T1N025TL
CIRCUIT BREAKER, 3 POLE, 25A
- Manufacturer: ABB
- Product type: Thermal Magnetic Circuit Breakers
- No. of Poles: 3 Pole
- Product Range: Tmax T1 Series
- Current Rating: 25A
- Voltage Rating VAC: 347VAC
- Voltage Rating VDC: 500VDC
- Circuit Breaker Mounting: Panel
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 249.24 € |
| Current stock | 10+ |
| Lead time | 30 days |
17 ## **Molded case circuit breakers** Index ## 17 - Molded case circuit breakers Formula MCCBs ......................................................17.1 - 17.10 General information Introduction ......................................................................................................................17.1 Circuit breakers for power distribution ..............................................................................17.2 Catalog number explanation .............................................................................................17.3 Ordering details A1, 100A ..........................................................................................................................17.4 A2, 250A, 600Y/347V, 480V ∆ .........................................................................................17.5 Accessories .....................................................................................................................17.6 -17.9 Tmax MCCBs .........................................................17.11 - 17.10 General information Introduction ....................................................................................................................17.11 Ordering details guide ........................................................................................17.12 - 17.13 Catalog number explanation ...........................................................................................17.14 Ordering details T1, 100A, 600Y/347V, 480V ∆ ...........................................................................17.15 - 17.16 T2, 100A, 480V ∆ ..............................................................................................17.17 - 17.19 T3, 225A, 600Y/347V, 480V ∆ ...........................................................................17.20 - 17.22 Ts3, 150A, 600V ∆, 225A, 480V ∆ .....................................................................17.23 - 17.26 T4, 250A, 600V ∆ ..............................................................................................17.27 - 17.32 T5, 400/600A, 600V ∆ .......................................................................................17.33 - 17.37 T6, 600A, 800A, 600V ∆ ....................................................................................17.38 - 17.40 T7 (Toggle), 1000A, 1200A, 600V ∆ ...............................................................................17.41 T7, 1000A, 1200A, 600V ∆ ................................................................................17.42 - 17.44 T7M (Stored energy) ...........................................................................................17.45 - 17.55 T8, 1600/2000/2500/3000A, 600VAC ∆ ............................................................17.56 - 17.66 Tmax UL489B Photovoltaic circuit breakers ........17.67 - 17.70 General information Introduction ....................................................................................................................17.67 Catalog number explanation ...........................................................................................17.68 Ordering details Tmax UL489B MCCBs and switches .............................................................................17.69 Jumper kit accessories...................................................................................................17.70 Accessories, T1 - T7 ..............................................17.71 - 17.83 Approximate dimensions, T1 - T7 .......................17.84 - 17.101 17.A Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A **Notes** 17 **==> picture [68 x 55] intentionally omitted <==** **----- Start of picture text -----**<br> Molded case<br>circuit breakers<br>**----- End of picture text -----**<br> 17.B Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## FORMULA ## Molded case circuit breakers ## Introduction ABB’s FORMULA molded case circuit breaker line offers simplicity and quality in some of the smallest dimensions available. The A1 breaker frame size ranges in amperes from 15 through 100 and the A2 breaker frame size ranges from 125 through 250 amperes. All UL FORMULA circuit breakers offer protection trip units that have fixed thermal and magnetic threshold values and are standard as a fixed version with front terminals. Standards UL 489 & IEC 60947-2 Dimensions (W x D x H): 1 pole: 1.00 x 2.36 x 5.12 2 pole: 2.00 x 2.36 x 5.12 3 pole: 3.00 x 2.36 x 5.12 Weight: 1 pole: 0.54 lbs 2 pole: 1.04 lbs 3 pole: 1.54 lbs Available accessories: Shunt opening release (2p & 3p) Undervoltage release (2p & 3p) Auxiliary contacts (2p & 3p) Termination kits (1p, 2p & 3p) Padlocks (1p, 2p & 3p) Direct and extended rotary handles (3p) 17.1 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## **Circuit breakers for power distribution** Technical data **==> picture [526 x 288] intentionally omitted <==** **----- Start of picture text -----**<br> A1 A2<br>Frame size A 100 250<br>Rated current, In A 15...100 125...250<br>Poles [Nr] Nr 1, 2, 3 1, 2, 3<br>Rated service voltage, Ue (AC) 50-60 Hz V 240 (1p, 2p, 3p) 240 (1p, 2p, 3p)<br>(DC) V 125 (1p), 250 (2p,3p) 125 (1p), 250 (2p,3p)<br>Versions Fixed Fixed<br>Performance Level A N A N<br>Poles Nr 1 2, 3 1 2, 3 1 2, 3 1 2, 3<br>Rated ultimate short circuit breaking capacity, Icu<br> Interrupting rating @ 240 V 50-60 Hz (AC) kA 10 10 18 25 10 10 14 25<br> Interrupting rating @ 125 V (DC) 1 pole (in 2012) kA 5 - 10 - 5 - 10 -<br> Interrupting rating @ 250 V (DC) 2 poles in series (2p, 3p) (in 2012) kA - 5 - 10 - 10 - 25<br>Reference Standard UL 489 UL 489<br>Isolation behavior Yes Yes<br>Fixing onto DIN rail DIN EN 50022 DIN EN 50022<br>Dimensions (Width x Depth x Height)<br> 1 pole in 1.00 x 2.36 x 5.12 1.38 x 2.36 x 5.91<br> 2 poles in 2.00 x 2.36 x 5.12 2.76 x 2.36 x 5.91<br> 3 poles in 3.00 x 2.36 x 5.12 4.13 x 2.36 x 5.91<br>Weight<br> 1 pole lbs 0.54 0.82<br> 2 poles lbs 1.04 1.61<br> 3 poles lbs 1.54 2.43<br>Trip Unit - Thermomagnetic TMF Yes Yes<br>**----- End of picture text -----**<br> 17.2 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage **Circuit breakers for power distribution** Catalog number explanation 17 **==> picture [18 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> A<br>**----- End of picture text -----**<br> W Number of Poles -1= 1 pole (UL&IEC) -2= 2 pole (UL&IEC) None= 3 pole (UL&IEC) -4= 4 pole (IEC) Type Connectors W=none ~~T~~ rip Unit Function T=thermalmagnetic (UL&IEC) A=ELT - LI (IEC) Current Rating 015=15A (UL&IEC); 016=16A (IEC) 020=20A (UL&IEC); 025=25A (UL&IEC) 030=30A (UL&IEC); 032=32A (IEC) 040=40A (UL&IEC); 050=50A (UL&IEC) 060=60A (UL&IEC); 063=63A (IEC) 070=70A (UL&IEC); 080=80A (UL&IEC) 090=90A (UL&IEC); 100=100A (UL&IEC) 125=125A (UL&IEC); 150=150A (UL&IEC) 160=160A (UL&IEC); 175=175A (UL&IEC) 200=200A (UL&IEC); 225=225A (UL&IEC) 250=250A (UL&IEC); 320=320A (IEC) 400=400A (IEC); 500=500A (IEC); 630=630A (IEC) ~~I~~ nterrupting Rating Class A=adequate(UL&IEC); B=basic(IEC); C=common(IEC) N=normal(UL&IEC); S=standard(IEC) ~~F~~ rame Size: 1=100A, UL; 2=250A, UL A=125A, IEC; B=250A, IEC; C=400A, IEC; D=630A, IEC 17.3 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A A1 100A 1 Pole 2 Pole 3 Pole A1 - 100A Frame TMF, thermal magnetic fixed - fixed mount (F), front terminals (F) |Breaker|IC at<br>240VAC|Rating<br>(A)|Magnetic trip|1 pole<br>catalog number|2 pole<br>catalog number|3 pole<br>catalog number| |---|---|---|---|---|---|---| |A1A|10kA|15|400|A1A015TW-1|A1A015TW-2|A1A015TW| |||20|400|A1A020TW-1|A1A020TW-2|A1A020TW| |||25|400|A1A025TW-1|A1A025TW-2|A1A025TW| |||30|400|A1A030TW-1|A1A030TW-2|A1A030TW| |||40|400|A1A040TW-1|A1A040TW-2|A1A040TW| |||50|500|A1A050TW-1|A1A050TW-2|A1A050TW| |||60|600|A1A060TW-1|A1A060TW-2|A1A060TW| |||70|700|A1A070TW-1|A1A070TW-2|A1A070TW| |||80|800|A1A080TW-1|A1A080TW-2|A1A080TW| |||90|900|A1A090TW-1|A1A090TW-2|A1A090TW| |||100|1000|A1A100TW-1|A1A100TW-2|A1A100TW| |A1N|1 pole<br>18kA<br>2-3 pole<br>25kA|15|400|A1N015TW-1|A1N015TW-2|A1A015TW| |||20|400|A1N020TW-1|A1N020TW-2|A1A020TW| |||25|400|A1N025TW-1|A1N025TW-2|A1A025TW| |||30|400|A1N030TW-1|A1N030TW-2|A1A030TW| |||40|400|A1N040TW-1|A1N040TW-2|A1A040TW| |||50|500|A1N050TW-1|A1N050TW-2|A1A050TW| |||60|600|A1N060TW-1|A1N060TW-2|A1A060TW| |||70|700|A1N070TW-1|A1N070TW-2|A1A070TW| |||80|800|A1N080TW-1|A1N080TW-2|A1A080TW| |||90|900|A1N090TW-1|A1N090TW-2|A1A090TW| |||100|1000|A1N100TW-1|A1N100TW-2|A1A100TW| 17 17.4 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## A2 250A, 600Y/347V, 480V ∆ Thermal-magnetic 1 Pole 2 Pole 3 Pole ## A2 - 250A Frame TMF, thermal magnetic fixed - fixed mount (F), front terminals (F) |Breaker|IC at<br>240VAC|Rating<br>(A)|Magnetic trip|1 pole<br>catalog number|2 pole<br>catalog number|3 pole<br>catalog number| |---|---|---|---|---|---|---| |A2A|10kA|125|1250|A2A125TW-1|A2A125TW-2|A2A125TW| |||150|1500|A2A150TW-1|A2A150TW-2|A2A150TW| |||175|1750|A2A175TW-1|A2A175TW-2|A2A175TW| |||200|2000|A2A200TW-1|A2A200TW-2|A2A200TW| |||225|2250|A2A225TW-1|A2A225TW-2|A2A225TW| |||250|2500|A2A250TW-1|A2A250TW-2|A2A250TW| |A1N|1 pole<br>18kA<br>2-3 pole<br>25kA|125|1250|A2N125TW-1|A2N125TW-2|A2N125TW| |||150|1500|A2N150TW-1|A2N150TW-2|A2N150TW| |||175|1750|A2N175TW-1|A2N175TW-2|A2N175TW| |||200|2000|A2N200TW-1|A2N200TW-2|A2N200TW| |||225|2250|A2N225TW-1|A2N225TW-2|A2N225TW| |||250|2500|A2N250TW-1|A2N250TW-2|A2N250TW| 17.5 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A **==> picture [48 x 41] intentionally omitted <==** **----- Start of picture text -----**<br> FORMULA<br>MCCBs<br>**----- End of picture text -----**<br> ## Accessories Electrical A1 - A2 ## Shunt opening release (SOR) |Frame size|Voltage|Catalog number| |---|---|---| ||12VDC|KA2S9| ||24-30VAC/DC|KA2S8| |A1 - A2|48-60VAC/DC|KA2S7| ||110-127VAC|KA2S4| ||220-240VAC|KA2S2| The shunt opening release allows for opening of the circuit breaker by means of a non-permanent electrical control. Operation of the release is guaranteed for a voltage between 70% and 110% of the power supply rated voltage value. Cabled service release SOR-C and UVR-C ## Undervoltage release (UVR) |Frame size|Voltage|Catalog number| |---|---|---| |A1 - A2|24-30VAC/DC|KA2U8| ||48VAC/DC|KA2U7| ||60VAC/DC|KA2U5| ||110-127VAC|KA2U4| ||220-240VAC|KA2U2| The undervoltage release ensures opening of the circuit breaker for lack/lowering of the release power supply voltage. Operation of the release is guaranteed for a voltage between 70% and 35% of the power supply rated voltage value. After tripping, the circuit breaker can be closed again starting from a voltage higher than 85% of the power supply rated voltage value. ## Auxiliary contacts (AUX) & early auxiliary contacts (AUE) |Frame size|Description|2 Pole<br>Catalog number|3 Pole<br>Catalog number| |---|---|---|---| |A1 - A2|AUX-C 1Q+1SY 250 VAC/DC|KA2AS-2|KA2AS| ||AUX-C 2Q+1SY 250 VAC/DC|KA2AS2-2|KA2AS2| ||AUX-C 1Q+1SY 24 VDC|KA2ASAU-2|KA2ASAU| ||AUX-C 2Q+1SY 24 VDC|KA2AS2AU-2|KA2AS2AU| ||AUX-C 250V 1 CONT. SPARE PART*|KA2ASSP|KA2ASSP| ||AUE 2 CONTACTS x RHx|–|KA2RH-EM| The auxiliary contacts allow information about the state of the circuit breaker to be available through an electronic signal to another apparatus. The early auxiliary contacts are normally open contacts which allow the undervoltage release to be supplied in advance prior to the closing of the main contacts in direct and extended rotary handle operating mechanisms. 17 _ > 2 Rated 480Y/277 VAC for 15A. > 3 When protected by a OCPD with appropriate ratings. 1 Electrical/mechanical accessories cannot be installed on single pole breakers. 17.6 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Accessories Mechanical A1 - A2 Terminal FCCuAl Terminal FCCuAl with cable Front terminals for copper aluminum cables - FCCuAL |Frame size|Description|1 piece<br>catalog number|2 piece<br>catalog<br>number|3 piece<br>catalog<br>number|4 piece<br>catalog<br>number|6 piece<br>catalog<br>number| |---|---|---|---|---|---|---| |A1|KIT FC CuAl A1 80A<br>KIT FC CuAl A1 100A|KA1080-1<br>KA1100-1|KA1080-2<br>KA1100-2|KA1080-3<br>KA1100-3|KA1080-4<br>KA1100-4|KA1080-6<br>KA1100-6| |A2|KIT FC CuAl A2 225A*<br>KIT FC CuAl A2 250A|KA2225-1<br>KA2250-1|KA2225-2<br>KA2250-2|KA2225-3<br>KA2250-3|KA2225-4<br>KA2250-4|KA2225-6<br>KA2250-6| - 250A Cu cables and 225A Al cables Terminal F Terminal F with cable lug Terminal F with busbar Front terminals - F |Frame size|Description|1piece catalognumber|2piece catalognumber|3piece catalognumber|4piece catalognumber|6piece catalognumber| |---|---|---|---|---|---|---| |A1|KIT F A1|KA1F-1|KA1F-2|KA1F-3|KA1F-4|KA1F-6| |A2|KIT F A2|KA2F-1|KA2F-2|KA2F-3|KA2F-4|KA2F-6| Front terminals are supplied as standard with all FORMULA circuit breakers. Terminal EF Terminal EF with busbar Front extended terminals - EF (IEC only) |Frame size|Description|1 piece<br>catalog number|2 piece<br>catalog<br>number|3 piece<br>catalog<br>number|4 piece<br>catalog<br>number|6 piece<br>catalog<br>number| |---|---|---|---|---|---|---| |A1|KIT EF A1|KA1EF-1|KA1EF-2|KA1EF-3|KA1EF-4|KA1EF-6| |A2|KIT EF A2|KA2EF-1|KA2EF-2|KA2EF-3|KA2EF-4|KA2EF-6| 17.7 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A ## Accessories Mechanical A1 - A2 Terminal ES Terminal ES with cable lug Terminal ES with busbar Front extended spread terminals - ES (IEC only) |Frame size|Description|1 piece<br>catalog number|2 piece<br>catalog<br>number|3 piece<br>catalog<br>number|4 piece<br>catalog<br>number|6 piece<br>catalog<br>number| |---|---|---|---|---|---|---| |A1|KIT ES A1|–|KA1ES-2|KA1ES-3|KA1ES-4|KA1ES-6| |A2|KIT ES A2|–|KA2ES-2|KA2ES-3|KA2ES-4|KA2ES-6| Terminal covers - low profile (LTC) and high profile (HTC) High terminal cover (HTC) |Frame size|Description|Catalog<br>number| |---|---|---| |A1|LTC 3p- 2pcs|KA1LTC-3| ||HTC 3p- 2pcs|KA1HTC-3| |A2|LTC 3p- 2pcs|KA2LTC-3| ||HTC 3p- 2pcs|KA2HTC-3| |A1 - A2|Sealable screws for terminal covers*|KA2SSW-T| ||Sealable screws for front*|KA2SSW-F| * IEC rated only Low terminal cover (LTC) 17 = yl , Phase barriers - low profile and high profile |Frame size|Description|2-Piece<br>catalog<br>number|4-Piece<br>catalog<br>number| |---|---|---|---| |A1|PB 50mm|KA1PBL-2|KA1PBL-3| |A2|PB 80mm|KA2PBL-2|KA2PBL-3| |A1 - A2|PB 100mm|KA2PBH-2|KA2PBH-3| Phase barriers Direct mount rotary handle (RHD) |Frame size|Description|Catalog<br>number| |---|---|---| |A1 - A2|RHD A1-A2 STANDARD DIRECT<br>RHD A1-A2 EMERGENCY DIRECT<br>~~|~~|KA2RHD<br>KA2RHDEM| Direct handle (RHD) 17.8 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A Accessories Mechanical A1 - A2 17 Extended mount rotary handle (RHE) |Frame size|Description|Catalog<br>number| |---|---|---| |A1 - A2|RHE KIT A1-A2 STANDARD EXTENDED|KA2RHE| ||RHE KIT A1-A2 EMERGENCY EXTENDED|KA2RHEEM| ||RHE A1-A2 BASE|KA2RHE-B| ||RHE A1-A2 SHAFT|KA2RHE-S| ||RHE A1-A2 STANDARD HANDLE|KA2RHE-H| ||RHE A1-A2 EMERGENCY HANDLE|KA2RHE-HEM| Extended handle (RHE) ## Padlocks for lever operating mechanism (PLL) |Frame size|Description|Catalog<br>number| |---|---|---| |A1 - A2|PLL - removable in openposition(1p,2p,3p)|KA2LDOR| ||PLL - fixed in openposition(3p)|KA2LDOR| ||PLL - fixed in open and closedposition(3p)|KA2LD| Fixed padlock in open position (PLL) Fixed padlock in open and closed position (PLL) Removable padlock in open position (PLL) Key lock on handle and front lever operating mechanism (RHL) (IEC only) Key lock for direct handle |Frame size|Description|Catalog<br>number| |---|---|---| |A1 - A2|RHL-D openposition,different keys|KA2RHLO| ||RHL-S openposition,type A key|KA2RHLO-A| ||RHL-S openposition, type B key|KA2RHLO-B| ||RHL-S openposition,type C key|KA2RHLO-C| ||RHL-S openposition,type D key|KA2RHLO-D| ||RHL-D open and closedposition,different keys|KA2RHL| Bracket for fixing on DIN rail (IEC only) |Frame size|Description|Catalog<br>number| |---|---|---| |A1 - A2|Bracket for 1p,2p,3p|KA2DIN| Bracket for DIN rail 17.9 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Notes 17 17.10 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Tmax Molded case circuit breakers ## Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high performance, versatility and standardization in a range of molded case circuit breakers. The ABB Tmax line of circuit breakers, with a range up to 3000A, has several key features that go along with its very small size: - Double insulation – this construction characteristic allows for the UL Listed field installation of internal accessories without exposure to energized parts. - Complete range of electrical and mechanical accessories - Positive operation – breakers from ABB ensure that the toggle indicates the precise position of the moving contacts. This guarantees safe and reliable signaling by the device. - Installation – Tmax molded case circuit breakers can be installed in panels and switchboards in either the horizontal or vertical planes while being fed from either end without any derating of their performance characteristics. - Interrupting ratings at 480VAC up to 150kAIC. The ABB Tmax product line has the performance and accessories to satisfy all industry requirements in the 600VAC to 600VDC ranges. ## Frame sizes — Nine basic sizes The ABB Tmax series includes nine basic frame sizes as well as the T1 single pole with the range rated from 15A to 3000A at 480VAC. The various versions carry the following interrupting capacities: - B Basic breaking capacity - N Normal breaking capacity - S Standard breaking capacity - H High breaking capacity - L Extra high breaking capacity - V Very high breaking capacity ## Derived versions - Thermal magnetic - Electronic - Molded case switches - Motor circuit protectors (MCPs) - Direct current (DC) rated ## ABB Tmax versions - Fixed: all models - Drawout or plug-in: T2, T3, Ts3, T4, T5, T6, T7 & T7M - UL File #E93565 (breakers and MCPs) #E116596 (Accessories) #E116595 (Molded case switches) 17 - Compact size - All Tmax molded case circuit breakers are UL Listed and IEC rated for global application and acceptance. - All versions of the Tmax family are suitable for reverse feed applications. 17.11 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A **==> picture [37 x 33] intentionally omitted <==** **----- Start of picture text -----**<br> Tmax<br>MCCBs<br>**----- End of picture text -----**<br> **==> picture [18 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> T1 1P<br>**----- End of picture text -----**<br> ## Selection Guide Circuit breakers for power distribution T1 – Ts3 T1 T2 T3 Ts3 |Type|Tmax T1 1p|Tmax T1|Tmax T2|Tmax T3|Tmax Ts3|Tmax Ts3| |---|---|---|---|---|---|---| |Frame size<br>[A]|100|100|100|225|150|225| |Number of poles<br>[Nr]|1|3-4|3-4|3-4|2-3-4|2-3-4| |Rated voltage AC (50-60Hz)<br>[V]|347|600Y/347|480|600Y/347|600|480| |DC<br>[V]||500||500|600|500| |Interruptingratings|B|N|S<br>H|N<br>S|N<br>H<br>L|N<br>H<br>L| |240V AC<br>[kA rms]||502|65<br>150|50<br>65|65<br>100<br>150|65<br>100<br>150| |277V AC<br>[kA rms]|181|||||| |347V AC<br>[kA rms]|141|||||| |480V AC<br>[kA rms]||222|35<br>65|25<br>35|25<br>50<br>855|25<br>50<br>65| |600Y/347V AC<br>[kA rms]||10||10<br>10||| |600V AC<br>[kA rms]|||||14<br>14<br>25|| |250V DC (2 poles in series)<br>[kA rms]||25||25<br>35||| |500V DC (3 poles in series)<br>[kA rms]||25||25<br>35||| |500V DC (2 poles in series)<br>[kA rms]|||||35<br>50<br>65|20<br>35<br>50| |600V DC (3 poles in series)<br>[kA rms]|||||20<br>35<br>50|| |Trip units<br>TMF|■|■|■|■|■|■| |TMD/TMA||||||| |ELT|||■|||| |MA|||■|■|■|■| |Electronic|||■|||| |Dimensions<br>H<br>[in/mm]|5.12/130|5.12/130|5.12/130|5.9/150|6.7/170|6.7/170| |W 3p<br>[in/mm]|1/25.4|3/76|3.54/90|4.13/105|4.13/105|4.13/105| |D<br>[in/mm]|2.76/70|2.76/70|2.76/70|2.76/70|4.07/103.5|4.07/103.5| |Mechanical life<br>[No. operations]|25000|25000|25000|25000|25000|25000| 17 > 1 In15A = 10kA@277VAC 10kA@347VAC > 2 In15A = 35kA@240VAC 14kA@480Y/277 VAC > 3 T5 600 with electronic trip units only and in three pole version > 4 2p breakers: available only in N interrupting rating > 5 In from 15A up to 30A=65kA@480V AC 17.12 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Selection Guide Circuit breakers for power distribution T4 – T8 T4 T5 T6 T7 T8 **==> picture [514 x 295] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Type|Tmax T4|Tmax T5|Tmax T6|Tmax T7/T7M|Tmax T8| |1600, 2000,| |Frame size|[A]|250|400-600 3|800|1000-1200|2500 & 3000| |Number of poles|[Nr]|2-3-4 4|2-3-4 4|3-4|3-4|3-4| |Rated voltage AC (50-60Hz)|[V]|600|600|600|600|600| |DC|[V]|600|600|600| |Interrupting ratings|N|S|H|L|V|N|S|H|L|V|N|S|H|L|S|H|L|V| |240V AC|[kA rms]|65|100|150|200|200|65|100|150|200|200|65|100|200|200|65|100|150|125| |277V AC|[kA rms]| |347V AC|[kA rms]| |480V AC|[kA rms]|25|35|65|100|150|25|35|65|100|150|35|50|65|100|50|65|100|125| |600Y/347V AC|[kA rms]| |600V AC|[kA rms]|18|25|35|65|100|18|25|35|65|100|20|25|35|42|25|50|65|100| |250V DC (2 poles in series)|[kA rms]| |500V DC (3 poles in series)|[kA rms]| |500V DC (2 poles in series)|[kA rms]|25|35|50|65|100|25|35|50|65|100|35|35|50|65| |600V DC (3 poles in series)|[kA rms]|16|25|35|50|65|16|25|35|50|65|20|20|35|50| |Trip units|TMF|■| |TMD/TMA|■|■|■| |ELT| |MA| |Electronic|■|■|■|■| |Dimensions|H|[in/mm]|8.07/205|8.07/205|10.55/268|10.55/268|15 / 382| |W 3p|[in/mm]|4.13/105|5.51/140|8.26/210|8.26/210|16.8 / 427| |D|[in/mm]|4.07/103.5|4.07/103.5|4.07/103.5|6.06/154 (toggle)7/178 (motor)|11.2 / 282| |Mechanical life|[No. operations]|20,000|20,000|20,000|10,000|15,000| **----- End of picture text -----**<br> > 1 In15A = 10kA@277 VAC 10kA@347 VAC > 2 In15A = 35kA@240 VAC 14kA@480Y/277 VAC > 3 T5 600 with electronic trip units only and in three pole version- > 4 2p T4N250 and T5N400 available only in N interrupting capacity. > 5 In from 15A up to 30A=65kA@480 VAC > 6 Applies to MCS only. 17.13 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A General information Catalog number explanation 17 ## - T3 S 080 T W 4 xxx Accessories (added in alpha-numeric order)[1] A = Auxiliary Switch S_ = Shunt trip with voltage code U_ = Undervoltage release with voltage code Number of poles -1 =1 pole (T1 only) -2 = 2 pole -4 = 4 pole None = 3 pole Type connectors W = None L = Lugs included Trip unit function B = LS/I (AC only) D = Molded Case Switch (MCS) T = Thermal-magnetic M = Magnetic only (MCP) E5 = Electronic MCP (AC only) C = LSI (AC only) E = LSIG (AC only) CZ = LSI/PD 2 EZ = LSIG/PD 2 P = LI - LCD Display 3 R = LSI - LCD Display 3 S = LSIG - LCD Display 3 Current rating 015 = 15A 080 = 80A 100 = 100A 225 = 225A 250 = 250A 400 = 400A 600 = 600A 800 = 800A 1200 = 1200A Interrupting rating class B = Basic N = Normal S = Standard H = High L = Extra High V = Very high Q = 100% Rated Frame size T1 = 100A T2 = 100A T3 = 225A Ts3 = 225A T4 = 250A T5 = 400A, 600A T6 = 600A, 800A T7 = 1000A, 1200A (toggle) > 1 Consult ABB for factory installed accessories. > 2 Trip unit with communication module. > 3 Available on T7 toggle version only. 17.14 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage T1 100A, 600Y/347V, 480V ∆ Thermal-magnetic 17 Dimensions 3P Fixed Version 5.12H x 3.00W x 2.76D Weight 2.34 (Ibs) T1 ## General The T1 breaker family ranges from 15 through 100 amperes. The T1 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short circuit protection for the breaker is accomplished using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. ## Standards The UL489/CSA 22.2 version of T1 also carries an IEC-60947-2 rating. ## Versions ## UL489 / CSA C22.2 Interrupting capacity (kA RMS) |Voltage|Continuous rating|B (1 pole)|N| |---|---|---|---| |240VAC|15 – 100A|—|501| |347VAC|15A<br>20 – 100A|10<br>14|—<br>—| |480VAC ∆|15A2<br>20 – 100A|—<br>—|14<br>22| |600Y/347VAC|15 – 100A|—|10| |250VDC 2pole series|15 – 100A|—|25| |500VDC 3pole series|15 – 100A|—|25| The T1 frame is available in two versions: T = Thermal-magnetic, fixed D = Molded case switch ## Performance levels The T1 breaker has two performance levels available: B = Basic single pole N = Normal three pole ## Number of poles The T1 molded case circuit breaker is available in single, three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. ## IEC 60947-2 Interrupting capacity (kA RMS) |Voltage|Continuous rating|B (1 pole)|N| |---|---|---|---| |230VAC|15 – 100A|253|50| |415VAC|15 – 100A|—|36| |690VAC|15 – 100A|—|6| |500VDC 3pole series|15 – 100A|—|36| ## Molded case switches UL489 switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. > 1 In 15A 35kA @ 240VAC. > 2 15A available in 480Y/277 VAC only. > 3 Interrupting capacity for 16-20A is 16kA 17.15 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T1 100A, 600Y/347V, 480V ∆ Thermal-magnetic/Molded Case Switch ## T1B TMF — Single pole thermal magnetic fixed 1 |Breaker|IC at<br>277VAC|Rating<br>(A)|Magnetic trip<br>(A)|1 pole, 277VAC<br>catalog number| |---|---|---|---|---| |T1B|10kA|15|1000|T1B015TL-1| |||20|1000|T1B020TL-1| |||25|1000|T1B025TL-1| |||30|1000|T1B030TL-1| |||40|1000|T1B040TL-1| ||kA|50|1500|T1B050TL-1| ||18|60|1500|T1B060TL-1| |||70|1500|T1B070TL-1| |||80|1500|T1B080TL-1| |||90|1500|T1B090TL-1| |||100|1500|T1B100TL-1| ## T1N TMF — 3 pole thermal magnetic fixed |Breaker|IC at<br>480VAC|Rating<br>(A)|Magnetic trip<br>(A)|3 pole,<br>600Y/347VAC/500VDC<br>catalog number| |---|---|---|---|---| |T1N|14kA|15|1000|T1N015TL2| |||20|1000|T1N020TL| |||25|1000|T1N025TL| |||30|1000|T1N030TL| |||40|1000|T1N040TL| ||kA|50|1500|T1N050TL| ||22|60|1500|T1N060TL| |||70|1500|T1N070TL| |||80|1500|T1N080TL| |||90|1500|T1N090TL| |||100|1500|T1N100TL| ## T1N TMF — 100% Rated thermal-magnetic |Breaker|IC at<br>480VAC|Rating<br>(A)|Magnetic trip<br>(A)|3 pole,<br>600Y/347VAC/500VDC<br>catalog number| |---|---|---|---|---| |T1N|14kA|151|100|T1NQ015TL| |||20|1000|T1NQ020TL| |||25|1000|T1NQ025TL| |||30|1000|T1NQ030TL| |||40|1000|T1NQ040TL| ||kA|50|1500|T1NQ050TL| ||22|60|1500|T1NQ060TL| |||70|1500|T1NQ070TL| |||80|1500|T1NQ080TL| |||90|1500|T1NQ090TL| |||100|1500|T1NQ100TL| ## T1N-D — Molded case switch |Breaker|Interrupting<br>capacity3|Rating<br>(A)|Magnetic trip<br>(A)|480VAC/500VDC<br>catalog number| |---|---|---|---|---| |T1-D|240V,<br>50kA|100|1000|T1N100DL| > 1 Electrical/mechanical accessories cannot be installed on single pole breakers. > 2 Rated 480Y/277 VAC for 15A. > 3 When protected by a OCPD with appropriate ratings. 17.16 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## T2 100A, 480V ∆ Thermal-magnetic/electronic/current limiting Dimensions 3P Fixed Version 5.12H x 3.54W x 2.76D Weight 2.84 (Ibs) Weight T2 ## General The T2 breaker family ranges from 15 through 100 amperes. The T2 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection as well as a version with microprocessor-based electronic trip unit. Thermal overload protection is provided by heat sensitive bimetals. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. ## Standards The UL489/CSA 22.2 version of T2 also carries an IEC-60947-2 rating. ## Versions The T2 frame is available in four versions: T = Thermal-magnetic, fixed B = Adjustable LS/I electronic ## UL489 / CSA C22.2 Interrupting capacity (kA RMS) |Voltage|Continuous rating|S|H| |---|---|---|---| |240VAC|15 – 100A|65|150| |480VAC ∆|15 – 100A|35|65| ## IEC 60947-2 Interrupting capacity (kA RMS) |Voltage|Continuous rating|S|H| |---|---|---|---| |230VAC|15 – 100A|85|100| |415VAC|15 – 100A|50|70| |690VAC|15 – 100A|7|8| |500VDC 3 pole series|15 – 100A|50|70| - M = Magnetic only (MCP) - E5 = Electronic instantaneous only (MCP) ## Trip functions These tripping functions are available: L = Long time - S = Short time - I - Instantaneous ## Performance levels The T2 breaker has two performance levels available: S = Standard H = High - UL Current Limiting ## Number of poles The T2 is available in three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. 17.17 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A ## ## T2 100A, 480V ∆ Thermal-magnetic/current limiting **==> picture [529 x 245] intentionally omitted <==** **----- Start of picture text -----**<br> T2 — 100A TMF thermal magnetic fixed T2 – 100A TMF, 100% rated thermal magnetic fixed<br>Breaker IC at Rating Magnetic trip 3 pole, 480VAC Breaker IC at Rating Magnetic trip 3 pole, 480VAC<br>480VAC (A) (A) Catalog number 480VAC (A) (A) Catalog number<br>15 500 T2S015TW 15 500 T2SQ015TW<br>20 500 T2S020TW 20 500 T2SQ020TW<br>25 500 T2S025TW 25 500 T2SQ025TW<br>30 500 T2S030TW 30 500 T2SQ030TW<br>40 500 T2S040TW 40 500 T2SQ040TW<br>T2S 50 500 T2S050TW T2S 50 500 T2SQ050TW<br>35kA 35kA<br>60 600 T2S060TW 60 600 T2SQ060TW<br>70 700 T2S070TW 70 700 T2SQ070TW<br>80 800 T2S080TW 80 800 T2SQ080TW<br>90 900 T2S090TW 90 900 T2SQ090TW<br>100 1000 T2S100TW 100 1000 T2SQ100TW<br>15 500 T2H015TW 15 500 T2HQ015TW<br>20 500 T2H020TW 20 500 T2HQ020TW<br>25 500 T2H025TW 25 500 T2HQ025TW<br>30 500 T2H030TW 30 500 T2HQ030TW<br>T2H 40 500 T2H040TW T2H 40 500 T2HQ040TW<br>UL UL<br>65kA 50 500 T2H050TW 65kA 50 500 T2HQ050TW<br>current current<br>limiting 60 600 T2H060TW limiting 60 600 T2HQ060TW<br>70 700 T2H070TW 70 700 T2HQ070TW<br>80 800 T2H080TW 80 800 T2HQ080TW<br>90 900 T2H090TW 90 900 T2HQ090TW<br>100 1000 T2H100TW 100 1000 T2HQ100TW<br>**----- End of picture text -----**<br> 17 17.18 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T2 100A, 480V ∆, 100% rated Electronic/Current limiting/MCP ## T2 — 100A Frame, electronic trip unit (AC only) |T2— 100A Fr|ame, electronic|trip unit (AC onl|y)|| |---|---|---|---|---| |Breaker|IC at<br>480VAC|Trip unit type|CT rating|3 pole, 480VAC<br>catalognumber| |T2S|35kA|PR221DS-LS/I|25A|T2S025BW| ||||60A|T2S060BW| ||||100A|T2S100BW| |T2H<br>UL Current<br>Limiting|||25A|T2H025BW| ||65kA|PR221DS-LS/I|60A|T2H060BW| ||||100A|T2H100BW| ## T2 – 100A Frame 100% rated, electronic trip unit (AC only) |T2– 100A Fra|me 100% rated|, electronic trip|unit (AC only)|| |---|---|---|---|---| |Breaker|IC at<br>480VAC|Trip unit type|CT rating|3 pole, 480VAC<br>catalog number| |T2S|35kA|PR221DS-LS/I|25A|T2SQ025BW| ||||60A|T2SQ060BW| ||||100A|T2SQ100BW| |T2H<br>UL Current<br>Limiting|||25A|T2HQ025BW| ||65kA|PR221DS-LS/I|60A|T2HQ060BW| ||||100A|T2HQ100BW| ## T2 — 100A Frame, instantaneous only (MCP) |T2— 100A Fr|ame, instantane|ous only (MCP)|||| |---|---|---|---|---|---| |Breaker|IC at<br>480VAC|Trip unit type|Rating|Adjustment<br>range|3 pole, 480VAC<br>Catalognumber| |T2S|||20A|120 - 240|T2S020MW| ||35kA|Mag only|50A|300 - 600|T2S050MW| ||||100A|600 – 1200|T2S100MW| |T2H|65kA|Mag only|20A|120 - 240|T2H020MW| ||||50A|300 - 600|T2H050MW| ||||100A|600 – 1200|T2H100MW| ## T2 — 100A Frame, instantaneous only, electronic (MCP - AC only) |T2— 100A Fr|ame, instantane|ous only, electro|nic (MCP - AC|only)|| |---|---|---|---|---|---| |Breaker|IC at<br>480VAC|Trip unit type|Rating|Adjustment<br>range|3 pole, 480VAC<br>Catalog number| |T2S|||25A|25 - 250|T2S025E5W| ||35kA|Instantaneous<br>onl|60A|60 - 600|T2S060E5W| |||y|100A|100 - 1000|T2S100E5W| |T2H|65kA|Instantaneous<br>only|25A|25 - 250|T2H025E5W| ||||60A|60 - 600|T2H060E5W| ||||100A|100 - 1000|T2H100E5W| 17.19 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## ## T3 225A, 600Y/347V, 480V ∆ Thermal-magnetic Dimensions 3P Fixed Version 5.9H x 4.13W x 2.76D Weight 5.45 (Ibs) T3 ## General The T3 breaker family ranges from 60 through 225 amperes. The T3 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short circuit protection begins at 10 times the thermal rating of the breaker using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. ## Standards The UL489/CSA 22.2 version of T3 also carries an IEC-60947-2 rating. ## Versions - The T3 frame is available in three versions: T = Thermal-magnetic, fixed - M = Magnetic only (MCP) - D = Molded case switch ## Performance levels ## UL489 / CSA C22.2 Interrupting capacity (kA RMS) |Voltage|Continuous rating|N|S| |---|---|---|---| |240VAC|60 – 225A|50|65| |480VAC ∆|60 – 225A|25|35| |600Y/347VAC|60 – 225A|10|10| |250VDC 2pole series|60 – 225A|25|35| |500VDC 3pole series|60 – 225A|25|35| ## IEC 60947-2 Interrupting capacity (kA RMS) |Voltage|Continuous rating|N|S| |---|---|---|---| |230VAC|60 – 225A|50|85| |415VAC|60 – 225A|36|50| |690VAC|60 – 225A|5|8| |750VDC 3pole series|60 – 225A|36|50| The T3 breaker has two performance levels available: N = Normal - S = Standard ## Number of poles The T3 molded case circuit breaker is available in three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. ## Molded case switches UL489 switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. 17.20 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T3 225A, 600Y/347V, 480V ∆ Thermal-magnetic T3 — 225A Frame TMF, thermal magnetic fixed T3 – 225A Frame TMF, 100% rated thermal magnetic fixed **==> picture [528 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> Breaker 480VACIC at Rating(A) Magnetic trip(A) 3 pole, 480VAC/500VDCCatalog number Breaker 480VACIC at Rating(A) Magnetic trip(A) 3 pole, 600/347V CataloVAC/500VDCg number<br>60 600 T3N060TW 60 600 T3NQ060TW<br>70 700 T3N070TW 70 700 T3NQ070TW<br>80 800 T3N080TW 80 800 T3NQ080TW<br>90 900 T3N090TW 90 900 T3NQ090TW<br>100 1000 T3N100TW 100 1000 T3NQ100TW<br>T3N 25kA T3N 25kA<br>125 1250 T3N125TW 125 1250 T3NQ125TW<br>150 1500 T3N150TW 150 1500 T3NQ150TW<br>175 1750 T3N175TW 175 1750 T3NQ175TW<br>200 2000 T3N200TW 200 2000 T3NQ200TW<br>225 2250 T3N225TW 225 2250 T3NQ225TW<br>60 600 T3S060TW 60 600 T3SQ060TW<br>70 700 T3S070TW 70 700 T3SQ070TW<br>80 800 T3S080TW 80 800 T3SQ080TW<br>90 900 T3S090TW 90 900 T3SQ090TW<br>100 1000 T3S100TW 100 1000 T3SQ100TW<br>T3S 35kA T3S 35kA<br>125 1250 T3S125TW 125 1250 T3SQ125TW<br>150 1500 T3S150TW 150 1500 T3SQ150TW<br>175 1750 T3S175TW 175 1750 T3SQ175TW<br>200 2000 T3S200TW 200 2000 T3SQ200TW<br>225 2250 T3S225TW 225 2250 T3SQ225TW<br>**----- End of picture text -----**<br> 17.21 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T3 225A, 600Y/347V, 480V ∆ MCP/Molded case switch ## T3 — 225A Frame instantaneous only, (MCP) |T3— 225A Fra|me instantaneo|us only, (MCP)|||| |---|---|---|---|---|---| |<br>Breaker|<br>IC at<br>488-VAC|<br>Trip unit<br>type|Rating|Adjustment<br>range|3 pole, 480VAC<br>Catalognumber| |T3S|||100A|600 – 1200|T3S100MW| ||3kA|M l|125A|750 - 1500|T3S125MW| ||5|ag ony|150A|900 - 1800|T3S150MW| ||||200A|1200 - 2400|T3S200MW| ## T3S-D — Molded case switch **==> picture [416 x 38] intentionally omitted <==** **----- Start of picture text -----**<br> Breaker Interrupting Rating Magnetic trip 3 pole, 480VAC/500VDC<br>capacity 1 (A) (A) Catalog number<br>T3S-D 240V, 65kA 150 1500 T3S150DW<br>480V, 35kA 225 2250 T3S225DW<br>**----- End of picture text -----**<br> 1 When protected by a OCPD with appropriate ratings. 17.22 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Ts3 150A, 600V ∆, 225A, 480V ∆ Thermal magnetic Dimensions 3P Fixed Version 6.7H x 4.13W x 4.07D Weight 6.75 (Ibs) Ts3 ## General The Ts3 breaker family ranges from 15 through 225 amperes. The Ts3 trip mechanisms are non-interchangeable and use sensitive electromagnetic relays for overcurrent trip protection. Heat sensitive bimetals are used for thermal overcurrent protection. Short circuit current protection begins at 10 times the thermal rating of the breaker and uses a magnetic coil principle. ## Standards The UL489/CSA 22.2 version of Ts3 also carries an IEC-60947-2 rating. ## Versions To meet all application needs, the Ts3 is available in various versions: T =Thermal-magnetic D = Molded case switch M = Magnetic only (MCP) ## Performance level Each version is also available in different maximum fault interrupting levels N = Normal H = High L = Extra high ## Number of poles The Ts3 is available in two, three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. UL/CSA Interrupting capacity (kA RMS) UL489 / CSA C22.2 |Voltage|N|H|L| |---|---|---|---| |150AF, 15A-150A|||| |240 VAC|65|100|150| |480 VAC|25|50|851| |600 VAC|14|14|25| |500 VDC|35|50|65| |600 VDC|20|35|50| |225AF, 175A-225A|||| |240 VAC|65|100|150| |480 VAC|25|50|65| |600 VAC|–|–|–| |500 VDC|20|35|50| |600 VDC|–|–|–| |IEC-60947-2 Interrupting capacity (kA RMS)|||| |230 VAC|65|100|170| |415 VAC|35|65|85| |690 VAC|14|18|20| |750 VDC2|20|35|50| ## Molded case switches UL489 switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. 1 15-30A are 65kA at 480VAC 17.23 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Ts3 150A, 600V ∆, 225A, 480V ∆ Thermal magnetic ## Ts3 150A 600VAC/225A 480VAC Thermal Magnetic Trip Units |Breaker|IC at 480VAC kA|Rating|Magnetic<br>trip|2 pole,<br>600VAC/500VDC<br>catalognumber|3 pole, 600VAC/DC<br>catalog number| |---|---|---|---|---|---| |Ts3N||15A|500A|Ts3N015TW-2|Ts3N015TW| |||20A|500A|Ts3N020TW-2|Ts3N020TW| |||25A|500A|Ts3N025TW-2|Ts3N025TW| |||30A|500A|Ts3N030TW-2|Ts3N030TW| |||35A|500A|Ts3N035TW-2|Ts3N035TW| ||25|40A|500A|Ts3N040TW-2|Ts3N040TW| |||50A|500A|Ts3N050TW-2|Ts3N050TW| |||60A|600A|Ts3N060TW-2|Ts3N060TW| |||70A|700A|Ts3N070TW-2|Ts3N070TW| |||80A|800A|Ts3N080TW-2|Ts3N080TW| |||90A|900A|Ts3N090TW-2|Ts3N090TW| |||100A|1000A|Ts3N100TW-2|Ts3N100TW| |||125A|1250A|Ts3N125TW-2|Ts3N125TW| |||150A|1500A|Ts3N150TW-2|Ts3N150TW| ||||||| |Breaker|IC at 480VAC kA|Rating|Magnetic<br>trip|2 pole,<br>600VAC/500VDC<br>catalognumber|3 pole, 600VAC/DC<br>catalog number| |Ts3H||15A|500A|Ts3H015TW-2|Ts3H015TW| |||20A|500A|Ts3H020TW-2|Ts3H020TW| |||25A|500A|Ts3H025TW-2|Ts3H025TW| |||30A|500A|Ts3H030TW-2|Ts3H030TW| |||35A|500A|Ts3H035TW-2|Ts3H035TW| ||50|40A|500A|Ts3H040TW-2|Ts3H040TW| |||50A|500A|Ts3H050TW-2|Ts3H050TW| |||60A|600A|Ts3H060TW-2|Ts3H060TW| |||70A|700A|Ts3H070TW-2|Ts3H070TW| |||80A|800A|Ts3H080TW-2|Ts3H080TW| |||90A|900A|Ts3H090TW-2|Ts3H090TW| |||100A|1000A|Ts3H100TW-2|Ts3H100TW| |||125A|1250A|Ts3H125TW-2|Ts3H125TW| |||150A|1500A|Ts3H150TW-2|Ts3H150TW| ||||||| |Breaker|IC at 480VAC kA|Rating|Magnetic<br>trip|2 pole,<br>600VAC/500VDC<br>catalognumber|3 pole, 600VAC/DC<br>catalog number| |Ts3L||15A|500A|Ts3L015TW-2|Ts3L015TW| ||65|20A|500A|Ts3L020TW-2|Ts3L020TW| |||25A|500A|Ts3L025TW-2|Ts3L025TW| |||30A|500A|Ts3L030TW-2|Ts3L030TW| |||35A|500A|Ts3L035TW-2|Ts3L035TW| |||40A|500A|Ts3L040TW-2|Ts3L040TW| |||50A|500A|Ts3L050TW-2|Ts3L050TW| |||60A|600A|Ts3L060TW-2|Ts3L060TW| ||85|70A|700A|Ts3L070TW-2|Ts3L070TW| |||80A|800A|Ts3L080TW-2|Ts3L080TW| |||90A|900A|Ts3L090TW-2|Ts3L090TW| |||100A|1000A|Ts3L100TW-2|Ts3L100TW| |||125A|1250A|Ts3L125TW-2|Ts3L125TW| |||150A|1500A|Ts3L150TW-2|Ts3L150TW| NOTE: See pages 17.71 - 17.83 for electrical/mechanical accessories. 17.24 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Ts3 150A, 600V ∆, 225A, 480V ∆, 100% rated Thermal magnetic ## Ts3 ## 150A 600VAC/225A 480VAC Thermal Magnetic Trip Units 100% Rated |Breaker|IC at<br>480VAC|Rating|Magnetic<br>trip|3 pole 600VAC/DC<br>catalog number||Breaker|IC at<br>480VAC|Rating<br>Magnetic<br>trip<br>3 pole<br>catalognumber|Rating<br>Magnetic<br>trip<br>3 pole<br>catalognumber|Rating<br>Magnetic<br>trip<br>3 pole<br>catalognumber| |---|---|---|---|---|---|---|---|---|---|---| |Ts3NQ||15A|500A|Ts3NQ015TW||Ts3LQ|65kA|15A|500A|Ts3LQ015TW| |||20A|500A|Ts3NQ020TW||||20A|500A|Ts3LQ020TW| |||25A|500A|Ts3NQ025TW||||25A|500A|Ts3LQ025TW| |||30A|500A|Ts3NQ030TW||||30A|500A|Ts3LQ030TW| |||35A|500A|Ts3NQ035TW||||35A|500A|Ts3LQ035TW| |||40A|500A|Ts3NQ040TW|||85kA|40A|500A|Ts3LQ040TW| |||50A|500A|Ts3NQ050TW||||50A|500A|Ts3LQ050TW| ||25|60A|600A|Ts3NQ060TW||||60A|600A|Ts3LQ060TW| |||70A|700A|Ts3NQ070TW||||70A|700A|Ts3LQ070TW| |||80A|800A|Ts3NQ080TW||||80A|800A|Ts3LQ080TW| |||90A|900A|Ts3NQ090TW||||90A|900A|Ts3LQ090TW| |||100A|1000A|Ts3NQ100TW||||100A|1000A|Ts3LQ100TW| |||125A|1250A|Ts3NQ125TW||||125A|1250A|Ts3LQ125TW| |||150A|1500A|Ts3NQ150TW||||150A|1500A|Ts3LQ150TW| NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. |Breaker|IC at<br>480VAC|Rating|Magnetic<br>trip|3 pole<br>catalognumber| |---|---|---|---|---| |Ts3HQ||15A|500A|Ts3HQ015TW| |||20A|500A|Ts3HQ020TW| |||25A|500A|Ts3HQ025TW| |||30A|500A|Ts3HQ030TW| |||35A|500A|Ts3HQ035TW| |||40A|500A|Ts3HQ040TW| ||50kA|50A|500A|Ts3HQ050TW| |||60A|600A|Ts3HQ060TW| |||70A|700A|Ts3HQ070TW| |||80A|800A|Ts3HQ080TW| |||90A|900A|Ts3HQ090TW| |||100A|1000A|Ts3HQ100TW| |||125A|1250A|Ts3HQ125TW| |||150A|1500A|Ts3HQ150TW| 17.25 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## ## Ts3 150/225A 600VAC MCP/Molded case switch ## Magnetic only (MCP) **==> picture [392 x 173] intentionally omitted <==** **----- Start of picture text -----**<br> Breaker IC at 480VAC Trip unit type Rating Adjustment 3 pole 600VAC<br>range Catalog number<br>25 Magnetic only 3 12-36 Ts3L003MW<br>25 Magnetic only 5 20-60 Ts3L005MW<br>Ts3L 25 Magnetic only 10 40-120 Ts3L010MW<br>25 Magnetic only 25 100-300 Ts3L025MW<br>85 Magnetic only 50 200-600 Ts3L050MW<br>85 Magnetic only 100 400-1200 Ts3L100MW<br>85 Magnetic only 125 500-1500 Ts3L125MW<br>Ts3L 85 Magnetic only 150 600-1500 Ts3L150MW<br>65 Magnetic only 175 1 700-2100 Ts3L175MW<br>65 Magnetic only 200 1 800-2400 Ts3L200MW<br>Molded case switch 2<br>3 pole 600V<br>Type IC at 480V (2) Magnetic trip Amps<br>catalog number<br>50 1500 150 Ts3H150DW<br>Ts3H<br>50 2250 225 1 Ts3H225DW<br>**----- End of picture text -----**<br> NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 2 480 VAC maximum 1 When protected by a OCPD with appropriate ratings. 17.26 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage T4 250A, 600V ∆ Electronic and thermal magnetic 17 Dimensions 3P Fixed Version 8.07H x 4.13W x 4.07D Weight 6.18 (Ibs) T4 ## General The T4 breaker is a 250 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. ## Standards The UL489/CSA 22.2 version of T4 also carries an IEC-60947-2 rating. ## Versions ## UL489 / CSA C22.2 Interrupting capacity (kA RMS) |Voltage|N|S|H|L|V| |---|---|---|---|---|---| |240VAC|65|100|150|200|200| |480VAC|25|35|65|100|150| |600VAC|18|25|35|65|100| |500VDC1|25|35|50|65|100| |600VDC2|16|25|35|50|65| To meet all application requirements, the T4 is available in the following versions: - T = Thermal-magnetic - B = Selectable & adjustable LI or LS - C = Adjustable LSI - E = Adjustable LSIG - D = Molded Case Switch - E5 = Electronic instantaneous only (MCP) ## Trip functions These trip functions are available: - L = Long time ## IEC 60947-2 Interrupting capacity (kA RMS) |Voltage|N|S|H|L|V| |---|---|---|---|---|---| |230VAC|70|85|100|200|200| |415VAC|36|50|70|120|200| |690VAC|20|25|40|70|80| |750VDC2|16|25|36|50|70| - S = Short time - I = Instantaneous - G = Ground fault ## Performance levels Each version is also available in different maximum fault interrupting levels: - N = Normal - S = Standard - H = High - UL Current Limiting - L = Extra high - V = Very high - UL Current Limiting ## Number of poles 3 The T4 is available in two, three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. > 1 2 poles in series. > 2 3 poles in series. > 3 2 pole breakers available in N version only. 4 pole breakers available in N and H version only. 17.27 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T4 250A, 600V ∆ Adjustable thermal magnetic ## 20A - 250A Frame |Breaker|IC at<br>480VAC|Rating|Magnetic<br>trip|2 pole, 600VAC/600VDC<br>catalognumber|3 pole, 600VAC/600VDC<br>catalognumber| |---|---|---|---|---|---| |T4N||125A|625-1250|T4N125TW-2|T4N125TW| ||25|150A|750-1500|T4N150TW-2|T4N150TW| |||200A|1000-2000|T4N200TW-2|T4N200TW| |||250A|1250-2500|T4N250TW-2|T4N250TW| |T4S||125A|625-1250|–|T4S125TW| |||150A|750-1500|–|T4S150TW| ||35|200A|1000-2000|–|T4S200TW| |||250A|1250-2500|–|T4S250TW| |T4H<br>UL Current<br>Limiting|65|125A|625-1250|–|T4H125TW| |||150A|750-1500|–|T4H150TW| |||200A|1000-2000|–|T4H200TW| |||250A|1250-2500|–|T4H250TW| |T4L||125A|625-1250|–|T4L125TW| ||100|150A|750-1500|–|T4L150TW| |||200A|1000-2000|–|T4L200TW| |||250A|1250-2500|–|T4L250TW| |T4V<br>UL Current<br>Limiting||125A|625-1250|–|T4V125TW| ||10|150A|750-1500|–|T4V150TW| ||5|200A|1000-2000|–|T4V200TW| |||250A|1250-2500|–|T4V250TW| NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17.28 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## T4 250A, 600V ∆ 100% rated Adjustable thermal magnetic ## 30A - 250A Frame 100% rated |Breaker|IC at 480 VAC<br>kA|Rating|Magnetic<br>trip|3 pole,<br>600VAC/600VDC<br>Catalognumber| |---|---|---|---|---| |T4N|25|125A|625-1250|T4NQ125TW| |||150A|750-1500|T4NQ150TW| |||200A|1000-2000|T4NQ200TW| |||250A|1250-2500|T4NQ250TW| |T4S||125A|625-1250|T4SQ125TW| ||35|150A|750-1500|T4SQ150TW| |||200A|1000-2000|T4SQ200TW| |||250A|1250-2500|T4SQ250TW| |T4H<br>UL Current<br>Limiting||125A|625-1250|T4HQ125TW| |||150A|750-1500|T4HQ150TW| ||65|200A|1000-2000|T4HQ200TW| |||250A|1250-2500|T4HQ250TW| |T4L|100|125A|625-1250|T4LQ125TW| |||150A|750-1500|T4LQ150TW| |||200A|1000-2000|T4LQ200TW| |||250A|1250-2500|T4LQ250TW| |T4V<br>UL Current<br>Limiting||125A|625-1250|T4VQ125TW| ||150|150A|750-1500|T4VQ150TW| |||200A|1000-2000|T4VQ200TW| |||250A|1250-2500|T4VQ250TW| NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17.29 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T4 250A, 600V ∆ Electronic (AC only) ## 100A Frame, electronic trip unit (AC only) |100A Frame,|electronic trip u|nit (AC only)||| |---|---|---|---|---| |<br>Breaker|<br>IC at 480VAC<br>kA|<br>Trip<br>Unit|2 pole, 600V<br>catalognumber|3 pole, 600V<br>catalognumber| |T4N|25|PR221 LS/I|T4N100BW-2|T4N100BW| |||PR222 LSI|T4N100CW-2|T4N100CW| |||PR222 LSIG|T4N100EW-2|T4N100EW| |T4S||PR221 LS/I|-|T4S100BW| ||35|PR222 LSI|-|T4S100CW| |||PR222 LSIG|-|T4S100EW| |T4H<br>UL Current<br>Limiting|65|PR221 LS/I|-|T4H100BW| |||PR222 LSI|-|T4H100CW| |||PR222 LSIG|-|T4H100EW| |T4L||PR221 LS/I|-|T4L100BW| ||100|PR222 LSI|-|T4L100CW| |||PR222 LSIG|-|T4L100EW| |T4V<br>UL Current<br>Limiting|150|PR221 LS/I|-|T4V100BW| |||PR222 LSI|-|T4V100CW| |||PR222 LSIG|-|T4V100EW| ## 150A Frame, electronic trip unit (AC only) |150A Frame,|electronic trip u|nit (AC only)||| |---|---|---|---|---| |Breaker|<br>IC at 480VAC<br>kA|<br>Trip<br>Unit|2 pole, 600V<br>catalognumber|3 pole, 600V<br>catalognumber| |T4N||PR221 LS/I|T4N150BW-2|T4N150BW| ||25|PR222 LSI|T4N150CW-2|T4N150CW| |||PR222 LSIG|T4N150EW-2|T4N150EW| |T4S|35|PR221 LS/I|-|T4S150BW| |||PR222 LSI|-|T4S150CW| |||PR222 LSIG|-|T4S150EW| |T4H<br>UL Current<br>Limiting||PR221 LS/I|-|T4H150BW| ||65|PR222 LSI|-|T4H150CW| |||PR222 LSIG|-|T4H150EW| |T4L|100|PR221 LS/I|-|T4L150BW| |||PR222 LSI|-|T4L150CW| |||PR222 LSIG|-|T4L150EW| |T4V<br>UL Current<br>Limiting||PR221 LS/I|-|T4V150BW| ||150|PR222 LSI|-|T4V150CW| |||PR222 LSIG|-|T4V150EW| ## 250A Frame, electronic trip unit (AC only) |250A Frame,|electronic trip u|nit (AC only)||| |---|---|---|---|---| |<br>Breaker|<br>IC at 480VAC<br>kA|<br>Trip<br>Unit|2 pole, 600V<br>catalognumber|3 pole, 600V<br>catalognumber| |T4N||PR221 LS/I|T4N250BW-2|T4N250BW| ||25|PR222 LSI|T4N250CW-2|T4N250CW| |||PR222 LSIG|T4N250EW-2|T4N250EW| |T4S|35|PR221 LS/I|-|T4S250BW| |||PR222 LSI|-|T4S250CW| |||PR222 LSIG|-|T4S250EW| |T4H<br>UL Current<br>Limiting||PR221 LS/I|-|T4H250BW| ||65|PR222 LSI|-|T4H250CW| |||PR222 LSIG|-|T4H250EW| |T4L|100|PR221 LS/I|-|T4L250BW| |||PR222 LSI|-|T4L250CW| |||PR222 LSIG|-|T4L250EW| |T4V<br>UL Current<br>Limiting||PR221 LS/I|-|T4V250BW| ||150|PR222 LSI|-|T4V250CW| |||PR222 LSIG|-|T4V250EW| NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17.30 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## T4 250A, 600V ∆, 100% Rated Electronic (AC only) ## 100A Frame - 100% rated, electronic trip unit (AC only) |Breaker|IC at 480VAC<br>kA|Trip<br>Unit|3 pole, 600V<br>catalognumber| |---|---|---|---| |T4N|25|PR221 LS/I|T4NQ100BW| |||PR222 LSI|T4NQ100CW| |||PR222 LSIG|T4NQ100EW| |T4S||PR221 LS/I|T4SQ100BW| ||35|PR222 LSI|T4SQ100CW| |||PR222 LSIG|T4SQ100EW| |T4H<br>UL Current<br>Limiting|65|PR221 LS/I|T4HQ100BW| |||PR222 LSI|T4HQ100CW| |||PR222 LSIG|T4HQ100EW| |T4L||PR221 LS/I|T4LQ100BW| ||100|PR222 LSI|T4LQ100CW| |||PR222 LSIG|T4LQ100EW| |T4V<br>UL Current<br>Limiting|150|PR221 LS/I|T4VQ100BW| |||PR222 LSI|T4VQ100CW| |||PR222 LSIG|T4VQ100EW| ## 250A Frame - 100% rated, electronic trip unit (AC only) |250A Frame -|100% rated, elec|tronic trip unit (|AC only)| |---|---|---|---| |Breaker|IC at 480VAC<br>kA|Trip<br>Unit|3 pole, 600V<br>catalognumber| |T4N|25|PR221 LS/I|T4NQ250BW| |||PR222 LSI|T4NQ250CW| |||PR222 LSIG|T4NQ250EW| |T4S||PR221 LS/I|T4SQ250BW| ||35|PR222 LSI|T4SQ250CW| |||PR222 LSIG|T4SQ250EW| |T4H<br>UL Current<br>Limiting|65|PR221 LS/I|T4HQ250BW| |||PR222 LSI|T4HQ250CW| |||PR222 LSIG|T4HQ250EW| |T4L||PR221 LS/I|T4LQ250BW| ||100|PR222 LSI|T4LQ250CW| |||PR222 LSIG|T4LQ250EW| |T4V<br>UL Current<br>Limiting|150|PR221 LS/I|T4VQ250BW| |||PR222 LSI|T4VQ250CW| |||PR222 LSIG|T4VQ250EW| NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. ## 150A Frame - 100% rated, electronic trip unit (AC only) |Breaker|IC at 480VAC<br>kA|Trip<br>Unit|3 pole, 600V<br>catalognumber| |---|---|---|---| |T4N||PR221 LS/I|T4NQ150BW| ||25|PR222 LSI|T4NQ150CW| |||PR222 LSIG|T4NQ150EW| |T4S|35|PR221 LS/I|T4SQ150BW| |||PR222 LSI|T4SQ150CW| |||PR222 LSIG|T4SQ150EW| |T4H<br>UL Current<br>Limiting||PR221 LS/I|T4HQ150BW| ||65|PR222 LSI|T4HQ150CW| |||PR222 LSIG|T4HQ150EW| |T4L|100|PR221 LS/I|T4LQ150BW| |||PR222 LSI|T4LQ150CW| |||PR222 LSIG|T4LQ150EW| |T4V<br>UL Current<br>Limiting||PR221 LS/I|T4VQ150BW| ||150|PR222 LSI|T4VQ150CW| |||PR222 LSIG|T4VQ150EW| 17.31 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A ## T4 250A, 600V ∆ Instantaneous only, MCP/Molded case switch ## Instantaneous only MCPs ## T4 - 250A Frame magnetic only (MCP - AC only) |T4 -250A|Frame mag|netic only (M|CP - AC o|nly)|| |---|---|---|---|---|---| |Breaker|IC at 480VAC|Trip unit type|Rating|Adjustment range|3 pole, 600VAC<br>Catalog number| |T4N|||100A|100-1000|T4N100E5W| ||25kA|Instantaneous<br>only|150A|150-1500|T4N150E5W| ||||250A|250-2500|T4N250E5W| |T4S|35kA|Instantaneous<br>only|100A|100-1000|T4S100E5W| ||||150A|150-1500|T4S150E5W| ||||250A|250-2500|T4S250E5W| |T4H|||100A|100-1000|T4H100E5W| ||65kA|Instantaneous<br>only|150A|150-1500|T4H150E5W| ||||250A|250-2500|T4H250E5W| |T4L|100kA|Instantaneous<br>only|100A|100-1000|T4L100E5W| ||||150A|150-1500|T4L150E5W| ||||250A|250-2500|T4L250E5W| ## Molded case switch 1 **==> picture [307 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> Type IC at 480VAC Amps Magnetictrip catalo3 pole 600Vg number<br>T4N-D 25kA 250 3000 T4N250DW<br>T4S-D 35kA 250 3000 T4S250DW<br>T4H-D 65kA 250 3000 T4H250DW<br>T4L-D 100kA 250 3000 T4L250DW<br>T4V-D 150kA 250 3000 T4V250DW<br>**----- End of picture text -----**<br> NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 1 When protected by a OCPD with appropriate ratings. 17.32 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## T5 400/600A, 600V ∆ Electronic and thermal magnetic Dimensions 3P Fixed Version 8.07H x 5.51W x 4.07D Weight 8.55 (Ibs) T5 ## General The T5 breaker is a 400/600 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. 3 ## Standards The UL489/CSA 22.2 version of T5 also carries an IEC-60947-2 rating. ## Versions To meet all application requirements, the T5 is available in the following versions: ## UL489 / CSA C22.2 Interrupting capacity (kA RMS) |Voltage|N|S|H|L|V| |---|---|---|---|---|---| |240VAC|65|100|150|200|200| |480VAC|25|35|65|100|150| |600VAC|18|25|35|65|100| |500VDC1|25|35|50|65|100| |600VDC2|16|25|35|50|65| - T = Thermal-magnetic - B = Selectable & adjustable LI or LS - C = Adjustable LSI - E = Adjustable LSIG - D = Molded Case Switch - E5 = Electronic instantaneous only (MCP) ## Trip functions These trip functions are available: L = Long time ## IEC 60947-2 Interrupting capacity (kA RMS) |Voltage|N|S|H|L|V| |---|---|---|---|---|---| |Voltage|N|S|H|L|V| |230VAC|70|85|100|200|200| |415VAC|36|50|70|120|200| |690VAC|20|25|40|70|80| |750VDC2|16|25|36|50|70| S = Short time - I = Instantaneous - G = Ground fault ## Performance levels Each version is also available in different maximum fault interrupting levels: - N = Normal - S = Standard - H = High - UL Current Limiting - L = Extra high - V = Very high - UL Current Limiting ## Number of poles 4 The T5 is available in two, three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. > 1 2 poles in series. > 2 3 poles in series. > 3 T5 600A not available with thermal magnetic trip unit. > 4 2 pole available in N version only. 4 pole available in N and H version only. 17.33 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A ## T5 400/600A, 600V ∆ Thermal magnetic 1 ## 300A - 400A Frames - thermal-magnetic trip units |Breaker|<br>IC at 480VAC<br>kA|<br>Rating|<br>Magnetic<br>trip|2 pole, 600VAC/500VDC<br>catalognumber|3 pole, 600VAC/600VDC<br>catalognumber| |---|---|---|---|---|---| |T5N|25|300A|1500-3000|T5N300TW-2|T5N300TW| |||400A|2000-4000|T5N400TW-2|T5N400TW| |T5S|35|300A|1500-3000||T5S300TW| |||400A|2000-4000|–|T5S400TW| |T5H<br>UL Current Limiting|65|300A|1500-3000||T5H300TW| |||400A|2000-4000|–|T5H400TW| |T5L|100|300A|1500-3000||T5L300TW| |||400A|2000-4000|–|T5L400TW| |T5V<br>UL Current Limiting|150|300A|1500-3000||T5V300TW| |||400A|2000-4000|–|T5V400TW| ## 300A - 400A Frames - 100% rated, thermal-magnetic |Breaker|IC at 480VAC|Rating|Magnetic<br>trip|3 pole, 600VAC/600VDC<br>Catalog number| |---|---|---|---|---| |T5N|25|300A|1500-3000|T5NQ300TW| |||400A|2000-4000|T5NQ400TW| |T5S|35|300A|1500-3000|T5SQ300TW| |||400A|2000-4000|T5SQ400TW| |T5H<br>UL Current Limiting|65|300A|1500-3000|T5HQ300TW| |||400A|2000-4000|T5HQ400TW| |T5L|100|300A|1500-3000|T5LQ300TW| |||400A|2000-4000|T5LQ400TW| |T5V<br>UL Current Limiting|150|300A|1500-3000|T5VQ300TW| |||400A|2000-4000|T5VQ400TW| NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 > 1 T5 600A not available with Thermal Magnetic trip unit. 17.34 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## T5 400/600A, 600V ∆ Electronic (AC only) ## 300A Frame, electronic trip unit (AC only) |300A Frame,|electronic trip|unit (AC only)||| |---|---|---|---|---| |<br>Breaker|<br>IC at 480VAC<br>kA|<br>Trip<br>Unit|2 pole, 600V<br>catalognumber|3 pole, 600V<br>catalognumber| |T5N|25|PR221 LS/I|T5N300BW-2|T5N300BW| |||PR222 LSI|T5N300CW-2|T5N300CW| |||PR222 LSIG|T5N300EW-2|T5N300EW| |T5S||PR221 LS/I|-|T5S300BW| ||35|PR222 LSI|-|T5S300CW| |||PR222 LSIG|-|T5S300EW| |T5H<br>UL Current<br>Limiting|65|PR221 LS/I|-|T5H300BW| |||PR222 LSI|-|T5H300CW| |||PR222 LSIG|-|T5H300EW| |T5L||PR221 LS/I|-|T5L300BW| ||100|PR222 LSI|-|T5L300CW| |||PR222 LSIG|-|T5L300EW| |T5V<br>UL Current<br>Limiting|150|PR221 LS/I|-|T5V300BW| |||PR222 LSI|-|T5V300CW| |||PR222 LSIG|-|T5V300EW| ## 400A Frame, electronic trip unit (AC only) |400A Frame,|electronic trip|unit (AC only)||| |---|---|---|---|---| |<br>Breaker|<br>IC at 480VAC<br>kA|<br>Trip<br>Unit|2 pole, 600V<br>catalognumber|3 pole, 600V<br>catalognumber| |T5N|25|PR221 LS/I|T5N400BW-2|T5N400BW| |||PR222 LSI|T5N400CW-2|T5N400CW| |||PR222 LSIG|T5N400EW-2|T5N400EW| |T5S||PR221 LS/I|-|T5S400BW| ||35|PR222 LSI|-|T5S400CW| |||PR222 LSIG|-|T5S400EW| |T5H<br>UL Current<br>Limiting||PR221 LS/I|-|T5H400BW| ||65|PR222 LSI|-|T5H400CW| |||PR222 LSIG|-|T5H400EW| |T5L|100|PR221 LS/I|-|T5L400BW| |||PR222 LSI|-|T5L400CW| |||PR222 LSIG|-|T5L400EW| |T5V<br>UL Current<br>Limiting|150|PR221 LS/I|-|T5V400BW| |||PR222 LSI|-|T5V400CW| |||PR222 LSIG|-|T5V400EW| ## 600A Frame, electronic trip unit (AC only) 1 |600A Frame,e|lectronic trip u|nit (AC only) 1|| |---|---|---|---| |<br>Breaker|<br>IC at 480VAC<br>kA|<br>Trip<br>Unit|3 pole, 600V<br>catalognumber| |T5N|25|PR221 LS/I|T5N600BW| |||PR222 LSI|T5N600CW| |||PR222 LSIG|T5N600EW| |T5S|35|PR221 LS/I|T5S600BW| |||PR222 LSI|T5S600CW| |||PR222 LSIG|T5S600EW| |T5H||PR221 LS/I|T5H600BW| ||65|PR222 LSI|T5H600CW| |||PR222 LSIG|T5H600EW| |T5L||PR221 LS/I|T5L600BW| ||100|PR222 LSI|T5L600CW| |||PR222 LSIG|T5L600EW| |T5V|150|PR221 LS/I|T5V600BW| |||PR222 LSI|T5V600CW| |||PR222 LSIG|T5V600EW| NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 1 T5 600A not available in 2 pole version. 17.35 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A ## T5 400/600A, 600V ∆, 100% Rated 1 Electronic (AC only) ## 300A Frame – 100% rated, electronic trip units (AC only) |Breaker|IC at 480VAC<br>kA|Trip<br>Unit|3 pole, 600V<br>catalognumber| |---|---|---|---| |T5N|25|PR221 LS/I|T5NQ300BW| |||PR222 LSI|T5NQ300CW| |||PR222 LSIG|T5NQ300EW| |T5S||PR221 LS/I|T5SQ300BW| ||35|PR222 LSI|T5SQ300CW| |||PR222 LSIG|T5SQ300EW| |T5H<br>UL Current<br>limiting|65|PR221 LS/I|T5HQ300BW| |||PR222 LSI|T5HQ300CW| |||PR222 LSIG|T5HQ300EW| |T5L||PR221 LS/I|T5LQ300BW| ||100|PR222 LSI|T5LQ300CW| |||PR222 LSIG|T5LQ300EW| |T5V<br>UL Current<br>limiting|150|PR221 LS/I|T5VQ300BW| |||PR222 LSI|T5VQ300CW| |||PR222 LSIG|T5VQ300EW| ## 400A Frame – 100% rated, electronic trip units (AC only) |Breaker|IC at 480VAC<br>kA|Trip<br>Unit|3 pole, 600V<br>catalognumber| |---|---|---|---| |T5N||PR221 LS/I|T5NQ400BW| ||25|PR222 LSI|T5NQ400CW| |||PR222 LSIG|T5NQ400EW| |T5S|35|PR221 LS/I|T5SQ400BW| |||PR222 LSI|T5SQ400CW| |||PR222 LSIG|T5SQ400EW| |T5H<br>UL Current<br>limiting||PR221 LS/I|T5HQ400BW| ||65|PR222 LSI|T5HQ400CW| |||PR222 LSIG|T5HQ400EW| |T5L|100|PR221 LS/I|T5LQ400BW| |||PR222 LSI|T5LQ400CW| |||PR222 LSIG|T5LQ400EW| |T5V<br>UL Current<br>limiting||PR221 LS/I|T5VQ400BW| ||150|PR222 LSI|T5VQ400CW| |||PR222 LSIG|T5VQ400EW| NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 1 T5 600A not available in 100% rated frame. 17.36 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## T5 400/600A, 600V ∆ Instantaneous only, MCP/Molded case switch ## T5 - 400A Frame, magnetic only (MCP - AC only) |Breaker|IC at 480VAC|Trip unit type|Rating|Adjustment<br>range|3 pole, 600VAC<br>Catalog number| |---|---|---|---|---|---| |T5N||Instantaneous|300A|300-3000|T5N300E5W| ||25kA|only|400A|400-4000|T5N400E5W| |T5S|35kA|Instantaneous<br>only|300A|300-3000|T5S300E5W| ||||400A|400-4000|T5S400E5W| |T5H|65kA|Instantaneous<br>only|300A|300-3000|T5H300E5W| ||||400A|400-4000|T5H400E5W| |T5L||Instantaneous|300A|300-3000|T5L300E5W| ||100kA|only|400A|400-4000|T5L400E5W| ## T5 - 600A Frame, magnetic only (MCP - AC only) |Breaker|IC at 480VAC|Trip unit type|Rating|Adjustment<br>range|3 pole, 600VAC<br>Catalog number| |---|---|---|---|---|---| |T5N|25kA|Instantaneous<br>only|600A|600-6000|T5N600E5W| |T5S|35kA|Instantaneous<br>only|600A|600-6000|T5S600E5W| |T5H|65kA|Instantaneous<br>only|600A|600-6000|T5H600E5W| |T5L|100kA|Instantaneous<br>only|600A|600-6000|T5L600E5W| ## Molded case switch 1 **==> picture [322 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> Type IC at 480VAC Amps Magnetictrip catalo3 pole 600Vg number<br>T5N-D 25kA 400 5000 T5N400DW<br>T5S-D 35kA 400 5000 T5S400DW<br>T5H-D 65kA 400 5000 T5H400DW<br>T5L-D 100kA 400 5000 T5L400DW<br>T5V-D 150kA 400 5000 T5V400DW<br>T5N-D 25kA 600 6000 T5N600DW<br>T5S-D 35kA 600 6000 T5S600DW<br>T5H-D 65kA 600 6000 T5H600DW<br>T5L-D 100kA 600 6000 T5L600DW<br>T5V-D 150kA 600 6000 T5V600DW<br>**----- End of picture text -----**<br> NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. > 1 When protected by a OCPD with appropriate ratings. 17.37 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A **==> picture [37 x 33] intentionally omitted <==** **----- Start of picture text -----**<br> Tmax<br>MCCBs<br>**----- End of picture text -----**<br> ## T6 600A, 800A, 600V ∆ Thermal magnetic and electronic Dimensions 3P Fixed Version 10.55H x 8.26W x 4.07D Weight 20.9 (Ibs) Weight T6 ## General The T6 breaker is an 800 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. The T6 is available as a 600 or 800A frame. ## Standards The UL489/CSA 22.2 version of T6 also carries an IEC-60947-2 rating. ## Versions ## UL489 / CSA C22.2 Interrupting capacity (kA RMS) |Voltage|N|S|H|L| |---|---|---|---|---| |240VAC|65|100|200|200| |480VAC|35|50|65|100| |600VAC|20|25|35|42| |500VDC1|35|35|50|65| |600VDC2|20|20|35|50| To meet all application requirements, the T6 is available in the following versions: - T = Thermal-magnetic, fixed - B = Selectable & adjustable LI or LS - C = Adjustable LSI - E = Adjustable LSIG - D = Molded Case Switch - E5 = Electronic instantaneous only (MCP) ## Trip functions ## IEC 60947-2 Interrupting capacity (kA RMS) |Voltage|N|S|H|L| |---|---|---|---|---| |230VAC|70|85|100|200| |415VAC|36|50|70|100| |690VAC|20|22|25|30| |750VDC2|16|20|36|50| These trip functions are available: L = Long time - S = Short time - I = Instantaneous - G = Ground fault ## Performance levels Each version is also available in different maximum fault interrupting levels: N = Normal - S = Standard - H = High - L = Extra high 17 Number of poles 3 The T6 is available as a three and four pole breaker. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. > 2 3 poles in series. > 3 4 pole available N and H version only. 1 2 poles in series. 17.38 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## T6 600A, 800A, 600V ∆ Thermal magnetic and electronic T6 T6 600A, 600V Electronic Trip Units 600A, 800A, 600V Thermal Magnetic Trip Units **==> picture [528 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> Breaker IC at 480 VAC kA Rating Magnetic trip 3 pole, 600VAC/600VDC catalog number Breaker 480VACIC at Trip type Adjustment 3 pole, 600VAC catalog number<br>PR221 LS/I T6N600BW<br>T6N 35 600A 3000 - 6000A T6N600TW T6N 35 PR222 LSI T6N600CW<br>800A 4000 - 8000A T6N800TW PR222 LSIG T6N600EW<br>T6S 50 600A 3000 - 6000A T6S600TW PR221 LS/I T6S600BW<br>800A 4000 - 8000A T6S800TW T6S 50 PR222 LSI T6S600CW<br>T6H 65 600A 3000 - 6000A T6H600TW PR222 LSIG T6S600EW<br>800A 4000 - 8000A T6H800TW PR221 LS/I T6H600BW<br>T6L 100 600A 3000 - 6000A T6L600TW T6H 65 PR222 LSI T6H600CW<br>800A 4000 - 8000A T6L800TW PR222 LSIG T6H600EW<br>PR221 LS/I T6L600BW<br>T6 T6L 100 PR222 LSI T6L600CW<br>600A, 800A, 600V PR222 LSIG T6L600EW<br>**----- End of picture text -----**<br> 600A, 800A, 600V Thermal Magnetic Trip Units 100% rated |<br>Breaker|<br>IC at 480<br>VAC kA|<br>Rating|<br>Magnetic trip|3 pole, 600VAC/600VDC<br>catalog number| |---|---|---|---|---| |T6N|35|600A|3000 - 6000A|<br>T6NQ600TW| |||800A|4000 - 8000A|T6NQ800TW| |T6S||600A|3000 - 6000A|T6SQ600TW| ||50|800A|4000 - 8000A|T6SQ800TW| |T6H|65|600A|3000 - 6000A|T6HQ600TW| |||800A|4000 - 8000A|T6HQ800TW| |T6L|100|600A|3000 - 6000A|T6LQ600TW| |||800A|4000 - 8000A|T6LQ800TW| T6 800A, 600V Electronic Trip Units |Breaker|IC at<br>480VAC|Trip type|Adjustment|3 pole, 600VAC catalog<br>number| |---|---|---|---|---| |T6N||PR221|LS/I|T6N800BW| ||35|PR222|LSI|T6N800CW| |||PR222|LSIG|T6N800EW| |T6S|50|PR221|LS/I|T6S800BW| |||PR222|LSI|T6S800CW| |||PR222|LSIG|T6S800EW| |T6H||PR221|LS/I|T6H800BW| ||65|PR222|LSI|T6H800CW| |||PR222|LSIG|T6H800EW| |T6L|100|PR221|LS/I|T6L800BW| |||PR222|LSI|T6L800CW| |||PR222|LSIG|T6L800EW| NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17.39 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## ## T6 600A, 800A, 600V ∆ Thermal magnetic and electronic ## T6 **==> picture [253 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> T6<br>600A, 600V ∆<br>Electronic Trip Units Instantaneous Only<br>Breaker IC at 480VAC kA Trip type Adjustment RangeRangegee 3 pole, 600VAC catalog numbercatalog numberg number number<br>T6N 35 PR221 600-6000 T6N600E5W<br>T6S 50 PR221 600-6000 T6S600E5W<br>T6H 65 PR221 600-6000 T6H600E5W<br>T6L 100 PR221 600-6000 T6L600E5W<br>**----- End of picture text -----**<br> 600A, 600V ∆ Electronic Trip Units 100% Rated **==> picture [529 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> Breaker IC at 480VAC Trip type Adjustment 3 pole, 600VAC catalog number Breaker IC at 480VAC kA Trip type Adjustment RangeRangegee 3 pole, 600VAC catalog numbercatalog numberg number number<br>PR221 LS/I T6NQ600BW T6N 35 PR221 600-6000 T6N600E5W<br>T6N 35 PR222 LSI T6NQ600CW T6S 50 PR221 600-6000 T6S600E5W<br>PR222 LSIG T6NQ600EW T6H 65 PR221 600-6000 T6H600E5W<br>PR221 LS/I T6SQ600BW T6L 100 PR221 600-6000 T6L600E5W<br>T6S 50 PR222 LSI T6SQ600CW<br>PR222 LSIG T6SQ600EW<br>PR221 LS/I T6HQ600BW T6<br>T6H 65 PR222 LSI T6HQ600CW 800A, 600V<br>PR222 LSIG T6HQ600EW Electronic Trip Units Instantaneous Only<br>T6L 100 PR221PR222 LS/ILSI T6LQ600CWT6LQ600BW Breaker IC at 480VAC kA Trip type Adjustment Range 3 pole, 600VAC catalog number<br>PR222 LSIG T6LQ600EW T6N 35 PR221 800-8000 T6N800E5W<br>T6S 50 PR221 800-8000 T6S800E5W<br>T6H 65 PR221 800-8000 T6H800E5W<br>T6 T6L 100 PR221 800-8000 T6L800E5W<br>**----- End of picture text -----**<br> 800A, 600V Electronic Trip Units 100% Rated |<br>Breaker|<br>IC at 480VAC|<br>Trip type|<br>Adjustment|3 pole, 600VAC<br>catalog number||T6<br>800A, 600V<br>Molded Case Switch<br>Breaker<br>IC at 480VAC1<br>Amp<br>Magnetic Trip<br>3 pole, 600VAC<br>catalognumber|T6<br>800A, 600V<br>Molded Case Switch<br>Breaker<br>IC at 480VAC1<br>Amp<br>Magnetic Trip<br>3 pole, 600VAC<br>catalognumber|T6<br>800A, 600V<br>Molded Case Switch<br>Breaker<br>IC at 480VAC1<br>Amp<br>Magnetic Trip<br>3 pole, 600VAC<br>catalognumber|T6<br>800A, 600V<br>Molded Case Switch<br>Breaker<br>IC at 480VAC1<br>Amp<br>Magnetic Trip<br>3 pole, 600VAC<br>catalognumber|T6<br>800A, 600V<br>Molded Case Switch<br>Breaker<br>IC at 480VAC1<br>Amp<br>Magnetic Trip<br>3 pole, 600VAC<br>catalognumber| |---|---|---|---|---|---|---|---|---|---|---| |T6N||PR221|LS/I|<br>T6NQ800BW||||||| ||35|PR222|LSI|T6NQ800CW||||||| |||PR222|LSIG|T6NQ800EW||||||| |T6S|50|PR221|LS/I|T6SQ800BW||T6H|65|800|10,000|T6H800DW| |||PR222|LSI|T6SQ800CW||||||| |||PR222|LSIG|T6SQ800EW||||||| |T6H|65|PR221|LS/I|T6HQ800BW||||||| |||PR222|LSI|T6HQ800CW||||||| |||PR222|LSIG|T6HQ800EW||||||| |T6L||PR221|LS/I|T6LQ800BW||||||| ||100|PR222|LSI|T6LQ800CW||||||| |||PR222|LSIG|T6LQ800EW||||||| 1 When protected by a OCPD with appropriate ratings. 17.40 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A T7 (Toggle) 1000A, 1200A, 600V ∆ Electronic 17 Dimensions 3P Fixed Version 10.55H x 8.26W x 6.06D Weight 21.4 (Ibs) T7 ## General The T7 breaker is a 1200 amp frame with a microprocessor based over current protective trip system. ## Standards The UL489/CSA 22.2 version of T7 also carries an IEC-60947-2 rating. UL489 / CSA C22.2 Interrupting capacity (kA RMS) |Voltage|S|H|L| |---|---|---|---| |240VAC|65|100|150| |480VAC|50|65|100| |600VAC|25|50|65| ## Versions To meet all application requirements, the T7 is available in the following versions: - B = Selectable & adjustable LI or LS — Dip switch settings - C = Adjustable LSI — Dip switch settings - E = Adjustable LSIG — Dip switch settings - D = Molded Case Switch - P = LI — LCD display R = LSI — LCD display ## IEC 60947-2 Interrupting capacity (kA RMS) |Voltage|S|H|L| |---|---|---|---| |230VAC|85|100|200| |415VAC|50|70|120| |690VAC|30|42|50| S = LSIG — LCD display ## Trip functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault ## Performance levels Each version is also available in different maximum fault interrupting levels: S = Standard H = High L = Extra high ## Number of poles 1 The T7 is available as a 3 and 4 pole breaker. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. 1 4 Pole available S, H and L version. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17.41 1SXU000023C0202 Rev. A ## T7 1000A, 1200A, 600V ∆ Electronic ## T7S, 1000A, 600V Electronic |Electronic||||| |---|---|---|---|---| |Breaker|IC at<br>480VAC<br>kA|Trip type|Adjustment|3 pole, 600VAC catalog<br>number| |T7S||PR231/P|LS/I|T7S1000BW| |||PR232/P|LSI|T7S1000CW| ||50|PR331/P|LSIG|T7S1000EW| |||PR332/P|LI|T7S1000PW| |||PR332/P|LSI|T7S1000RW| |||PR332/P|LSIG|T7S1000SW| ## T7S, 1200A, 600V Electronic |Electronic||||| |---|---|---|---|---| |Breaker|IC at<br>480VAC kA|<br>Trip type|Adjustment|3 pole, 600VAC catalog<br>number| |T7S||PR231/P|LS/I|T7S1200BW| |||PR232/P|LSI|T7S1200CW| ||50|PR331/P|LSIG|T7S1200EW| |||PR332/P|LI|T7S1200PW| |||PR332/P|LSI|T7S1200RW| |||PR332/P|LSIG|T7S1200SW| ## T7H, 1000A, 600V Electronic |Electronic||||| |---|---|---|---|---| |Breaker|IC at<br>480VAC kA|<br>Trip type|Adjustment|3 pole, 600VAC catalog<br>number| |T7H||PR231/P|LS/I|T7H1000BW| |||PR232/P|LSI|T7H1000CW| |||PR331/P|LSIG|T7H1000EW| ||65|PR332/P|LI|T7H1000PW| |||PR332/P|LSI|T7H1000RW| |||PR332/P|LSIG|T7H1000SW| T7H, 1200A, 600V Electronic |Electronic||||| |---|---|---|---|---| |Breaker|IC at<br>480VAC kA|<br>Trip type|Adjustment|3 pole, 600VAC catalog<br>number| |T7H|65|PR231/P|LS/I|T7H1200BW| |||PR232/P|LSI|T7H1200CW| |||PR331/P|LSIG|T7H1200EW| |||PR332/P|LI|T7H1200PW| |||PR332/P|LSI|T7H1200RW| |||PR332/P|LSIG|T7H1200SW| |T7L, 1000A, 600V<br>Electronic<br>Breaker<br>IC at<br>480VAC<br>kA|T7L, 1000A, 600V<br>Electronic<br>Breaker<br>IC at<br>480VAC<br>kA|||| |---|---|---|---|---| ||IC at<br>480VAC<br>kA|Trip type|Adjustment|3 pole, 600VAC catalog<br>number| |T7L||PR231/P|LS/I|T7L1000BW| |||PR232/P|LSI|T7L1000CW| |||PR331/P|LSIG|T7L1000EW| ||100|PR332/P|LI|T7L1000PW| |||PR332/P|LSI|T7L1000RW| |||PR332/P|LSIG|T7L1000SW| T7L, 1200A, 600V Electronic |Electronic||||| |---|---|---|---|---| |Breaker|IC at<br>480VAC kA|Trip type|Adjustment|3 pole, 600VAC catalog<br>number| |T7L||PR231/P|LS/I|T7L1200BW| |||PR232/P|LSI|T7L1200CW| |||PR331/P|LSIG|T7L1200EW| ||100|PR332/P|LI|T7L1200PW| |||PR332/P|LSI|T7L1200RW| |||PR332/P|LSIG|T7L1200SW| NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 17.42 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## T7 1000A, 1200A, 600V ∆ Electronic, 100% rated **==> picture [528 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> T7S, 1000A, 600V T7L, 1000A, 600V<br>Electronic, 100% rated Electronic, 100% rated<br>Breaker IC at 480VAC kA Trip type Adjustment 3 pole, 600VAC Catalog number Breaker IC at 480VAC kA Trip type Adjustment 3 pole, 600VAC Catalog number<br>PR231/P LS/I T7SQ1000BW PR231/P LS/I T7LQ1000BW<br>PR232/P LSI T7SQ1000CW PR232/P LSI T7LQ1000CW<br>PR331/P LSIG T7SQ1000EW PR331/P LSIG T7LQ1000EW<br>T7S 50 T7L 100<br>PR332/P LI T7SQ1000PW PR332/P LI T7LQ1000PW<br>PR332/P LSI T7SQ1000RW PR332/P LSI T7LQ1000RW<br>PR332/P LSIG T7SQ1000SW PR332/P LSIG T7LQ1000SW<br>**----- End of picture text -----**<br> T7S, 1200A, 600V Electronic, 100% rated |,<br>Breaker|<br>IC at 480VAC<br>kA|<br> <br>Trip type|Adjustment|3 pole, 600VAC Catalog<br>number| |---|---|---|---|---| |T7S||PR231/P|LS/I|T7SQ1200BW| |||PR232/P|LSI|T7SQ1200CW| ||50|PR331/P|LSIG|T7SQ1200EW| |||PR332/P|LI|T7SQ1200PW| |||PR332/P|LSI|T7SQ1200RW| |||PR332/P|LSIG|T7SQ1200SW| ## T7L, 1200A, 600V ## Electronic, 100% rated |,<br>Breaker|<br>IC at 480VAC<br>kA|<br> <br>Trip type|Adjustment|3 pole, 600VAC Catalog<br>number| |---|---|---|---|---| |||PR231/P|LS/I|T7LQ1200BW| |||PR232/P|LSI|T7LQ1200CW| |T7L|100|PR331/P|LSIG|T7LQ1200EW| |||PR332/P|LI|T7LQ1200PW| |||PR332/P|LSI|T7LQ1200RW| |||PR332/P|LSIG|T7LQ1200SW| NOTE: See pages 17.71 - 17.83 for electrical/mechanical accessories. T7H, 1000A, 600V Electronic, 100% rated |,<br>Breaker|<br>IC at 480VAC<br>kA|<br> <br>Trip type|Adjustment|3 pole, 600VAC Catalog<br>number| |---|---|---|---|---| |T7H||PR231/P|LS/I|T7HQ1000BW| |||PR232/P|LSI|T7HQ1000CW| |||PR331/P|LSIG|T7HQ1000EW| ||65|PR332/P|LI|T7HQ1000PW| |||PR332/P|LSI|T7HQ1000RW| |||PR332/P|LSIG|T7HQ1000SW| T7H, 1200A, 600V Electronic, 100% rated |,<br>Breaker|<br>IC at 480VAC<br>kA|<br> <br>Trip type|Adjustment|3 pole, 600VAC Catalog<br>number| |---|---|---|---|---| |T7H||PR231/P|LS/I|T7HQ1200BW| |||PR232/P|LSI|T7HQ1200CW| |||PR331/P|LSIG|T7HQ1200EW| ||65|PR332/P|LI|T7HQ1200PW| |||PR332/P|LSI|T7HQ1200RW| |||PR332/P|LSIG|T7HQ1200SW| 17.43 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T7 1200A, 600V ∆ Electronic/Molded case switch T7 1200A, 600V Molded case switch |Breaker|IC at<br>480VAC kA1|Amp|Magnetic<br>trip|3 pole, 600VAC<br>Catalog number| |---|---|---|---|---| |T7H|-|1200|20,000|<br>T7H1200DW| NOTE: See pages 17.67 - 17.79 for electrical/mechanical accessories. T7 1000 - 1200A, 600V Motor circuit protection Electronic trip, instantaneous only **==> picture [257 x 83] intentionally omitted <==** **----- Start of picture text -----**<br> Breaker IC at 480VAC kA 1 Amp Catalog number<br>T7S 50 1000 T7S1000E5W<br>T7H 65 1000 T7H1000E5W<br>T7L 100 1000 T7L1000E5W<br>T7S 50 1200 T7S1200E5W<br>T7H 65 1200 T7H1200E5W<br>T7L 100 1200 T7L1200E5W<br>**----- End of picture text -----**<br> NOTE: See pages 17.71 - 17.83 for electrical/mechanical accessories. 1 When protected by a OCPD with appropriate ratings. 17.44 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## T7M (Stored energy) 1000A, 1200A, 600V ∆ Electronic Dimensions 3P Fixed Version 10.55H x 8.26W x 7D Weight 24.25 (Ibs) **==> picture [13 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> T7M<br>**----- End of picture text -----**<br> ## General The T7M breaker is a stored energy 1200A frame with a microprocessor based overcurrent protective trip system. ## Standards The UL489/CSA 22.2 version of T7M also carries an IEC-60947-2 rating. ## UL489 / CSA C22.2 Interrupting capacity (kA RMS) |Voltage|S|H|L| |---|---|---|---| |240VAC|65|100|150| |480VAC|50|65|100| |600VAC|25|50|65| ## Versions To meet all application requirements, the T7M is available in the following versions: - B = Selectable & adjustable LI or LS — Dip switch setting - C = Adjustable LSI — Dip switch setting - E = Adjustable LSIG — Dip switch setting - D = Molded Case Switch - P = LI — LCD display - R = LSI — LCD display S = LSIG — LCD display ## IEC 60947-2 Interrupting capacity (kA RMS) |Voltage|S|H|L| |---|---|---|---| |230VAC|85|100|200| |415VAC|50|70|120| |690VAC|30|42|50| ## Trip functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault ## Performance levels Each version is also available in different maximum fault interrupting levels: S = Standard - H = High - L = Extra high ## Number of poles The T7M is available as a three and four pole breaker. 17.45 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage T7M 1000A, 1200A, 600V ∆ Electronic 17 T 7 M **==> picture [304 x 352] intentionally omitted <==** **----- Start of picture text -----**<br> Locking provisions:<br>X = None<br>A = Keylock; B = Button guard<br>C = Padlock provision (open)<br>F = A+B<br>Accessories:<br>X = None<br>A = Mechanical counter<br>B = Trip signal<br>C = Trip signal and reset 24-30 VAC/DC<br>D = Trip signal and reset 110-130 VAC/DC<br>E = Trip signal and reset 200-240 VAC/DC<br>F = A+C; G=A+D; H=A+E<br>Undervoltage:<br>0 = None; A = 24 VAC/DC; B = 30 VAC/DC;<br>C = 48 VAC/DC; D = 60 VAC/DC; E = 110...120 VAC/DC<br>F = 120...127 VAC/DC; G = 220...240 VAC/DC;<br>H = 240…250 VAC/DC; J = 380…400 VAC; K = 415…440 VAC<br>Shunt trip:<br>0 = None; A = 24 VAC/DC; B = 30 VAC/DC;<br>C = 48 VAC/DC; D = 60 VAC/DC; E = 110…120 VAC/DC<br>F = 120…127 VAC/DC; G = 220…240 VAC/DC; H = 240…250 VAC/DC<br>J = 380…400 VAC; K = 415…440 VAC<br>Spring Charging Motor:<br>0 = None; A = 24…30 VAC/DC;<br>B = 48…60 VAC/DC; C = 100...130 VAC/DC; D = 220…250 VAC/DC<br>E = 380…415 VAC; F = Springs charged 24 VDC; G = Springs charged 250 VAC/DC;<br>H=A+F; J=B+F; K=C+F; L=D+F; M=E+F; N=A+G; P=B+G; Q=C+G; R=D+G; S=E+G<br>Auxilary Contacts:<br>0 = None A = 2 Form C (400 VAC); B = 2 Form C (24 VDC); C=Ready to close 24 VDC;<br>D = Ready to close 250 VAC/DC<br>Closing Coil:<br>0 = None; A = 24 VAC/DC; B = 30 VAC/DC; C = 48 VAC/DC;<br>D = 60 VAC/DC; E = 110…120 VAC/DC; F = 120…127 VAC/DC;<br>G = 220…240 VAC/DC; H = 240…250 VAC/DC; J = 380…400 VAC;<br>K = 415…440 VAC<br>**----- End of picture text -----**<br> - Trip Unit Accessories: 0 = None; A = PR330V; B = PR330/D-M; C = A + B (PR332/P only) - Trip Unit: A = PR231/P-I (MCP); B = PR231/P-LS/I; C = PR232/P-LSI; D = Non-Automatic (MCS); E = PR331/P-LSIG; P = PR332/P-LI; R = PR332/P-LSI; S = PR332P-/LSIG - Rating Plug: 0 = None; Non –Automatic (MCS) A = 400A; B = 600/630A; C = 800A; D = 1000A; E = 1200/1250A F = 1600A (IEC only) - Frame Ampere rating: - A3 = 800 A (3P) IEC only; P3 = 1000 A (3P); B3 = 1200/1250 A (3P); C3 1600 A (3P IEC only) A4 = 800 A (4P) IEC only; P4 = 1000 A (4P); B4 = 1200/1250 A (4P); C4 1600 A (4P IEC only) - Version: 0 = Fixed non-automatic (MCS); B = UL fixed; Q = UL fixed 100% rated; F = IEC fixed - Breaking Capacity: - S, H, L, V = IEC, T7 800, 1000, 1250A only); D = MCS (IEC) Call factory for IEC breaker pricing 17.46 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T7M 1000A, 1200A, 600V ∆ - Three Pole Electronic T7M-S, 1000A, 600V Electronic ## T7M-S, 1200A, 600V Electronic |Electronic||||Electronic|||| |---|---|---|---|---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|3 pole, 600V<br>Catalognumber|Breaker|IC at 480VAC kA|Trip unit|3 pole, 600V Catalog number| |T7M-S||PR231/P-LS/I|T7MSBP3DB000000XX|||PR231/P-LS/I|T7MSBB3EB000000XX| |||PR232/P-LSI|T7MSBP3DC000000XX|||PR232/P-LSI|T7MSBB3EC000000XX| |||PR331/P-LSIG|T7MSBP3DE000000XX|||PR331/P-LSIG|T7MSBB3EE000000XX| ||50|PR332/P-LI|T7MSBP3DP000000XX|T7M-S|50|PR332/P-LI|T7MSBB3EP000000XX| |||PR332/P-LSI|T7MSBP3DR000000XX|||PR332/P-LSI|T7MSBB3ER000000XX| |||PR332/P-LSIG|T7MSBP3DS000000XX<br>3 pole, 600V<br>Catalognumber|||PR332/P-LSIG|T7MSBB3ES000000XX| |T7M-H, 1000A, 600V<br>Electronic<br>Breaker<br>IC at 480VAC kA||Trip unit||T7M-H, 1200A, 600V<br>Electronic<br>Breaker<br>IC at 480VAC kA||Trip unit|3 pole, 600V Catalog number| |T7M-H||PR231/P-LS/I|T7MHBP3DB000000XX|||PR231/P-LS/I|T7MHBB3EB000000XX| |||PR232/P-LSI|T7MHBP3DC000000XX|||PR232/P-LSI|T7MHBB3EC000000XX| |||PR331/P-LSIG|T7MHBP3DE000000XX|||PR331/P-LSIG|T7MHBB3EE000000XX| ||65|PR332/P-LI|T7MHBP3DP000000XX|T7M-H|65|PR332/P-LI|T7MHBB3EP000000XX| |||PR332/P-LSI|T7MHBP3DR000000XX|||PR332/P-LSI|T7MHBB3ER000000XX| |||PR332/P-LSIG|T7MHBP3DS000000XX|||PR332/P-LSIG|T7MHBB3ES000000XX| T7M-L, 1000A, 600V Electronic T7M-L, 1200A, 600V Electronic |Electronic|||||Electronic|||| |---|---|---|---|---|---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|3 pole, 600V<br>Catalognumber||Breaker|IC at 480VAC kA|Trip unit|3 pole, 600V<br>Catalognumber| |T7M-L||PR231/P-LS/I|T7MLBP3DB000000XX||||PR231/P-LS/I|T7MLBB3EB000000XX| |||PR232/P-LSI|T7MLBP3DC000000XX||||PR232/P-LSI|T7MLBB3EC000000XX| |||PR331/P-LSIG|T7MLBP3DE000000XX||||PR331/P-LSIG|T7MLBB3EE000000XX| ||100|PR332/P-LI|T7MLBP3DP000000XX||T7M-L|100|PR332/P-LI|T7MLBB3EP000000XX| |||PR332/P-LSI|T7MLBP3DR000000XX||||PR332/P-LSI|T7MLBB3ER000000XX| |||PR332/P-LSIG|T7MLBP3DS000000XX||||PR332/P-LSIG|T7MLBB3ES000000XX| 17.47 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T7M 1000A, 1200A, 600V ∆ - Three Pole Electronic 100% Rated ## T7M-S, 1000A, 600V Electronic ## T7M-S, 1200A, 600V Electronic |Electronic|||| |---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|3 pole, 600V<br>Catalognumber| |T7M-S||PR231/P-LS/I|T7MSQP3DB000000XX| |||PR232/P-LSI|T7MSQP3DC000000XX| |||PR331/P-LSIG|T7MSQP3DE000000XX| ||50|PR332/P-LI|T7MSQP3DP000000XX| |||PR332/P-LSI|T7MSQP3DR000000XX| |||PR332/P-LSIG|T7MSQP3DS000000XX| |Electronic|||| |---|---|---|---| |Breaker|IC at 480VAC<br>kA|<br>Trip unit|3 pole, 600V<br>Catalognumber| |||PR231/P-LS/I|T7MSQB3EB000000XX| |||PR232/P-LSI|T7MSQB3EC000000XX| |||PR331/P-LSIG|T7MSQB3EE000000XX| |T7M-S|50|PR332/P-LI|T7MSQB3EP000000XX| |||PR332/P-LSI|T7MSQB3ER000000XX| |||PR332/P-LSIG|T7MSQB3ES000000XX| |T7M-H, 1200A, 600V<br>Electronic<br>Breaker<br>IC at 480VAC<br>kA||<br>Trip unit|3 pole, 600V<br>Catalognumber| |||PR231/P-LS/I|T7MHQB3EB000000XX| |||PR232/P-LSI|T7MHQB3EC000000XX| |||PR331/P-LSIG|T7MHQB3EE000000XX| |T7M-H|65|PR332/P-LI|T7MHQB3EP000000XX| |||PR332/P-LSI|T7MHQB3ER000000XX| |||PR332/P-LSIG|T7MHQB3ES000000XX| ## T7M-H, 1000A, 600V Electronic |Electronic|||| |---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|3 pole, 600V<br>Catalognumber| |T7M-H||PR231/P-LS/I|T7MHQP3DB000000XX| |||PR232/P-LSI|T7MHQP3DC000000XX| |||PR331/P-LSIG|T7MHQP3DE000000XX| ||65|PR332/P-LI|T7MHQP3DP000000XX| |||PR332/P-LSI|T7MHQP3DR000000XX| |||PR332/P-LSIG|T7MHQP3DS000000XX| ## T7M-L, 1000A, 600V Electronic ## T7M-L, 1200A, 600V Electronic |Electronic|||||Electronic|||| |---|---|---|---|---|---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|3 pole, 600V<br>Catalognumber||Breaker|IC at 480VAC<br>kA|<br>Trip unit|3 pole, 600V<br>Catalognumber| |T7M-L||PR231/P-LS/I|T7MLQP3DB000000XX||||PR231/P-LS/I|T7MLQB3EB000000XX| |||PR232/P-LSI|T7MLQP3DC000000XX||||PR232/P-LSI|T7MLQB3EC000000XX| |||PR331/P-LSIG|T7MLQP3DE000000XX||||PR331/P-LSIG|T7MLQB3EE000000XX| ||100|PR332/P-LI|T7MLQP3DP000000XX||T7M-L|100|PR332/P-LI|T7MLQB3EP000000XX| |||PR332/P-LSI|T7MLQP3DR000000XX||||PR332/P-LSI|T7MLQB3ER000000XX| |||PR332/P-LSIG|T7MLQP3DS000000XX||||PR332/P-LSIG|T7MLQB3ES000000XX| 17.48 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T7M 1000A, 1200A, 600V ∆ - Four Pole Electronic T7M-S, 1000A, 600V Electronic T7M-S, 1200A, 600V Electronic |Electronic||||Electronic|||| |---|---|---|---|---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|4 pole, 600V<br>Catalognumber|Breaker|IC at<br>480VAC kA|Trip unit|4 pole, 600V<br>Catalognumber| |T7M-S||PR231/P-LS/I|T7MSBP4DB000000XX|||PR231/P-LS/I|T7MSBB4EB000000XX| |||PR232/P-LSI|T7MSBP4DC000000XX|||PR232/P-LSI|T7MSBB4EC000000XX| |||PR331/P-LSIG|T7MSBP4DE000000XX|||PR331/P-LSIG|T7MSBB4EE000000XX| ||50|PR332/P-LI|T7MSBP4DP000000XX|T7M-S|50|PR332/P-LI|T7MSBB4EP000000XX| |||PR332/P-LSI|T7MSBP4DR000000XX|||PR332/P-LSI|T7MSBB4ER000000XX| |||PR332/P-LSIG|T7MSBP4DS000000XX|||PR332/P-LSIG|T7MSBB4ES000000XX| T7M-H, 1000A, 600V Electronic |Electronic|||| |---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|4 pole, 600V<br>Catalognumber| |T7M-H||PR231/P-LS/I|T7MHBP4DB000000XX| |||PR232/P-LSI|T7MHBP4DC000000XX| |||PR331/P-LSIG|T7MHBP4DE000000XX| ||65|PR332/P-LI|T7MHBP4DP000000XX| |||PR332/P-LSI|T7MHBP4DR000000XX| |||PR332/P-LSIG|T7MHBP4DS000000XX| |T7M-L, 1000A, 600V<br>Electronic|||| |Breaker|IC at 480VAC kA|Trip unit|4 pole, 600V Catalog number| |T7M-L|100|PR231/P-LS/I|T7MLBP4DB000000XX| |||PR232/P-LSI|T7MLBP4DC000000XX| |||PR331/P-LSIG|T7MLBP4DE000000XX| |||PR332/P-LI|T7MLBP4DP000000XX| |||PR332/P-LSI|T7MLBP4DR000000XX| |||PR332/P-LSIG|T7MLBP4DS000000XX| ## T7M-H, 1200A, 600V Electronic |Electronic|||| |---|---|---|---| |Breaker|IC at 480VAC<br>kA|<br>Trip unit|4 pole, 600V<br>Catalognumber| |T7M-H||PR231/P-LS/I|T7MHBB4EB000000XX| |||PR232/P-LSI|T7MHBB4EC000000XX| ||65|PR331/P-LSIG|T7MHBB4EE000000XX| |||PR332/P-LI|T7MHBB4EP000000XX| |||PR332/P-LSI|T7MHBB4ER000000XX| |||PR332/P-LSIG|T7MHBB4ES000000XX| T7M-L, 1200A, 600V Electronic |Electronic|||| |---|---|---|---| |Breaker|IC at 480VAC<br>kA|<br>Trip unit|4 pole, 600V<br>Catalognumber| |||PR231/P-LS/I|T7MLBB4EB000000XX| |||PR232/P-LSI|T7MLBB4EC000000XX| |TML||PR331/P-LSIG|T7MLBB4EE000000XX| |7-|100|PR332/P-LI|T7MLBB4EP000000XX| |||PR332/P-LSI|T7MLBB4ER000000XX| |||PR332/P-LSIG|T7MLBB4ES000000XX| 17.49 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T7M 1000A, 1200A, 600V ∆ - Four Pole Electronic 100% Rated ## T7M-S, 1000A, 600V Electronic ## T7M-S, 1200A, 600V Electronic |Electronic||||Electronic|||| |---|---|---|---|---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|4 pole, 600V<br>Catalognumber|Breaker|IC at 480VAC kA|Trip unit|4 pole, 600V<br>Catalognumber| |T7M-S||PR231/P-LS/I|T7MSQP4DB000000XX|||PR231/P-LS/I|T7MSQB4EB000000XX| |||PR232/P-LSI|T7MSQP4DC000000XX|||PR232/P-LSI|T7MSQB4EC000000XX| |||PR331/P-LSIG|T7MSQP4DE000000XX|||PR331/P-LSIG|T7MSQB4EE000000XX| ||50|PR332/P-LI|T7MSQP4DP000000XX|T7M-S|50|PR332/P-LI|T7MSQB4EP000000XX| |||PR332/P-LSI|T7MSQP4DR000000XX|||PR332/P-LSI|T7MSQB4ER000000XX| |||PR332/P-LSIG|T7MSQP4DS000000XX|||PR332/P-LSIG|T7MSQB4ES000000XX| ## T7M-H, 1000A, 600V Electronic ## T7M-H, 1200A, 600V Electronic |Electronic|||| |---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|4 pole, 600V<br>Catalognumber| |T7M-H||PR231/P-LS/I|T7MHQP4DB000000XX| |||PR232/P-LSI|T7MHQP4DC000000XX| |||PR331/P-LSIG|T7MHQP4DE000000XX| ||65|PR332/P-LI|T7MHQP4DP000000XX| |||PR332/P-LSI|T7MHQP4DR000000XX| |||PR332/P-LSIG|T7MHQP4DS000000XX| |Electronic|||| |---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|4 pole, 600V<br>Catalognumber| |||PR231/P-LS/I|T7MHQB4EB000000XX| |||PR232/P-LSI|T7MHQB4EC000000XX| |||PR331/P-LSIG|T7MHQB4EE000000XX| |T7M-H|65|PR332/P-LI|T7MHQB4EP000000XX| |||PR332/P-LSI|T7MHQB4ER000000XX| |||PR332/P-LSIG|T7MHQB4ES000000XX| ## T7M-L, 1000A, 600V Electronic T7M-L, 1200A, 600V Electronic |Electronic|||| |---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|4 pole, 600V<br>Catalognumber| |T7M-L||PR231/P-LS/I|T7MLQP4DB000000XX| |||PR232/P-LSI|T7MLQP4DC000000XX| ||100|PR331/P-LSIG|T7MLQP4DE000000XX| |||PR332/P-LI|T7MLQP4DP000000XX| |||PR332/P-LSI|T7MLQP4DR000000XX| |||PR332/P-LSIG|T7MLQP4DS000000XX| |Electronic|||| |---|---|---|---| |Breaker|IC at 480VAC kA|Trip unit|4 pole, 600V<br>Catalognumber| |T7M-L||PR231/P-LS/I|T7MLQB4EB000000XX| |||PR232/P-LSI|T7MLQB4EC000000XX| |||PR331/P-LSIG|T7MLQB4EE000000XX| ||100|PR332/P-LI|T7MLQB4EP000000XX| |||PR332/P-LSI|T7MLQB4ER000000XX| |||PR332/P-LSIG|T7MLQB4ES000000XX| 17.50 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A T7M 1200A, 600V ∆ - Molded Case Swich 17 |T7M<br>1200A, 600V<br>Molded case switch<br>Breaker<br>IC at<br>480VAC kA<br>Amp<br>Magnetic<br>override<br>3 pole, 600VAC Catalog<br>number|T7M<br>1200A, 600V<br>Molded case switch<br>Breaker<br>IC at<br>480VAC kA<br>Amp<br>Magnetic<br>override<br>3 pole, 600VAC Catalog<br>number|T7M<br>1200A, 600V<br>Molded case switch<br>Breaker<br>IC at<br>480VAC kA<br>Amp<br>Magnetic<br>override<br>3 pole, 600VAC Catalog<br>number|T7M<br>1200A, 600V<br>Molded case switch<br>Breaker<br>IC at<br>480VAC kA<br>Amp<br>Magnetic<br>override<br>3 pole, 600VAC Catalog<br>number|T7M<br>1200A, 600V<br>Molded case switch<br>Breaker<br>IC at<br>480VAC kA<br>Amp<br>Magnetic<br>override<br>3 pole, 600VAC Catalog<br>number| |---|---|---|---|---| |T7M-H|-|1200|20,000|T7MH0B30D000000XX| T7M 1000 - 1200A, 600V Motor circuit protection Electronic trip, instantaneous only **==> picture [257 x 80] intentionally omitted <==** **----- Start of picture text -----**<br> Breaker IC at 480VAC kA Amp Catalog number<br>T7M-S 50 1000 T7MSBP3DA000000XX<br>T7M-H 65 1000 T7MHBP3DA000000XX<br>T7M-L 100 1000 T7MLBP3DA000000XX<br>T7M-S 50 1200 T7MSBB3EA000000XX<br>T7M-H 65 1200 T7MHBB3EA000000XX<br>T7M-L 100 1200 T7MLBB3EA000000XX<br>**----- End of picture text -----**<br> 17.51 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 **==> picture [37 x 32] intentionally omitted <==** **----- Start of picture text -----**<br> Tmax<br>MCCBs<br>**----- End of picture text -----**<br> KT7MXC1 **==> picture [28 x 99] intentionally omitted <==** **----- Start of picture text -----**<br> KT7MXM*<br>KT7XU*<br>**----- End of picture text -----**<br> ## Accessories Electrical T7M |Accessories<br>Electrical<br>T7M|Accessories<br>Electrical<br>T7M|Accessories||| |---|---|---|---|---| |Closingcoils1||||Field installation<br>Catalognumber| |||415…440VAC||KT7MXC1| |||380…400VAC||KT7MXC2| |||240…250VAC/DC||KT7MXC3| |||220…240VAC/DC||KT7MXC4| |T7M||120…127 VAC/DC<br>110…120VAC/VDC||KT7MXC5<br>KT7MXC6| |||60VAC/DC||KT7MXC7| |||48VAC/DC||KT7MXC8| |||30VAC/DC||KT7MXC9| |||24 VAC/DC||KT7MXC0| |||||| |Auxiliary contacts||||Field installation<br>Catalognumber| |T7/T7M||2 FormC400VAC<br>2 FormC24 VDC||KT7XAS2<br>KT7XAS2-AU| |||||| |Ready to close auxiliaries (IEC)||||Field installation<br>Catalognumber| |T7M||24 VDC<br>250VAC/DC||KT7MX-RTC24V<br>KT7MX-RTC250V| |Signals the circuit breaker is ready to accept a close signal if the following five conditions are met:||||| |• Circuit breaker is open|• Circuit breaker is open|• Any opening coil de-energized<br>• Opening solenoid armed||| |• Closing springs are charged||• Closing springs are charged<br>• Any undervoltage coil energized||| |Trip signal||||Field/factory<br>installation<br>Catalognumber| |T7M||Contact forsignalling electronictrip unit tripped 1||KT7MTS| |||||| |Springchargingmotor1||||Field installation<br>Catalognumber| |||380…415VAC||KT7MXM2| |||220…250VAC/DC||KT7MXM3| |T7M||100…130VAC/DC||KT7MXM5| |||48…60VAC/DC||KT7MXM7| |||24…30VAC/DC||KT7MXM9| |||||| |Spring charged contacts (IEC)||||Field installation<br>Catalognumber| |T7M|Contactsignalling springs charged24 VDC<br>Contactsignalling springs charged250VAC/DC|||KT7MX-SC24V<br>KT7MX-SC250V| |||||| |Shunt trip||||Field installation<br>Catalognumber| |||415…440VAC||KT7XS1| |||380…400VAC||KT7XS2| |||240…250VAC/DC||KT7XS3| |||220…240VAC/DC||KT7XS4| |T7/T7M||120…127 VAC/DC<br>110…120VAC/DC||KT7XS5<br>KT7XS6| |||60VAC/DC||KT7XS7| |||48VAC/DC||KT7XS8| |||30VAC/DC||KT7XS9| |||24 VAC/DC||KT7XS0| |Undervoltage||||Field installation<br>Catalognumber| |||415…440VAC||KT7XU1| |||380…400VAC||KT7XU2| |||240…250VAC/DC||KT7XU3| |||220…240VAC/DC||KT7XU4| |T7/T7M||120…127 VAC/DC<br>110…120VAC/DC||KT7XU5<br>KT7XU6| |||60VAC/DC||KT7XU7| |||48VAC/DC||KT7XU8| |||30VAC/DC||KT7XU9| |||24 VAC/DC||KT7XU0| |||||| |Trip reset (IEC)||||Field installation<br>Catalognumber| ||Tripresetcommand24-30VAC/DC|||KT7MX-TR9| |T7M|Tripresetcommand110-130VAC/DC|||KT7MX-TR5| ||Tripresetcommand200-240VAC/DC|||KT7MX-TR4| |Allows remote circuit breaker resetting following a trip of the overcurrent release||||| 1 Not Suitable for T7 toggle version. 2 Always supplied with PR332/P trip units 17.52 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Accessories Mechanical T7M **==> picture [31 x 93] intentionally omitted <==** **----- Start of picture text -----**<br> KT7MXMC<br>KT7XPG<br>**----- End of picture text -----**<br> **==> picture [27 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KT7MKL*<br>**----- End of picture text -----**<br> |Terminal lugs<br>Frame Size<br>Wire Size<br>Catalog number<br>(3pieces)<br>Catalog number<br>(4pieces)<br>T7/T7M1<br>(4)4/0-500 kxmil<br>KT7X1200-3 1<br>KT7X1200-41<br>~~——____| _}_ —___}____~~|Terminal lugs<br>Frame Size<br>Wire Size<br>Catalog number<br>(3pieces)<br>Catalog number<br>(4pieces)<br>T7/T7M1<br>(4)4/0-500 kxmil<br>KT7X1200-3 1<br>KT7X1200-41<br>~~——____| _}_ —___}____~~|Terminal lugs<br>Frame Size<br>Wire Size<br>Catalog number<br>(3pieces)<br>Catalog number<br>(4pieces)<br>T7/T7M1<br>(4)4/0-500 kxmil<br>KT7X1200-3 1<br>KT7X1200-41<br>~~——____| _}_ —___}____~~| |---|---|---| |Terminal covers - Low profile - kit includes two pieces-fixed breakers<br>Frame Size<br>Catalog number<br>(3pole)<br>Catalog number<br>(4pole)<br>T7/T7M2<br>KT7XLTC-3<br>KT7XLTC-4<br>~~—____|__|___~~||| |Terminal covers - High profile - kit includes two pieces<br>Frame Size<br>Catalog number<br>(3pole)<br>Catalog number<br>(4pole)<br>T7/T7M<br>KT7XHTC-3<br>KT7XHTC-4<br>~~|__| __~~||| |Phase barriers - Low profile 100mm - 3.93 in<br>Frame Size<br>Catalog number<br>4pcs(3pole)<br>Catalog number<br>6pcs(4pole)<br>T7/T7M<br>KT7PBL-3 2<br>KT7PBL-4<br>~~——___|__|__~~||| |Phase barriers - High profile 200mm - 7.87 in<br>Frame<br>Catalog number<br>4pcs(3pole)<br>Catalog number<br>6pcs(4pole)<br>T7/T7M<br>KT7PBH-3<br>KT7PBH-4<br>~~—__}_ ___}_ ___~~||| |Mechanical operation counter3||| |Frame|Field/factory installation<br>Catalognumber|| |T7M<br>Mechanicalcounter3|KT7MXMC|| |Transparent protection for buttons3<br>Frame<br>Field/factory installation<br>Catalognumber<br>T7M<br>ButtonGuard 3<br>KT7MXPG<br>~~——_______}_ —_________} —___~~||| |Padlock provision3||| |Frame|Field/factory installation<br>Catalognumber|| |T7M<br>Padlock-open3|KT7MXLDO|| |Key locks||| |Frame Sizer<br>Key lock<br>openposition|Field/factory installation<br>Catalognumber|| |Key lock on breaker||| |open position|KT7MKL2|| |T7M<br>keylock # 20005 3<br>Key lock on breaker||| |open position|KT7MKL1|| |different keys 3||| |Mechanical interlock||| |Frame|Catalog<br>part number|| |Cable T7|KT7XMLC|| |T7M/T7M<br>Mechanical interlockplate - drawout|KT7XMLPW|| |Mechanical interlockplate - fixed|KT7XMLPF|| IP54 door protection 3 Field Installation Frame Catalog number T7M Protective cover 3 KT7MXDC ~~|__| ___~~ 1 Comes standard with high profile terminal covers. > 2 Fixed breakers only > 3 Not Suitable for T7 toggle version 17.53 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 = |Tmax<br>MCCBs|Accessories<br>Mechanical| |---|---| ||T7M| ||Draw-out kits| ||Frame<br>Adaptor moving part<br>Fixed Part<br>T7M 3 Pole with horizontal/vertical terminals<br>KT7XWMK<br>KT7WFHR<br>~~ff~~| |Sliding contact blocks<br>T7M - Drawout<br>Moving part<br>breaker<br>Fixed part<br>cradle<br>Left Block<br>Spring charging motor<br>Spring charged contact<br>Ready to close contact<br>Early auxiliary contact<br>Contact for trip coil trip release<br>Trip reset<br>KT7XSCMP-L<br>KT7XSCFP-L<br>Center Block<br>PR331<br>PR332<br>KT7XSCMP-C<br>KT7XSCFP-C<br>Right Block<br>Auxiliary contacts<br>Shunt trip<br>Closing coil<br>Undervoltage release<br>KT7XSCMP-R<br>KT7XSCFP-R<br>Sliding Contacts<br>4 gig~~ee~~|| ||If at least one of the accessories in the table is installed on the breaker - respective pair of contact blocks must be installed on the| ||fixed part (cradle) and the moving part (breaker)| **==> picture [32 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> PR330/D-M<br>**----- End of picture text -----**<br> |Position key lock<br>Locks drawout breaker in<br>racked-in/test-isoloated/racked-out<br>Catalog number<br>Key #20005<br>Different keys<br>KT7XPL2<br>KT7XPL1<br>~~—__—~~|Position key lock<br>Locks drawout breaker in<br>racked-in/test-isoloated/racked-out<br>Catalog number<br>Key #20005<br>Different keys<br>KT7XPL2<br>KT7XPL1<br>~~—__—~~|Position key lock<br>Locks drawout breaker in<br>racked-in/test-isoloated/racked-out<br>Catalog number<br>Key #20005<br>Different keys<br>KT7XPL2<br>KT7XPL1<br>~~—__—~~| |---|---|---| |Position lock accessory<br>Added to position lock allows breaker<br>to be locked in racked outpostion only<br>Catalog number<br>Position lock accessory<br>KT7XPLA<br>~~ee~~||| |Rating plugs(UL)||Catalog number| |400A Rating plug||KT7X0400RP| |600A Rating plug||KT7X0600RP| |T7/T7M<br>800A Rating plug<br>1000A Rating plug<br>1200A Rating plug<br>Modules for T7M PR332 trip units<br>T7/T7M<br>Voltage module1<br>Communication module(Modbus RTU)<br>External units<br>Battery powersupply unit2<br>~~—~~||KT7X0800RP<br>KT7X1000RP<br>KT7X1200RP<br>Catalog number<br>PR330/VT7MX1<br>PR330/D-M<br>Catalog number<br>PR030/B| |External Bluetooth communication module||| |Includes diagnostic software for||BT030| |T7/T7M<br>Modbus/Bluetooth networks<br>Testconfigurationunit||PR010/T| |Allows tripping of all electronic trip units for Tmax<br>(except PR33x)||K7TUT| |Currentsensor forexternal neutral||KT7NCT| ## Accessory connector |Accessory connector|Catalog number| |---|---| |Accessory connector<br>For wiringto internal accessories|KT7XAC| 17.54 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Technical data T7/T7M Shunt tips, closing coil, Undervoltage & spring charging motor ## Standard shunt trip **==> picture [258 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> Inrush Power Consumption T7/T7M<br>Voltage AC (VA) DC (W)<br>24 VAC/DC 300 300<br>30 VAC/DC 300 300<br>48 VAC/DC 300 300<br>60 VAC/DC 300 300<br>110…120 VAC/DC 300 300<br>120…127 VAC/DC 300 300<br>220…240 VAC/DC 300 300<br>240…240 VAC/DC 300 300<br>380…400 VAC 300 —<br>415…440 VAC 300 —<br>Opening time (ms) 20 20<br>**----- End of picture text -----**<br> ## Undervoltage **==> picture [257 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> Inrush Power Consumption T7/T7M<br>Voltage AC (VA) DC (W)<br>24 VAC/DC 3.5 3.5<br>30 VAC/DC 3.5 3.5<br>110…120 VAC/DC 3.5 3.5<br>120…127 VAC/DC 3.5 3.5<br>220…240 VAC 3.5 3.5<br>240…250 VAC/DC 3.5 3.5<br>380…400 VAC 3.5 —<br>415…440 VAC 3.5 —<br>Opening time (ms) ≤ 25 ≤ 25<br>**----- End of picture text -----**<br> ## Closing coil **==> picture [258 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> Inrush Power Consumption T7M<br>Voltage AC (VA) DC (W)<br>24 VAC/DC 300 300<br>30 VAC/DC 300 300<br>48 VAC/DC 300 300<br>60 VAC/DC 300 300<br>110…120 VAC/DC 300 300<br>120…127 VAC/DC 300 300<br>220…240 VAC/DC 300 300<br>240…240 VAC/DC 300 300<br>380…400 VAC 300 —<br>415…440 VAC 300 —<br>Opening time (ms) 20 20<br>**----- End of picture text -----**<br> ## Spring charging motor **==> picture [257 x 89] intentionally omitted <==** **----- Start of picture text -----**<br> Power Consumption T7M<br>Voltage AC (VA) DC (W)<br>24….30 VAC/DC ≤ 100 ≤ 100<br>48…60 VAC/DC ≤ 100 ≤ 100<br>100…130 VAC/DC ≤ 100 ≤ 100<br>220…250 VAC/DC ≤ 100 ≤ 100<br>380…415 VAC ≤ 100 —<br>Opening voltage (% Un) 85-110 85-110<br>Charging time (s) 8-10 8-10<br>**----- End of picture text -----**<br> 17.55 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## ## T8 1600/2000/2500/3000A, 600VAC ∆ Electronic trip Dimensions 3P Fixed Version 15.0H x 16.8W x 11.2D Weight 161 lbs (1600, 2000, 2500A) 236 lbs (3000A) **==> picture [8 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> T8<br>**----- End of picture text -----**<br> ## General The T8 is available in a 1600A, 2000A, 2500A, 3000A frame with a microprocessor over current protective trip system. ## Standards The UL489/CSA 22.2 version of the T8 also carries an IEC-60947-2 rating. ## Versions To meet all application requirements the T8 is available in the following versions: - C = Adjustable LSI PR232/P-T8 Dip switch settings - D = Molded Case Switch - E = Adjustable LSIG PR331/P Dip switch settings - P = Adjustable LI PR332/P LCD Display - R = Adjustable LSI PR332/P LCD Display - S = Adjustable LSIG PR332/P LCD Display - Rc = Residual Current (IEC, 3 pole, under 3200A only) ## Trip functions These trip functions are available: - L = Long time - S = Short time - I = Instantaneous - G = Ground fault UL489/CSA C22.2 Interrupting capacity (kA RMS) Voltage V 240VAC 125 480VAC 125 600VAC 100 ~~Ee~~ DC — IEC 60947-2 Interrupting capacity (kA RMS) Voltage V 230VAC 130 415VAC 130 440VAC 100 690VAC 80 ~~=F~~ DC — ## Performance levels Each version is also available at the following maximum fault interrupting level: V = Very high ## Number of poles The T8 is available in three and four pole versions. 17.56 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage T8 Catalog number explanation 17 T 8 V - Locking provisions: X = None; A = Keylock B = Button guard; C = Padlock provision; D = A+B; E = A+C T = Heavy duty padlock; 9 = Extra heavy duty padlock - Accessories X = None; A = Mechanical counter; B = Bell Alarm C = Bell Alarm w/remote reset, 24..30 VAC/DC D = Bell Alarm w/remote reset 110..130 VAC/DC E = Bell Alarm w/remote reset 220..240 VAC/DC F = A+B; G = A+C; H = A+D; J = A+E - Undervoltage 0 = None A = 24 VDC; B = 30 VAC/DC C = 48 VAC/DC; D = 60 VAC/DC E = 110..120 VAC/DC; F = 125..127 VAC/DC G = 220..240 VAC/DC; H = 250 VAC/DC J = 380..400 VAC; K = 440 VAC Second shunt trip: L = 24 VDC; M = 30 VAC/DC N = 48 VAC/DC; P = 60 VAC/DC Q = 110..120 VAC/DC; R = 125..127 VAC/DC S = 220..240 VAC/DC; T = 250 VAC/DC U = 380..400 VAC; V = 440..480 VAC - Shunt trip 0 = None A = 24 VDC; B = 30 VAC/DC; C = 48 VAC/DC; D = 60 VAC/DC; E = 110..120 VAC/DC F = 120..127 VAC/DC; G = 220..240 VAC/DC; H = 240..250 VAC/DC; J = 380…400 VAC; K = 440 VAC - Spring charging motor: 0 = None A = 24..30 VAC/DC; B = 48..60 VAC/DC; C = 100..130 VAC/DC; D = 220..250 VAC/DC - Contacts: 0 = None - A = 4 aux contacts; (supplied as standard for breakers with PR332 trip units) B = 4 aux contacts digital (24V) - D = UV energ NO; E = UV energ NC; F = A+D; G = A+E; H = B+D; J = B+E - Closing Coil: 0 = None - A = 24 VDC; B = 30 VAC/DC; C = 48 VAC/DC; D = 60 VAC/DC; E = 110..120 VAC/DC; - F = 120..127 VAC/DC; G = 220..240 AC/DC; H = 240..250 VAC/DC; J = 380..400 VAC; K = 440VAC ## Trip Unit Accessories: PR332/P ONLY - 0 = None - B = Voltage measuring module; C = Modbus module ## Trip Unit: - C = PR331/P-T8-LSI; D = Non-Automatic (MCS); E = PR331/P-LSIG; - P = PR332/P-LI; R = PR332/P-LSI; S = PR332/P-LSIG; H = PR332/P-LSIRc (IEC) ## Rating Plug: - D = 1000; E = 1200; F = 1600; G = 2000; H = 2500; J = 3000, 3200; 0 = Non-Automatic (MCS) ## Frame Amp Rating: C3 = 1600 (3P UL only); D3 = 2000 (3P); E3 = 2500 (3P); F3 = 3000 UL/3200 IEC (3P) - C4 = 1600 (4P UL only); D4 = 2000 (4P); E4 = 2500 (4P); F4 = 3000 UL/3200 IEC (4P) ## Version: - B = UL Fixed; Q = UL Fixed 100% Rated; F = IEC Fixed; 0 = Fixed Non-Automatic (MCS) ## Breaking capacity: - V = Very High; L (IEC only. Call factory for IEC breaker pricing.) 17.57 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T8 1600/2000/2500/3000A 600V∆ - Three Pole Electronic (AC Only) 1600A Frame, electronic trip unit (AC only) standard horizontal terminals |horizontal|terminals||| |---|---|---|---| |Breaker<br>|IC at 480VAC<br>kA|<br>Trip Unit|3 pole, 600V<br>Catalognumber| |T8V||PR232 LSI(DipSwitch)|T8VBC3FC000000XX| |||PR331 LSIG(DipSwitch)|T8VBC3FE000000XX| ||125|PR332 LI(LCD)|T8VBC3FP00A000XX1| |||PR332 LSI(LCD)|T8VBC3FR00A000XX1| |||PR332 LSIG(LCD)|T8VBC3FS00A000XX1| 2500A Frame, electronic trip unit (AC only) standard horizontal terminals |horizontal|terminals||| |---|---|---|---| |Breaker|IC at<br>480VAC kA|Trip Unit|3 pole, 600V<br>Catalognumber| |T8V||PR232 LSI(DipSwitch)|T8VBE3HC000000XX| |||PR331 LSIG(DipSwitch)|T8VBE3HE000000XX| ||125|PR332 LI(LCD)|T8VBE3HP00A000XX1| |||PR332 LSI(LCD)|T8VBE3HR00A000XX1| |||PR332 LSIG(LCD)|T8VBE3HS00A000XX1| 2000A Frame, electronic trip unit (AC only) standard horizontal terminals |horizontal|terminals||| |---|---|---|---| |Breaker|IC at<br>480VAC kA|Trip Unit|3 pole, 600V<br>Catalognumber| |T8V||PR232 LSI(DipSwitch)|T8VBD3GC000000XX| ||125|PR331 LSIG(DipSwitch)|T8VBD3GE000000XX| |||PR332 LI(LCD)|T8VBD3GP00A000XX1| |||PR332 LSI(LCD)|T8VBD3GR00A000XX1| |||PR332 LSIG(LCD)|T8VBD3GS00A000XX1| 3000A Frame, electronic trip unit (AC only) standard with vertical terminals - Required |Breaker|IC at 480VAC<br>kA|<br>Trip Unit|3 pole, 600V<br>Catalognumber| |---|---|---|---| |T8V||PR232 LSI(DipSwitch)|T8VBF3JC000000XX| |||PR331 LSIG(DipSwitch)|T8VBF3JE000000XX| ||125|PR332 LI(LCD)|T8VBF3JP00A000XX1| |||PR332 LSI(LCD)|T8VBF3JR00A000XX1| |||PR332 LSIG(LCD)|T8VBF3JS00A000XX1| 1 Includes 4 open/closed auxillary contacts as standard 17.58 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## T8 1600/2000/2500/3000A 600V∆ - Three Pole Electronic (AC Only) 100% Rated 1600A Frame, electronic trip unit (AC only) standard horizontal terminals |Breaker|IC at<br>480VAC kA|Trip Unit|3 pole, 600V<br>Catalognumber| |---|---|---|---| |T8V|125|PR232 LSI(DipSwitch)|T8VQC3FC000000XX| |||PR331 LSIG(DipSwitch)|T8VQC3FE000000XX| |||PR332 LI(LCD)|T8VQC3FP00A000XX1| |||PR332 LSI(LCD)|T8VQC3FR00A000XX1| |||PR332 LSIG(LCD)|T8VQC3FS00A000XX1| 2500A Frame, electronic trip unit (AC only) standard with vertical terminals - Required |<br>Breaker|<br>IC at<br>480VAC kA|<br>Trip Unit|3 pole, 600V<br>Catalognumber| |---|---|---|---| |||PR232 LSI(DipSwitch)|T8VQE3HC000000XX| |||PR331 LSIG(DipSwitch)|T8VQE3HE000000XX| |T8V|125|PR332 LI(LCD)|T8VQE3HP00A000XX1| |||PR332 LSI(LCD)|T8VQE3HR00A000XX1| |||PR332 LSIG(LCD)|T8VQE3HS00A000XX1| 2000A Frame, electronic trip unit (AC only) standard horizontal terminals |Breaker|IC at<br>480VAC kA|Trip Unit|3 pole, 600V<br>Catalognumber| |---|---|---|---| |T8V|125|PR232 LSI(DipSwitch)|T8VQD3GC000000XX| |||PR331 LSIG(DipSwitch)|T8VQD3GE000000XX| |||PR332 LI(LCD)|T8VQD3GP00A000XX1| |||PR332 LSI(LCD)|T8VQD3GP00A000XX1| |||PR332 LSIG(LCD)|T8VQD3GR00A000XX1| 3000A Frame, electronic trip unit (AC only) standard with vertical terminals - Required |<br>Breaker|<br>IC at<br>480VAC kA|<br>Trip Unit|3 pole, 600V<br>Catalognumber| |---|---|---|---| |||PR232 LSI(DipSwitch)|T8VQF3JC000000XX| |||PR331 LSIG(DipSwitch)|T8VQF3JE000000XX| |T8V|125|PR332 LI(LCD)|T8VQF3JP00A000XX1| |||PR332 LSI(LCD)|T8VQF3JR00A000XX1| |||PR332 LSIG(LCD)|T8VQF3JS00A000XX1| 1 Includes 4 open/closed auxillary contacts as standard 17.59 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T8 1600/2000/2500/3000A 600V∆— Four pole Electronic (AC Only) 1600A Frame, electronic trip unit (AC only) standard horizontal terminals |Breaker|IC at<br>480VAC kA|Trip Unit|4 pole, 600V<br>Catalognumber| |---|---|---|---| |T8V||PR232 LSI(DipSwitch)|T8VBC4FC000000XX| |||PR331 LSIG(DipSwitch)|T8VBC4FE000000XX| ||125|PR332 LI(LCD)|T8VBC4FP00A000XX1| |||PR332 LSI(LCD)|T8VBC4FR00A000XX1| |||PR332 LSIG(LCD)|T8VBC4FS00A000XX1| 2500A Frame, electronic trip unit (AC only) standard horizontal terminals |horizontal|terminals||| |---|---|---|---| |Breaker|IC at<br>480VAC kA|Trip Unit|4 pole, 600V<br>Catalognumber| |||PR232 LSI(DipSwitch)|T8VBE4HC000000XX| |||PR331 LSIG(DipSwitch)|T8VBE4HE000000XX| |T8V|125|PR332 LI(LCD)|T8VBE4HP00A000XX1| |||PR332 LSI(LCD)|T8VBE4HR00A000XX1| |||PR332 LSIG(LCD)|T8VBE4HS00A000XX1| ## 2000A Frame, electronic trip unit (AC only) standard horizontal terminals |Breaker|IC at<br>480VAC kA|Trip Unit|4 pole, 600V<br>Catalognumber| |---|---|---|---| |T8V||PR232 LSI(DipSwitch)|T8VBD4GC000000XX| |||PR331 LSIG(DipSwitch)|T8VBD4GE000000XX| ||125|PR332 LI(LCD)|T8VBD4GP00A000XX1| |||PR332 LSI(LCD)|T8VBD4GR00A000XX1| |||PR332 LSIG(LCD)|T8VBD4GS00A000XX1| 3000A Frame, electronic trip unit (AC only) standard with vertical terminals - Required |<br>Breaker|<br>IC at<br>480VAC kA|<br>Trip Unit|4 pole, 600V<br>Catalognumber| |---|---|---|---| |||PR232 LSI(DipSwitch)|T8VBF4JC000000XX| |||PR331 LSIG(DipSwitch)|T8VBF4JE000000XX| |T8V|125|PR332 LI(LCD)|T8VBF4JP00A000XX1| |||PR332 LSI(LCD)|T8VBF4JR00A000XX1| |||PR332 LSIG(LCD)|T8VBF4JS00A000XX1| 1 Includes 4 open/closed auxillary contacts as standard 17.60 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## T8 1600/2000/2500/3000A 600V∆—Four pole Electronic (AC Only) 100% Rated 1600A Frame, electronic trip unit (AC only) standard horizontal terminals |Breaker|IC at<br>480VAC kA|Trip Unit|4 pole, 600V<br>Catalognumber| |---|---|---|---| |T8V||PR232 LSI(DipSwitch)|T8VQC4FC000000XX| |||PR331 LSIG(DipSwitch)|T8VQC4FE000000XX| ||125|PR332 LI(LCD)|T8VQC4FP00A000XX1| |||PR332 LSI(LCD)|T8VQC4FR00A000XX1| |||PR332 LSIG(LCD)|T8VQC4FS00A000XX1| 2500A Frame, electronic trip unit (AC only) standard vertical terminals - Required |<br>Breaker|<br>IC at<br>480VAC kA|<br>Trip Unit|4 pole, 600V<br>Catalognumber| |---|---|---|---| |||PR232 LSI(DipSwitch)|T8VQE4HC000000XX| |||PR331 LSIG(DipSwitch)|T8VQE4HE000000XX| |T8V|125|PR332 LI(LCD)|T8VQE4HP00A000XX1| |||PR332 LSI(LCD)|T8VQE4HR00A000XX1| |||PR332 LSIG(LCD)|T8VQE4HS00A000XX1| 2000A Frame, electronic trip unit (AC only) standard horizontal terminals |Breaker|IC at<br>480VAC kA|Trip Unit|4 pole, 600V<br>Catalognumber| |---|---|---|---| |T8V||PR232 LSI(DipSwitch)|T8VQD4GC000000XX| |||PR331 LSIG(DipSwitch)|T8VQD4GE000000XX| ||125|PR332 LI(LCD)|T8VQD4GP00A000XX1| |||PR332 LSI(LCD)|T8VQC4GR00A000XX1| |||PR332 LSIG(LCD)|T8VQD4GS00A000XX1| 3000A Frame, electronic trip unit (AC only) standard with vertical terminals - Required |<br>Breaker|<br>IC at<br>480VAC kA|<br>Trip Unit|4 pole, 600V<br>Catalognumber| |---|---|---|---| |||PR232 LSI(DipSwitch)|T8VQF4JC000000XX| |||PR331 LSIG(DipSwitch)|T8VQF4JE000000XX| |T8V|125|PR332 LI(LCD)|T8VQF4JP00A000XX1| |||PR332 LSI(LCD)|T8VQF4JR00A000XX1| |||PR332 LSIG(LCD)|T8VQF4JS00A000XX1| 1 Includes 4 open/closed auxillary contacts as standard 17.61 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A ## ## T8 2000/2500/3000A 600V∆ Molded Case Switch T8V-D |T8V-D|| |---|---| |Rated Voltage|| |AC|600VAC| |DC|—| |Magnetic Overide|40000| ## 2000A Frame, standard horizontal terminals |Breaker|3 pole, 600V<br>Catalognumber| |---|---| |T8V-D|T8V0D30D000000XX| |2500A Frame, standard horizontal terminals<br>Breaker<br>3 pole, 600V<br>Catalognumber|| ||<br>3 pole, 600V<br>Catalognumber| |T8V-D|T8V0E30D000000XX| |3000A Frame, standard with vertical terminals - Required<br>Breaker<br>3 pole, 600V<br>Catalognumber|| ||<br>3 pole, 600V<br>Catalognumber| |T8V-D|T8V0F30D000000XX| 17 17.62 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage T8 Accessories, electrical 17 **==> picture [19 x 119] intentionally omitted <==** **----- Start of picture text -----**<br> KE6C*<br>KT8A4<br>**----- End of picture text -----**<br> |UL Rating plugs|UL Rating plugs|UL Rating plugs||1000A Rating plug|Catalog number<br>KT81000RP| |---|---|---|---|---|---| |||||1200A Rating plug|KT81200RP| |T8||||1600A Rating plug<br>2000A Rating plug|KT81600RP<br>KT82000RP| |||||2500A Rating plug|KT82500RP| |||||3000A Rating plug|KT83000RP| ||||||| |Accessories for trip units||Accessories for trip units|||Field/factory installation<br>Catalognumber| |||||Communication module(Modbus(RTU)|PR330/D-M2| |||||External wireless communication module|BT030| |T8||||Power supplyunit|PR030/B| |||||Voltage module,3pole3|PR330/V-T83| |||||Voltage module,4pole3|PR330/V-T84| ||||||| |Current sensor for external neutral|||Current sensor for external neutral||Field installation<br>Catalognumber| |T8|||Currentsensor forexternal neutral 1000A-3000A||KT8NCT| ||||||| |Closing coil|||||Field/factory installation<br>Catalognumber| |||||440 VAC|KE6C1| |||||380…400VAC|KE6C2| |||||240…250 VAC/DC|KE6C3| |||||220…240 VAC/DC|KE6C4| |T8||||120…127 VAC/DC<br>110…120 VAC/DC|KE6C5<br>KE6C6| |||||60 VAC/DC|KE6C7| |||||48 VAC/DC|KE6C8| |||||30 VAC/DC|KE6C9| |||||24 VDC|KE6C0| ||||||| |Auxiliary contacts|||||Field/factory installation<br>Catalognumber| |||||4 open/closed PR232-T8/PR331|KT8A4| |T8||||4 open/closed PR3321<br>4 open/closed 24V PR232-T8/PR331|KT8A4-PR332<br>KT8A4D| |||||4 open/closed 24V PR332|KT8A4D-PR332| ||||||| |Bell alarm|||||Field/factory installation<br>Catalognumber| |T8||Allows visual signaling (mechanical) and remote signaling (electrical)|Allows visual signaling (mechanical) and remote signaling (electrical)<br>ofcircuitbreakeropening by overcurrent release||DE6TBA| ||||||| |Bell alarm with remote reset command||||Bell alarm with remote reset command|Field/factory installation<br>Catalognumber| |||Remote setting of circuit breaker after opening by overcurrent release<br>220-240 VAC/DC|||DE6TBAR4| |T8||Remote setting of circuit breaker after opening by overcurrent release<br>110-130 VAC/DC|||DE6TBAR5| |||Remote setting of circuit breaker after opening by overcurrent release<br>24-30 VAC/DC|||DE6TBAR9| ||||||| |Contact signaling undervoltage de-energized|||||Field/factory installation<br>Catalognumber| |T8||||NC UV signalingcontact<br>NO UV signalingcontact|KE6UE01<br>KE6UE10| ||||||| |Spring charging motor|||||Field/factory installation<br>Catalognumber| |||||24…30VAC/DC|KE6M9| |T8||||48…60VAC/DC<br>100…130VAC/DC|KE6M7<br>KE6M5| |||||220…250VAC/DC|KE6M3| **==> picture [19 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KE6M*<br>**----- End of picture text -----**<br> 1 Included as standard on breakers ordered with PR332 trip unit 2 Discount schedule SAT (T0) 3 Factory install only. 17.63 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A T8 Accessories, electrical 17 **==> picture [17 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KE6S*<br>**----- End of picture text -----**<br> |Shunt trip||Field/factory installation<br>Catalognumber| |---|---|---| ||440 VAC|KE6S1| ||380…400 VAC|KE6S2| ||240…250 VAC/DC|KE6S3| ||220…240 VAC/DC|KE6S4| |T8|120…127 VAC/DC<br>110…120 VAC/DC|KE6S5<br>KE6S6| ||60 VAC/DC|KE6S7| ||48 VAC/DC|KE6S8| ||30 VAC/DC|KE6S9| ||24 VDC|KE6S0| |Second shunt trip 1|Second shunt trip 1|Field/factory installation<br>Catalognumber| |---|---|---| |T8|440 VAC|KE6S1-2| ||380…400 VAC|KE6S2-2| ||240…250 VAC/DC|KE6S3-2| ||220…240 VAC/DC|KE6S4-2| ||120…127 VAC/DC|KE6S5-2| ||110…120 VAC/DC|KE6S6-2| ||60 VAC/DC|KE6S7-2| ||48 VAC/DC|KE6S8-2| ||30 VAC/DC|KE6S9-2| ||24 VDC|KE6S0-2| **==> picture [18 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KE6U*<br>**----- End of picture text -----**<br> |Undervoltage|Undervoltage|Field/factory installation<br>Catalognumber| |---|---|---| |T8|440 VAC|KE6U1| ||380…400 VAC|KE6U2| ||240…250 VAC|KE6U3| ||220…240 VAC/DC|KE6U4| ||120…127 VAC/DC|KE6U5| ||110…120 VACV/DC|KE6U6| ||60 VAC/DC|KE6U7| ||48 VAC/DC|KE6U8| ||30 VAC/DC|KE6U9| ||24 VDC|KE6U0| 1 May be used in place undervoltage. 17.64 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage T8 Accessories, mechanical 17 |Key lock in open position|Key lock in open position|Field/factory installation<br>Catalognumber| |---|---|---| ||Keylock n. 200051|KT8KL2| ||Keylock n. 20006|KT8KL3| |T8|Keylock n. 20007|KT8KL4| ||Keylock n. 20008|KT8KL5| ||Keylock different keys|KT8KL1| |||| |Padlocking button cover||Field/factory installation<br>Catalognumber| ||3-4mm locks(padlocks not supplied)|KE6PD1| |T8|HDpadlock device|KE6PDHD1| ||Extra HDpadlock device|KE6PDHD2| |||| |Button guard||Field/factory installation<br>Catalognumber| |T8|Protective cover for opening and<br>closing pushbuttons|KE6PG| **==> picture [20 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> KE6PG<br>**----- End of picture text -----**<br> |Mechanical operation counter<br>Field/factory installation<br>Catalognumber<br>T8<br>Indicates the number of mechanical operations<br>KE6MC<br>~~ee~~|Mechanical operation counter<br>Field/factory installation<br>Catalognumber<br>T8<br>Indicates the number of mechanical operations<br>KE6MC<br>~~ee~~|Mechanical operation counter<br>Field/factory installation<br>Catalognumber<br>T8<br>Indicates the number of mechanical operations<br>KE6MC<br>~~ee~~|Mechanical operation counter<br>Field/factory installation<br>Catalognumber<br>T8<br>Indicates the number of mechanical operations<br>KE6MC<br>~~ee~~| |---|---|---|---| |Phase barriers-top terminals only|||Field installation<br>Catalognumber| ||Low 100mm 2pcs(3P)||KT8PBL-3| |T8|Low 100mm 3pcs(4P)<br>High 200mm 2pcs(3P)||KT8PBL-4<br>KT8PBH-3| ||High 200mm 4pcs(4P)||KT8PBH-4| ||||| |IP54 door protection|||Field installation<br>Catalognumber| |T8|Protective cover||KE6DC| ||||| |Vertical terminals|||Field installation<br>Catalognumber| |T8|Rear Vertical Terminals (2)|Set of six<br>Set of eight|KT82500VR-6<br>KT82500VR-8| ||||| |Cable terminals||Wire size|Field installation<br>Catalognumber| |T8|Mechanical Lugs (set of 3)|1/0-750 kcmil(4)<br>1/0-750 kcmil(6)|K8TL<br>K8TM| 1 Key lock number when factory installed is 20005. 17.65 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage T8 Technical data 17 ## Absorbed power on inrush |Absorbed power on inrush||| |---|---|---| |Shunt trip, Second shunt trip, closing coil<br>Voltage|AC|DC| |24 VDC|—|200| |30 VAC/DC|200|200| |48 VAC/DC|200|200| |60 VAC/DC|200|200| |110…120 VAC/DC|200|200| |120…127 VAC/DC|200|200| |220…240 VAC/DC|200|200| |380…400 VAC|200|—| |440 VAC|200|—| |Openingtime shunt trip- Second shunt trip (ms)|≤ 60|≤ 60| |Closingtime closingcoil(ms)|≤ 80|≤ 80| ## Spring charging motor |Spring charging motor||| |---|---|---| |Shunt trip, Second shunt trip, closing coil<br>Rated Voltage|AC|DC| ||24…30|24…30| ||48…60|48…60| ||100…130|100…130| ||220…250|220…250| |Operatingvoltage(%Un)|85-110|85…110| |Power consumption on inrush|500 VA|500 W| |Inrush time(s)|0.2|0.2| |Chargingtime(s)|4-5|4-5| 17.66 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Tmax UL489B Photovoltaic circuit breakers 17 ## Introduction Thanks to its experience with Tmax UL, ABB is proposing a complete range of products in accordance to UL489B, a new standard, whose requirements cover molded case circuit breakers and molded case switches rated up to 1000V DC, intended for use with photovoltaic systems. A complete range of MCCB and MCS is available up to 1000A for use at 1000V DC, complete with jumpers for connection of poles in series. Standards UL489B ## Dimensions ## Weights T1 - 3.2 lbs. T4 - 6.18 lbs. T5 - 8.55 lbs. T6 - 20.9 lbs. T7 - 24.25 lbs. Accessories Standard Tmax accessories are able to work with all UL 489B units. Jumpers come standard with all breakers in either all poles in series or 2+1 or 2+2. Breakers without lug kits come with terminals to connect to Busbar poles in series for installation options. All PV breakers are the same size as their standard UL/IEC counterparts. 17.67 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## General information Catalog number explanation ## Catalog number explanation ___ ___ ___ ___ ___ ___ ___ ___ T P Frame size Photovoltaic designation Jumpers A = Jumpers with all poles in series B = Jumpers with 2+2 or 2+1 configuration Amperage Number of poles Blank = 3 pole Connection L = With lugs W = Bus connection Device D = Molded case switch T = Thermal-mag circuit breaker 17.68 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Tmax UL489B Molded case circuit breakers and switches ## T4 - 200A Frame TMA, Thermal magnetic adjustable ## T1-D 100A Molded case switch |IC at 1000VDC|Rating|Lugs|Poles in Series|Catalog<br>number<br>T4PB040TL<br>T4PA040TL<br>T4PB050TL<br>T4PA050TL<br>T4PB080TL<br>T4PA080TL<br>T4PB100TL<br>T4PA100TL<br>T4PB125TL<br>T4PA125TL<br>T4PB150TL<br>T4PA150TL<br>T4PB200TL<br>T4PA200TL|Rating|Lugs|Poles in Series|Catalog<br>number| |---|---|---|---|---|---|---|---|---| |3kA|40A|Yes|2+1||100A||2+2|T1PB100DL-4| ||||3|||Yes|4|T1PA100DL-4| |3kA|||2+1||T4-D 200A Molded case switch<br>Rating<br>Lugs|||| ||50A|Yes|3|||||| |3kA|||2+1|||||| ||80A|Yes|3|||||| |||||||Lugs|Poles in Series|Catalog<br>number| |3kA|100A|Yes|2+1|||||| ||||3||200A||2+1|T4PB200DL| |3kA|125A|Yes|2+1|||Yes|3|T4PA200DL| ||||3||T5-D 400A Molded case switch|||| |3kA|||2+1|||||| ||150A|Yes|3|||||| |3kA|200A|Y|2+1||Rating|Lugs|Poles in Series|Catalog<br>number| |||es|3|||||| |||||||||TPBDL| ||||||400A|Y|2+1|5400| |||||||es|3|T5PA400DL| ||||||400A||2+1|T5PB400DW| |||||||No|3|T5PA400DW| |Rating|Lugs|Poles in Series|Catalog<br>number| |---|---|---|---| |400A|Yes|2+1<br>3|T5PB400DL<br>T5PA400DL| |400A|No|2+1<br>3|T5PB400DW<br>T5PA400DW| ## T5 - 400A Frame TMA, Thermal magnetic adjustable |IC at 1000VDC|Rating|Lugs|Poles in Series|Catalog<br>number| |---|---|---|---|---| |5kA|A|Y|2+1|T5PB400TL| ||400|es|3|T5PA400TL| |5kA|400A|No|2+1|T5PB400TW| ||||3|T5PA400TW| ## T6-D 800A Frame molded case switch |Rating|Lugs|Poles in Series|Catalog<br>number| |---|---|---|---| |600A||2+2|T6PB600DL-4| ||Yes|4|T6PA600DL-4| |800A||2+2|T6PB800DW-4| ||No|4|T6PA800DW-4| ## T6 - 800A Frame TMA, Thermal magnetic adjustable |IC at 1000VDC|Rating|Lugs|Poles in Series|Catalog<br>number| |---|---|---|---|---| |10kA|600A|Y|2+2|T6PB600TL-4| |||es|4|T6PA600TL-4| |10kA|800A|No|2+2|T6PB800TW-4| ||||4|T6PA800TW-4| ## T7-D 1000A Molded case switch |Rating|Lugs|Poles in Series|Catalog<br>number| |---|---|---|---| |1000A||2+2|T7MPB1000DL-4| ||Yes|4|T7MPA1000DL-4| NOTE: All poles in series is for use in grounded systems. 2+1 or 2+2 configurations are for ungrounded systems. 17.69 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## Tmax UL489B Jumper kit accessories ## T1-D **==> picture [345 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> Description Rating Poles in Series Catalognumber<br>JUMPER KIT T1PV 100A 4P 2+2PS LUG UL 2+2 KT1PB100-L<br>100A<br>JUMPER KIT T1PV 100A 4P 4PS LUG UL 4 KT1PA100-L<br>T4-D<br>Description Rating Poles in Series Catalognumber<br>JUMPER KIT T4PV 100A 3P 2+1PS LUG UL 2+1 KT4PB100-L<br>100A<br>JUMPER KIT T4PV 100A 3P 3PS LUG UL 3 KT4PA100-L<br>JUMPER KIT T4PV 200A 3P 2+1PS LUG UL 2+1 KT4PB200-L<br>200A<br>JUMPER KIT T4PV 200A 3P 3PS LUG UL 3 KT4PA200-L<br>**----- End of picture text -----**<br> ## T5-D **==> picture [345 x 195] intentionally omitted <==** **----- Start of picture text -----**<br> Description Rating Poles in Series Catalognumber<br>JUMPER KIT T5PV 400A 3P 2+1PS LUG UL 2+1 KT5PB400-L<br>JUMPER KIT T5PV 400A 3P 3PS LUG UL 3 KT5PA400-L<br>400A<br>JUMPER KIT T5PV 400A 3P 2+1PS BUS UL 2+1 KT5PB400-W<br>JUMPER KIT T5PV 400A 3P 3PS BUS UL 3 KT5PA400-W<br>T6-D<br>Description Rating Poles in Series Catalognumber<br>JUMPER KIT T6PV 600A 4P 2+2PS LUG UL 2+2 KT6PB600-L<br>600A<br>JUMPER KIT T6PV 600A 4P 4PS LUG UL 4 KT6PA600-L<br>JUMPER KIT T6PV 800A 4P 2+2PS BUS UL 2+2 KT6PB800-W<br>800A<br>JUMPER KIT T6PV 800A 4P 4PS BUS UL 4 KT6PA800-W<br>T7-D<br>Description Rating Poles in Series Catalognumber<br>JUMPER KIT T7PV 1000A 4P 2+2PS LUG UL 2+2 KT7PB1000-L<br>1000A<br>JUMPER KIT T7PV 1000A 4P 4PS LUG UL 4 KT7PA1000-L<br>**----- End of picture text -----**<br> NOTE: See pages 17.71-17.83 for additional electrical/mechanical accessories 17.70 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Accessories Electrical T1 - T7 **==> picture [19 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> KT3S4<br>**----- End of picture text -----**<br> T1 with KT3S4 T7 X1 Shunt trip - UVR ## Shunt trips -(Standard) 1 For remote opening of circuit breaker. Guaranteed operation for a voltage of between 75-110% of the rated power supply voltage. T1-T6 mounts in the left hand cavity cannot be used with UVR on 2-3P breakers |of the rated power supply voltage. T1-T6 mounts in the left hand cavity cannot be used with UVR on 2-3P<br>breakers|of the rated power supply voltage. T1-T6 mounts in the left hand cavity cannot be used with UVR on 2-3P|of the rated power supply voltage. T1-T6 mounts in the left hand cavity cannot be used with UVR on 2-3P|of the rated power supply voltage. T1-T6 mounts in the left hand cavity cannot be used with UVR on 2-3P| |---|---|---|---| |Frame Size|Voltage<br>~~|_|~~|Factory Installation1<br>~~|_|~~|Field Installation<br>~~|_|~~| |||Catalog number suffix<br>~~|_|~~|Catalog number<br>~~|_|~~| |T1-T3|480 - 500VAC<br>~~|_|~~|S1<br>~~|_|~~|KT3S1<br>~~|_|~~| ||220-250VAC/DC|S2|KT3S2| ||380 - 440VAC|S3|KT3S3| ||110 - 125VAC/DC|S4|KT3S4| ||48 - 60VAC/DC|S7|KT3S7| ||24 - 30VAC/DC|S8|KT3S8| ||12VDC|S9|KT3S9| |Ts3|480VAC/250VDC|S1|KTS3S1| ||240 VAC|S2|KTS3S2| ||120VAC/125VDC|S4|KTS3S4| ||48VDC|S7|KTS3S7| ||24VAC/VDC|S8|KTS3S8| ||12VDC|S9|KTS3S9| |T4, T5, T6<br>3|480-500VAC|S1|KT5S1| ||220/250VAC/DC|S2|KT5S2| ||380-440VAC|S3|KT5S3| ||110-125VAC/DC|S4|KT5S4| ||48-60VAC/DC|S7|KT5S7| ||24VAC/DC|S8|KT5S8| ||12VDC|S9|KT5S9| |T7|415-440VAC|S1|KT7XS1| ||380-400VAC|S2|KT7XS2| ||240-250VAC/DC|S3|KT7XS3| ||220-240VAC/DC|S4|KT7XS4| ||120-127VAC/DC|S5|KT7XS5| ||110-120VAC/DC|S6|KT7XS6| ||60VAC/DC|S7|KT7XS7| ||48VAC/DC|S8|KT7XS8| ||30VAC/DC|S9|KT7XS9| ||24VAC/DC|S0|KT7XS0| |Shunt trip connector(REQUIRED for Ts3) 2<br>Ts3<br>Fixed Mount2<br>Included when shunt<br>tripfactoryinstalled<br>Draw-out2<br>Included when shunt<br>tripfactoryinstalled<br>~~ee~~<br>~~ee~~|||Field Kit<br>KTS3C-SU| ||Draw-out2<br>~~ee~~|Included when shunt<br>tripfactoryinstalled<br>~~ee~~<br>~~ee~~|KTS3C-SUP| ## Shunt trips (Permanent Supply) 1 For remote opening of circuit breaker. Guaranteed operation for a voltage of between 75-110% of the rated power supply voltage. These shunt trips have much lower power consumption. |Frame Size|Voltage<br>~~|~~|FactoryInstallation1<br>~~|~~|Field Installation| |---|---|---|---| |||Catalognumber suffix<br>~~|~~|Catalognumber| |Ts3|24VDC<br>~~|~~|SA<br>~~|~~|KTS3SA| ||120VAC|SB|KTS3SB| |T4, T5, T63|24-30VDC|SA|KT5SA| ||110/120/VAC|SB|KT5SB| |Shunt trip connector(REQUIRED for Ts3) 2<br>Ts3<br>Fixed Mount2<br>Included when shunt<br>tripfactoryinstalled<br>Draw-out2<br>Included when shunt<br>tripfactoryinstalled|||Field Kit<br>KTS3C-SU| ||Draw-out2|Included when shunt<br>tripfactoryinstalled|KTS3C-SUP| > 1 For factory installation add suffix given to end of circuit breaker catalog number per accessory format. > 2 Must be ordered separately for field installation. 17.71 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A ## Accessories Electrical T1 - T7 Undervoltage release - UVR Will trip circuit breaker when connected voltage drops to 35-70% of the undervoltage release voltage rating. Will allow circuit breaker to close when voltage is approximately 85% of the rated voltage. T1-T6 mounts in the left hand cavity cannot be used with shunt trip on 2-3P breakers Factory Installation 1 Field Installation Frame Size Voltage Catalog numbersuffix Catalog number 480 - 500VAC U1 KT3U1 220-250VAC/DC U2 KT3U2 380 - 440VAC U3 KT3U3 T1-T3 110 - 125VAC/DC U4 KT3U4 60VAC/DC U5 KT3U5 48VAC/DC U7 KT3U7 24 - 30VAC/DC U8 KT3U8 480VAC U1 KTS3U1 KT3U2 240VAC U2 KTS3U2 24VAC U3 KTS3U3 120VAC U4 KTS3U4 Ts3 250VDC U5 KTS3U5 125VDC U6 KTS3U6 48VDC U7 KTS3U7 24VDC U8 KTS3U8 480-500VAC U1 KT5U1 220/250VAC/DC U2 KT5U2 380-440VAC U3 KT5U3 T4, T5, T6 110-125VAC/DC U4 KT5U4 60VAC/DC U5 KT5U5 48VAC/DC U7 KT5U7 T7 X1 Shunt trip - UVR 24VAC/DC U8 KT5U8 415-440VAC U1 KT7XU1 380-400VAC U2 KT7XU2 240-250VAC/DC U3 KT7XU3 220-240VAC/DC U4 KT7XU4 120-127VAC/DC U5 KT7XU5 T7 110-120VAC/DC U6 KT7XU6 60VAC/DC U7 KT7XU7 48VAC/DC U8 KT7XU8 30VAC/DC U9 KT7XU9 ~~a~~ 24VAC/DC U0 KT7XU0 Undervoltage trip connector (REQUIRED for Ts3) 2 Field Kit Included when Fixed Mount 2 under voltage factory KTS3C-SU installed Ts3 Included when under Plug-In/Draw-out 2 voltage factory KTS3C-SUP 17 installed _ ~~ee ee~~ 1 For factory installation add suffix given to end of circuit breaker catalog number per accessory format. 2 Must be ordered separately for field installation. 17.72 Low Voltagge Products & Systems 1SXU000023C0202 Rev. A Low Voltagge Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Accessories Electrical T1 - T7 17 ## Auxiliary contacts - AUX 1 Auxiliary contacts are for indication of the circuit breaker open-closed. Bell alarm contacts (BA) can be used to indicate circuit breaker tripped. **==> picture [39 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> T1 with K3TAS<br>**----- End of picture text -----**<br> |Auxiliary contacts are for indication of the circuit breaker open-closed. Bell alarm contacts (BA) can be<br>used to indicate circuit breaker tripped.|Auxiliary contacts are for indication of the circuit breaker open-closed. Bell alarm contacts (BA) can be<br>used to indicate circuit breaker tripped.|Auxiliary contacts are for indication of the circuit breaker open-closed. Bell alarm contacts (BA) can be|Auxiliary contacts are for indication of the circuit breaker open-closed. Bell alarm contacts (BA) can be| |---|---|---|---| |||Factory Installation<br>1|Field Installation| ||Frame Size|Catalog number<br>suffix|Catalog number| ||1 Form C + 1BA|A|KT3AS| |T1-T32<br>T2<br>Ts3|3 Form C + 1BA<br>A3<br>3 Form C + 1BA 24VDC<br>A3AU<br>T2 PR221DS 1 Form C + 1BA<br>A<br>2 Form C<br>A<br>1 Form C+ 1 BA<br>BA<br>~~a~~||KT3AS3<br>KT3AS3-AU<br>KT2AS-E<br>KTS3AS<br>KTS3BA| ||1 Form C + 1BA 250VAC/VDC|A|KT5AS| |T4, T5, T64|2 Form C 400VAC/250VDC<br>3 Form C + 1BA 250VAC/VDC|A2<br>A3|KT5AS2-B<br>KT5AS3| ||3 Form C + 1BA 24VDC|A3AU|KT5AS3-AU| ||1 Form C + 1BA 400VAC/250VDC|A|KT7AS| ||2 Form C 400VAC/250VDC|A2|KT7XAS2| |T7|1 Form C + 1BA 24VDC<br>2 Form C 24VDC|AAU<br>A2AU|KT7AS-AU<br>KT7XAS2-AU| ||3 Form C + 1BA 400VAC/250VDC|A3|KT7AS3| ||3 Form C + 1BA 24VDC|A3AU|KT7AS3-AU| |Auxiliary contact connector(REQUIRED for Ts3) 3<br>Ts3<br>Fixed Mount3||Included|Field Kit<br>KTS3C-AB| ||Plug-In /Drawout3|Included|KTS3C-ABP| KTS3AS > 1 For factory installation add suffix to end of breaker part number per accessory format . > 2 Not compatible for T2 with PR221DS trip unit. > 3 Must be ordered separately for field installation. 17.73 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A Accessories Motor operators T1 - T7 17 ## Electrical operators Allows remote opening and closing of circuit breaker Frame size Voltage Catalognumber ~~a~~ Solenoid operator 48 - 60VDC KT3M1 T1-T3 110 - 250VAC/DC KT3M2 Direct action motor operator iS ~~[ro]~~ 240VAC/250VDC120VAC/125VDC KTS3M2KTS3M4 Ts3 48VDC KTS3M7 24VDC KTS3M8 Motor operator connector (REQUIRED for Ts3) 1 KT3M1 Fixed Mount 1 KTS3C-M Ts3 Plug-In / Draw-out 1 KTS3C-MP Stored energy motor operator 220-250VAC/DC KT5M2 110--125-VAC/DC KT5M4 T4, T5 48-60VDC KT5M7 24VDC KT5M8 Contact for remote/manual operation ~~a~~ (stored energy operator) ~~— |~~ T4, T5, T6 - KT5MA Stored energy motor operator 220-250VAC/DC KT6M2 110--125-VAC/DC KT6M4 T6 48-60VDC KT6M7 24VDC KT6M8 380VAC KT6M3 **==> picture [20 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KT3M1<br>**----- End of picture text -----**<br> **==> picture [34 x 208] intentionally omitted <==** **----- Start of picture text -----**<br> |<br>KT5M2<br>]<br>KTS3M2<br>**----- End of picture text -----**<br> 1 Must be ordered separately for field installation. 17.74 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Accessories Trip units T4 - T7 **==> picture [466 x 188] intentionally omitted <==** **----- Start of picture text -----**<br> Frame Size Rating plug numberCatalog<br>Rating plugs (UL)<br>400A Rating plug KT7X0400RP<br>600A Rating plug KT7X0600RP<br>T7 800 Rating plug KT7X0800RP<br>1000A Rating plug KT7X1000RP<br>1200 Rating plug KT7X1200RP<br>Modules for T7 PR332 trip units<br>T7 Voltage module 2 PR330/VT7<br>Communication module (Modbus RTU) PR330/D-M<br>External units<br>Test and configuration unit 3 PR010/T<br>Trip coil test-all Tmax electronic trip unit except PR33* K7TUT<br>External Bluetooth communication module 1<br>BT030<br>Includes diagnostic software for Modbus / Bluetooth networks<br>Battery power supply unit 1 PR030/B<br>**----- End of picture text -----**<br> Not suitable for UL applications. T7 - Allows remote opening when used with PR330/D-M and shunt trip T7M - Allows remote opening and closing when used with PR330//D-M. shunt trip and closing coil ## Actuator module (IEC) |T7|Actuator module2|PR330/R-T7| |---|---|---| |Neutral current transformers(required for 4 wire ground fault systems)||| |T4|100A|KT4NCT-100| ||150A|KT4NCT-150| ||250A|KT4NCT-250| |T5|300A|KT5NCT-300| ||400A|KT5NCT-400| |T6|600A|KT6NCT-600| ||800A|KT6NCT-800| |Current sensor for external neutral||| |T7|400 - 1200A|KT7NCT| > 1 Always supplied with PR332/P trip unit. > 3 Factory installed only. 17.75 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A ## Technical data Shunt trips, Undervoltages T1 - T7 ## Standard shunt trip **==> picture [400 x 214] intentionally omitted <==** **----- Start of picture text -----**<br> Inrush Power Consumption<br>Voltage T1,T2,T3 Ts3 T4,T5,T6 T7<br>AC (VA) DC (W) AC (VA) DC (W) AC (VA) DC (W) AC (VA) DC (W)<br>12 VDC - 50 - 120 - 150 - -<br>24 VAC/DC - - 100 100 or 4 1 - - 300 300<br>24…30 VAC/DC 50 50 - - 150 150 - -<br>30 VAC/DC - - - - - - 300 300<br>48 VAC/DC - - - 120 - - 300 300<br>48…60 VAC/DC 60 60 - - 150 150 - -<br>60 VAC/DC - - - - - - 300 300<br>100…120 VAC/DC - - 100 or 4 1 - - - 300 300<br>120…127 VAC/DC - - - - - - 300 300<br>110…127 VAC 110…125 VDC 50 50 - 120 150 150 - -<br>220…240 VAC/DC - - - - - - 300 300<br>220…240 VAC 220…250 VDC 50 50 100 120 150 150 - -<br>240…250 VAC/DC - - - - - - 300 300<br>380…400 VAC - - - - - - 300 -<br>380…440 VAC 55 - - - 150 - - -<br>415…440 VAC - - - - - - 300 -<br>480 VAC - - 100 - - - - -<br>480…525 VAC 55 - - - 150 - - -<br>Opening Time (ms) 15 15 ≤15 ≤15 15 15 20 20<br>**----- End of picture text -----**<br> Permanent supply shunt trip |Voltage|T4,T5,T6<br>AC (VA)<br>DC (W)|T4,T5,T6<br>AC (VA)<br>DC (W)| |---|---|---| |24 VAC/DC<br>100…120 VAC|4<br>4|4<br>-| ## Undervoltage **==> picture [425 x 202] intentionally omitted <==** **----- Start of picture text -----**<br> Power consumption during permanent operation<br>Voltage T1,T2,T3 Ts3 T4, T5, T6 T7<br>AC (VA) DC (W) AC (VA) DC (W) AC (VA) DC (W) AC (VA) DC (W)<br>24 VAC/DC - - 6 3 - - 3.5 3.5<br>24…30 VAC/DC 1.5 1.5 - - 6 3 - -<br>30 VAC/DC - - - - - - 3.5 3.5<br>48 VAC/DC 1 1 6 3 6 3 - -<br>60 VAV/DC 1 1 - - 6 3 - -<br>110…120 VAC/DC - - 6 - - - 3.5 3.5<br>120…127 VAC/DC - - - - - - 3.5 3.5<br>110…127 VAC 110…125 VDC 2 2 - - 6 3 - -<br>220…240 VAC/DC - - - - - - 3.5 3.5<br>220…240 VAC 220…250 VDC 2.5 2.5 - 3 6 3 - -<br>220…250 VAC - - 6 - - - - -<br>17 240…250 VAC/DC - - - - - - 3.5 3.5<br>380…400 VAC - - - - - - 3.5 -<br>380…440 VAC 3 - - - 6 - - -<br>415 - 440 VAC - - - - - - 3.5 -<br>480…525 VAC 4 - - - 6 - - -<br>480 VAC - - 6 - - - - -<br>Opening Time (ms) 15 15 ≤18 ≤18 ≤25 ≤25 ≤25 ≤25<br>**----- End of picture text -----**<br> 1 Shunt trip permanent supply 17.76 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Technical data Electrical operators T1 - T6 ## Electrical operator, T1-T3 |Electrical operator,T1-T3|Electrical operator,T1-T3||| |---|---|---|---| |Rated Voltage||AC|DC| |||-|48…60| |||110...250|110...250| |OperatingVoltage||85…110% Un|| |Inrushpower absorption duringoperation||1800(VA)|1000(W)| |Power on stand by||< 100(mW)|| |Time|opening (s)<br>closing (s)|< 0.1<br>< 0.1|| |Minimum control impulse time on<br>openingand closing (ms)||>100|| This unit is permanently supplied on stand by, a control is applied by means of external contact in a low power circuit. Contact characteristics: Voltage AC/DC=24V Current 50 mA ## Electrical operator, T4-T5 |Electrical operatorT4-T5|Electrical operatorT4-T5||| |---|---|---|---| |,<br>Voltage||AC|DC| |||-|24| |||-|48…60| |||110…125|110…125| |||220-250|220-250| |||380|-| |OperatingVoltage||85…110%|| |Inrushpower consumption||≤ 300VA|≤ 300W| |In servicepower consumption||≤150VA|≤150W| |Duration|opening (s)<br>closing (s)<br>resetting (s)|1.5<br>< 0.1<br>3|| |Minimum duration of the opening and closing<br>command impulse(ms)||≥100|| ## Electrical operator, T6 ## Electrical operator, Ts3 |Electrical operator,Ts3|Electrical operator,Ts3||||Electrical operator,T6|Electrical operator,T6||| |---|---|---|---|---|---|---|---|---| |Rated Voltage||AC|DC||Voltage||AC|DC| |||-|24||||-|24| |||-|48…60||||-|48…60| |||120|125||||110-125|110-125| |||240|250||||220-250|220-250| |||440|-||||380|-| |OperatingVoltage||85…110 % Un|||OperatingVoltage||85…110%|| |Inrushpower absorption||500(VA)|500(W)||Inrushpower consumption||≤ 400VA|≤ 400W| |Servicepower absorption||350(VA)|350(W)||In servicepower consumption||≤150VA|≤150W| |Time constant(ms)||18|||Duration|opening (s)<br>closing (s)<br>resetting (s)|3<br>< 0.1<br>5|| |Duration|opening (s)<br>closing (s)|0.1<br>0.1||||||| |Minimum duration of the opening and closing<br>command impulse(ms)||≥150|||Minimum duration of the opening and closing<br>command impulse(ms)||≥100|| 17.77 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A **==> picture [37 x 32] intentionally omitted <==** **----- Start of picture text -----**<br> Tmax<br>MCCBs<br>**----- End of picture text -----**<br> ## Accessories Mechanical T1 - T7 ## Standard cable terminal **==> picture [27 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KT3100-3<br>**----- End of picture text -----**<br> |Frame|Wire Size|Catalog number<br>(set of 3)|Catalog number<br>(set of 4)| |---|---|---|---| |T1|14 AWG-1/0<br>~~a~~|Integral<br>~~a~~|Integral| |T2|14 AWG-1/0<br>~~a~~|KT2100-3<br>~~a~~|KT2100-4| |T3|14 AWG - 1/0|KT3100-3|KT3100-4| ||4 AWG - 300 kcmil|KT3225-3|KT3225-4| |Ts3|14-2|K3TA|K3TA-4| ||14-1/0|K4TB|K4TB-4| ||2-4/0|K4TC|K4TC-4| ||4-300 kcmil|K4TD|K4TD-4| |T4|14 AWG-1/0|KT4100-3|KT4100-4| ||6 AWG-350 kcmil|KT4250-3|KT4250-4| |T53|250 kcmil-500 kcmil|KT5300-3|KT5300-4| |T513|(2)3/0-250 kcmil|KT5400-3|KT5400-4| |T52|(2)3/0-500 kcmil|KT5600-3|—| |T6|(2)250-500 kcmil|K6TH|K6TH-4| |T61|(3)2/0-400 kcmil<br>~~[PT~~|K6TJ|K6TJ-4| |T71|(4)4/0-500 kcmil<br>~~[PT~~|KT7X1200-3|KT7X1200-4| Standard cable lug kits with power control taps **==> picture [29 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KT1HTC-3<br>**----- End of picture text -----**<br> |Frame|Wire Size|Catalog number<br>(set of 3)|Catalog number<br>(set of 4)| |---|---|---|---| |T3|14 AWG - 1/0|KT3100-3C|KT3100-4C| ||4 AWG - 300 kcmil|KT3225-3C|KT3225-4C| |Ts3|14 AWG-1/0|K4TBC|K4TBC-4| ||2 AWG-4/0|K4TCC|K4TCC-4| ||4 AWG-300 kcmil|K4TDC|K4TDC-4| |T4|14 AWG-1/0|KT4100-3C|KT4100-4C| ||6 AWG-350 kcmil|KT4250-3C|KT4250-4C| |T53|250 kcmil-500 kcmil|KT5300-3C|KT5300-4C| |T513|(2)3/0-250 kcmil|KT5400-3C|KT5400-4C| |T6|(2)250-500 kcmil|K6THC|K6THC-4| |T61|(3)2/0-400 kcmil|K6TJC|K6TJC-4| Terminal covers for fixed breakers - Low profile-kit includes two pieces **==> picture [14 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> 17<br>**----- End of picture text -----**<br> **==> picture [28 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KT4LTC-3<br>**----- End of picture text -----**<br> |Frame|Catalog number<br>(3 pole)|Catalog number<br>(4 pole)| |---|---|---| |T1|KT1LTC-3|KT1LTC-4| |T2|KT2LTC-3|KT2LTC-4| |T3|KT3LTC-3|KT3LTC-4| |Ts3|KTS3LTC-3|KTS3LTC-4| |T4|KT4LTC-3|KT4LTC-4| |T5|KT5LTC-3|KT5LTC-4| |T6|KT6LTC-3|KT6LTC-4| |T7|KT7XLTC-3|KT7XLTC-4| Terminal covers for fixed breakers - High profile-kit includes two pieces |Frame|Catalog number<br>(3pole)|Catalog number<br>(4pole)| |---|---|---| |T1|KT1HTC-3|KT1HTC-4| |T2|KT2HTC-3|KT2HTC-4| |T3|KT3HTC-3|KT3HTC-4| |Ts3|KTS3HTC-3|KTS3HTC-4| |T4|KT4HTC-3|KT4HTC-4| |T5|KT5HTC-3|KT5HTC-4| |T6|KT6HTC-3|KT6HTC-4| |T7|KT7XHTC-3|KT7XHTC-4| > 1 Comes standard with high profile terminal covers. > 2 Uses front extended spreaded terminals... refer to technical catalog. > 3 Not suitable for use on T5 600A. 17.78 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Accessories Mechanical T1 - T7 17 Phase barriers - Low profile 100mm-3.93 in **==> picture [93 x 82] intentionally omitted <==** **==> picture [24 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KT2EF-3<br>**----- End of picture text -----**<br> |Frame|4pcs(3p)|6pcs(4p)| |---|---|---| |T1-T3|KT3PBL-3|KT3PBL-4| |T4-T5|KT5PBL-3|KT5PBL-4| |T6|KT6PBL-3|KT6PBL-4| |T7|KT7PBL-3|KT7PBL-4| Phase barriers - High profile 200mm-7.87 in |Frame|4pcs(3p)|6pcs(4p)| |---|---|---| |T1-T3|KT3PBH-3|KT3PBH-4| |T4-T5|KT5PBH-3|KT5PBH-4| |T7|KT7PBH-3|KT7PBH-4| Saddle terminals for Copper Cables - IEC **==> picture [54 x 110] intentionally omitted <==** **==> picture [23 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> KT4EF-_<br>**----- End of picture text -----**<br> |Frame|Catalog number<br>(Set of 3)|Catalog number<br>(Set of 4)| |---|---|---| |T2|KT2100S-3|KT2100S-4| |T3|KT3225S-3|KT3225S-4| |Ts3|K4TES|K4TES-4| |T4|KT4250S-3|KT4250S-4| |T5|KT5300S-3|KT5300S-4| |Extended front terminals||| |Frame|Catalog number<br>(set of 3)|Catalog number<br>(set of 4)| |T1|KT1EF-3|KT1EF-4| |T2|KT2EF-3|KT2EF-4| |T3|KT3EF-3|KT3EF-4| |Ts3|KTS3EF-3|KTS3EF-4| |T4|KT4EF-3|KT4EF-4| |T5|KT5EF-3|KT5EF-4| Rear terminals 1 **==> picture [21 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> KT2R-3<br>**----- End of picture text -----**<br> |Frame|Catalog number<br>(set of 3)|Catalog number<br>(set of 4)| |---|---|---| |T2|KT2R-3|KT2R-4| |T3|KT3R-3|KT3R-4| |T4|KT4R-3|KT4R-4| |T5|KT5R-3|KT5R-4| |T6|KT6R-3|KT6R-4| |T7|KT7R-3|KT7R-4| ## Distribution cable lug kit 2 **==> picture [272 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> Frame Wire Size Catalog number Catalog number<br>(set of 3) (set of 4)<br>T3 (6) #14-6 KT3TN KT3TN-4<br>Ts3 (6) #14-6 KTS3TN KTS3TN-4<br>T4 (6) #14-6 KT4TN KT4TN-4<br>T5 (6 )#14-1/0 KT5TGD KT5TGD-4<br>**----- End of picture text -----**<br> 1 Includes low profile terminal cover. 2 Includes high profile terminal cover. 17.79 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 | ## Accessories Mechanical T1 - T7 ## Padlock locking device |Frame|Style|Locking Position|Breaker<br>Mounting|Catalog number| |---|---|---|---|---| |T1,T2,T3|PLL|OPEN/CLOSED|Fixed|KT3LD| |||OPEN||KT3LDO| |Ts3|FLD|OPEN|Fixed,Plug-In|KTS3FLD| ||||Draw-0ut|KTS3FLDW| |T4-T5|FLD|OPEN|Fixed,Plug-In|KT5FLD| ||||Draw-out|KT5FLDW| |T6|FLD|OPEN|Fixed,Plug-In|KT6FLD| ||||Draw-out|KT6FLDW| |T7|PLL<br>~~es~~|OPEN<br>~~es~~|Fixed,Drawout<br>~~es~~|KT7LDO| ## Keylocks-rotary handle mechanism |Frame|Style|LockingPosition|Keys|Catalognumber| |---|---|---|---|---| |T1,T2,T3<br>Ts3<br>T4-T5<br>T6|RHL<br>-<br>KLF-D<br>KLF-D|OPEN/CLOSED<br>OPEN<br>OPEN<br>OPEN|Different<br>Different<br>Different<br>Different|KT3RHL3<br>KTS3KLFD<br>KT5KLFD<br>KT6KLFD| |T7|KLF-D|OPEN|Different|KT7KLFD| ## Direct mount rotary operator handle **==> picture [20 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> KT5RH<br>**----- End of picture text -----**<br> |Frame|Breaker<br>Mounting|Catalog number| |---|---|---| |T1,T2,T3|Fixed,Plug-In|KT3RH| |Ts3|Fixed,Plug-In|KTS3RH| |Ts3|Draw-out|KTS3RHW| |T4-T5|Fixed,Plug-In|KT5RH| |T4-T5|Draw-0ut|KT5RHW| |T6|Fixed,Draw-out|KT6RH| |T6|Draw-out|KT6RHW| |T7|Fixed,Draw-out|KT7RH| ## Variable depth handle operators |Frame|NEMA rating|Mechanism<br>catalognumber|Shaft catalog number|Handle catalog<br>number| |---|---|---|---|---| |T1—T3|1,3R,12|—|—|OHB65J6<br>OHY65J6| ||4, 4X|KT3VD-M|OXP6X430 (16.9”)1|OHB80L6<br>OHY80L6| ||1|—|KT3VD-S(11.8”)|KT3VD-H| |Ts3|1,3R,12|—|OXP10X148 (5.8")1|OHB95J10<br>OHY95J10| ||4,4X|KTS3VD-M|OXP10X225 (8.9")|OHB95L10<br>OHY95L10| ||—|—|OXP10X500(19.7")|—| ||1|—|KTS3VD-S(20")|KTS3VD-H| |T4-T5|1,3R,12|—|OXP10X148 (5.8")|OHB95J10<br>OHY95J10| ||4,4X|KT5VD-M|OXP10X225 (8.9")|OHB95L10<br>OHY95L10| ||—|—|OXP10X500(19.7")|—| ||—|—|—|—| ||1|—|KT5VD-S(19.7")|KT5VD-H| |T6|1,3R,12|—|OXP10X148 (5.8")|OHB125J10<br>OHY125J10| ||4,4X|KT6VD-M|OXP10X225(8.9")|OHB125L10| ||—|—|OXP10X500(19.7")|—| ||1|—|KT5VD-S(19.7)|KT6VD-H| |T7|1,3R,12|—|OXP10X148 (5.8")|OHB175J10<br>OHY175J10| ||4,4X|KT7VD-M|OXP10X225(8.9")|OHB175L10| ||—|—|OXP10X500(19.7")|—| ||1|—|KT7VD-S(19.7")|KT7VD-H| 1 Discount schedule H6. 17.80 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Accessories Mechanical T1 - T7 ## Plug-in kits 1 KT2PFF + KT2PMK (on back of breaker) + breaker |Plug-in kits 1|||| |---|---|---|---| |Frame||Catalog number<br>Adapter moving part|Catalog number<br>fixedpart| |T2 - 3pole with front terminals||KT2PMK|KT2PFF| |T3 - 3pole with front terminals||KT3PMK|KT3PFF| |T2-T3 Fixedparts accept the same cable and rear terminal kits as the circuit breakers|t the same cable and rear terminal kits as the circuit breakers||| |Ts3 3pole with front terminals<br>Ts3 3pole with rear terminals||KTS3PMK|KTS3PFF<br>KTS3PFR| |T4 3pole with extended front terminal|||KT4PFEF| |T4 3pole with rear horizontal terminals||KT4PMK|KT4PFHR| |T4 3pole with rear vertical terminals|||KT4PFVR| |T5, 400A<br>T5 400A 3pole with extended front terminal|||KT5PFEF| |T5 400A 3pole with rear horizontal terminal||KT5PMK|KT5PFHR| |T5 400A 3pole with rear vertical terminal|||KT5PFVR| |T5, 600A<br>T5 600A 3pole with extended front terminal|||KT56PFEF| |T5 600A 3pole with rear horizontal terminal||KT56PMK|KT56PFHR| |T5 600A 3pole with rear vertical terminal|||KT56PFVR| ## Plug connectors, T1-T3 Required when adding accessories to plug-in breakers |Plug Connector|Catalog<br>number| |---|---| |Shunt tripor UVR|KT3PC-3| |1 form Cplus 1 BA|KT3PC-6| |3 form Cplus 1 BA|KT3PC-12| KT4PFVR ## Adaptors, T4-T6 Required when adding accessories to plug-in or drawout breakers KT4PMK (on back of breaker) |Adaptors|Catalog<br>number| |---|---| |1 form Cplus 1 BA|KT5ADP-6| |Shunt trip/UVR|KT5ADP-5| |Stored energyoperator|KT5ADP-10| |Stored energyoperatorplus shunt trip/UVR|KT5ADP-10| |3 form Cplus 1BA|KT5ADP-12| ## Testing extension, T4 - T6 |Testing extension, T4 - T6|| |---|---| |Extension|Catalog<br>number| |5pin for blank tests w/service release|KT5EXT-5| |6 pin for blank tests w/aux contacts (1+1)<br>service and residual current releases|KE5EXT-6| |10 pin for blank tests w/motor operator and<br>earlycontacts|KT5EXT-10| |12pin for blank tests w/aux contacts(3+1)|KT5EXT-12| > 1 Plug connectors (T2-T3), Adaptors (T4-T5), required when adding accessories to plug-in breakers. 17.81 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A Accessories T1 - T7 ## Draw-out kits 1 **==> picture [58 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> KT4WMK (on back of<br>breaker)<br>**----- End of picture text -----**<br> **==> picture [28 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KT5WFVR<br>**----- End of picture text -----**<br> |Draw-out kits 1||| |---|---|---| |Item|Catalog number<br>Adaptor moving part|Catalog Number<br>Fixedpart| |Ts3 3 pole with front terminals<br>Ts3 3pole with rear terminals|KTS3WMK|KTS3WFF3<br>KTS3WFR3| |T4 3 pole with extended front terminal<br>T4 3 pole with rear horizontal terminals<br>T4 3 pole with rear vertical terminals<br>T5 3 pole with extended front terminal<br>T5 3 pole with rear horizontal terminal<br>T5 3 pole with rear vertical terminal<br>T5 3 pole with extended front terminal, 600A<br>T5 3 pole with rear horizontal terminal, 600A<br>T5 3pole with rear vertical terminal,600A|KT4WMK<br>KT5WMK<br>KT56WMK|KT4WFEF<br>KT4WFHR<br>KT4WFVR<br>KT5WFEF<br>KT5WFHR<br>KT5WFVR<br>KT56WFEF<br>KT56WFHR<br>KT56WFVR| |T6 3 pole with extended front terminal<br>T6 3 pole with rear horizontal terminal<br>T6 3pole with rear vertical terminal|KT6WMK|KT6WFEF3<br>KT6WFHR3<br>KT6WFVR| |T7 3pole with horizontal/vertical terminals|KT7XWMK|KT7WFHR2| ## Adaptors — T4-T6 Required when adding accessories to plug-in or drawout breakers |Adaptors|Catalog<br>number| |---|---| |1 form C plus 1 BA<br>Shunt trip/UVR<br>Stored energy operator<br>Stored energy operator plus shunt trip/UVR<br>3 form Cplus 1BA|KT5ADP-6<br>KT5ADP-5<br>KT5ADP-10<br>KT5ADP-10<br>KT5ADP-12| Sliding contact blocks — T7-Draw-out Item Moving Part Fixed Part Breaker Cradle Left Block Spring charging motor Spring charged contact Ready to close contact KT7XSCMP-L KT7SCFP-L Early auxiliary contact Contact for trip coil release trip Trip rest Center Block PR331 KT7XSCMP-C KT7XSCFP-C PR332 Right Block 17 Auxiliary contacts Shunt trip KT7XSCMP-R KT7XSCFP-R Closing Coil “ ~~_~~ Undervoltage release If at least one of the accessories in table is installed on the breaker - respective pair of contact blocks must be installed on the fixed part (cradle) and the moving part. (breaker) Position key lock — T7 - T7M-X1 Item Catalog number Key #20005 KT7XPL2 Different key KT7XPL1 ~~—,_—=~~ Locks drawout breaker in racked-in / test isolation / racked-out position. Position key lock accessory — T7 - T7M-X1 Item Catalog number ~~|~~ Key lock accessory KT7XPLA Accessory added to position key lock allows breaker to be locked in racked-out position only. 1 Adaptors (T4-T6), Sliding contact blocks (T7) required when adding accessories to draw-out breakers. 2 Comes standard with horizontal terminals field convertible to vertical 3 IEC 17.82 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Accessories T1 - T7 17 ## DIN rail adapters |Mechanical interlocks|| |---|---| |T1-T3<br>Slidingbar interlock-front mounted(2 Breakers)|Catalog Number| ||KT3MIF2| |Slidingbar interlock-front mounted(3 Breakers)<br>~~a~~|KT3MIF3<br>~~a~~| |T3<br>Rear Interlock-horizontal<br>~~a~~|KT3MI-H<br>~~a~~| |Rear Interlock-vertical<br>~~a~~|KT3MI-V<br>~~a~~| |TS3<br>Horizontal|KTS3MI-H| |Vertical|KTS3MI-V| |T4-T5 1<br>Interlock frame<br>Mechanical Interlock frame-horizontal|KT5MIR-HB| |Mechanical Interlock frame-vertical|KT5MIR-VB| |Plate type<br>A T4(F-P-W)T4(F-P-W)|KT5MIR-PA| |B T4(F-P-W)T5 400(F-P-W)OR T5 600(F)|KT5MIR-PB| |C T4(F-P-W)T5 600(P-W)|KT5MIR-PC| |D T5(F-P-W)T5 400(F-P-W)OR 630(F)|KT5MIR-PD| |E T4(F-P-W)T5 600(P-W)|KT5MIR-PE| |F T4(F-P-W)T5 600(P-W)|KT5MIR-PF| |T6<br>Horizontal|KT6MI-H| |Vertical|KT6MI-V| |T7 2<br>Cable T7-X1|KT7XMLC| |Mech. interlockplate-fixed|KT7XMLPF| |Mech. interlockplate-draw-out|KT7XMLPW| Flange cable mechanisms ~~EEE~~ Item Catalog Number Handles |Handles<br>~~EEE~~|Item<br>~~EEE~~|Catalog Numberg NumberNumber<br>~~EEE~~| |---|---|---| |T1 - T3|NEMA 1,3R,12<br>NEMA 4,4X|OHF1C12T<br>OHF1C4T| |Ts3 - T5|NEMA 1,3R,12<br>NEMA 4,4X|OHF1C12<br>OHF1C4| |Mechanisms<br>T1 - T2||MKCT2| ||T3|MKCT3| ||T4 - Ts3|MKCT4| ||T5|MKCT5| |Cables|36”|OXC1L36| ||48”|OXC1L48| ||60”|OXC1L60| ||72”|OXC1L72| ||84”|OXC1L84| ||96”|OXC1L96| ||108”|OXC1L108| > 2 To interlock two circuit breakers, you have to order a cable kit and two plates. 1 T4-T5 Complete assembly consists of one interlock frame and one plate. 17.83 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A ## Approximate dimensions T1 & T2 17 T1 — 3 pole **==> picture [117 x 169] intentionally omitted <==** **==> picture [239 x 159] intentionally omitted <==** **==> picture [134 x 178] intentionally omitted <==** T1 — Single pole **==> picture [367 x 228] intentionally omitted <==** **----- Start of picture text -----**<br> T2 — 2 & 3 pole<br>83<br>78<br>90<br>30 30 70<br>¯ 9.38<br>Y<br>76.2<br>X X<br>Y<br>>3 < 2<br>103<br>65 53.25<br>17<br>181 130<br>45 106.5<br>**----- End of picture text -----**<br> **==> picture [76 x 79] intentionally omitted <==** 17.84 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Approximate dimensions T3 17 T3 — 2 & 3 pole **==> picture [152 x 184] intentionally omitted <==** **==> picture [207 x 167] intentionally omitted <==** Door cut-out for Tmax without faceplate **==> picture [103 x 84] intentionally omitted <==** 17.85 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Approximate dimensions Ts3 17 **==> picture [466 x 597] intentionally omitted <==** 17.86 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Approximate dimensions T4 17 ## **Fixed circuit breaker** ## **Caption** - 1 Overall dimensions with cabled accessories mounted (SOR-C, UVR-C, RC221-222) - 2 Overall dimensions with cabled auxiliary contacts mounted (only 3Q 1SY) **==> picture [48 x 50] intentionally omitted <==** **==> picture [40 x 47] intentionally omitted <==** ## **Flange for compartment door** ## **Drilling templates of the compartment door** **==> picture [167 x 24] intentionally omitted <==** **----- Start of picture text -----**<br> 3-4 POLES 3-4 POLES<br>With flange Without flange<br>**----- End of picture text -----**<br> ## **Drilling templates for support sheet** For front terminals ## For rear terminals **==> picture [70 x 107] intentionally omitted <==** **==> picture [81 x 104] intentionally omitted <==** **==> picture [29 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 3 POLES<br>**----- End of picture text -----**<br> **==> picture [29 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 4 POLES<br>**----- End of picture text -----**<br> 17.87 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A Approximate dimensions T5 17 ## Fixed circuit breaker **==> picture [52 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Fixing on sheet<br>**----- End of picture text -----**<br> ## Caption - 1 Overall dimensions with cabled accessories mounted (SOR-C, UVR-C, RC221-222) - 2 Overall dimensions with cabled auxiliary contacts mounted (only 3Q 1SY) **==> picture [39 x 38] intentionally omitted <==** **==> picture [67 x 42] intentionally omitted <==** ## Flange for compartment door ## Drilling templates of the compartment door Drilling templates for support sheet For front terminals For rear terminals **==> picture [78 x 100] intentionally omitted <==** **==> picture [29 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 3 POLES<br>**----- End of picture text -----**<br> **==> picture [29 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 4 POLES<br>**----- End of picture text -----**<br> **==> picture [29 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 3 POLES<br>**----- End of picture text -----**<br> **==> picture [29 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 4 POLES<br>**----- End of picture text -----**<br> 17.88 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Approximate dimensions T6 17 **==> picture [491 x 570] intentionally omitted <==** 17.89 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A Approximate dimensions T7 17 **==> picture [490 x 605] intentionally omitted <==** 17.90 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Approximate dimensions T7M Fixed, 3 Pole, front terminals **==> picture [35 x 83] intentionally omitted <==** **==> picture [56 x 51] intentionally omitted <==** **==> picture [40 x 51] intentionally omitted <==** **==> picture [81 x 94] intentionally omitted <==** **==> picture [75 x 74] intentionally omitted <==** 17.91 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A Approximate dimensions T8, Fixed, 3 pole, front terminals 1600A, 2000A, 2500A **==> picture [67 x 47] intentionally omitted <==** **==> picture [83 x 116] intentionally omitted <==** 17 17.92 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 Approximate dimensions T8, Fixed, Vertical rear terminals 80% rated 3000A; 100% rated 2500A, 3000A **==> picture [82 x 96] intentionally omitted <==** 17.93 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 ## Approximate dimensions T8, Fixed, Optional vertical rear terminals (KT82500VR-x) 1600A/2000A/2500A **==> picture [32 x 45] intentionally omitted <==** **==> picture [85 x 99] intentionally omitted <==** 17.94 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 17 Approximate dimensions T1 - T3 ## Variable depth mechanism with OHB handle **==> picture [84 x 100] intentionally omitted <==** **==> picture [50 x 105] intentionally omitted <==** **==> picture [101 x 102] intentionally omitted <==** **==> picture [37 x 83] intentionally omitted <==** **==> picture [39 x 60] intentionally omitted <==** **==> picture [39 x 91] intentionally omitted <==** **==> picture [155 x 130] intentionally omitted <==** 17.95 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 ## Approximate dimensions Ts3 ## Variable depth mechanism with OHB handle **==> picture [37 x 38] intentionally omitted <==** 17.96 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage Approximate dimensions T4 - T5 Variable depth mechanism with OHB handle 17 **==> picture [37 x 34] intentionally omitted <==** **==> picture [89 x 125] intentionally omitted <==** **==> picture [88 x 99] intentionally omitted <==** 17.97 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A 17 **==> picture [37 x 32] intentionally omitted <==** **----- Start of picture text -----**<br> Tmax<br>MCCBs<br>**----- End of picture text -----**<br> ## Approximate dimensions T6 Variable depth mechanism 17.98 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage ## Approximate dimensions T7 Variable depth mechanism **==> picture [14 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> 17<br>**----- End of picture text -----**<br> 17.99 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A Notes 17 17.100 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
Updated at February 9, 2023
ABB is a global leader in power and automation technologies, recognized for delivering innovative solutions that improve performance while minimizing environmental impact. Serving a diverse range of sectors including industrial processing, OEM, and building services, ABB provides highly reliable components designed to meet the rigorous demands of modern electrical systems. The company is particularly renowned for its advanced circuit protection solutions. This includes a comprehensive selection of thermal magnetic circuit breakers, alongside specialized RCBO, RCD, GFCI, and AFDD circuit breakers. These foundational safety components are supported by a wide array of high-quality fuse holders and circuit breaker accessories, ensuring complete protection for complex industrial and commercial installations. Beyond circuit protection, ABB excels in automation and process control. Their offering features sophisticated visual signal indicator units, industrial switch accessories, and panel instrumentation designed for intuitive system monitoring. Additionally, ABB manufactures a robust range of power relays, safety relays, and AC/DC converters, providing engineers with the critical building blocks needed for efficient, secure, and reliable control panels.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →