TA35-CKDWF050C0
Thermal Circuit Breaker, TA35, 5 A, 3 Pole, 415 VAC, Panel
- Manufacturer: SCHURTER
- Product type: Thermal Circuit Breakers
- Product Range:TA35 Series; Current Rating:5A; No. of Poles:3 Pole; Voltage Rating V DC:-; Voltage Rating VAC:415VAC; Circuit Breaker Mounting:Panel; SVHC:No SVHC (27-Jun-2018); Approval Bodies:CC
- No. of Poles: 3 Pole
- Product Range: TA35
- Current Rating: 5A
- Voltage Rating VAC: 415VAC
- Voltage Rating VDC: -
- Circuit Breaker Mounting: Panel
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 17.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Thermal (T- and TA-Line)** www.schurter.com /PG17_20 TA35 Rocker 3Pole Circuit Breaker for Equipment thermal, Rocker actuation, 3 poles ## **Description** - Thermal circuit breaker - 3-pole - Snap-in version - Positively trip-free release - Different rocker colours - High configurability - Wide current range ## **Standards** - Approval Reference Type: TA35 ## **Applications** - Power tools - Industrial appliances - Equipment for construction - Cleaning equipment - Commercial and household kitchen appliances ## **Weblinks** pdf datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, DistributorStock-Check, Detailed request for product, Product News - IEC 60934 - UL 1077 - CSA C22.2 No. 235 - GB 17701 |**Technical Data**|| |---|---| |Rated Voltage AC|415 Y / 240 V; 50/60 Hz| |Rated current range AC|0.05-12 A| |Conditional short circuit ca-|0.05...12 A: 2 kA @ 415 VAC| |pacity|| |Degree of Protection|from front side IP 40 acc. to IEC 60529| |Dielectric Strength|50 Hz: > 2.5 kV| ||Impulse 1.2/50μs: > 4 kV| |Insulation resistance|500 VDC > 100 MΩ| |Endurance typical|mechanical: 50'000 switching cycles| |AC: 1 x Ir, cosφ0.6:<br>50'000 switching cycles|| |DC: 1 x Ir, L/R = 2 - 3 ms:|| ||50'000 switching cycles| |Overload|IEC: min. 40 trips| |---|---| ||@ 6 x Ir, cosφ0.6| |UL / CSA: min. 50 trips|| ||@ 1.5 x Ir, cosφ0.75| |Ambient temperature|-30°C to 60°C| |Vibration Resistance|± 0.75 mm @ 10 - 60 Hz| ||acc. to IEC 60068-2-6, test Tc| ||10 G @ 60 - 500 Hz| ||acc. to IEC 60068-2-6, test Tc| |Shock Resistance|30 G / 18 ms| ||acc. to IEC 60068-2-27, test Ea| |Tripping Type|Thermal| |Actuation Type|Rocker| |Weight|43.0-45.0 g| Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in General Product Information ## **Dimension** **==> picture [315 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> 36 40.5<br>34 31.9 37.5 +0.2 0<br>+0.3<br>L<br>ae od<br>iO 4 Panel 1.0 − 4.0 mm<br>Pt I HE<br>21.3 2.3 11 11 6.1<br>33.8 34.5<br>= A<br>6.3 x 0.8 mm 37.4<br>1.7<br>7.2<br>+0.2 0<br>33.5 34<br>44.1<br>LINE<br>10.5 10.6<br>**----- End of picture text -----**<br> Circuit Breakers **1** **Thermal (T- and TA-Line)** www.schurter.com /PG17_20 TA35 Rocker 3Pole ## **Diagrams** **==> picture [100 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> 3-pole, 3 bimetal, illuminated<br>**----- End of picture text -----**<br> **==> picture [115 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> 3-pole, 3 bimetal, non illuminated<br>**----- End of picture text -----**<br> **==> picture [422 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> 1) 1)<br>P1 P2 P3 P1 P2 P3<br>4 5 6 4 5 6<br>2) 2)<br>1) Line, 2) Load 1) Line, 2) Load<br>Codepos AAA = CD1 Codepos AAA = CKD, CLD<br>**----- End of picture text -----**<br> The keys / codepos are listed in the key table of the basic function for selection. ## **Approvals** **==> picture [427 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> Approval Rated current Rated voltage AC Rated voltage DC<br>UL 1077 0.05...12 A 415 Y/ 240 V -<br>CSA C22.2 0.05...12 A 415 Y/ 240 V -<br>235<br>IEC 60934 0.05...12 A 415 Y/ 240 V -<br>GB 17701 0.05...12 A 415 Y/ 240 V -<br>**----- End of picture text -----**<br> ## **Typical internal resistance** **==> picture [172 x 284] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Current [A] Internal Resistance [ Ω ]<br>0.05 200.000<br>0.1 70.000<br>0.5 2.750<br>1.0 0.720<br>1.5 0.340<br>2.0 0.187<br>2.5 0.115<br>2.8 0.089<br>3.0 0.059<br>4.0 0.059<br>5.0 0.044<br>6.0 0.028<br>7.0 0.0142<br>8.0 0.0142<br>10.0 0.0109<br>12.0 0.0086<br>13.0 0.0072<br>14.0 0.0072<br>15.0 0.0056<br>16.0 0.0056<br>18.0 0.0052<br>20.0 0.0052<br>**----- End of picture text -----**<br> TA35 Rocker 3-poles max. 12 A Circuit Breakers **2** **Thermal (T- and TA-Line)** www.schurter.com /PG17_20 TA35 Rocker 3Pole ## **Effect of ambient temperature** The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: **==> picture [314 x 99] intentionally omitted <==** **----- Start of picture text -----**<br> Ambient temperature [°C] Correction factor<br>-30 0.76<br>-20 0.81<br>0 0.90<br>+23 1.00<br>+40 1.06<br>+50 1.10<br>+60 1.14<br>**----- End of picture text -----**<br> Example: Rated current = 5 A; Environmental temperature = 50 °C; --> Correction factor = 1.10; Resulting current = 5.2 A --> Fount to next higher rated current: 6 A ## **Time-Current-Curves** **==> picture [442 x 268] intentionally omitted <==** **----- Start of picture text -----**<br> [min ] [sec ] [min ] [sec ]<br>10'000 10'000<br>TA35 <3A (TC-1, TC-2) TA35 >3-20A (TC-1, TC-2)<br>1, 2 pole (3 pole<br>60 3 pole 60 1, 2, 3 polemax. 12A)<br>30 2`000 30 2`000<br>20 20<br>1`000 1`000<br>10 10<br>500 500<br>5 5<br>200 200<br>100 100<br>1 1<br>50 50<br>20 20<br>10 10<br>5 5<br>2 2<br>1 1<br>0,5 0,5<br>0,3 0,3<br>0,2 0,2<br>0,1 0,1<br>1,05 1,35 2 3 4 5 8 10 1,05 1,35 2 3 4 5 8 10<br>Multiple of Rated Current In Multiple of Rated Current In<br>Reference Temperature +23° Reference Temperature +23°<br>Time in Seconds Time in Seconds<br>**----- End of picture text -----**<br> ## **Config. Code** ## ~~TA35~~ ~~**|** -~~ ~~**|** CBD~~ ~~**|** B~~ ~~**|** F~~ ~~**|** 120~~ ~~**|** C0~~ ~~**|** -~~ ~~**|** CZMXX~~ ~~**|**~~ The characters are placeholders for the correspondingly keys of selections from the key tables. **==> picture [515 x 155] intentionally omitted <==** **----- Start of picture text -----**<br> TA35 | - | CBD | B | F | 120 | C0 | - | CZMXX | = Basic function Rocker colour Configuration<br>key<br>Basic function Configuration Red transparent 3<br>key<br>Green transparent 4<br>3-pole, 3 bimetal, illuminated 415 V CD1<br>Orange transparent 6<br>3-pole, 3 bimetal, without illumination CKD<br>Blue transparent 7<br>3-pole, 3 bimetal, momentary switch, without illumination CLD<br>Black B<br>Green G<br>TA35 | - | CBD | B | F | 120 | C0 | - | CZMXX | = Rocker colour Red R<br>White W<br>Rocker colour Configuration<br>key Orange X<br>Yellow Y<br>Clear transparent 1<br>**----- End of picture text -----**<br> Circuit Breakers **3** **Thermal (T- and TA-Line)** www.schurter.com /PG17_20 TA35 Rocker 3Pole ## ~~TA35~~ ~~**|** -~~ ~~**|** CBD~~ ~~**|** B~~ ~~**| F |** 120~~ ~~**|** C0~~ ~~**|** -~~ ~~**|** CZMXX~~ ~~**|**~~ **= Legend** **==> picture [251 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> Legend Configuration<br>key<br>embossed F<br>white printed H<br>black printed K<br>white printed L<br>black printed M<br>I 0<br>ON OFF<br>ON OFF<br>I 0<br>I 0<br>**----- End of picture text -----**<br> ## ~~TA35~~ ~~**|** -~~ ~~**|** CBD~~ ~~**|** B~~ ~~**|** F~~ ~~**| 120 |** C0~~ ~~**|** -~~ ~~**|** CZMXX~~ ~~**|**~~ **= Rated current** **==> picture [251 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> Rated current Configuration<br>key<br>without thermal overload protection / temporarily without VDE approval C00<br>0.05 A Z05<br>0.1 A J01<br>0.2 A J02<br>0.3 A J03<br>0.4 A J04<br>0.5 A J05<br>0.8 A J08<br>1.0 A J10<br>1.2 A J12<br>Other rated currents on request<br>**----- End of picture text -----**<br> **==> picture [251 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> Rated current Configuration<br>key<br>1.5 A J15<br>2.0 A J20<br>2.5 A J25<br>3.0 A 030<br>3.5 A 035<br>4.0 A 040<br>5.0 A 050<br>6.0 A 060<br>7.0 A 070<br>8.0 A 080<br>10.0 A 100<br>12.0 A 120<br>Other rated currents on request<br>**----- End of picture text -----**<br> ## ~~TA35~~ ~~**|** -~~ ~~**|** CBD~~ ~~**|** B~~ ~~**|** F~~ ~~**|** 120~~ ~~**| C0 |** -~~ ~~**|** CZMXX~~ ~~**|**~~ **= Reserve** **==> picture [251 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> Reserve Configuration<br>key<br>reserve C0<br>TA35 | - | CBD | B | F | 120 | C0 | - | CZMXX | = Accessories<br>Factory mounted accessories Configuration<br>key<br>Without cover<br>For subsequent fitting accessories see:<br>http://www.schurter.com//accessory_cbe<br>**----- End of picture text -----**<br> ## **All Variants** **==> picture [519 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> Basic function Rocker colour Legend Rated current Accessories Config. Code Order Number<br>3-pole, 3 bimetal, without illumination Black white printed 2.5 A Without cover TA35-CKDBHJ25C0 4435.0229<br>3-pole, 3 bimetal, without illumination White embossed 3.0 A Without cover TA35-CKDWF030C0 4435.0025<br>3-pole, 3 bimetal, without illumination Black white printed 4.0 A Without cover TA35-CKDBH040C0 4435.0232<br>3-pole, 3 bimetal, without illumination White embossed 5.0 A Without cover TA35-CKDWF050C0 4435.0044<br>3-pole, 3 bimetal, without illumination Black white printed 5.0 A Without cover TA35-CKDBH050C0 4435.0048<br>3-pole, 3 bimetal, without illumination Black white printed 6.0 A Without cover TA35-CKDBH060C0 4435.0233<br>3-pole, 3 bimetal, without illumination White embossed 10.0 A Without cover TA35-CKDWF100C0 4435.0050<br>3-pole, 3 bimetal, without illumination Black white printed 10.0 A Without cover TA35-CKDBH100C0 4435.0235 █<br>3-pole, 3 bimetal, without illumination White embossed 12.0 A Without cover TA35-CKDWF120C0 4435.0017<br>3-pole, 3 bimetal, illuminated 415 V Red transparent white printed 12.0 A Without cover TA35-CD13L120C0 4435.0414<br>**----- End of picture text -----**<br> ## █ Most Popular. Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER **Packaging Unit** 10 Pcs Circuit Breakers **4** **Thermal (T- and TA-Line)** www.schurter.com /PG17_20 TA35 Rocker 3Pole ## **Accessories** ## **Description** TA35 Accessories Screw-on collar with cover, IP65 The specifications, descriptions and illustrations indicated in this document are based on current ~~information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.~~ Circuit Breakers **5**
Updated at April 27, 2026
SCHURTER is a globally recognized innovator and manufacturer of high-quality electronic components, specializing in products that ensure a safe and clean supply of power. With a strong reputation in the electronics and PCB assembly industries, the company delivers reliable solutions engineered to protect critical circuits, streamline device operation, and optimize electrical performance across diverse applications. The core of our SCHURTER portfolio revolves around comprehensive circuit protection. We carry an extensive selection of standard and resettable fuses, accompanied by robust fuse holders, to safeguard sensitive electronics against overcurrent conditions. Furthermore, our offering features high-performance thermal circuit breakers and associated accessories, providing dependable protection and rapid reset capabilities for demanding industrial and commercial environments. Beyond fundamental circuit protection, SCHURTER excels in electromagnetic compatibility (EMC) and RFI suppression technologies. Our range includes precision-engineered power line filters and common mode chokes designed to mitigate electromagnetic interference and ensure signal integrity. Accompanied by specialized components such as AC/DC LED power supplies, SCHURTER provides the meticulous engineering and durability necessary for modern, high-reliability electronic design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →