TA35-CBTWF050C0
Thermal Circuit Breaker, TA35, 5 A, 2 Pole, 32 V, 240 V, Panel
- Manufacturer: SCHURTER
- Product type: Thermal Circuit Breakers
- Product Range:TA35 Series; Current Rating:5A; No. of Poles:2 Pole; Voltage Rating V DC:32VDC; Voltage Rating VAC:240VAC; Circuit Breaker Mounting:Panel; SVHC:No SVHC (27-Jun-2018); Approval Bodie
- SVHC: No SVHC (14-Jun-2023)
- No. of Poles: 2 Pole
- Product Range: TA35
- Current Rating: 5A
- Voltage Rating VAC: 240V
- Voltage Rating VDC: 32V
- Circuit Breaker Mounting: Panel
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 14.07 € |
| Current stock | 10+ |
| Lead time | 30 days |
**circuit breakers** ## **Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole** |TA35 1-pole||TA35 2-pole||TA35 3-pole|| |---|---|---|---|---|---| |||||ALL|| |**Description**|||**Applications**||| |– Thermal circuit breaker 1-, 2- or 3-pole|||– Power tools||| |– Supplementary protector for general industrial use|||– Industrial equipment||| |– Positively trip-free release|||– Equipment for building construction||| |– Snap-in mounting|||– Medical equipment||| |– Version with illuminated rocker|||– Cleaning equipment||| |– Different rocker colours|||– Power generators||| |– Protection cover for IP65|||– Commercial and household kitchen appliances||| |**Standards**|||**Weblinks**||| |– IEC 60934|||Approvals: http://www.schurter.com/approvals||| |– UL 1077|||RoHS: http://www.schurter.com/rohs||| |– CSA C22.2 235|||||| |– GB 17701|||||| |**TeChniCAl DATA**|||||| |Rated voltage Ue<br>Rated current In<br>Conditional short<br>circuit Inc<br>Degree of protection<br>Dielectric strength<br>Insulation resistance<br>Endurance (typical)|1-pole<br>2-pole<br>3-pole<br>1- / 2-pole<br>3-pole<br>1- / 2-pole, AC 240 V<br>3-pole, AC 400 V<br>Accessible range<br>Terminal side<br>AC 250 V / 50 Hz<br>DC 500 V<br>Mechanical<br>AC: 1 x In, cos phi 0.6<br>DC: 1 x In, L/R = 2…3ms|AC 240 V / 50/60 Hz<br>DC 32 V<br>AC 240 V / 50/60 Hz<br>DC 60 V<br>AC 415 Y/240 V / 50/60 Hz<br>0.05 – 20 A<br>0.05 – 12 A<br>0.05…20 A: 1000 A, SC (C1)<br>0.05…12 A: 1000 A<br>IP 40<br>IP 00<br>1500 V<br>Impulse 2000 V<br>> 100 MOhm<br>50’000 cycles<br>30’000 cycles<br>30’000 cycles|Overload<br>Admissible ambient<br>air temperature<br>Resistance to vibration<br>Shock resistance<br>Type of tripping<br>Weight|IEC 60934<br>UL 1077<br>IEC 60068-2-6, Test Tc<br>IEC 60068-2-27, Test Ea <br>1-pole<br>2-pole<br>3-pole|min. 40 cycles @ 6 x In,<br>cos phi 0.6<br>min. 50 cycles @ 1.5 x In,<br>cos phi 0.75 (OLØ)<br>–10 °C to +55 °C<br>10…60 Hz: ±0.75 mm<br>60…500 Hz: 10 G<br> 30 G / 18 ms<br>Thermal positively trip free<br>19 g<br>32 g<br>45 g| ## **Description** - Thermal circuit breaker 1-, 2- or 3-pole - Supplementary protector for general industrial use - Positively trip-free release - Snap-in mounting - Version with illuminated rocker - Different rocker colours - Protection cover for IP65 ## **Standards** - IEC 60934 - UL 1077 - CSA C22.2 235 - GB 17701 ## **TeChniCAl DATA** **2** **circuit breakers** **TA35** ~~**www.schurter.com/pg17_18_19**~~ ## **Tripping ChArACTeriSTiCS** **==> picture [443 x 293] intentionally omitted <==** **----- Start of picture text -----**<br> [ min ] [ sec ] [ min ] [ sec ]<br>10'000 10'000<br>Type p TA35 Type TA35<br>Rated current <3A (TC1) Rated current ≥3–20A (TC1)<br>60 — 1, 2 pole 60 | IE (3 polemax. 12A)<br>3 pole<br>30 > 2`000 J 30 > 2`000 Je 1,2,3 pole<br>20 Ambient temp. +23 °C 20 Ambient temp. +23 °C<br>- 1`000 TT - 1`000 JAE<br>10 10<br>500 500<br>5 - Ta 5 e s<br>200 200<br>- Wok | otTLL = wok} tL<br>100 100<br>- UAT - MAE ET<br>1 1<br>50 50<br>— FXO — INERT<br>20 20<br>HEN PSS LET WNOENC LEE<br>10 10<br>PUT SOARS INE SEE<br>5 5<br>TOAST NEST<br>2 2<br>Hf] SNES SINGS<br>1 1<br>t 0,5 ee 0,5 pit TT NET<br>0,3 i t 0,3 TOPs<br>0,2 ee ee eee 0,2 Hoi} | ot PE EES<br>nel i el<br>0,1 0,1<br>1,05 (Sc 1,35 2 ee 3 ee 4 5 8 10 1,05 a 1,35 2 3 4 5 8 10<br>Multiple of rated current [ x In ] Multiple of rated current [ x In ]<br>Tripping time Tripping time<br>**----- End of picture text -----**<br> The above tripping characteristics apply to symmetrical overloads on all poles on the TA35 only. At asymmetric overloads on multi-pole types, the tripping characteristic will change. – If a 2-pole type TA35 is loaded at one pole only, the tripping current will be shifted by factor **1.05** . – If a 3-pole type TA35 is loaded at one pole only, the tripping current will be shifted by factor **1.10** . To meet the above tripping characteristic at asymmetric overloads on multi-pole types, the value of the rated current of the CBE has to be multiplied by the factor mentioned above. ## **effect of ambient temperature** The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for lower or higher ambient temperature, use a correction factor from the table below. |**Ambient**<br>**Correction factor**| |---| |**temperature [°C]**| |–10<br>0.87<br>–5<br>0.89<br>0<br>0.90<br>+23<br>1.00<br>+30<br>1.04<br>+40<br>1.10<br>+55<br>1.22| ## **example:** Rated current at +23 °C 5.0 A Ambient temperature +40 °C Correction factor 1.10 Chosen rated current at +40 °C ambient temperature: **5 A x 1.10 = 5.5 A** **3** **circuit breakers** **circuit breakers** **Standard rated currents and typical internal resistance** |**Code**|**In**|**Ri [Ohm]**| |---|---|---| |J01<br>J05<br>J10<br>J15<br>J20<br>J25<br>J28<br>030<br>040<br>050<br>060<br>070<br>080<br>100<br>120<br>140<br>150<br>160<br>180|0.1<br>0.5<br>1.0<br>1.5<br>2.0<br>2.5<br>2.8<br>3.0<br>4.0<br>5.0<br>6.0<br>7.0<br>8.0<br>10.0<br>12.0<br>14.0<br>15.0<br>16.0<br>18.0|70.000<br>2.750<br>0.720<br>0.340<br>0.190<br>0.115<br>0.090<br>0.058<br>0.044<br>0.028<br>0.021<br>0.016<br>0.010<br>0.010<br>0.0068<br>0.0052<br>0.0048<br>0.0048<br>0.0048| |200|20.0|0.0048| unprotected poles (without bimetal) 0.0022 ## **ApprovAlS** |**# of poles**|**Rated currents**|**Rated voltage AC**|**Rated voltage DC**| |---|---|---|---| |UL<br>UL 1077<br>1 *<br>2<br>3<br>UL<br>CSA C22.2 235<br>1 *<br>2<br>3<br>VDE<br>IEC 60934<br>1 *<br>2<br>3<br>CQC<br>GB 17701<br>1 *<br>2 *<br>3 *|0.05…20 A<br>0.05…20 A<br>0.05…12 A<br>0.05…20 A<br>0.05…20 A<br>0.05…12 A<br>0.05…20 A<br>0.05…20 A<br>0.05…12 A<br>0.05…20 A<br>0.05…20 A<br>0.05…12 A|240 V<br>240 V<br>415 Y/240 V<br>240 V<br>240 V<br>415 Y/240 V<br>240 V<br>240 V<br>415 Y/240 V<br>240 V<br>240 V<br>415 Y/240 V|32 V<br>60 V<br>—<br>32 V<br>60 V<br>—<br>32 V<br>60 V<br>—<br>32 V<br>60 V<br>—| * Approvals pending Actual information about approvals can be found on: www.schurter.com/approvals. **circuit breakers** **TA35** ~~**www.schurter.com/pg17_18_19**~~ ## **orDer CoDe** **==> picture [498 x 672] intentionally omitted <==** **----- Start of picture text -----**<br> 1-pole 2-pole 3-pole<br>P1 P1 P1 P2 P1 P2 P1 P2 P1 P2 P3 P1 P2 P3<br>sedi od l i gt el i a l ll e l lA a g ed dl<br>i 4 Micelles 4 4 5 7 8 9 4 5 6<br>7 7 8 8<br>Switch without CFC CFT CBC CBT CBD CKC CKD<br>Illumination<br>Switch illuminated 415 V CK1 CD1<br>240 V CF2 C2F C02 C12 C32<br>120 V CF CF C0 C1 C3<br>24 V CF7 C7F C07 C17 C37<br>12 V CF8 C8F C08 C18 C38<br>5 V CF9 C9F C09 C19 C39<br>Momentary without CgC CgT CeC CeT CeD ClC ClD<br>switch illumination<br>Other versions on request<br>TA35- CBD W F 120 C0<br>No other<br>features<br>Colours<br>Switch front rocker<br>W black white –<br>B black black –<br>r black red –<br>g black green –<br>Y black yellow –<br>X black orange –<br>1 black – clear transparent<br>3 black – red transparent<br>black – green transparent<br>6 black – orange transparent<br>7 black – blue transparent<br>Other colours on request<br>TT | | |<br>rocker legend Without thermal overload protection: code C00<br>Surface illustration Colour of print With thermal overload protection: rated current in (A)<br>F embossed In Code In Code In Code In Code<br>0,1 J01 1,2 J12 5,0 050 15,0 150<br>h printed white 0,2 J02 1,5 J15 6,0 060 16,0 160<br>0,3 J03 2,0 J20 7,0 070 18,0 180<br>K printed black<br>0,4 J0 2,5 J25 8,0 080 20,0 200<br>l printed white 0,5 J05 3,0 030 10,0 100<br>0,8 J08 3,5 035 12,0 120<br>M printed black 1,0 J10 4,0 00 14,0 10<br>Other legends on request Other rated currents on request<br>l 0<br>ON OFF<br>ON OFF<br>l 0<br>l 0<br>**----- End of picture text -----**<br> **5** **circuit breakers** **circuit breakers** ## **DiMenSionS** ## **TA35 1-pole** **==> picture [303 x 197] intentionally omitted <==** **----- Start of picture text -----**<br> 36 17.5<br>34 9.9<br>va Et<br>Label<br>L<br>5<br>fs 7 4 P1<br>Quick connect terminal<br>21.3 2.3 12.5<br>IEC 61210 A2.8-0.4<br>(illuminated version only) Th 33.8 14.5<br>Quick connect terminal<br>IEC 61210 A6.3-0.8<br>1.7<br>7.2<br>7.8 33.5<br>44.1<br>LINE<br>10.6<br>**----- End of picture text -----**<br> **==> picture [122 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> +0.2<br>14.5 0<br>Panel thickness 1.0…4.0 mm<br>0<br>+0.2<br>34<br>**----- End of picture text -----**<br> ## **TA35 2-pole** **TA35 3-pole** **==> picture [426 x 430] intentionally omitted <==** **----- Start of picture text -----**<br> 36 29<br>+0.2<br>34 20.9 26 0<br>Label<br>L<br>7 4 P1<br>ms a fn<br>21.3 2.3 11 6.1 Panel thickness 1.0…4.0 mm<br>33.8 23.5<br>ae<br>26<br>Quick connect terminal<br>IEC 61210 A6.3-0.8<br>36 40.5<br>34 31.9 37.5 +0.20<br>Label<br>L<br>7 4 P1 ded<br>[| Saal<br>21.3 2.3 11 11 6.1<br>Panel thickness 1.0…4.0 mm<br>___l [oe<br>33.8 34.5<br>ae A<br>37.4<br>Quick connect terminal<br>IEC 61210 A6.3-0.8<br>1.7<br>7.2<br>0<br>+0.2<br>33.5 34<br>44.1<br>LINE<br>10.5 10.6<br>1.7<br>7.2<br>0<br>+0.2<br>33.5 34<br>44.1<br>LINE<br>10.5 10.6<br>**----- End of picture text -----**<br> **6** **circuit breakers** **TA35** ~~**www.schurter.com/pg17_18_19**~~ **ACCeSSorieS Cover / collar for protection ip 65** ## **CZZ11 (1-pole)** **==> picture [457 x 405] intentionally omitted <==** **----- Start of picture text -----**<br> +0.2<br>14.5 0<br>34 20<br>ree<br>52<br>27.8<br>44 ±0.15<br>CZZ21 (2-pole)<br>34 31 +0.2<br>oe = 26 0<br>52<br>27.8<br>aa 44 ±0.15<br>10.3 9.8 9.7<br>+0.2 0 ±0.15<br>34 44<br>3 5.7<br>23.5 13.8 2.5<br>10.3 9.8 9.7<br>0<br>+0.2 ±0.15<br>34 44<br>3 5.7<br>35 24.6<br>2.5<br>**----- End of picture text -----**<br> **CZZ21 (2-pole)** **CZZ31 (3-pole)** **==> picture [466 x 184] intentionally omitted <==** **----- Start of picture text -----**<br> 34 42<br>38<br>= = -;<br>52<br>+0.2<br>37.5 0<br>2.5<br>27.8<br>44 ±0.15<br>La<br>10.3 9.8 9.7<br>0<br>+0.2<br>44 34<br> ±0.15<br>46.5 36.1 38<br>3 5.7<br>**----- End of picture text -----**<br> **7** **circuit breakers**
Updated at June 5, 2026
SCHURTER is a globally recognized innovator and manufacturer of high-quality electronic components, specializing in products that ensure a safe and clean supply of power. With a strong reputation in the electronics and PCB assembly industries, the company delivers reliable solutions engineered to protect critical circuits, streamline device operation, and optimize electrical performance across diverse applications. The core of our SCHURTER portfolio revolves around comprehensive circuit protection. We carry an extensive selection of standard and resettable fuses, accompanied by robust fuse holders, to safeguard sensitive electronics against overcurrent conditions. Furthermore, our offering features high-performance thermal circuit breakers and associated accessories, providing dependable protection and rapid reset capabilities for demanding industrial and commercial environments. Beyond fundamental circuit protection, SCHURTER excels in electromagnetic compatibility (EMC) and RFI suppression technologies. Our range includes precision-engineered power line filters and common mode chokes designed to mitigate electromagnetic interference and ensure signal integrity. Accompanied by specialized components such as AC/DC LED power supplies, SCHURTER provides the meticulous engineering and durability necessary for modern, high-reliability electronic design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →