Image not available
Illustrative purposes only
SPD122401C
DIN RAIL MOUNT AC - DC CONVERTERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type:
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 431.84 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Switching Power Supply Type SPD 240W Compact DIN rail mounting** - **Universal AC input full range** - **Installation on DIN rail 7.5 or 15mm** - **Short circuit protection** - **Active PFC as standard** - **High efficiency up to 93%** - **Power ready output** - **LED indicator for DC power ON** - **LED indicator for DC low** - **Parallel connection feature** - **Compact dimensions** - **UL, cUL listed and TUV/CE approved** - **150% peak load capability** **Product Descri tion Orderin Ke p g y SP D 24 240 1C X** The Switching power installation is on a DIN rail **Model** ~~ee~~ supplies SPD series are and compact dimensions **Mounting (D = Din rail)** specially designed to be and performance are a must. **Output voltage** used in all automation **Output power** application where the **Input type Optional features** ~~il~~ **Input type:** 1C = single phase Compact version ## **A rovals pp** ## **O tional features p** **Description Code** Screw terminal Nil ~~ha~~ \\ Plug-in connectors B **Out ut Performance p** |**MODEL NO.**<br>**INPUT**<br>**VOLTAGE**<br>~~ss~~|**MODEL NO.**<br>**INPUT**<br>**VOLTAGE**<br>~~ss~~|**MODEL NO.**<br>**INPUT**<br>**VOLTAGE**<br>~~ss~~|**OUTPUT**<br>**POWER**|**OUTPUT**<br>**VOLTAGE**|**OUTPUT**<br>**CURRENT**|**EFF.**<br>**(min.)**|**EFF.**<br>**(typ.)**| |---|---|---|---|---|---|---|---| ||||**Single Output Models**||||| ||**SPD 12 240 1C X**|88~264 VAC|192 WATTS|+12 VDC|16A|89%|91%| ||**SPD 24 240 1C X**|88~264 VAC|240 WATTS|+ 24 VDC|10A|91%|93%| **Output Data (All specifications are at nominal values, full load, 25°C unless otherwise noticed)** |**Line regulation**||± 1%| |---|---|---| |**Load regulation**<br>**Minimum load**||±1%<br>0%| |**Turn on time**||| |**Vi nom, Io nom**||1000ms(full resistive load)| |||1500ms with**7000**µF CAP| |**Transient recovery time**<br>**Ripple and noise**||2ms<br>100mVpp| |**Output voltage accuracy**||0% ~ +1%| |**Hold up time**|**Vi= 115VAC**|25ms| ||**Vi= 230VAC**|30ms| |**Voltage fall time **|**(I0nom, Vi nom)**150ms|150ms| |**Voltage rise time**||| |**Vi nom, Io nom**||150ms(full resistive load)| |**Voltage trim range**<br>**12V Model**||500ms with**7000**µF CAP<br>11.4-14.5 VDC| ||**24V Model**|22.5-28.5 VDC| |**Rated continuous loading**||| ||**12V Model**|16A@12VDC/13A@14.5VDC| ||**24V Model**|10A@24VDC/8.4A@28.5VDC| |**Reverse voltage**||| |---|---|---| ||**12V Model**|18VDC| ||**24V Model**|35VDC| |**Capacitor load**|**acitor load**|7000µF| |**Temperature coefficient**||±0.03°C| |**DC ON** indicator threshold at start up||**VDC**| |(Green LED)||**Min.**<br>**Max.**| |**Vi nom, Io nom**|**12V Model**|10<br>11.2| ||**24V Model**|17.6<br>19.4| |**DC LOW** indicator threshold at start up||**VDC**| |(Red LED)||**Min.**<br>**Max.**| |**Vi nom, Io nom**|**12V Model**|10<br>11.2| ||**24V Model**|17.6<br>19.4| |**Parallel operation**||0.1 lo min~0.9 lo max For| |||parallel operation, turn the| |||Switch S/P Single/Parallel to| |||the position ”P” in advance.| |||Max 3 units and power out| |||90%| **1** Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 06/07/2017 |Switching Power Supply| |---| |Type SPD 240W Compact| |DIN rail mounting| |**Input Data(All specifications are at nominal values, full load, 25°C unless otherwise noticed)**| |**Rated input voltage Inom**<br>100 - 240VAC<br>**Voltage range**<br>**AC IN**<br>88 - 264VAC<br>**DC IN**<br>120 - 375VDC<br>**Rated input current**<br>**Vi: 88VAC** **Io nom**<br>3.2A Max.<br>**Vi: 115VAC** **Io nom**<br>2.3A Typ.<br>**Vi: 230VAC** **Io nom**<br>1.15A Typ.<br>**Inrush current**<br>**Vi= 115VAC**24A<br>**Vi= 230VAC**48A<br>**Power dissipation**<br>(Vi : 230VAC, Io nom) **12V Model**<br>19W<br>**24V Model**<br>18W<br>**Frequency range **<br>47- 63Hz<br>**Leakage current**<br>**Input-Output**<0.25mA<br>**Input-FG**<br><3.5mA<br>**P.F.C. (Active)**<br>0.97@Vi:230VAC, Io nom<br>~~se~~| |**Controls and Protections(All specifications are at nominal values, full load, 25°C unless otherwise noticed)**| |**Overload Vi nom**<br>(see typcurrent limited curve)<br>120% - 150%<br>**Input fuse**<br>T5A/250VAC internal1)<br>**Output short circuit**<br>Shut-down protection,<br>after 7s auto-restart<br>**Over voltage protection**<br>**VDC**<br>(Auto recovery)<br>**Min.**<br>**Max.**<br>**12V Model**<br>15<br>16.5<br>**24V Model**<br>30<br>33<br>**Internal surge voltage**<br>**protection**IEC 61000-4-5<br>Varistor<br>1)Fuse not replaceable by user<br>**Power RDY**(for 24V model only)<br>Threshold voltage<br>of contact closed (at start up)<br>17.6 - 19.4VDC<br>**Electrical isolation**<br>500VDC<br>**Over temperature**<br>Detect on heat sink, shut down<br>O/P voltage, recovers automatically<br>after temperaturegoes down<br>100 - 110°C<br>**Rated over load protection**<br>**Vi nom**(see typ current limited curve)120 - 150%<br>~~ii~~| |**General Data(All specifications are at nominal values, full load, 25°C unless otherwise noticed)**| |**Ambient temperature**<br>-40°C to + 71°C<br>**Derating (+61°C to + 71°C)**<br>2.5%/°C(see curve)<br>**Relative humidity**<br>20 ~ 95%RH<br>**Storage temperature**<br>-40°C to +85°C<br>**Protection degree**<br>IP20<br>**Cooling**<br>Free air convection<br>**Insulation voltage**<br>**Input-Output**3000VAC/4242VD min<br>**Input-Fg**<br>1500VAC/2121VD min<br>**Insulation resistance I/O**<br>100MΩ min(@ 500VDC)<br>**Switching Frequency**<br>90 Khz Typ<br>**Pollution degree**<br>2<br>**MTBF**(Bellcore issue 6 @ 40°C, GB)<br>**12V Model**<br>374000 Hours<br>**24V Model**<br>384000 Hours<br>**Case material**<br>Metal<br>**Altitude**<br>4850m<br>**Dimensions LxWxD mm(inch)**<br>**Screw terminal type**<br>124.5(4.9)x64(2.52)x123.6(4.87)<br>**Detachable connector type **<br>143.5(5.65)x64(2.52)x123.6(4.87)<br>**Weight**<br>860g<br>**Packing**<br>960g<br>~~a~~| |**Norms and Standards**| |**Vibration resistance**<br>meet IEC 60068-2-6<br>(Mounting by rail: Random<br>wave, 10-500 Hz, 2G each<br>long Z, Y, Z axes<br>10 min/cycle,60min.)<br>**Shock resistance**<br>meet IEC 60068-2-27<br>(4G, 22ms, 3 Axis, 6 faces,<br>3 times for each face)<br>**UL/cUL**<br>UL 508 Listed<br>UL 60950-1 Recognized<br>**TUV**<br>EN 60950-1<br>EN 21558-1<br>EN 6155-8-2-16<br>**CE**<br>EN 61000-6-3,<br>EN 55037 Class B,<br>EN 61000-3-2,<br>EN 61000-3-3,<br>EN 61000-6-2,<br>EN 55024,<br>EN 61000-4-2 level 4,<br>EN 61000-4-3 level 3<br>EN 61000-4-4 level 4<br>EN 61000-4-5 L-N level 3<br>EN 61000-4-6 level 3<br>EN 61000-4-8 level 4<br>EN 61000-4-11,<br>ENV 50204 Level 2<br>~~=~~| |Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 06/07/2017<br>**2**| Switching Power Supply Type SPD 240W Compact DIN rail mounting ## **Block Diagram** **==> picture [396 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> L Fuse Inrush Current Vo+<br>N |! Filter RectifierLimiter& PFC Switching Device Rectifier DetectionCurrent | Vo-<br>| Y PWM<br>| Controller Opto- Reference &<br>Isolation Error Amp. VoutADJ<br>I |<br>|<br>| Opto- Error amp [|]<br>| Isolation &<br>| OVP [|]<br>|<br>|| OutputLevel [|] DC ON(green LED)<br>ee| Detection | DC LOW(red LED)RDY<br>(relay Contact)<br>**----- End of picture text -----**<br> ## **Pin Assi nement and Front Controls g** ~~Pee~~ **Pin No. Designation Description** ~~—~~ **1** A normal open relay contact for DC ON level control **RDY 2** Never connect except 24V model ~~| Pee~~ **3. 4 V+** Positive output terminal ~~Pee~~ **5. 6 V-** Negative output terminal ~~Oe~~ **7** Ground this terminal to minimize high-frequency emissions ~~Pee~~ **8 N** Input terminals (neutral conductor, no polarity at DC input) ~~Pee~~ **9 L Input terminal (phase conductor, no polarity at DC input)** ~~Pee~~ **LED DC ON Operation indicator LED** ~~ee~~ **LED DC LO DC LOW voltage indicator LED** ~~nnn nInIInIIIIIINIIIInIIIIIIININIINIIIIIIIIIINI PF~~ **Trimmer Vout ADJ. Trimmer-potentiometer for Vout adjustment** ~~Pf~~ **Switch S/P Single / Parallel select switch** ## **Deratin Curve g** ## **T . Efficienc curve yp y** **==> picture [218 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> 100 NN<br>75<br>0<br>-40 61 71<br>Temperature (°C)<br>Power out (%)<br>**----- End of picture text -----**<br> **==> picture [217 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> 95<br>Le<br>90<br>eeny ee<br>85 ns ee<br>80 aAe ee<br>Zs ee 230 VAC<br>75 i 115 VAC<br>a<br>ee es es<br>70 es<br>10 25 50 75 100<br>Power out (%)<br>EFFICIENCY (%)<br>**----- End of picture text -----**<br> **3** Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 06/07/2017 Switching Power Supply Type SPD 240W Compact DIN rail mounting ## **T . Current Limited Curve yp** **==> picture [403 x 123] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>75<br>50 Continuous For 3 sec OCP<br>25<br>0<br>100 110 120 130 140 150 160<br>Power out (%)<br>Output Voltage (%)<br>**----- End of picture text -----**<br> ## **Peak Loadin g** **==> picture [378 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> 360W<br>Auto recover within 7 sec<br>3s 3s<br>240W<br>Continuous OCP OCP<br>Protect 7s 7s<br>**----- End of picture text -----**<br> ## **Mechanical Drawings mm (inches)** **==> picture [187 x 204] intentionally omitted <==** **----- Start of picture text -----**<br> Screw Detachable<br>64 (2.52)<br>64 (2.52)<br>6 1<br>6 1<br>DC OUTPUT<br>SP - - + + Rdy SP - - + + Rdy<br>Vout ADJ Vout ADJ<br>DC LO DC LO<br>DC ON DC ON<br>N L N L<br>AC INPUT<br>7 9 7 9<br>116.6 (4.56) 7.0 (0.28)<br>124.5 (4.9) 124.5 (4.9)<br>143.5 (5.65)<br>**----- End of picture text -----**<br> ## **Installation** **Ventilation and cooling** Normal convection. All sides 25mm free space for cooling is recommended **Connector size range Screw terminals:** AWG24-10 (0.2~4mm²) flexible / solid cable, - Input Terminals max. torque at 1.16Nm (9 pound-inches). - Output Terminals max. torque at 0.616Nm (5.5 pound-inches). 8mm stripping at cable end recommends. **Detachable connectors:** AWG24-12 (0.2~2.5 mm²) flexible / solid cable, - Input Terminals max. torque at 0.51 Nm (4.5 pound-inches). - Output Terminals max. torque at 0.79 Nm (7 pound-inches). 4~5mm stripping at cable end recommends. Use copper conductors only, 60/75°C. ## **Parallel Connection** **==> picture [133 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> N<br>PS1 PS2 PS3<br>+ - + - + -<br>+ -<br>LOAD<br>**----- End of picture text -----**<br> **4** Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 06/07/2017
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →