T11-311-2
CIRCUIT BREAKER, THERMAL, 1P, 240V, 2A
- Manufacturer: SCHURTER
- Product type: Thermal Circuit Breakers
- ; CIRCUIT BREAKER, THERMAL, 1P, 240V, 2A; Product Range:T11 Series; Current Rating:2A; No. of Poles:1 Pole; Voltage Rating VDC:48VDC; Voltage Rating VAC:240VAC; Circuit Breaker Moun
- No. of Poles: 1 Pole
- Current Rating: 2A
- Voltage Rating VAC: 240V
- Voltage Rating VDC: 48V
- Circuit Breaker Mounting: Panel
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 8.41 € |
| Current stock | 50+ |
| Lead time | 30 days |
**Thermal (T- and TA-Line)** www.schurter.com/PG17_18_19 T11-811 Circuit Breaker for Equipment thermal, Drop-in type, Reset type, Quick connect terminals ## **Description** - Drop-in type - Thermal circuit breaker - 1-pole - Reset type - Positively trip-free release - Quick connect terminals 6.3 x 0.8 mm ## **Standards** - IEC 60934 - UL 1077 ## **Applications** - Power tools - Household Equipment - Power supplies and chargers - Industrial appliances ## **Weblinks** pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for product, Product News - CSA C22.2 235 - GB 17701 |**Technical Data**||| |---|---|---| |Rated Voltage AC|240 V; 50/60 Hz|| |Rated Voltage DC|48 V|| |Rated current range AC|0.05-16 A|| |Conditional short circuit ca-|IEC: Inc, PC1, AC 240V: 2kA|| |pacity||| |Short circuit capacity Icn|at In < 6.5 A/240 VAC : 8 x In|| |at In≥6.5 A/240 VAC : 96 A||| |Degree of Protection<br>Dielectric Strength<br>Insulation resistance<br>Endurance typical<br>Endurance minimum|from front side IP 40 acc. to IEC 60529<br>50 Hz: > 1.5 kV<br>Impulse 1.2/50μs: > 2.5 kV<br>500 VDC > 100 MΩ<br>2 x Ir: 500 switching cycles<br>Reset type<br>AC : 2 x Ir , cosφ0.6 :|from front side IP 40 acc. to IEC 60529| ||DC : 2 x Ir , L/R = 2 - 3 ms :|| ||50 switching cycles|| |Overload|IEC: min. 40 trips| |---|---| ||@ 6 x Ir, cosφ0.6| |UL / CSA: min. 50 trips|| ||@ 1.5 x Ir, cosφ0.75| |Ambient temperature|-5°C to 60°C| |Vibration Resistance|± 1.5 mm @ 10 - 60 Hz| ||acc. to IEC 60068-2-6, test Fc| ||5 G @ 60 - 500 Hz| ||acc. to IEC 60068-2-6, test Fc| |Shock Resistance|100 G / 6 ms| ||acc. to IEC 60068-2-27, test Ea| |Tripping Type|Thermal| |Actuation type|Reset type| |Weight|ca. 10 g| Circuit Breakers **1** **Thermal (T- and TA-Line)** www.schurter.com/PG17_18_19 T11-811 ## **Dimension** **==> picture [487 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> T11-811 <7,5A T11-811 >7,5 A T11-811N<br>**----- End of picture text -----**<br> **==> picture [500 x 268] intentionally omitted <==** **----- Start of picture text -----**<br> 3<br>1 2<br>9 10 Ø 4<br>11<br>19<br>15.2<br>6.3<br>11.5 9.0<br>4<br>48.2<br>34.5<br>44<br>9.2<br>**----- End of picture text -----**<br> **==> picture [72 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Diagrams<br>Rated current ≤ 7,5 A<br>**----- End of picture text -----**<br> **==> picture [316 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> ≤ 7,5 A Rated current >7,5 A Shunt terminal T11-...N ≤ 6,5 A<br>1 1 1<br>2 3 2 3<br>**----- End of picture text -----**<br> Circuit Breakers **2** **Thermal (T- and TA-Line)** www.schurter.com/PG17_18_19 T11-811 ## **Typical internal resistance** **==> picture [172 x 236] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Current [A] Internal Resistance [ Ω ]<br>0.05 380.000<br> 0.50 5.200<br> 1.00 1.350<br> 2.00 0.300<br> 3.00 0.130<br> 4.00 0.080<br> 5.00 0.040<br> 6.00 0.040<br> 7.00 0.020<br> 8.00 0.012<br> 9.00 0.012<br> 10.00 0.011<br> 11.00 0.0095<br> 12.00 0.0095<br> 13.00 0.0085<br> 14.00 0.0085<br> 15.00 0.0075<br> 16.00 0.0075<br>**----- End of picture text -----**<br> ## **Time-Current-Curves** **==> picture [201 x 249] intentionally omitted <==** **----- Start of picture text -----**<br> [ min ] [ sec ]<br>10`000<br>< 6,5 A<br>60 > 6,5 A<br>30 2`000<br>20<br>1`000<br>10<br>500<br>5<br>200<br>100<br>1<br>50<br>20<br>10<br>5<br>2<br>1<br>0,5<br>0,3<br>0,2<br>0,1<br>1,05 1,35 2 3 4 5 8 10<br>Multiple of Rated Current In<br>Time in Seconds<br>**----- End of picture text -----**<br> Reference Temperature +23° Circuit Breakers **3** **Thermal (T- and TA-Line)** www.schurter.com/PG17_18_19 T11-811 ## **Effect of ambient temperature** The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: **==> picture [314 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> Ambient temperature [°C] Correction factor<br>-5 0.87<br>0 0.90<br>+10 0.95<br>+23 1.00<br>+30 1.04<br>+40 1.10<br>+50 1.15<br>+60 1.20<br>**----- End of picture text -----**<br> Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor = 1.1; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A ## **Config. Code** ## ~~T11~~ ~~**|** -~~ ~~**|** 1~~ ~~**|** 2~~ ~~**|** 3~~ ~~**|** A~~ ~~**|** B~~ ~~**|** -~~ ~~**|** 1.23~~ ~~**|**~~ The characters are placeholders for the correspondingly keys of selections from the key tables. **==> picture [520 x 471] intentionally omitted <==** **----- Start of picture text -----**<br> T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Mounting Rated current Configuration<br>key<br>Mounting Configuration 0.3 A 0.3<br>key<br>0.4 A 0.4<br>Drop-in type 8<br>0.5 A 0.5<br>0.6 A 0.6<br>T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Actuation type 0.7 A 0.7<br>0.8 A 0.8<br>Actuation type Configuration<br>key 0.9 A 0.9<br>1.0 1<br>Reset type 1<br>1.1 A 1.1<br>1.2 A 1.2<br>T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Terminal 1.3 A 1.3<br>1.4 A 1.4<br>Terminal Configuration<br>key 1.5 A 1.5<br>Quick connect terminal 6.3x0.8mm 1 1.6 A 1.6<br>1.7 A 1.7<br>1.8 A 1.8<br>T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Shunt terminal<br>1.9 A 1.9<br>Shunt terminal Configuration 2.0 A 2<br>key<br>2.1 A 2.1<br>Shunt terminal N<br>2.3 A 2.3<br>2.5 A 2.5<br>T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Setting indication 2.8 A 2.8<br>3.0 A 3<br>Setting indication Configuration 3.3 A 3.3<br>key<br>3.5 A 3.5<br>Setting indication R<br>4.0 A 4<br>4.5 A 4.5<br>T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Rated current 5.0 A 5<br>5.5 A 5.5<br>Rated current Configuration<br>key 6.0 6<br>0.05 A 0.05 6.5 A 6.5<br>0.1 A 0.1 7.0 A 7<br>0.15 A 0.15 7.5 A 7.5<br>0.2 A 0.2 8.0 A 8<br>Other rated currents on request 8.5 A 8.5<br>**----- End of picture text -----**<br> Other rated currents on request Circuit Breakers **4** **Thermal (T- and TA-Line)** www.schurter.com/PG17_18_19 T11-811 **==> picture [511 x 94] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Rated current|Configuration|Rated current|Configuration| |key|key| |9.0 A|9|13.0 A|13| |9.5 A|9.5|14.0 A|14| |10.0 A|10|15.0 A|15| |11.0 A|11|16.0 A|16| |12.0 A|12|Other rated currents on request| |Other rated currents on request| **----- End of picture text -----**<br> ## **Variants** **==> picture [343 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Rated current|Construction variants|Config. Code|Order Number| |Shunt terminal|Setting indication| |3.0 A|T11-811-3|4400.0112| |5.0 A|T11-811-5|4400.0114| |5.5 A|T11-811-5.5|4400.0120| |2.5 A|T11-811-2.5|4400.0178| |6.0|T11-811-6|4400.0179| |Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/| |Stock-Check-SCHURTER| **----- End of picture text -----**<br> **Packaging Unit** 1 Pcs ## **Accessories** ## **Description** T-Linie Zubehör Accessories to T-Line The specifications, descriptions and illustrations indicated in this document are based on current ~~information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.~~ Circuit Breakers **5**
Updated at June 5, 2026
SCHURTER is a globally recognized innovator and manufacturer of high-quality electronic components, specializing in products that ensure a safe and clean supply of power. With a strong reputation in the electronics and PCB assembly industries, the company delivers reliable solutions engineered to protect critical circuits, streamline device operation, and optimize electrical performance across diverse applications. The core of our SCHURTER portfolio revolves around comprehensive circuit protection. We carry an extensive selection of standard and resettable fuses, accompanied by robust fuse holders, to safeguard sensitive electronics against overcurrent conditions. Furthermore, our offering features high-performance thermal circuit breakers and associated accessories, providing dependable protection and rapid reset capabilities for demanding industrial and commercial environments. Beyond fundamental circuit protection, SCHURTER excels in electromagnetic compatibility (EMC) and RFI suppression technologies. Our range includes precision-engineered power line filters and common mode chokes designed to mitigate electromagnetic interference and ensure signal integrity. Accompanied by specialized components such as AC/DC LED power supplies, SCHURTER provides the meticulous engineering and durability necessary for modern, high-reliability electronic design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →