructionmanual before you use.Please see catalog and instructionmanual before you use.|◆ Please see catalog and instructionmanual before you use.Please see catalog and instructionmanual before you use.|||||| |---|---|---|---|---|---|---| ||||**TECS**||**NOTICE**|| |Instruction Manual<br>https://www.cosel.co.jp/redirect/catalog/en/TECS/||||||| |Before using our product|Before using our product<br>https://en.cosel.co.jp/technical/caution/index.html|||||| |**Basic Characteristics Data**<br>~~Bee!~~|**Basic Characteristics Data**<br>~~Bee!~~|~~Bee!~~|~~Bee!~~|~~Bee!~~|~~Bee!~~|~~Bee!~~| |Model|Circuit method<br>Switching<br>frequency<br>[kHz]<br>Input<br>current [A]<br>*1<br>Inrush<br>current<br>protection|PCB/Pattern<br>Material<br>Single<br>sided||Double<br>sided|Series/Parallel<br>operation availability<br>Series<br>operation<br>Parallel<br>operation|| |TECS45F|Flyback converter<br>20 to 250<br>0.9<br>Thermistor|FR-4||Yes|Yes|No| |TECS65F|Flyback converter<br>20 to 800<br>1.25<br>Thermistor|FR-4||Multilayer|Yes|No| ## **Basic Characteristics Data** ~~Bee!~~ *1 The value of input current is at ACIN 100V and rated load. **TECS-8** www.cosel.co.jp/en/ June 10, 2024
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →