- Manufacturer: EATON BUSSMANN
- Product type: Industrial & Electrical Power Fuses
- CUBEFUSE 150 AMP
- SVHC: To Be Advised
- Fuse Current: 150A
- Product Range: CUBEFuse TCF Series
- Fuse Size Metric: 66mm x 34mm x 74mm
- Fuse Size Imperial: 2.6" x 1.34" x 2.9"
- Voltage Rating VAC: 600V
- Voltage Rating VDC: 300V
- Blow Characteristic: Time Delay
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 272.98 € |
| Current stock | 10+ |
| Lead time | 30 days |
Effective March 2019 Supersedes January 2019 **[BUSSMANN]** SERIES Technical Data 9000 ## UL Class CF branch circuit time-delay CUBEFuse **==> picture [52 x 38] intentionally omitted <==** **----- Start of picture text -----**<br> 2011/65/EU<br><><br>**----- End of picture text -----**<br> ## **Electrical characteristics** - 10 seconds minimum operating time at 500% rated current ## **Agency information** - UL Listed Class CF fuse: Guide JDDZ, File E4273 (up to 400 A) - CSA[®] Certified fuse: Class 1422-02, File 053787_C_000 (up to 100 A) - CE (100 A and below) ## **Catalog symbols** - RoHS compliant ## **Watts loss at rated current** - TCF_ (indicating fuse, 6-400 A) - TCF_RN (non-indicating fuse, 1-400 A) ## **Description** The Bussmann™ series Low-Peak™ CUBEFuse™ is a UL[®] Class CF current-limiting, dual-element, time-delay branch circuit fuse with Class J electrical performance. Available in indicating and non-indicating versions, this finger-safe fuse has a very compact, space-saving size and is easily applied using the CUBEFuse holder (TCFH_N), UL 98 Compact Circuit Protector switch (CCP2-_CF) or Compact Circuit Protector Base (CCP2B up to 100 A) used in the Quik-Spec™ Coordination Panelboard). ## **Ratings** - Volts - 600 Vac - 300 Vdc - Amps - 6-400 A (indicating) - 1-400 A (non-indicating) - Interrupting rating - 300 kA RMS Sym. (Up to 100 A UL) - 200 kA RMS Sym. (110 to 400 A UL) - 200 kA RMS Sym. (Up to 100 A CSA) - 100 kA DC (Up to 400 A UL and up to 100 A CSA) |**Fuse amps**|**Fuse amps**<br>**Watts**| |---|---| |30|3.99| |60|6.23| |100|9.51| |200|18.6| |225|17.6| |400|35.2| ## **Operating and storage temperature range** - -40 to 80°C (-40°F to 176°F) |**Catalog numbers (amps)**|**Catalog numbers (amps)**||| |---|---|---|---| |**Indicating CUBEFuse**|||| |TCF6|TCF35|TCF90|TCF225| |TCF10|TCF40|TCF100|TCF250| |TCF15|TCF45|TCF110|TCF300| |TCF17-1/2|TCF50|TCF125|TCF350| |TCF20|TCF60|TCF150|TCF400| |TCF25|TCF70|TCF175|| |TCF30|TCF80|TCF200|| |**Non-Indicating CUBEFuse**|||| |TCF1RN|TCF25RN|TCF70RN|TCF175RN| |TCF3RN|TCF30RN|TCF80RN|TCF200RN| |TCF6RN|TCF35RN|TCF90RN|TCF225RN| |TCF10RN|TCF40RN|TCF100RN|TCF250RN| |TCF15RN|TCF45RN|TCF110RN|TCF300RN| |TCF17-1/2RN|TCF50RN|TCF125RN|TCF350RN| |TCF20RN|TCF60RN|TCF150RN|TCF400RN| UL Class CF branch circuit time-delay CUBEFuse Technical Data 9000 Effective March 2019 ## **Features** ## **Dimensions — in (mm)** - Smallest installed footprint of any UL Class CC, J, or R fuse solution - Easy application using CUBEFuse holders (TCFH_N), UL 98 Compact Circuit Protector (CCP2) switches and Compact Circuit Protector Base (CCP2B up to 100 A). See data sheet 9007 for details on the CUBEFuse holder, 10801 for details on the CCP2-_ CF switch and 1161 for the CCP2B. - Holders and switches have an amp rating rejection feature to help prevent overfusing; 30, 60 and 100 A switches and holders will hold any CUBEFuse up to its rating, 200 and 400 A switches and 200, 225 and 400 A holders will hold any CUBEFuse 110 A and above up to its rating - UL Class CF with Class J time-delay electrical performance - Available in indicating and non-indicating versions - The indicating version features local easyID™ open fuse technology for faster troubleshooting and reduced downtime - Faster response to damaging faults helps reduce destructive thermal and magnetic forces - True dual-element fuse construction with a minimum 10 seconds time-delay at 500% of rating - Long time-delay minimizes nuisance openings caused by temporary overloads and transient surges - Up to 300 kA interrupting rating safely interrupts virtually any fault - Robust cycling and inrush current withstand - Low let-through currents under fault conditions - Provides Type 2 “No Damage” protection for IEC motor starters when properly sized - Easy selective coordination with any other Bussmann series Low-Peak Class CC, J, L or RK1 fuse with simple 2:1 amp ratio between upstream and downstream fuses - Finger-safe status depends on final, installed application, and will require using accessory shrouds for 110 to 400 A ratings. **==> picture [241 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Up to 30 A 35 to 60 A 70 to 100 A 110-225 A 250-400 A<br>**----- End of picture text -----**<br> **==> picture [263 x 207] intentionally omitted <==** **----- Start of picture text -----**<br> B<br>C<br>A it !<br>Up to 100 A<br>Tol<br>| E | D<br>B C<br>A<br>110 to 400 A D<br>[- i L= E<br>**----- End of picture text -----**<br> |**Fuse**<br>**amps**||**A**|**B**|**C**|**D**|**E**| |---|---|---|---|---|---|---| |1-15|||||0.23 (6)|| |17-1/2<br>20||1.88 (48)|0.75 (19)|1.0 (25)|0.27 (7)|| |25-30<br>35-40|||||0.31 (8)<br>0.36 (9)|0.67 (17)| |45-50||2.13 (54)||1.13 (29)|0.44 (11)|| |60<br>70|||1.0 (25)|||| ||||||0.49 (12)|| |80-90||3.01 (76)||1.26 (32)||0.64 (16)| |100|||||0.57 (14)|| |110||||||0.51 (13)| |125||||||0.51 (13)| |150||||||0.51 (13)| |||3.62 (92)|2.9 (74)|1.34 (34)|1.02 (26)|| |175||||||0.57 (14.5)| |200||||||0.57 (14.5)| |225||||||0.63 (16)| |250||||||0.73 (18.5)| |300||||||0.79 (20)| |~~a~~|~~a~~|4.25 (108)|3.46 (88)|1.69 (43)|1.47 (36)|| |350||||||0.86 (21.5)| |400||||||0.86 (21.5)| **Carton quantity and weight** |**Amp range**<br>**Carton qty.**<br>**Weight per carton lb (kg)**<br>~~a~~|**Amp range**<br>**Carton qty.**<br>**Weight per carton lb (kg)**<br>~~a~~|**Amp range**<br>**Carton qty.**<br>**Weight per carton lb (kg)**<br>~~a~~| |---|---|---| |Up to 30|12|1.39 (0.63)| |35-60|12|1.42 (0.64)| |70-100|6|1.74 (0.79)| |110 to 225|1|0.71 (0.32)| |250 to 400|1|1.23 (0.56)| 2 Eaton.com/bussmannseries UL Class CF branch circuit time-delay CUBEFuse Technical Data 9000 Effective March 2019 ## **Up to 100 A time-current characteristics — average melt** ## **110 to 400 A time-current characteristics — average melt** **==> picture [532 x 571] intentionally omitted <==** **----- Start of picture text -----**<br> <x<br>1000 = 1000 ——— ee<br>FAH A A EHH 9 HV} —$_ a ApHE<br>YrBnenVT TIVITYy A\ TTT h—¥pCOASAAN EINTTEEETT<br>100 PN EAL E ]NIN Vi GBAA AAW\GRA N AOUU I IIT San OOTU7) 100 SANAATell<br>RA es Oe eee ee NS<br>PACT AAA Ao oo a ee eS<br>PT ATTN NT ON INATAT AAW TORT TTT TTT pT A NNN ON TT TT TT<br>ANATTKN \ \<br>80 oL LL NUTININAWANINIEEAAATI 10 ee| a |NAee<br>oO Eee EAR7 eeSS NSee NSSSee GEN OWN ES GE A EE CS OS<br>Be CAAA es<br>ui2=FTN HTeea\ eeCVU PE 1 Trrrell|| |[| [|| TT| TRITE NEl VVVA\YVWV VWVY EELTF EEL<br>SS === eeeeeeSee Seere e e ——S—See eee ee ee es | ee ts WW<br>PETrT TTT ATT Ta ETT rTee| | | _ |[[[ITN2=\VVEVSSS| SeECCT<br>CAT \|<br>a URI ROLTT TRTCLOLVAGL GOO 0.1 TT> FATT AITVT<br>Se ee ee See ee oe ee eS te eee ———_—_—_——<br>a a A HA ——_} —}—_ }_¢ + + Y@£__} | 1<br>PE eA A<br>rT TTT VT TATA VT TT SD RD a GO Ok On WOOO<br>| a ee<br>ot~LLLUT 2 VAI 8 VAAN S ETT 8 0.01 Pt TELE EAA V<br>a<br>=) a<br>CURRENT IN AMPS 2 CURRENT IN AMPS<br>Up to 100 A current let-through curves 110 to 400 A current let-through curves<br>100.000 77aB B<br>100,000<br>See eeoo 4Sce eye<br>a a ee ee2ee ee<br>@ a a| 400A<br>250A<br>= ee ee) ee ee AL LLU oe 225A<br>200A<br>7 VW = 100A ee ke 110A<br>§ wooo ANIME | UV | I ee 10,000 PUTTIN [ear<br>2 FE ar _——<br>308 =a ee<br>= Fe se 2 en A]<br>a eee eee a tt<br>1 , 000<br>5 polAT ARE<br>=<|re27 100av=Cae—| | |i fo} | Ti Q | tii ° Tffo) 100A P| 7H LTTEP| P|FTP|<br>= S 3 St 8 PROSPECTIVE SHORT CIRCUIT CURRENT<br>- fo} fo) roy SYMMETRICAL RMS AMPS<br>110A 200A 225A 250A 400A<br>TIME IN SECONDS<br>100 1,000 10,000<br>INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS<br>100 1,000 10,000 100,000<br>**----- End of picture text -----**<br> 3 Eaton.com/bussmannseries UL Class CF branch circuit time-delay CUBEFuse Effective March 2019 ## Technical Data 9000 **Motor sizing table (from NEC Tables 430.248 and 430.250)** ## **Bussmann series TCF Low-Peak time-delay Class CF fuses** **==> picture [538 x 33] intentionally omitted <==** **----- Start of picture text -----**<br> NEC Heavy NEC Heavy<br>Motor size Motor FLA Min code max start* Motor size Motor FLA Min code max start*<br>Voltage (Hp) (amps) (amps) (amps) (amps) Voltage (Hp) (amps) (amps) (amps) (amps)<br>**----- End of picture text -----**<br> ||0.167|4.4|10|10|10||0.5|2.4|6|6|6| |---|---|---|---|---|---|---|---|---|---|---|---| ||0.25|5.8|10|15|15||0.75|3.5|6|10|10| ||0.333|7.2|15|15|15||1|4.6|10|10|10| ||0.5|9.8|15|20|20||1.5|6.6|10|15|15| ||0.75|13.8|25|25|30||2|7.5|15|15|15| |**115 Vac,**|1|16|25|30|35||3|10.6|17.5|20|20| |**1-phase**|1.5|20|30|35|45|**208 Vac,**|5|16.7|25|30|35| ||2|24|40|45|50|**3-phase**|7.5|24.2|40|45|50| ||3|34|50|60|70||20**|59.4|90|110|125| ||5**|56|90|100|125||25|74.8|125|150|150| ||7.5|80|125|150|175||30|88|150|175|175| ||10|100|150|175|225||40|114|175|200|250| ||0.167|2.2|6|6|6||50|143|225|300|300| ||0.25|2.9|6|6|6||60|169|300|300|350| ||0.333|3.6|6|10|10||0.5|2.2|6|6|6| ||0.5|4.9|10|10|10||0.75|3.2|6|6|6| ||0.75|6.9|15|15|15||1|4.2|10|10|10| |**230 Vac,**|1|8|15|15|17.5||1.5|6|10|15|15| |**1-phase**|1.5|10|15|20|20||2|6.8|15|15|15| ||2|12|20|25|25||3|9.6|15|20|20| ||3|17|25|30|35||5|15.2|25|30|30| ||5|28|45|50|60|**230 Vac,**<br>**3-phase**|7.5|22|35|40|45| ||7.5|40|60|70|90||20**|54|90|100|110| ||10**|50|80|90|110||25|68|110|125|150| ||0.5|2.5|6|6|6||30|80|125|150|175| ||0.75|3.7|6|10|10||40|104|175|200|225| ||1|4.8|10|10|10||50|130|200|250|250| ||1.5|6.9|15|15|15||60|154|250|300|300| ||2|7.8|15|15|17.5||75|192|300|350|400| ||3|11|17.5|20|20||0.5|1.1|3|3|3| |**200 Vac,**|5|17.5|30|35|35||0.75|1.6|3|3|3| |**3-phase**|7.5|25.3|40|45|50||1|2.1|6|6|6| ||20**|62.1|100|110|125||1.5|3|6|6|6| ||25|78.2|125|150|175||2|3.4|6|6|6| ||30|92|150|175|200||3|4.8|10|10|10| ||40|120|200|225|250||5|7.6|15|15|15| ||50|150|225|300|300||7.5|11|17.5|20|20| |60<br>177<br>**Note:**Use NEC code max column|||300<br>350<br>350<br>for low to moderate reverse/jog/|||**460 Vac,**<br>**3-phase**|10<br>15|14<br>21|25<br>35|25<br>40|30<br>45| |plug applications.|||||||20|27|40|50|60| |* Heavy Start permitted only if NEC code max does not allow motor start-up.<br>** If equipment terminations are rated for 60°C conductors only, the 60°C|||||||50**|65|100|125|125| |conductor ampacities must be utilized and therefore||||larger conductor sizes or|||60|77|125|150|150| |conduit sizes may be required.|||||||75|96|150|175|200| ||||||||100|124|200|225|250| ||||||||125|156|250|300|350| ||||||||150|180|300|350|400| **Note:** Use NEC code max column for low to moderate reverse/jog/ plug applications. - Heavy Start permitted only if NEC code max does not allow motor start-up. ** If equipment terminations are rated for 60°C conductors only, the 60°C conductor ampacities must be utilized and therefore larger conductor sizes or conduit sizes may be required. 4 Eaton.com/bussmannseries UL Class CF branch circuit time-delay CUBEFuse Technical Data 9000 Effective March 2019 ## **Motor sizing table (from NEC Tables 430.248 and 430.250)** ## **Bussmann series TCF Low-Peak time-delay Class CF fuses** **==> picture [264 x 33] intentionally omitted <==** **----- Start of picture text -----**<br> NEC Heavy<br>Motor size Motor FLA Min code max start*<br>Voltage (Hp) (amps) (amps) (amps) (amps)<br>**----- End of picture text -----**<br> |**Voltage**|**Motor size**<br>**(Hp)**<br>**Motor FLA**<br>**(amps)**<br>**Min**<br>**(amps)**<br>**NEC**<br>**code max**<br>**(amps)**<br>**Heavy**<br>**start***<br>**(amps)**<br><br><br><br><br>| |---|---| |**575 Vac,**<br>**3-phase**|0.5<br>0.9<br>3<br>3<br>3| ||0.75<br>1.3<br>3<br>3<br>3| ||1<br>1.7<br>3<br>3<br>3| ||1.5<br>2.4<br>6<br>6<br>6| ||2<br>2.7<br>6<br>6<br>6| ||3<br>3.9<br>6<br>10<br>10| ||5<br>6.1<br>10<br>15<br>15| ||7.5<br>9<br>15<br>20<br>20| ||10<br>11<br>17.5<br>20<br>20| ||40**<br>41<br>70<br>80<br>80| ||50<br>52<br>80<br>100<br>110| ||60<br>62<br>100<br>110<br>125| ||75<br>77<br>125<br>150<br>150| ||100<br>99<br>150<br>175<br>200| ||125<br>125<br>200<br>225<br>250| ||150<br>144<br>225<br>300<br>300| ||200<br>192<br>300<br>350<br>400| **Note:** Use NEC code max column for low to moderate reverse/jog/ plug applications. - Heavy Start permitted only if NEC code max does not allow motor start-up. - ** If equipment terminations are rated for 60°C conductors only, the 60°C conductor ampacities must be utilized and therefore larger conductor sizes or conduit sizes may be required. 5 Eaton.com/bussmannseries UL Class CF branch circuit time-delay CUBEFuse Effective March 2019 ## Technical Data 9000 ## **CUBEFuse (cat. no. TCFH_N) holders** The CUBEFuse is used in holders that can be dovetail together for the smallest footprint possible of any Class J fuse solution (see data sheet no. 9007 for details). Finger-safe DIN-Rail or panel mount holders up to 100 A. - 30 A holder accepts any CUBEFuse up to 30 A. - 60 amp holder accepts any CUBEFuse up to 60 A. - 100 amp holder accepts any CUBEFuse up to 100 A. Panel mount holders from 200 to 400 A. - 200 A holder accepts any CUBEFuse from 110 to 200 A - 225 A* holder accepts any CUBEFuse from 110 to 225 A - 400 A holder accepts any CUBEFuse from 110 to 400 A Finger-safe installation achievable for three ganged holders and lug kits with shroud - 200 A and 225 A holders share the same overall dimensions, but the 200 A holder will reject a 225 A fuse. ## **30, 60 and 100 A Compact Circuit Protector (cat. no.CCP2_CF) switches** ## **200 and 400 A Compact Circuit Protector (cat. no. CCP2-CF) switches** These panel mounted 1-, 2- and 3-pole switches are UL 98 horsepower rated disconnects. Each CCP2 will accept a fuse amp rating equal to or less than its rating (e.g., a 200 A CCP will accept any CUBEFuse from 110 to 200 A). Complete installation requires installing various lugs to meet the application requirement. Accessories include side or front rotary operators and auxiliary contacts (see data sheet no. 10801 for details). ## **Compact Circuit Protector Base (cat. no. CCP2B)** These 1-, 2- and 3-pole switches are UL 98 horsepower rated branch circuit disconnects. Primarily used in the Quik-Spec Coordination Panelboard, they’re available in ratings up to 100 A. The CCP2B has amp rejection breaks that prevent installing any CUBEFuse amp rating greater than that of the switch. These coincide with standard conductor ampacities to help prevent overfusing and are available at 15, 20, 30, 40, 50, 60, 70, 90 and 100 amps for all 1-, 2- and 3-pole switches. These DIN-Rail mounted 1-, 2- and 3-pole switches are UL 98 horsepower rated disconnects available with front or side rotary operators. Each CCP2 will accept a fuse amp rating equal to or less than its rating (e.g., a 60 A CCP will accept any CUBEFuse up to 60 A). Accessories include multi-wire lug kits with shrouds, auxiliary contacts and PLC fuse monitor (see data sheet no. 10801 for details). The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. ## **Eaton** 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries © 2019 Eaton All Rights Reserved Printed in USA Publication No. 9000 – BU-SB18086 March 2019 Eaton, Bussmann, CUBEFuse, Low-Peak, easyID and Quik-Spec are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group NEC is a registered trademark of the National Fire Protection Association UL is a registered trademark of the Underwriters Laboratories, Inc. For Eaton’s Bussmann series product information, call **1-855-287-7626** or visit: **Eaton.com/bussmannseries** Follow us on social media to get the latest product and support information.
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →