Image not available
Illustrative purposes only
SPD05601
DIN RAIL MOUNT AC - DC CONVERTERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type:
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 119.1 € |
| Current stock | 25+ |
| Lead time | 30 days |
## **Switching Power Supply Type SPD 60W DIN rail mounting** - **Universal AC input full range** - **Installation on DIN rail 7.5 or 15mm** - **Short circuit protection** - **Overload protection** - **Class 2 output** - **High efficiency** - **LED indicator for DC power ON** - **Power Ok output** - **CE, TUV approved and cULus Listed** **Product De scri tion p** The Switching power DIN rail and compact supplies SPD series are ~~—___——~~ dimensions and performance specially designed to be used are a must. in all automation application where the installation is on a **Orderin Ke g y SP D 24 60 1 B Model** ~~——~~ **Mounting ( D = Din rail ) Output voltage Output power Input Type Optional features** **Input type: 1= single phase** ## **A rovals pp** **==> picture [23 x 27] intentionally omitted <==** **----- Start of picture text -----**<br> Product SafetyRheinland<br>p<br>t g<br>p<br>r<br>a<br>a e<br>r<br>u pr<br>e o<br>a ü<br>p v<br>B f<br>y<br>t<br>T ed<br>**----- End of picture text -----**<br> **O tional Features p** Description Code Spring connectors B = ~~—_________~~ ## **Out ut Performances p** |**Model**|**Rated output**<br>**Voltage (VDC)**|**Output**<br>**Power (W)**|**Output**<br>**Current (A)**|**Voltage Trim Range**|**Voltage Trim Range**|**DC ON green LED at start up**<br>**DC LOW red LED after start up**|**DC ON green LED at start up**<br>**DC LOW red LED after start up**|**Typical**<br>**Efficiency**| |---|---|---|---|---|---|---|---|---| |||||**Min. VDC**|**Max. VDC**|**Min. VDC**|**Max. VDC**|| |SPD05|5|50|10.0|5|5.5|3.5|4.5|79%| |SPD12|12|60|5.0|12|14|9.0|10.8|86%| |SPD24|24|60|2.5|24|28|18|21.6|89%| |SPD48|48|60|1.25|48|55|37|43|89%| ## **Out ut Data p** |**Line regulation**<br>± 0.5%|**Rated continuous loading**|| |---|---|---| |**Load regulation**<br>± 0.5%<br>**Minimum load(A)**<br>0|**5V Model**<br>**12V Model**<br>**24V Model**|10A @ 5VDC/9.0A @ 5.5VDC<br>5A @ 12VDC/4.25A @ 14VDC<br>2.5A @ 24VDC/2.1A @ 28VDC| |**Turn on time(full resistive load)**<br>1000ms max|**48V Model**|1.25A @ 48VDC/1.08A @ 55VDC| |**Transient recovery time**<br>2ms<br>**Ripple and noise BW = 20MHz**<br>50mVpp<br>**Output voltage accuracy**<br>± 1% max.<br>**Temperature coefficient**<br>± 0.03%/°C|**Reverse voltage**<br>**5V Model**<br>**12V Model**<br>**24V Model**<br>**48V Model**|7.5VDC<br>18VDC<br>35VDC<br>63VDC| |**Hold up time**<br>**Vi= 115VAC** 20ms<br>**Vi= 230VAC** 30ms<br>**Voltage fall time (I0nom)**<br>150ms max|**Capacitor load**<br>**Voltage rise time at**<br>**full resistive load**|7000μF<br>150ms max| **1** Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 09/06/15 Switching Power Supply Type SPD 60W DIN rail mounting ## **Input Data** |**Rated input voltage**|100 - 240VAC| |---|---| |**Voltage range**<br>**AC**|85 - 264VAC| |**DC**<br>**Rated input current**<br>**(Vi : 115VAC)**<br>**(Vi : 230VAC)**|90 - 375VDC<br>1060mA<br>590mA| |**Input current(Vi : 85VAC)**<br>**Inrush current**<br>**Vi= 115VAC**|1500mA<br> 20A| |**Vi= 230VAC**|40A| |**Power dissipation**|| |---|---| |**(Vi : 230VAC, Io nom)**|| |**5V Model**|12.5W| |**12V Model**|9.0W| |**24V Model**|8.8W| |**48V Model**|7.8W| |**Frequency range**|47- 63Hz| |**Leakage current**|| |**Input-Output**|0.25mA| |**Input-FG**|3.5mA| ## **Controls and Protections** |**Overload**|110 – 150%| |---|---| |**Input fuse**<br>**Output short circuit**|T2A/250VAC internal1)<br>Fold forward| |**Power ready output (Rdy)**|| |**(only SPD 24)**<br>**On threshold**|Vout > 19,2V ± 2%| |**Off threshold**|Vout < 19,1V ± 2%| |1) Fuse not relaceable b user|| > 1) Fuse not replaceable by user |**Over voltage protection**||**VDC**|| |---|---|---|---| ||**Min.**||**Max.**| |**5V Model**|6.0||6.8| |**12V Model**|15||16.5| |**24V Model**|30||33| |**48V Model**|60||66| |**Internal surge voltage protection**||Varistor|| |**(IEC 61000-4-5)**|||| ## **General Data (@ nominal line, full load, 25°C )** |**Ambient temperature**|-40°C to 71°C| |---|---| |**Derating (>61°C to +71°C)**<br>**Ambient humidity**|2.5%/°C<br>20 ~ 95%RH| |**Storage temperature**|-40°C to +85°C| |**Protection degree**|IP20| |**Cooling**|Free air convection| |**Insulation voltage**|| |**Input-Output** <br>**Input-FG**<br>**Insulation resistance I/O**|3.000VAC/4242VDC min<br>1.500VAC/2121VDC min<br>100MΩ min (@ 500VDC)| |**MTBF(Bellcore issue 6 @ 40°C, GB)**|| |---|---| |**5V Model**|498000 Hours| |**12V Model**|504000 Hours| |**24V Model**|520000 Hours| |**48V Model**|531000 Hours| |**Case material**|Plastic: PC,UL94-V0| |**Pollution degree**|2| |**Altitude**|2000m| |**Dimensions LxWxD mm(inch)**|90(3.60)x40.5(1.59)x114(4.49)| |**Weight**|340g| ## **Norms and Standards** |**Vibration resistance**|meet IEC 60068-2-6|**CE**|EN 61000-6-3, EN 55022| |---|---|---|---| ||(Mounting by rail: 10-500Hz,||Class B, EN 61000-3-2,| ||2G, along X, Y, Z each Axis,||EN 61000-3-3,| ||60 min for each Axis)||EN 61000-6-2,| |**Shock resistance**|meet IEC 60068-2-27||EN 55024,| |**UL / cUL**|(15G, 11ms, 3 Axis, 6 faces,<br>3 times for each face)<br>UL508 listed, UL60950-1,<br>UL1310 Class 2 Power<br>(only 5V, 12V w/o Class 2)<br>Recognized, ISA 12.12.01<br>(Class 1, Division 2,<br>Groups A,B,C and D)||EN 61000-4-2 Level 4,<br>EN 61000-4-3 Level 3,<br>EN 61000-4-4 Level 4,<br>EN 61000-4-5 L-Level 3,<br>L/N-FG Level 4,<br>EN 61000-4-6 Level 3,<br>EN 61000-4-8 Level 4,<br>EN 61000-4-11,<br>ENV 50204 Level 2,| |**TUV**|EN 60950-1, CB scheme||EN 61204-3| ||EN 61558-1,EN 61558-2-16||| ||(meet EN 60204)||| |**CCC**|GB4943, GB9254, GB17625.1||| **2** Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 09/06/15 Switching Power Supply Type SPD 60W DIN rail mounting ## **Block Diagrams** **==> picture [453 x 390] intentionally omitted <==** **----- Start of picture text -----**<br> L Fuse Vo +<br>Inrush Current<br>FilterLine Limiter andRectifier SwitchingDevice Rectifier<br>N Vo -<br>PWM<br>Controller<br>Opto - Reference &<br>Isolation Error Amp.<br>Vout<br>Y ADj.<br>Opto - Over Voltage<br>Isolation Detection<br>Y<br>Y DC ON<br>Output Level (Green LED)<br>Detection RDY<br>aaRot (Open Collector)<br>Pin Assi nement and Front Controls<br>g<br>Pin No. Designation Description<br>1 RDY DC OK, output for relay (only on SPD 24)<br>2 + Positive output terminal<br>3 + Positive output terminal<br>4 - Negative output terminal<br>5 - Negative output terminal<br>6 GND Ground terminal to minimise High frequency emissions<br>7 L Phase input ( no polarity with DC input )<br>8 N Neutral input ( no polarity with DC input )<br>Pot1 Vout ADJ. Trimmer for fine output voltage adjustment<br>L1 DC ON DC output ready LED<br>**----- End of picture text -----**<br> ## **Out ut Rd Wirin Dia ram p y g g** ## **Derating Diagram** **==> picture [452 x 201] intentionally omitted <==** **----- Start of picture text -----**<br> RL > 700ohm<br>Rdy 100<br>-Vout 75<br>a ) Relay<br>2.2K<br>Rdy<br>0.5W<br>5.1K<br>0<br>0.3W<br>-40 61 71<br>-Vout 1<br>b ) 5V signal Temperature (%)<br>Power out (%)<br>**----- End of picture text -----**<br> **3** Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 09/06/15 Switching Power Supply Type SPD 60W DIN rail mounting ## **T . Current Limited Curve yp** **==> picture [495 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> SPD 60W - 24V<br>**----- End of picture text -----**<br> ## **Mechanical Drawings mm (inches)** **==> picture [96 x 207] intentionally omitted <==** **==> picture [101 x 210] intentionally omitted <==** **==> picture [210 x 167] intentionally omitted <==** ## **T . Efficienc Curve yp y** **==> picture [242 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> 95<br>90<br>85<br>80<br>75<br>70<br>65<br>60<br>55<br>230 VAC<br>50 115VAC<br>45<br>40<br>10 25 50 75 100<br>Power out (%)<br>EFFICIENCY (%)<br>**----- End of picture text -----**<br> ## **Installation** **Ventilation and cooling** Normal convection All sides 25mm free space for cooling is recommended **Connector size range Spring terminal** AWG24-14 (0.2~2mm[2] ) flexible/solid cable, 10mm stripping at cable and recommends use copper conductors only, 60/75°C **Screw terminal** AWG26-12 (0.2~2.5mm[2] ) flexible/solid cable, connector can withstand torque at max 0,56Nm (5 lbs-in). 4~5 mm stripping at cable and recommends use copper conductors only, 60/75°C **Max. torque for terminal Input terminals** 0.56Nm (5.0lb-in) **Output terminals** 0.56Nm (5.0lb-in) **General tolerances mm(in.) 0.00 (0.00) ÷ 30.00 (1.18)** ±0.30 (0.01) **30.00 (1.18) ÷ 120.00 (4.72)** ±0.50 (0.02) **4** Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 09/06/15
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →