Image not available
Illustrative purposes only
TCF80
INDUSTRIAL AND POWER
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON / PARTNER STOCK
- Product type: Industrial & Electrical Power Fuses
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 382.09 € |
| Current stock | 10+ |
| Lead time | 30 days |
Effective June 2016 Supersedes December 2015 **[BUSSMANN]** SERIES Technical Data 1160 ## Quik-Spec™ Coordination Panelboard 30 - 400A fusible panelboards ## **Contents** |**Contents**|| |---|---| |**Description**|**Page**| |Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 2-3|| |Enclosure types and voltages/systems . . . . . . . 4|Enclosure types and voltages/systems . . . . . . . 4| |Busing, main and feed-through lugs,<br>and main disconnects . . . . . . . . . . . . . . . . . . .|and main disconnects . . . . . . . . . . . . . . . . . . . 5-6| |Neutral and ground assemblies . . . . . . . . . . . . 7|Neutral and ground assemblies . . . . . . . . . . . . 7| |Surge Protective Device options . . . . . . . . . . . . 8|| |Typical wiring . . . . . . . . . . . . . . . . . . . . . . . . 9-10|| |Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11|| |Available panelboard configurations . . . . . . . 12|Available panelboard configurations . . . . . . . 12| |Replacement parts . . . . . . . . . . . . . . . . . . . 13-15|| |Fuse and disconnect performance data . . . . . 15|Fuse and disconnect performance data . . . . . 15| |CUBEFuse™ fuse specifications . . . . . . . . . . . 15|CUBEFuse™ fuse specifications . . . . . . . . . . . 15| Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data 1160 Effective June 2016 ## **Catalog symbol:** - QSCP ## **Description:** A configurable fusible panelboard for commercial/industrial branch or service entrance applications on systems up through 600Vac . The Quik-Spec Coordination Paneboard (QSCP) is especially designed to address the NEC[®] selective coordination requirements for emergency, legally required standby, critical operations data systems and Critical Operation Power Systems (COPS) per NEC[®] 700 .28, 701 .27, 645 .27 and 708 .54 . The QSCP is configured to order for the application . To confirm availability of options and constructions, contact your Bussmann series representative . ## **Ratings** - Volts: - 600Vac, 125Vdc ≤ 80A - Amps: - 30, 60, 100, 200, 225, 400A - SCCR: - See Panelboard Short-Circuit Current Ratings table ## **Agency information** - UL[®] 67 – standard for panelboards - UL 50/UL 50E – enclosures for electrical equipment - cULus to CSA Standard 22 .2, No . 29-M1989 – panelboards and enclosed panelboards - UL Listed, Class CTL panelboard - Uniform Building Code (UBC) and California Building Code (CBC) Seismic Qualified, and IBC[®] Approved ## **Main options** - Main Lug Only (MLO) - Non-fused main disconnect - Fused main disconnect ## **Branch disconnect options** ## **Average NEMA 1 QSCP weights*** - 18 circuit: 80 lbs (36kg) - 30 circuit: 100 lbs (45kg) - 42 circuit: 110 lbs (50kg) - Weight varies by options chosen . If needed, consult factory for exact weight . ## **CCPB horsepower ratings** **==> picture [264 x 36] intentionally omitted <==** **----- Start of picture text -----**<br> Amp Hp rating @ Vac<br>CCPB disconnect rating 120 240* 240** 480 600<br>CCPB-(Poles)-15CF 15 0 .5 1 .5 3 5 7 .5<br>**----- End of picture text -----**<br> ||CCPB-(Poles)-20CF<br>CCPB-(Poles)-30CF|20<br>30|0|75<br>1 5|2<br>3|3<br>5|7 5<br>15|10<br>10| |---|---|---|---|---|---|---|---|---| ||CCPB-(Poles)-40CF|40||2|3|7 5|20|10| ||CCPB-(Poles)-50CF|50||3|5|7 5|20|10| ||CCPB-(Poles)-60CF|60||3|7 5|7 5|20|10| ||CCPB-(Poles)-70CF†|70||3|7 5|15|30|40| ||CCPB-(Poles)-90CF†|90||5|10|20|50|40| ||CCPB-(Poles)-<br>100CF†|100||5|10|20|50|40| - Split-phase - ** Three-phase † Available for a bus rating of 225A or higher . ## **Panelboard Short-Circuit Current Ratings (SCCRs)** |**SCCR**|**AC main options**<br>**DC**| |---|---| ||**Main Lug**<br>**Only**<br>**(MLO)***<br>**70-200A**<br>**main disc.**<br>**no fuses* or**<br>**w/ Class J fuses**<br>**225-400A**<br>**main disc.**<br>**no fuses* or**<br>**w/ Class J fuses**<br>**CCP_CF**<br>**main disc.**<br>**(≤ 60A)****<br>**Main Lug**<br>**Only**<br>**(MLO)***| |High|200kA<br>200kA<br>100kA<br>200kA<br>100kA| |Std|50kA<br>50kA<br>50kA<br>50kA<br>20kA| - For panelboards with subfeed main lugs, or panelboards with optional feed-through lugs, Class J, T, or R fuses are required upstream - max amps = panel amps . - ** CUBEFuse disconnect . > • 1-, 2- and 3-pole 15, 20, 30, 40, 50, 60, 70, 90 and 100A ampacity rejecting branch disconnects (see table on page 3 for details) . Ampacity on 125Vdc panels ≤ 80A . Contact factory for details . ## **Branch circuit positions** - 18, 30 and 42 ## **Neutral options** - Unbonded and bonded 200A, 400A and 800A ## **Ground options** - Isolated and non-isolated ## **Enclosures:** - NEMA[®] 1 and NEMA 3R ## **Spare fuse compartment** - Six space spare fuse compartment standard on all models 2 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data1160 Effective June 2016 ## **Branch disconnects:** ## **Specifications** Box lug loadside terminal: - 15 - 60A **==> picture [259 x 129] intentionally omitted <==** **==> picture [225 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> 1-Pole 2-Pole 3-Pole<br>CCPB-1-_CF CCPB-2-_CF CCPB-3-_CF<br>**----- End of picture text -----**<br> - 18-6AWG single and dual rated (same size wire), solid or stranded – 75°C, Cu only - 4AWG single – 75°C, Cu only - 100A - 18-1AWG (1-45mm[2] ) single, solid or stranded – 75°C, Cu only and 6AWG dual 75°C, Cu only - Box lug loadside terminal torque: - 15 - 60A - 18-10AWG 20 Lb-In (2 .2 N•m) - 8-4AWG 35 Lb-In (3 .9 N•m) - 100A - 18-10AWG 25 Lb-In (1-6mm[2] /2 .82N•m - 8-1AWG 40 Lb-In (10-45mm[2] /4 .52 N•m) - 6AWG 45 Lb-In (16mm[2] /5 .08 N•m) **==> picture [537 x 36] intentionally omitted <==** **----- Start of picture text -----**<br> Typical installed fuse amp range<br>Fuse Max CCPB Time-delay Time-delay Fast-acting<br>CCPB* part number Poles amp range ampacity non-indicating fuses indicating fuses** non-indicating fuses<br>**----- End of picture text -----**<br> |CCPB-1-15CF|1||||TCF1RN, TCF3RN,||FCF1RN, FCF3RN,| |---|---|---|---|---|---|---|---| |CCPB-2-15CF|2|1|to 15|15|TCF6RN, TCF10RN,|TCF6, TCF10, TCF15|FCF6RN, FCF10RN,| |CCPB-3-15CF|3||||TCF15RN||FCF15RN| |CCPB-1-20CF|1||||||| |CCPB-2-20CF|2|1|to 20|20|TCF17-1/2RN, TCF20RN|TCF17-1/2, TCF20|FCF20| |CCPB-3-20CF|3||||||| |CCPB-1-30CF|1||||||| |CCPB-2-30CF|2|1|to 30|30|TCF25RN, TCF30RN|TCF25, TCF30|FCF25RN, FCF30RN| |CCPB-3-30CF|3||||||| |CCPB-1-40CF|1||||||| |CCPB-2-40CF|2|1|to 40|40|TCF35RN, TCF40RN|TCF35, TCF40|FCF35RN, FCF40RN| |CCPB-3-40CF|3||||||| |CCPB-1-50CF|1||||||| |CCPB-2-50CF|2|1|to 50|50|TCF45RN, TCF50RN|TCF45, TCF50|FCF45RN, FCF50RN| |CCPB-3-50CF|3||||||| |CCPB-1-60CF|1||||||| |CCPB-2-60CF|2|1|to 60|60|TCF60RN|TCF60|FCF60RN| |CCPB-3-60CF|3||||||| |CCPB-1-70CF|1†||||||| |CCPB-2-70CF|2†|1|to 70|70|TCF70RN|TCF70|FCF70RN| |CCPB-3-70CF|3†||||||| |CCPB-1-90CF|1†||||||| |CCPB-2-90CF|2†|1|to 90|90|TCF80RN, TCF90RN|TCF80, TCF90|FCF80RN, FCF90RN| |CCPB-3-90CF|3†||||||| |CCPB-1-100CF|1†||||||| |CCPB-2-100CF|2†|1|to100|100|TCF100RN|TCF100|FCF100RN| |CCPB-3-100CF|3†||||||| * CCPB disconnect can accept CUBEFuses with amp ratings less than or equal to the amp rating of the CCPB disconnect . ** Correct fit with CCPB disconnect requires indicating CUBEFuses with date code R38 or later . † Available for a bus rating of 225A or higher . 3 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data 1160 Effective June 2016 ## **Enclosure types:** ## **NEMA 1** - Flush or surface mount - Galvanized steel with removable end walls - blank or with knockouts to order - Box sizes: 20” W x 5 .75” D x 33”, 50”, 59”or 69” H (510 W x 145 D x 838, 1270, 1500 or 1753mm H) . Box can be rotated 180° to accommodate conduit feed - Enclosure and chassis mounting instructions are found in supplied literature - Chassis mounts directly onto studs in the enclosure - Trim finished with gray powder coat paint over phosphatized steel (ANSI 61) - Door and door-in-door configurations with locks - Door locks use key #2A1910-2 - Circuit directory card is located on the inside of the door - Trim screws are concealed ## **NEMA 3R** - Surface mount only - Finished with gray powder coat paint over phosphatized steel (ANSI 61) - Bottom feed only, no knockouts - Box sizes: 20” W x 7 .7” D x 34 .5”, 51 .5”, 60 .5” or 70 .5 H (510 W x 195 D x 876, 1310, 1535 or 1791mm H) - Enclosure and chassis mounting instructions are found in supplied literature - Chassis mounts directly onto studs in the enclosure - Gasketed door has vault handle with lock - Door locks use key #2A1910-1 - Circuit directory card is located on the inside of the door **==> picture [116 x 299] intentionally omitted <==** **==> picture [116 x 292] intentionally omitted <==** ## **AC and DC voltages and system types:** **==> picture [93 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> 3-phase, 4 wire, Delta<br>**----- End of picture text -----**<br> AC Voltages **==> picture [83 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> 1-phase, 2 wire<br>• 120V, 240V<br>1-phase, 3 wire<br>• 120/240V<br>**----- End of picture text -----**<br> **==> picture [87 x 74] intentionally omitted <==** **----- Start of picture text -----**<br> • 240/120V, 480/240V<br>A<br>B<br>N<br>C<br>**----- End of picture text -----**<br> ## 3-phase, 3 wire, Delta **==> picture [130 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> • 240V, 480V, 600V, 240V<br>Grounded B, 480V Grounded<br>B, 600V Grounded B<br>A<br>B<br>C<br>**----- End of picture text -----**<br> **==> picture [59 x 45] intentionally omitted <==** **==> picture [98 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> • 1-phase, 2 wire, Wye<br>**----- End of picture text -----**<br> **==> picture [230 x 255] intentionally omitted <==** **----- Start of picture text -----**<br> • 277V<br>A B 1-phase, 3 wire, Wye<br>• 208Y/120V, 480Y/277V<br>N<br>A B<br>C<br>N<br>1-phase, 2 wire, Delta<br>• 480V C<br>A<br>C B<br>1-phase, 3 wire, Delta<br>• 240/480V<br>A<br>N<br>C B<br>**----- End of picture text -----**<br> ## DC Applications ## 3-phase, 4 wire, Wye Panel bus configured for DC applications, MLO option only, CCPB 125Vdc ≤ 80A **==> picture [103 x 94] intentionally omitted <==** **----- Start of picture text -----**<br> • 208Y/120V, 480Y/277V,<br>600Y/347V<br>A<br>B<br>N<br>C<br>**----- End of picture text -----**<br> **==> picture [31 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> - +<br>**----- End of picture text -----**<br> **==> picture [73 x 64] intentionally omitted <==** 4 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data1160 Effective June 2016 ## **Busing:** The busing features tin-plated copper with sufficient cross section to meet UL 67 temperature rise requirements . Distributed 1- and 3-phase busing All CCPB branch disconnects can be mounted in any branch circuit position . **==> picture [261 x 134] intentionally omitted <==** **==> picture [183 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Single-phase Three-phase<br>**----- End of picture text -----**<br> ## **≤ 200A main lugs for 60/75° Cu/Al conductors:** **==> picture [129 x 72] intentionally omitted <==** ## **Main mechanical lugs** - ≤ 60A panels - 2-4AWG, torque 50 Lb-In (5 .6 N•m) - 6-10AWG, torque 40 Lb-In (4 .5 N•m) - 12-14AWG, torque 15 Lb-In (1 .7 N•m) - > 60 to 200A panels ## 225-400A main lugs for 60/75° Cu/Al conductors: **==> picture [129 x 308] intentionally omitted <==** ## **Main mechanical lugs** Main barrier cover open wire, 600kcmil-4AWG, torque 500 Lb-In (56 N•m) ## **Main sub-feed mechanical lugs** Main barrier cover open wire, 600kcmil-2AWG, torque 375 Lb-In (42 N•m) ## **Main compression (crimp) lugs*** Main barrier cover open wire, 600-250kcmil ## **Feed-through lugs** Compression, mechanical and double (sub-feed) lugs are all available as feed-through lugs except if Surge Protective Device (SPD) or loadside disconnect options are chosen . Lug ampacity ratings will be based upon panelboard ampacity rating . - 300kcmil-1AWG, torque 375 Lb-In (42 N•m) - 2-6AWG, torque 275 Lb-In (31 N•m) ## **225-400A loadside fused disconnect available on:** ## **Main sub-feed mechanical lugs** - ≤ 200A panels, 300kcmil - 6AWG, torque 275 Lb-In (31 N•m) Smaller lugs for ≤ 60 amp panels not available . ## **Main compression (crimp) lugs*** - ≤60A panels, 8AWG-1/0 - >60A panels, 300kcmil-4AWG **==> picture [129 x 160] intentionally omitted <==** - 18 and 30 branch position MLO - 18 branch position non-fused main disconnect - Switch amps: 200 - Mechanical lugs - 300kcmil-1AWG, torque 375 Lb-In (42 N•m) - 2-6AWG, torque 275 Lb-In (31 N•m) **==> picture [194 x 96] intentionally omitted <==** Fuse mounting torque: 40 Lb-In (4 .5 N•m) - Versa-Crimp[®] VC-6 crimp tool recommended for wire crimping . > ** Not available with Surge Protective Device (SPD) option . 5 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data 1160 Effective June 2016 ## 30-100A main disconnects for 75°C Cu conductors: ## **30-100A fused main disconnects (CCP), 1- and 3-phase** Not available with DC ratings - 18-10AWG single and dual, torque 20 Lb-In (2 .2 N•m) - 8-6AWG single and dual, torque 35 Lb-In (3 .9 N•m) - 4AWG single, torque 35 Lb-In (3 .9 N•m) **==> picture [223 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> Single-phase Three-phase<br>**----- End of picture text -----**<br> ## **70-200A main disconnects for 75°C Cu conductors:** ## **Fused main disconnect, 1- and 3-phase** ## **225-400A main disconnects for 75°C Cu conductors:** ## **Fused main disconnect, 1- and 3-phase** Not available with DC ratings - 600kcmil-2AWG, torque 375 Lb-In (42 N•m) - Fuse mounting torque: 40 Lb-In (4 .5 N•m) **==> picture [160 x 120] intentionally omitted <==** ## **Non-fused main disconnect, 1- and 3-phase** Not available with DC ratings - 600kcmil-2AWG, torque 375 Lb-In (42 N•m) Not available with DC ratings - 300kcmil-4AWG, torque 200 Lb-In (23 N•m) - Fuse mounting torque: 40 Lb-In (4 .5 N•m) **==> picture [154 x 101] intentionally omitted <==** **==> picture [150 x 107] intentionally omitted <==** ## **Non-fused main disconnect, 1- and 3-phase** Not available with DC ratings 300kcmil-4AWG, torque 200 Lb-In (23 N•m) **==> picture [146 x 111] intentionally omitted <==** 6 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data1160 Effective June 2016 ## **Neutral assemblies for 60/75°C Cu/Al conductors:** **==> picture [119 x 69] intentionally omitted <==** ## **200A Unbonded** - Main terminal 300kcmil-1AWG, torque 375 Lb-In (42 N•m) - Branch connections - see table - Bar material: aluminum **==> picture [123 x 66] intentionally omitted <==** ## **200A Bonded** - Main terminal 300kcmil-1AWG, torque 375 Lb-In (42 N•m) - Branch connections - see table - Bar material: aluminum **==> picture [121 x 71] intentionally omitted <==** ## **400A Unbonded** - Main terminal 600kcmil-4AWG, torque 500 Lb-In (56 N•m) - Branch connections - see table - Bar and lug material: aluminum **==> picture [121 x 67] intentionally omitted <==** ## **400A Bonded** - Main terminal 600kcmil-4AWG, torque 500 Lb-In (56 N•m) - Branch connections - see table - Bar and lug material: aluminum **==> picture [121 x 71] intentionally omitted <==** ## **800A Unbonded** - Main terminal (2) 600kcmil4AWG, torque 375 Lb-In (42 N•m) - Branch connections - see table - • Bar and lug material: aluminum **==> picture [121 x 66] intentionally omitted <==** ## **800A Bonded** - Main terminal (2)600kcmil4AWG, torque 375 Lb-In (42 N•m) - Branch connections - see table - Bar and lug material: aluminum ## **Ground assemblies for 60/75°C Cu/Al conductors:** ## **Isolated** **==> picture [131 x 100] intentionally omitted <==** Wire range and torque - see table Bar material: aluminum **==> picture [131 x 94] intentionally omitted <==** ## **Non-isolated** Wire range and torque - see table Bar material: aluminum ## **Neutral and Ground Assembly Installation:** To facilitate installation and wiring, both neutral and ground assemblies can be installed on either side of the chassis with the desired orientation using the supplied screws . Assembly torque 25 Lb-In (2 .8 N•m) ## **Ground and neutral bar wire connections:** |**Wire**<br>**AWG***<br>**Torque**<br>**Lb-In ( N•m)**|**Maximum number of wiresper openin**| |---|---| ||**Neutral**<br>**Ground**| |**Small opening**|| |14<br>25-35 (2 8-3 9)|2<br>2| |12<br>25-35 (2 8-3 9)|2<br>2| |10<br>25-35 (2 8-3 9)|2<br>2| |8<br>30-40 (3 4-4 5)|1<br>1| |6-4<br>35-40 (3 9-4 5)|1<br>1| |**Large opening**|| |14<br>25-35 (2 8-3 9)|3<br>3| |12<br>25-35 (2 8-3 9)|3<br>3| |10<br>35 (3 9)|3<br>3| |8<br>30-40 (3 4-4 5)|1<br>1| |6-4<br>35-40 (3 9-4 5)|1<br>1| |3-1/0<br>40-50 (4 5-5 6)|1<br>1| * 60/75°C, Cu/Al . 7 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data 1160 Effective June 2016 ## **Surge Protection Devices (SPDs):** ## **Features** - Heavy-duty zinc oxide varistors for high discharge capacity - Module locking system with module release button make module replacement easy without tools - Up to 200kA Short-Circuit Current Rating (SCCR) make higher assembly SCCR ratings possible - Optional remote signaling of all protection modules make status monitoring easy and accurate in any monitoring scheme - Vibration and shock tested according to EN 60068-2 to withstand harsh environments ## **Optional remote contact signaling** The remote contact signaling versions have a floating changeover contact for use as a break or make contact, according to circuit concept . ## **Factory installed BSPM_ three module SPD** Surge protection option precludes feed-through lug and loadside disconnect options . ## Available factory installed SPDs: **==> picture [209 x 36] intentionally omitted <==** **----- Start of picture text -----**<br> ™ We Optional remote<br>Form C contact<br>Local, visual sta- Pal signaling avail-<br>Casy tus indication able<br>**----- End of picture text -----**<br> ## **Description** Factory installed SPDs are the Bussmann[®] series 3-pole UL modular surge arresters for 240 and 480 3-phase Delta, and 120/208, 277/480 and 347/600Vac 3-phase Wye systems feature local, easyID™ visual indication and optional remote contact signaling . The unique module locking system fixes the protection module to the base . Modules can be easily replaced without tools by simply depressing the release buttons . Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module . |**System and voltage**<br>**Catalog number**<br>**Data sheet No.**| |---| |Single-phase,120/240<br>BSPM2240S3G<br>2150<br>Three-phase Wye,208/120<br>BSPM4208WYNG<br>2152<br>Three-phase Wye,480/277<br>BSPM4480WYNG<br>2152<br>Delta,480<br>BSPM3480DLG<br>2151<br>~~BC~~<br>~~Oo~~| See data sheets for specifications . ## **Optional field-installable SPDs** ## **Code requirement for Surge Protective Devices** 2014 NEC[®] 700 .8 requires a listed SPD to be installed in or on all emergency system switchboards and panelboards . All configurations of the QSCP intended for installation on an AC circuit can be ordered with an optional SPD to comply with this requirement . The factory installed three-module SPDs feature local, visual easyID™ status indication and can be specified with a remote Form C contact relay for integration into a monitoring system . The relay is rated to 250Vac/0 .5A and 250Vdc/0 .1A, 125Vdc/0 .2A, 75Vdc/0 .5A to accommodate many signaling needs . Although a Type 1 SPD may be retrofitted and added externally to meet the NEC[®] 2014 700 .8 or other surge suppression needs, it is recommended to factory order the SPD to assure correct specification for the system voltage and type, as well as proper installation . If an SPD is required after the QSCP is installed (for surface mount QSCPs only), Eaton recommends installing the externalmount Type 1 SurgePOD™ HEAVY DUTY (50kA Icapacity) or the Type 1 or Type 2 BSPD (from 120kA up to 400kA max surge current Imax surge current capacity) SPDs . Care should be taken to order the correct SurgePOD HEAVY DUTY catalog number or specify the correct BSPD (from the catalog number system) to match the electrical system type and voltage . ## **SPH50SP_** SurgePOD HEAVY DUTY is a Type 1 UL Listed SPD with a 50kA surge current capacity . Field installed device, does not ship with QSCP . Must be ordered separately . ## **BSPD_** BSPD includes UL Listed Type 1 or Type 2 SPDs (depending on the configuration ordered) with surge current capacities from 120kA to 400kA and are configurable for Wye (120/208, 277/480, 600) and Delta (240, 480, 600) systems . Field installed device, does not ship with QSCP . Must be ordered separately . 8 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data1160 Effective June 2016 ## **Typical QSCP wiring:** **==> picture [15 x 62] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> **==> picture [15 x 60] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> **==> picture [97 x 221] intentionally omitted <==** Single-phase, 2 wire main lug only **==> picture [104 x 234] intentionally omitted <==** Single-phase, 3 wire main lug only **==> picture [15 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> NEUTRAL<br>**----- End of picture text -----**<br> **==> picture [15 x 63] intentionally omitted <==** **----- Start of picture text -----**<br> NEUTRAL<br>**----- End of picture text -----**<br> **==> picture [97 x 222] intentionally omitted <==** **==> picture [15 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> NEUTRAL<br>**----- End of picture text -----**<br> **==> picture [15 x 62] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> Single-phase, 2 wire non-fused disconnect **==> picture [104 x 234] intentionally omitted <==** **==> picture [14 x 63] intentionally omitted <==** **----- Start of picture text -----**<br> NEUTRAL<br>**----- End of picture text -----**<br> **==> picture [15 x 60] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> Single-phase, 3 wire non-fused main disconnect **==> picture [14 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> **==> picture [13 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> **==> picture [93 x 221] intentionally omitted <==** **==> picture [15 x 62] intentionally omitted <==** **----- Start of picture text -----**<br> NEUTRAL<br>**----- End of picture text -----**<br> Single-phase, 2 wire fused disconnect **==> picture [97 x 234] intentionally omitted <==** **==> picture [14 x 60] intentionally omitted <==** **----- Start of picture text -----**<br> NEUTRAL<br>**----- End of picture text -----**<br> Single-phase, 3 wire fused main disconnect 9 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data 1160 Effective June 2016 ## **Typical QSCP wiring:** **==> picture [16 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> **==> picture [15 x 61] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> **==> picture [111 x 252] intentionally omitted <==** Three-phase, 3 wire main lug only **==> picture [106 x 240] intentionally omitted <==** **==> picture [15 x 64] intentionally omitted <==** **----- Start of picture text -----**<br> NEUTRAL<br>**----- End of picture text -----**<br> Three-phase, 4 wire main lug only **==> picture [112 x 255] intentionally omitted <==** **==> picture [16 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> Three-phase, 3 wire non-fused main disconnect **==> picture [107 x 242] intentionally omitted <==** **==> picture [15 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> NEUTRAL<br>**----- End of picture text -----**<br> **==> picture [15 x 63] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> Three-phase, 4 wire non-fused main disconnect **==> picture [106 x 254] intentionally omitted <==** **==> picture [15 x 61] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> Three-phase, 3 wire fused main disconnect **==> picture [107 x 256] intentionally omitted <==** **==> picture [15 x 62] intentionally omitted <==** **----- Start of picture text -----**<br> GROUND<br>**----- End of picture text -----**<br> **==> picture [15 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> NEUTRAL<br>**----- End of picture text -----**<br> Three-phase, 4 wire fused main disconnect 10 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data1160 Effective June 2016 ## **Enclosure dimensions - in:** ## **NEMA 1 enclosures and interior** **==> picture [487 x 633] intentionally omitted <==** **----- Start of picture text -----**<br> 0.3 Concentric KO21 (7/8, 1-1/8) 3.1 2.9 1.5 Concentric KO(1-3/4, 2, 2-1/2, 3, 3-5/8, 4-1/8)<br>1.1 2.2<br>7.4<br>0.5 Blank Endwall Knockout Endwall<br>DETAIL A Enclosures Available with 2 Blank, 2 Knockout, or 1 Each Endwall<br>Flush Mount Flush Mount<br>DW + 3.0 DW + 3.0<br>Surface Mount Surface Mount<br>11.3 DW DW<br>SH<br>A<br>Ground Door Lock Flush MountH + 3.0<br>Neutral<br>MH CH RH H Surface MountH<br>DH<br>Spare Fuse<br>Compartment<br>16.0 2.0 0.25 Mounting<br>20.0 D Hole Emboss (Door in Door Option Shown on Right)Front View<br>Box with Interior Side View of Box<br>NEMA 3R enclosures<br>0.2 0.5<br>Interior same as NEMA 1<br>SCALE 1 : 4DETAIL B Top End Wall (No Knockouts) 7.68<br>D<br>B<br>0.65<br>SH 2.0<br>0.6<br>2X<br>MH HC<br>H<br>Box Interior Same as NEMA 1<br>13.0<br>DW Side View<br>Front View<br>Enclosure<br>type Height H HC MH CH DH RH SH DW D<br>33 33 N/A 29 .0 26 28 .9 25 2 .0 20 5 .7<br>NEMA 1 50 50 N/A 43 .0 40 37 .9 39 3 .5 20 5 .7 Bottom End Wall (No Knockouts)<br>59 59 N/A 52 .0 49 46 .9 48 3 .5 20 5 .7<br>69 69 N/A 62 .0 59 56 .9 58 3 .5 20 5 .7<br>33 33 34 .5 35 .5 26 28 .9 25 2 .0 20 6 .3<br>50 50 51 .5 52 .5 40 37 .9 39 2 .0 20 6 .3<br>NEMA 3R<br>59 59 60 .5 61 .5 49 46 .9 48 2 .0 20 6 .3<br>69 69 70 .5 71 .5 59 56 .9 58 2 .0 20 6 .3<br>**----- End of picture text -----**<br> Other enclosures available . Consult factory for details . 11 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data 1160 Effective June 2016 ## **Available panelboard configurations:** Based upon enclosure height, panel amp rating and number of branch circuit positions . **==> picture [539 x 24] intentionally omitted <==** **----- Start of picture text -----**<br> Enclosure height Panel amps Branch positions Available configurations<br>- main lug only, with or without feed-through lugs<br>**----- End of picture text -----**<br> |**Enclosure height**|**Panel amps**|**Branch positions**<br>**Available configurations**<br>18<br>- main lug only, with or without feed-through lugs<br>| |---|---|---| |33”|30 - 200|- non-fused disconnect,no loadside options| |||30<br>- main lugonly,no loadside options| |50”|30 - 60|18<br>- 30 through 60A fused main disconnect, with or without feed-through lugs or<br>SPD| |||30<br>- 30 through 60A fused main disconnect, with or without feed-through lugs or<br>SPD| |||42<br>- 30 through 60A fused main disconnect, with or without feed-through lugs or<br>SPD| ||70 - 200|18<br>- 70 through 200A fused main disconnect, with or without feed-through lugs or<br>SPD| |||30<br>- 70 through 200A fused main disconnect,with or without feed-through lugs| ||30 - 200|18<br>- main lug only with SPD<br>- non-fused disconnect,with feed-through lugs or SPD| |||30<br>- main lug only, with feed-through lugs or SPD<br>- non-fused disconnect,with or without feed-through lugs| |||42<br>- main lug only, with or without feed-through lugs or SPD<br>- non-fused disconnect,with or without feed-through lugs| ||225 - 400A|18<br>- main lug only, with or without feed-through lugs or SPD<br>- non-fused disconnect,with or without feed-through lugs| |59”|70 - 200|30<br>- main lugonly,with or without feed-through lugs| |||30<br>- 70 through 200A fused main disconnect,with SPD| |||42<br>- 70 through 200A fused main disconnect, with or without feed-through lugs or<br>SPD| ||30 - 200|42<br>- non-fused disconnect with SPD| ||225 - 400A|18<br>- main lug only with loadside disconnect<br>- non-fused disconnect, with SPD<br>- 225 through 400A fused disconnect,with or without feed-through lugs or SPD| |||30<br>- main lug only, with SPD<br>- 225 through 400A fused disconnect,with no loadside options| |||42<br>- main lug only, with or without feed-through lugs or SPD<br>- non-fused disconnect,with no loadside options| |69”|225 - 400A|18<br>- non-fused disconnect,with loadside disconnect| |||30<br>- main lug only, with loadside disconnect<br>- 225 through 400A fused disconnect,with feed-through lugs or SPD| |||42<br>- non-fused disconnect, with or without feed-through lugs or SPD<br>- 225 through 400A fused main disconnect, with or without feed-through lugs or<br>SPD| 12 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data1160 Effective June 2016 ## Replacement parts: See list on following page for part numbers . **==> picture [413 x 641] intentionally omitted <==** **----- Start of picture text -----**<br> H<br>F<br>G<br>A<br>D<br>C<br>Selectable<br>knockout<br>endwall<br>B<br>E<br>Selectable<br>blank endwall<br>**----- End of picture text -----**<br> 13 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data 1160 Effective June 2016 ## **Replacement parts:** ## **A and B - main devices and feed-through lugs** * Also for use as feed-through lugs based upon panelboard ampacity rating 2A1909-1* Kit, compression lug 3-phase, 70-200A 2A1909-2* Kit, mechanical lug 3-phase, 70-200A 2A1909-3* Kit, double/sub-feed lug 3-phase, 30-200A 2A1909-4 Kit, main disconnect 70-200A 2A1909-5* Kit, compression lug 1-phase, 3 wire, 70-200A 2A1909-6* Kit, mechanical lug 1-phase, 3 wire, 70-200A 2A1909-7* Kit, double/sub-feed lug 1-phase, 3 wire, 30-200A 2A1909-8 Kit, main disconnect 30-60A 1-phase, 3 wire, 2A1909-9 Kit, main disconnect 30-60A 3-phase, - 2A1909-10* Kit, compression lug 3-phase, 30-60A - 2A1909-11* Kit, mechanical lug 3-phase, 30-60A - 2A1909-12* Kit, compression lug 1-phase, 3 wire, 30-60A 2A1909-13* Kit, mechanical lug 1-phase, 3 wire, 30-60A 2A1909-14* Kit, compression lug 1-phase, 2 wire, 70-200A 2A1909-15* Kit, mechanical lug 1-phase, 2 wire, 70-200A 2A1909-16* Kit, double/sub-feed lug 1-phase, 2 wire, 30-200A 2A1909-17* Kit, compression lug 1-phase, 2 wire, 30-60A 2A1909-18* Kit, mechanical lug 1-phase, 3 wire, 30-60A 2A1909-19 Kit, main disconnect 30-60A 1-phase, 2 wire, 2A1909-20* Kit, compression lug 3-phase, 225-400A 2A1909-21* Kit, mechanical lug 3-phase, 225-400A - 2A1909-22* Kit, double/sub-feed lug 3-phase, 225-400A 2A1909-23* Kit, compression lug 1-phase, 3 wire, 225-400A 2A1909-24* Kit, mechanical lug 1-phase, 3 wire, 225-400A 2A1909-25* Kit, double/sub-feed lug 1-phase, 3 wire, 225-400A 2A1909-26* Kit, compression lug 1-phase, 2 wire, 225-400A 2A1909-27* Kit, mechanical lug 1-phase, 2 wire, 225-400A 2A1909-28* Kit, double/sub-feed lug 1-phase, 2 wire, 225-400A 2A1909-29 Kit, main disconnect 225-400A ## **C - ground bars** 2A1907-1 Kit, non-isolated 2A1907-2 Kit, isolated ## **D - neutral bars** 2A1908-1 Kit, 200A unbonded 2A1908-2 Kit, 400A unbonded 2A1908-3 Kit, 200A bonded 2A1908-4 Kit, 400A bonded 2A2129-5 Kit, 800A unbonded 2A2129-6 Kit, 800A bonded ## **E - enclosures and boxes** XX in the p/n denotes endwall choices B = blank and K = knockout 2A1690-1XX NEMA 1 box, 50” tall 2A1690-2XX NEMA 1 box, 59” tall 2A1690-3XX NEMA 1 box, 69” tall 2A1690-4XX NEMA 1 box, 33” tall ## **F - enclosure doors** 2A1667-1 Door, surface for 50” box 2A1667-2 Door, surface for 59” box 2A1667-3 Door, flush for 50” box 2A1667-4 Door, flush for 59” box 2A1667-5 Door-in-door, surface for 50” box 2A1667-6 Door-in-door, surface for 59” box 2A1667-7 Door-in-door, flush for 50” box 2A1667-8 Door-in-door, flush for 59” box 2A1667-9 Door, surface for 69” box 2A1667-10 Door, flush for 69” box 2A1667-11 Door-in-door, surface for 69” box 2A1667-12 Door-in-door, flush for 69” box 2A1667-13 Door, surface for 33” box 2A1667-14 Door, flush for 33” box 2A1667-15 Door-in-door, surface for 33” box 2A1667-16 Door-in-door, flush for 33” box ## **G - dead fronts - branch enclosure** ## **For QSCP4 model number panelboards** - **2A1960-1 Kit, branch enclosure 18 position 2A1960-2 Kit, branch enclosure 30 position 2A1960-3 Kit, branch enclosure 42 position** ## **For QSCP model number panelboards** **2A1906-1 Kit, branch enclosure 18 positions 2A1906-2 Kit, branch enclosure 30 positions 2A1906-3 Kit, branch enclosure 42 positions** ## **H - keys and locks** - 2A1910-1 Kit, NEMA 3R replacement keys (2 keys) 2A1910-2 Kit, NEMA 1 door lock and 2 keys 2A1910-3 Kit, NEMA 3R door lock and 2 keys 2A1910-4 Kit, NEMA 1 replacement keys (2 keys) ## **Lockout/tagout devices** - 2A1912-1 Kit, lockout 70-400A main disconnect 2A1912-2 Kit, lockout 30-60A main disconnect 2A1912-3 Kit, branch lockout (3M Panelsafe) 18 position 2A1912-4 Kit, branch lockout (3M Panelsafe) 30 position 2A1912-5 Kit, branch lockout (3M Panelsafe) 42 position ## **Miscellaneous** - 2A1914 Kit, circuit directory card and sleeve 2A1915 Kit, circuit number and fuse rating labels 2A1917-1 Kit, panelboard hardware 2A1917-2 Kit, CCPB hardware (10 screws) 2A1918-1 ≤ 60A Kit, branch knockout covers (10 covers) 2A1918-2 70-100A Kit, branch knockout covers (10 covers) 2A1919 Kit, touch-up paint 2A1961-1 Kit, spare branch circuit fuse compartment, 1-100A 3A1072 Nameplate 2A1916-1 Kit, blank enclosure endwall (set of 2) 2A1916-2 Kit, knockout enclosure endwall (set of 2) 2A1649-1 NEMA 3R enclosure, 51 .5” tall 2A1649-2 NEMA 3R enclosure, 60 .5” tall 2A1649-3 NEMA 3R enclosure, 70 .5” tall 2A1649-4 NEMA 3R enclosure, 34 .5” tall 14 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data1160 Effective June 2016 CCPB disconnects and CUBEFuse replacement parts: **==> picture [172 x 165] intentionally omitted <==** **----- Start of picture text -----**<br> I<br>J<br>**----- End of picture text -----**<br> ## **Fuse and disconnect performance data:** For details and specifications, access the listed data sheets online at www .cooperbussmann .com/DatasheetsEle . **==> picture [263 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> Product Data sheet No.<br>**----- End of picture text -----**<br> |Low-Peak™ time-delayCUBEFuse™|9000| |---|---| |Fast-actingCUBEFuse|2147| |Low-Peak LPJ-_SPI Class J fuses|1063| |CCP main disconnect|1157| |CCPB branch disconnect|1161| ## **Additional references:** - Website (www cooperbussmann com/QSCP) - • Selective coordination (www cooperbussmann com/SelectiveCoordination) ## **CUBEFuse specifications:** **==> picture [264 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> Catalog symbols Description<br>**----- End of picture text -----**<br> ## **I - CCPB branch disconnects** **==> picture [264 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> Poles Ampacity Part number<br>**----- End of picture text -----**<br> |**Poles**<br>**Ampacity**|**Part number**| |---|---| |1<br>15A, 20A, 30A, 40A, 50A, 60A, 70A,<br>90A, 100A<br>2<br>3|<br>CCPB-1-(amp)CF| ||<br>CCPB-2-(amp)CF| ||CCPB-3-(amp)CF| ## **J - CUBEFuse™ fuses** **==> picture [264 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> Typical installed amp range<br>Non-indicating Indicating** Fast-acting<br>For CCPB* time-delay time-delay non-indicating<br>part number TCF(amps)RN TCF(amps) FCF(amps)RN<br>**----- End of picture text -----**<br> ||||TCF1RN,||FCF1RN,| |---|---|---|---|---|---| ||||TCF3RN,|TCF6,|FCF3RN,| |CCPB-(#|of|poles)-15CF|TCF6RN,|TCF10,|FCF6RN,| ||||TCF10RN,|TCF15|FCF10RN,| ||||TCF15RN||FCF15RN| |CCPB-(#|of|poles)-20CF|TCF17-1/2RN,<br>TCF20RN|TCF17-1/2,<br>TCF20|FCF20RN| |CCPB-(#|of|poles)-30CF|TCF25RN,<br>TCF30RN|TCF25,<br>TCF30|FCF25RN,<br>FCF30RN| |CCPB-(#|of|poles)-40CF|TCF35RN,<br>TCF40RN|TCF35,<br>TCF40|FCF35RN,<br>FCF40RN| |CCPB-(#|of|poles)-50CF|TCF45RN,<br>TCF50RN|TCF45,<br>TCF50|FCF45RN,<br>FCF50RN| |CCPB-(#|of|poles)-60CF|TCF60RN|TCF60|FCF60RN| |CCPB-(#|of|poles)-70CF†|TCF70RN|TCF70|FCF70RN| |CCPB-(#|of|poles)-90CF†|TCF80RN,<br>TCF90RN|TCF80,<br>TCF90|FCF80RN,<br>FCF90RN| |CCPB-(#<br>100CF†|of|Poles)-|TCF100RN|TCF100|FCF100RN| * CCPB disconnect can accept CUBEFuses with amp ratings less than or equal to the amp rating of the CCPB disconnect . - ** 1 and 3 amp indicating CUBEFuse not available . Correct fit with CCPB - disconnect requires indicating CUBEFuse with date code R38 or later . |TCF_|6-100A,time-delay,indicatingversion| |---|---| |TCF_RN|1-100A,time-delay,non-indicatingversion)| |FCF_RN|1-100A,fast-acting,non-indicatingversion)| ## **Description** The CUBEfuse is a finger-safe, dual-element, time-delay or fast-acting UL Class CF power fuse with Class J electrical performance characteristics . ## **Ratings** Volts: 600Vac/300Vdc (TCF_ and TCF_RN) 600Vac/dc (FCF_RN) - Amps: 1-100 time-delay (non-indicating version) 6-100 Time-delay (indicating version) - 1-100A, Fast-acting, (non-indicating version) - IR: 300kA RMS Sym . (UL) 200kA RMS . Sym (CSA) 100kA DC (UL and CSA), (time-delay) 50kA DC (UL and CSA), (fast-acting) ## **Agency information** - UL Listed, Guide JFHR, File E56412 (time-delay), File E4273 (fast-acting) - CSA Certified Class 1422- 02, File 53787 - CE compliance for the European Union low voltage directive ## **Watts loss at rated current** |**Time-delay**|**Watts loss**|**Fast-acting**|**Watts loss**| |---|---|---|---| |TCF30|3 99W|FCF30RN|5 45W| |TCF60|6 23W|FCF60RN|7 27W| |TCF100|9 51W||| - Available for a bus rating of 225A or higher . 15 Eaton.com/bussmannseries Quik-Spec Coordination Panelboard (QSCP) 30-400A fusible panelboards Technical Data 1160 Effective June 2016 The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton .com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton .com/bussmannseries © 2015 Eaton All Rights Reserved Printed in USA Publication No . 1160 - BU-SB15189 December 2015 Eaton, Bussmann, CUBEFuse, Low-Peak and Quik-Spec are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. NEC is a registered trademark of the National Fire Protection Association, Inc. NEMA is a registered trademark of the National Electrical Manufacturers Association. UBC is a registered trademark of the International Council of Building Officials. UL is a registered trademark of the Underwriters Laboratories, Inc. For Eaton’s Bussmann series product information, call **1-855-287-7626** or visit: **Eaton.com/bussmannseries** Follow us on social media to get the latest product and support information. Fi Eiin je}3:
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →