Image not available
Illustrative purposes only
TDR-960-48
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 960 W, 48 VDC, 20 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- No. of Outputs:1 Output; Output Power Max:960W; Output Voltage - Output 1:48V; Output Current - Output 1:20A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Outp
- SVHC: No SVHC (25-Jun-2025)
- Product Range: TDR-960 Series
- No. of Outputs: 1 Output
- Output Power Max: 960W
- Current, Output 4: -
- Input Voltage VAC: 340V AC to 550V AC
- Input Voltage AC Max: 550V
- Input Voltage AC Min: 340V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 20A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 253.12 € |
| Current stock | 10+ |
| Lead time | 30 days |
> 960W Three Phase Industrial DIN RAIL with PFC Function **TDR-960 series** M ~~WSS~~ ## ■ - ‧ - ‧ - ‧ ‧ - ‧ ‧ - ‧ - ‧ - ‧ - ‧ ‧ - ‧ |**MODEL**<br>~~=~~|**MODEL**<br>~~=~~|**TDR-960-24**<br>~~ee~~|**TDR-960-48**<br>~~®OCBCE~~| |---|---|---|---| |**OUTPUT**<br>**INPUT**<br>~~=~~<br>-|**DC VOLTAGE**<br>~~=~~|24V<br>~~ee~~|48V<br>~~®OCBCE~~<br>~~pT~~| ||**RATED CURRENT**<br>~~=~~|40A<br>~~ee~~|20A<br>~~®OCBCE~~<br>~~pT~~<br>~~pO~~| ||**CURRENT RANGE**<br>~~=~~|0 ~ 40A<br>~~ee~~|0 ~ 20A<br>~~®OCBCE~~<br>~~pO~~<br>~~Po~~| ||**RATED POWER**<br>~~=~~|960W<br>~~ee~~|960W<br>~~®OCBCE~~<br>~~Po~~<br>~~pO~~| ||**RIPPLE & NOISE (max.) Note.2**<br>~~=~~|180mVp-p<br>~~ee~~|250mVp-p<br>~~®OCBCE~~<br>~~pO~~<br>~~po~~| ||**VOLTAGE ADJ. RANGE**<br>~~=~~|24 ~ 28V<br>~~ee~~|48 ~ 55V<br>~~®OCBCE~~<br>~~po~~<br>~~po~~| ||**VOLTAGE TOLERANCE Note.3**<br>~~=~~|±1.0%<br>~~ee~~|±1.0%<br>~~®OCBCE~~<br>~~po~~<br>~~po~~| ||**LINE REGULATION**<br>~~=~~|±0.5%<br>~~ee~~|±0.5%<br>~~®OCBCE~~<br>~~po~~<br>~~pO~~| ||**LOAD REGULATION**<br>~~=~~|±1.0%<br>~~ee~~|±1.0%<br>~~®OCBCE~~<br>~~po~~| ||**SETUP, RISE TIME**<br>~~=~~|1000ms, 100ms/400VAC<br>800ms, 100ms/500VAC at full load<br>~~ee~~<br>~~®OCBCE~~<br>~~po~~<br>~~pT~~<br>~~pT~~|| ||**HOLD UP TIME (Typ.)**<br>~~=~~|12ms / 400VAC<br>at full load<br>14ms / 500VAC<br>~~ee~~<br>~~®OCBCE~~<br>~~pT~~|| ||**VOLTAGE RANGE**<br>**Note.4**<br>~~=~~<br>~~**PT**~~|Three-Phase 340 ~ 550VAC (Dual phase operation possible) 480 ~ 780VDC<br>~~ee~~<br>~~® OCBCE~~<br>~~pT~~<br>~~p~~~~**T**~~<br>~~**PT**~~|| ||**FREQUENCY RANGE**<br>~~**PT**~~|47 ~ 63Hz<br>~~p~~~~**T**~~<br>~~**PT**~~|| ||**POWER FACTOR(Typ.)**<br>~~**PT**~~|PF<br>0.88/400VAC<br>PF<br>0.86/500VAC at full load<br>≧<br>≧<br>~~p~~~~**T**~~<br>~~**PT**~~|| ||**EFFICIENCY(Typ.)**|94%<br>~~p~~~~**T**~~|94.5%<br>~~**T**~~<br>~~pe~~| ||**AC CURRENT (Typ.)**|2A/400VAC<br>1.4A/500VAC<br>~~p~~~~**T**~~<br>~~PT~~<br>~~PT~~|| ||**INRUSH CURRENT (Typ.)**|COLD START 60A<br>~~p~~~~**T**~~<br>~~PT~~|| ||**LEAKAGE CURRENT**|<3.5mA / 530VAC<br>~~p~~~~**T**~~<br>~~P~~|| |**FUNCTION**<br>**PROTECTION**|**OVERLOAD**|105 ~ 130% rated outputpower<br>~~Pd~~|| |||Protection type : Constant current limiting, unit will shut down after 3 sec. ,re-power on to recover<br>~~Pe~~|| ||**OVER VOLTAGE**|56 ~ 65V<br>29 ~ 33V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>~~Pe~~<br>~~pt~~<br>~~PT~~|| ||**OVER TEMPERATURE**|85<br>5<br>(TSW) detect on heatsink of power switch<br>℃± ℃<br>90<br>5<br>(TSW) detect on heatsink of power switch<br>℃± ℃<br>Protection type : Shut down o/p voltage, recovers automatically after temperature goes down<br>~~po~~<br>~~Re~~|| ||**DC OK REALY CONTACT RATINGS (max.)**|60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load<br>~~Re~~<br>PT|| ||**CURRENT SHARING**|Please refer to function manual<br>~~Re~~|| |**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>a|**WORKING TEMP.**<br>**Note.5**<br>~~Pt~~|-30 ~ +70℃(Refer to "DeratingCurve")<br>~~Re~~<br>~~Pd~~<br>~~Pt~~|| ||**WORKING HUMIDITY**<br>~~Pt~~|20 ~ 95% RH non-condensing<br>~~Pt~~|| ||**STORAGE TEMP., HUMIDITY**<br>~~Pt~~|-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>~~Pt~~<br>~~pT~~|| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50<br>~~pT~~<br>~~Pt~~|| ||**VIBRATION**<br>~~PR~~|Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>~~Pt~~<br>~~pT~~<br>~~PR~~|| ||**SAFETY STANDARDS**<br>~~PR~~|UL508 approved, IEC60950-1 CB approved bySIQ<br>~~PR~~|| ||**WITHSTAND VOLTAGE**<br>~~PR~~|I/P-O/P:3KVAC<br>I/P-FG:2KVAC<br>O/P-FG:0.5KVAC<br>O/P-DC OK:0.5KVAC<br>~~PR~~<br>~~PT~~|| ||**ISOLATION RESISTANCE**<br>~~PR~~|I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>~~PR~~<br>~~PT~~|| ||**EMC EMISSION**<br>~~PR~~|Compliance to EN55022(CISPR22),EN61204-3 Class B,EN61000-3-2,-3<br>~~PR~~<br>~~Pt~~|| ||**EMC IMMUNITY**<br>~~PR~~|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2(EN50082-2), EN61204-3, heavyindustrylevel, criteria A<br>~~PR~~<br>~~|~~|| |**OTHERS**|**MTBF**|59.4K hrs min.<br>MIL-HDBK-217F(25<br>)<br>℃<br>~~PT~~|| ||**DIMENSION**|110*125.2*150mm(W*H*D)<br>~~PT~~|| ||**PACKING**|2.47Kg ; 6pcs/15.8Kg/1.47CUFT<br>~~PT~~|| |**NOTE**|<br><br><br><br><br><br><br><br><br><br>℃||| - - _File Name:TDR-960-SPEC 2013-04-26_ **- TDR 960 series** ## 960W Three Phase Industrial DIN RAIL with PFC Function **==> picture [487 x 329] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No.214A Unit:mm<br>1234<br>125 .2<br>CN205<br>12 34<br>1<br>2<br>3<br>TB11 456<br>2 TB2<br>3<br>4<br>ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15<br>**----- End of picture text -----**<br> **==> picture [506 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal Pin No. Assignment (TB1) Terminal Pin No. Assignment (TB2) Control Pin (CN205) : DINKLE ECH250R-04P or equivalent<br>Pin No. Assignment Pin No. Assignment Pin No. Assignment Mating Housing Wire Diameter<br>12 AC/L3FG 1,2,34,5,6 DC OUTPUT +VDC OUTPUT -V 12 P-(Current Share)P+(Current Share) DINKLE ESC250V-04Por equivalent 0.081~0.517mm2<br>(Including in the (28~20AWG)<br>3 AC/L2 3,4 DC OK Relay Contact single package)<br>4 AC/L1<br>Block Diagram PFC fosc : 65KHz<br>PWM fosc : 60KHz<br>DC OK<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.C.P.<br>O.L.P.<br>DETECTION<br>FG<br>PWM CIRCUIT<br>PFC<br>CONTROL<br>CONTROL CURRENT SHARE CURRENT<br>SHARE<br>O.T.P.<br>O.V.P.<br>**----- End of picture text -----**<br> ## **DC OK Relay Contact** Contact Close PSU turns on / DC OK. Contact Open PSU turns off / DC Fail. Contact Ratings (max.) 30V/1A resistive load. _File Name:TDR-960-SPEC 2013-04-26_ **- TDR 960 series** ## 960W Three Phase Industrial DIN RAIL with PFC Function **==> picture [436 x 181] intentionally omitted <==** **----- Start of picture text -----**<br> Output derating VS input voltage<br>100<br>100 Three phase operation<br>90<br>80<br>80<br>60 70 Dual phase operation(L1 & L3)<br>60<br>40 Dual phase operation(L1 & L2 or L2 & L3)<br>50<br>20<br>40<br>-30 0 10 20 30 40 50 60 70 (VERTICAL) 340 360 380 400 450 500 550<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>**----- End of picture text -----**<br> ## **Derating Curve** ## **Function Manual** 1. Current sharing - (1) Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel). - (2) Difference of output voltages among parallel units should be less than 0.2V. - (3) The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9. - (4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications. - (5) The power supplies should be paralleled using short and large diameter wiring and then connected to the load. - (6) When in parallel operation, the minimum output load should be greater than 5% of total output load. - (Min. load >5% rated current per unit x number of unit) - (7) In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition. The other PSUs (slaves) may go into standby mode and their output LEDs & relays will not turn on. - (8) Some minor noise may be heard at light load condition under parallel operation. This is a normal phenomenon and the performance of the PSU will not be influenced. **==> picture [486 x 204] intentionally omitted <==** **----- Start of picture text -----**<br> LOAD<br>+V -V<br>P+ and P- lines<br>should be twisted in pairs<br>P+(pin2)<br>DCOK 4 DCOK 4 DC OK 4 P-(pin1) DC OK 4<br>DCOK 3 DCOK 3 DC OK 3 DC OK 3<br>P+ 2 P+ 2 P+ 2 P+ 2<br>P- 1 P- 1 P- 1 P- 1<br>CN205 CN205 CN205 CN205<br>+V -V +V -V +V -V +V -V<br>TB2 TB2 TB2 TB2<br>PSU PSU PSU PSU<br>**----- End of picture text -----**<br> _File Name:TDR-960-SPEC 2013-04-26_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →