Image not available
Illustrative purposes only
TCF3RN
FUSE, 3A, 600V, TIME DELAY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON BUSSMANN
- Product type: Industrial & Electrical Power Fuses
- Product Range:CUBEFuse TCF Series; Fuse Current:3A; Voltage Rating VAC:600V; Voltage Rating VDC:300V; Fuse Size Metric:47.75mm x 19.05mm x 25.4mm; Fuse Size Imperial:1.88" x 0.75" x 1" 27R1565
- Fuse Current: 3A
- Product Range: CUBEFuse TCF Series
- Fuse Size Metric: 47.75mm x 19.05mm x 25.4mm
- Fuse Size Imperial: 1.88" x 0.75" x 1"
- Voltage Rating VAC: 600V
- Voltage Rating VDC: 300V
- Blow Characteristic: Time Delay
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 68.32 € |
| Current stock | 10+ |
| Lead time | 30 days |
Effective April 2017 Supersedes April 2016 **[BUSSMANN]** SERIES Technical Data 1161 ## CUBEFuse™ Compact Circuit Protector Base (CCPB) ## **Features and benefits:** **==> picture [36 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 2011/65/EU<br>**----- End of picture text -----**<br> - Uses finger-safe, current-limiting Class CF CUBEFuse with Class J performance available, time-delay or fast-acting versions from 1 to 100 amps* - Patented ampacity rejection feature helps prevent overfusing - High 200kA short-circuit current ratings - Disconnect rated to provide means for load isolation - All versions are full voltage rated at 600Vac - 125Vdc rated for 80A and below - UL 98 Listed and suitable for branch circuit disconnect - 1-, 2- and 3-pole versions are horsepower rated - Listed to UL and cULus - Open fuse indication light per pole - Additional open fuse indication can be provided by using the time-delay indicating CUBEFuse version - Built-in switch/fuse interlock prohibits fuse removal while energized - Permanent lockout/tagout provisions - Lock-On provision available when used in the Bussmann series Quik-Spec Coordination Panelboard (QSCP) - See data sheet 9000 for time-delay CUBEFuse and data sheet 2147 for fast-acting CUBEFuse specifications. ## **Product description:** The revolutionary Bussmann™ series Compact Circuit Protector Base (CCPB) with CUBEFuse™ is designed as a fused branch circuit disconnect switch for the Bussmann series Quik-Spec™ Coordination Panelboard. The CCPB with CUBEFuse simplifies selective coordination and lockout/tagout provisions allow for isolation of individual branch circuit loads for safe work practices. CUBEFuse Compact Circuit Protector Base (CCPB) for Quik–Spec™ Coordination Panelboards Technical Data 1161 Effective April 2017 ## **Specifications:** ## **Switch ampacity and rejection breaks** - 15A, 20A, 30A, 40A, 50A, 60A, 70A, 90A and 100A ## **Poles** - 1-, 2- and 3-pole versions ## **Volts** - 600Vac (or less) - 125Vdc (15, 20, 30, 40, 70 and 90 amp switches with ≤ 80A fuse) ## **Agency information** - UL 98 Listed, File E302370, Guide WHTY - cULus to CSA Standard 22.2 No. 4, File E302370, Guide WHTY7 - CE compliant - RoHS compliant ## **Terminals** Lineside bolt-on bus connector and torque - Bolt-mounted design into Quik-Spec Coordination Panelboard bus **==> picture [260 x 129] intentionally omitted <==** **==> picture [224 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> 1-Pole 2-Pole 3-pole<br>CCPB-1-_CF CCPB-2-_CF CCPB-3-_CF<br>**----- End of picture text -----**<br> - #10-32-UNC Hex flange Phillips screw; 25 Lb-In (2.8 N•m) Loadside box lug terminal and torque - 15-60A: - 18 to 10 AWG (1 to 6mm[2] ) single or dual rated (same size wire), solid or stranded – 75°C or higher - Cu only; 20 Lb-In (3.4 N•m) - 8 to 6 AWG (10 to 16mm[2] ) single or dual rated (same size wire), solid or stranded – 75°C or higher - Cu only; 35 Lb-In (5.8 N•m) - 4 AWG (25mm[2] ) single – 75°C or higher - Cu only; 35 Lb-In (5.8 N•m) - 100A: - 18 to 10 AWG (1 to 6mm[2] ) single, solid or stranded – 75°C or higher - Cu only; 25 Lb-In (2.82 N•m) - 8 to 1 AWG (10 to 45mm[2] ) single stranded – 75°C or higher - Cu only; 40 Lb-In (4.52 N•m) - 6 AWG (16mm[2] ) dual stranded (same size wire) – 75°C or higher Cu only; 45 Lb-In (5.08 N•m) ## **Loadside fork terminal** - Max. 30A suitable for use with #8-32UNC screw ## **Lockout/tagout** - 4mm shank lock ## **Local open fuse indication** - Light illumination requires closed circuit and minimum 90V operating voltage ## **Shipping weight** - 2.03 lbs per carton ## **Carton quantity** - 6 poles ## **Environmental data** **==> picture [65 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Lineside bolt-on<br>bus connector<br>**----- End of picture text -----**<br> **==> picture [138 x 292] intentionally omitted <==** **==> picture [94 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> Switch ON and OFF<br>symbols<br>Lockout/tagout provision<br>Switch handle<br>Local open fuse<br>indication light<br>CUBEFuse base<br>**----- End of picture text -----**<br> Storage and operating temperature -20°C to 75°C** - ** For fuse performance under or above 25°C, consult fuse performance derating charts. **==> picture [100 x 27] intentionally omitted <==** **----- Start of picture text -----**<br> Loadside Loadside<br>box lug fork<br>terminal terminal<br>**----- End of picture text -----**<br> 2 Eaton.com/bussmannseries CUBEFuse Compact Circuit Protector Base (CCPB) for Quik–Spec™ Coordination Panelboards Technical Data 1161 Effective April 201 ## **Catalog numbers:** **==> picture [536 x 35] intentionally omitted <==** **----- Start of picture text -----**<br> Accepts Typical installed fuse amp range Max.<br>CCPB Voltage CUBEFuse Time-delay Time-delay Fast-acting fuse Hp ratings<br>part numbers Poles rating amp range non-indicating indicating* non-indicating** amps [†] SCCR (Vac) [††]<br>**----- End of picture text -----**<br> |CCPB-1-15CF<br>1<br>600Vac,<br>125Vdc<br>1 to 15<br>TCF1RN,<br>TCF3RN,<br>TCF6RN,<br>TCF10RN,<br>TCF15RN<br>TCF6,<br>TCF10,<br>TCF15<br>FCF1RN,<br>FCF3RN,<br>FCF6RN,<br>FCF10RN,<br>FCF15RN<br>15A<br>200kA<br>AC<br>100kA<br>DC<br>CCPB-2-15CF<br>2<br>CCPB-3-15CF<br>3<br>600Vac|0.5Hp@120V| |---|---| ||1.5Hp@240V| ||3Hp@240V<br>5Hp@480V<br>7.5Hp@600V| |CCPB-1-20CF<br>1<br>600Vac,<br>125Vdc<br>1 to 20<br>TCF17-1/2RN,<br>TCF20RN<br>TCF17-1/2, TCF20<br>FCF20RN<br>20A<br>200kA<br>AC<br>100kA<br>DC<br>CCPB-2-20CF<br>2<br>CCPB-3-20CF<br>3<br>600Vac|0.75Hp@120V| ||2Hp@240V| ||3Hp@240V<br>7.5Hp@480V<br>10Hp@600V| |CCPB-1-30CF<br>1<br>600Vac,<br>125Vdc<br>1 to 30<br>TCF25RN,<br>TCF30RN<br>TCF25,<br>TCF30<br>FCF25RN,<br>FCF30RN<br>30A<br>200kA<br>AC<br>100kA<br>DC<br>CCPB-2-30CF<br>2<br>CCPB-3-30CF<br>3<br>600Vac|1.5Hp@120V| ||3Hp@240V| ||5Hp@240V<br>15Hp@480V<br>10Hp@600V| |CCPB-1-40CF<br>1<br>600Vac,<br>125Vdc<br>1 to 40<br>TCF35RN,<br>TCF40RN<br>TCF35,<br>TCF40<br>FCF35RN,<br>FCF40RN<br>40A<br>200kA<br>AC<br>100kA<br>DC<br>CCPB-2-40CF<br>2<br>CCPB-3-40CF<br>3<br>600Vac|2.0Hp@120V| ||3Hp@240V| ||7.5Hp@240V<br>20Hp@480V<br>10Hp@600V| |CCPB-1-50CF<br>1<br>600Vac,<br>125Vdc<br>1 to 50<br>TCF45RN,<br>TCF50RN<br>TCF45,<br>TCF50<br>FCF45RN,<br>FCF50RN<br>50A<br>200kA<br>AC<br>100kA<br>DC<br>CCPB-2-50CF<br>2<br>CCPB-3-50CF<br>3<br>600Vac|3.0Hp@120V| ||5Hp@240V| ||7.5Hp@240V<br>20Hp@480V<br>10Hp@600V| |CCPB-1-60CF<br>1<br>600Vac,<br>125Vdc<br>1 to 60<br>TCF60RN<br>TCF60<br>FCF60RN<br>60A<br>200kA<br>AC<br>100kA<br>DC<br>CCPB-2-60CF<br>2<br>CCPB-3-60CF<br>3<br>600Vac|3.0Hp@120V| ||7.5Hp@240V| ||7.5Hp@240V<br>20Hp@480V<br>10Hp@600V| |CCPB-1-70CF<br>1<br>600Vac,<br>125Vdc<br>1 to 70<br>TCF70RN<br>TCF70<br>FCF70RN<br>70A<br>200kA<br>AC<br>100kA<br>DC<br>CCPB-2-70CF<br>2<br>CCPB-3-70CF<br>3<br>600Vac|3.0Hp@120V| ||7.5Hp@240V| ||15Hp@240V<br>30Hp@480V<br>40Hp@600V| |CCPB-1-90CF<br>1<br>600Vac,<br>125Vdc<br>1 to 90<br>TCF90RN<br>TCF90<br>FCF80RN,<br>FCF90RN<br>90A<br>200kA<br>AC<br>100kA<br>DC<br>CCPB-2-90CF<br>2<br>CCPB-3-90CF<br>3<br>600Vac|5.0Hp@120V| ||10Hp@240V| ||20Hp@240V<br>50Hp@480V<br>40Hp@600V| |CCPB-1-100CF<br>1<br>600Vac,<br>125Vdc†††<br>1 to 100<br>TCF100RN<br>TCF100<br>FCF100RN<br>100A<br>200kA<br>AC<br>CCPB-2-100CF<br>2<br>CCPB-3-100CF<br>3<br>600Vac|5.0Hp@120V| ||10Hp@240V| ||20Hp@240V<br>50Hp@480V<br>40Hp@600V| * 1A and 3A indicating CUBEFuse not available. Correct fit with CCPB disconnect requires indicating CUBEFuse with date code R38 or later. ** Do not use UPS/Critical Application fast-acting FCF with motors. † Any fuse with an amp rating less than or equal to the max fuse rating may be used. E.g., TCF15 may be used with CCPB-1-20CF. †† Indiacting or non-indicating time-delay CUBEFuse only. ††† 125Vdc only applies up to 80A. 3 Eaton.com/bussmannseries CUBEFuse Compact Circuit Protector Base (CCPB) for Quik–Spec™ Coordination Panelboards Technical Data 1161 Effective April 2017 ## **Dimensions — in (mm):** ## **15-60A** **==> picture [259 x 174] intentionally omitted <==** **----- Start of picture text -----**<br> 1.0<br>(25.4)<br>2.0<br>(50.7)<br>3.0<br>(75.8)<br>Ø.2<br>(5.08)<br>**----- End of picture text -----**<br> **==> picture [251 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> 3.9<br>(99.4)<br>2.7 2.9<br>(69.1) (73.5)<br>0 .5<br>(12.9)<br>**----- End of picture text -----**<br> ## **70-100A** **==> picture [480 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> 5.3<br>(133.3)<br>3.4<br>2.7 (86.0)<br>(69.6)<br>0.03<br>(0.84)<br>0.54<br>(13 72)<br>**----- End of picture text -----**<br> **==> picture [243 x 149] intentionally omitted <==** **----- Start of picture text -----**<br> 1.0<br>(25.4)<br>2.0<br>(50.7)<br>3.0<br>(75.8)<br>Ø0.2<br>(5.08)<br>**----- End of picture text -----**<br> For details on the CCPB and its use in the Quik-Spec Coordination Panelboard, see data sheet 1160. 4 Eaton.com/bussmannseries CUBEFuse Compact Circuit Protector Base (CCPB) for Quik–Spec™ Coordination Panelboards Technical Data 1161 Effective April 201 ## **Motor sizing table:** ## **Low-Peak™ TCF_ and TCT_RN time-delay Class CF fuses** **==> picture [538 x 32] intentionally omitted <==** **----- Start of picture text -----**<br> Optimal Code Heavy Optimal Code Heavy<br>Motor Motor protection max start Motor Motor protection max start<br>Voltage size (Hp) FLA (amps) (amps) (amps) (amps) Voltage size (Hp) FLA (amps) (amps) (amps) (amps)<br>**----- End of picture text -----**<br> |115Vac, 1-Phase|0.167<br>4.4<br>10<br>10<br>10<br>0.25<br>5.8<br>10<br>15<br>15<br>0.333<br>7.2<br>15<br>15<br>15<br>0.5<br>9.8<br>15<br>20<br>20<br>0.75<br>13.8<br>25<br>25<br>30<br>1<br>16<br>25<br>30<br>35<br>1.5<br>20<br>30<br>35<br>45<br>2<br>24<br>40<br>45<br>50<br>3<br>34<br>50<br>60<br>N/A<br>5**<br>56<br>90<br>100<br>N/A<br>0.167<br>2.2<br>6<br>6<br>6<br>0.25<br>2.9<br>6<br>6<br>6<br>0.333<br>3.6<br>6<br>10<br>10<br>0.5<br>4.9<br>10<br>10<br>10<br>0.75<br>6.9<br>15<br>15<br>15<br>1<br>8<br>15<br>15<br>17.5<br>1.5<br>10<br>15<br>20<br>20<br>2<br>12<br>20<br>25<br>25<br>3<br>17<br>25<br>30<br>35<br>5<br>28<br>45<br>50<br>60<br>7.5<br>40<br>60<br>N/A<br>N/A<br>10**<br>50<br>80<br>90<br>N/A<br>0.5<br>2.5<br>6<br>6<br>6<br>0.75<br>3.7<br>6<br>10<br>10<br>1<br>4.8<br>10<br>10<br>10<br>1.5<br>6.9<br>15<br>15<br>15<br>2<br>7.8<br>15<br>15<br>17.5<br>3<br>11<br>17.5<br>20<br>20<br>5<br>17.5<br>30<br>35<br>35<br>7.5<br>25.3<br>40<br>45<br>50<br>20**<br>62.1<br>100<br>N/A<br>N/A<br>0.5<br>2.4<br>6<br>6<br>6<br>0.75<br>3.5<br>6<br>10<br>10<br>1<br>4.6<br>10<br>10<br>10<br>1.5<br>6.6<br>10<br>15<br>15<br>2<br>7.5<br>15<br>15<br>15<br>3<br>10.6<br>17.5<br>20<br>20<br>5<br>16.7<br>25<br>30<br>35<br>7.5<br>24.2<br>40<br>45<br>50<br>20**<br>59.4<br>90<br>N/A<br>N/A|230Vac, 3-Phase|0.5<br>2.2<br>6<br>6<br>6| |---|---|---|---| ||||0.75<br>3.2<br>6<br>6<br>6| ||||1<br>4.2<br>10<br>10<br>10| ||||1.5<br>6<br>10<br>15<br>15| ||||2<br>6.8<br>15<br>15<br>15| ||||3<br>9.6<br>15<br>20<br>20| ||||5<br>15.2<br>25<br>30<br>30| ||||7.5<br>22<br>35<br>40<br>45| ||||20**<br>54<br>90<br>100<br>N/A| |||460Vac, 3-Phase|0.5<br>1.1<br>3<br>3<br>3| |230Vac,1-Phase|||0.75<br>1.6<br>3<br>3<br>3| ||||1<br>2.1<br>6<br>6<br>6| ||||1.5<br>3<br>6<br>6<br>6| ||||2<br>3.4<br>6<br>6<br>6| ||||3<br>4.8<br>10<br>10<br>10| ||||5<br>7.6<br>15<br>15<br>15| ||||7.5<br>11<br>17.5<br>20<br>20| ||||10<br>14<br>25<br>25<br>30| ||||15<br>21<br>35<br>40<br>45| ||||20<br>27<br>40<br>50<br>60| ||||50**<br>65<br>100<br>N/A<br>N/A| |||575Vac, 3-Phase|0.5<br>0.9<br>3<br>3<br>3| |200Vac, 3-Phase|||0.75<br>1.3<br>3<br>3<br>3| ||||1<br>1.7<br>3<br>3<br>3| ||||1.5<br>2.4<br>6<br>6<br>6| ||||2<br>2.7<br>6<br>6<br>6| ||||3<br>3.9<br>6<br>10<br>10| ||||5<br>6.1<br>10<br>15<br>15| ||||7.5<br>9<br>15<br>20<br>20| ||||10<br>11<br>17.5<br>20<br>20| ||||40**<br>41<br>70<br>80<br>80| |208Vac, 3-Phase||**Note:**Use Code Max column for low to moderate reverse/jog/plug applications.<br>Heavy Start permitted only if Code Max does not allow motor start-up.<br>* Based on motor FLA from NEC®tables 430.248 and 430.250.|| ||||| 5 Eaton.com/bussmannseries CUBEFuse Compact Circuit Protector Base (CCPB) for Quik–Spec™ Coordination Panelboards **Technical Data 1161** Effective April 2017 The only controlled copy of this Data Sheet is the electronic read-only version located on the Eaton Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. ## **Eaton** 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries © 2017 Eaton All Rights Reserved Printed in USA Publication No. 1161 - BU-SB15190 April 2017 Eaton, Bussmann, Quik-Spec and CUBEfuse are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group. NEC is a registered trademark of the National Fire Protection Association, Inc. NEMA is a registered trademark of the National Electrical Manufacturers Association. UL is a registered trademark of the Underwriters Laboratories, Inc. Follow us on social media to get the latest product and support information.
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →