Image not available
Illustrative purposes only
SLB65S48C
AC/DC Open Frame Power Supply (PSU), ITE, Industrial & Medical, 1 Output, 65 W, 80V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SL POWER / ADVANCED ENERGY
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: SLB65 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.35A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 65W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 19.31 € |
| Current stock | 25+ |
| Lead time | 30 days |
## **SL POWER SLB65 SERIES** 65 Watts Single Output Medical & Industrial Grade Advanced Energy’s SL Power SLB65 medically-approved AC-DC power supplies are available with a nominal main output of 5 V, 12 V, 15 V, 18 V, 24 V, or 48 V. SLB65 power supplies provide up to 65 Watts convection. All models have output overvoltage, short circuit and overload protection and a small 2 x 3 x 1.2 inch form factor. ## **AT A GLANCE** ## **Total Power** **65 Watts** **Input Voltage** **80 to 264 VAC** **# of Outputs** **Single** ## **SPECIAL FEATURES** - 65 Watts Convection - Small 2” x 3” x 1.2” Form Factor ## **SAFETY** - UL/CSA/IEC/IEC60601-1, 3rd. Ed. - UL/CSA/IEC62368-1 - Universal Input 80 to 264 VAC - For 1U Applications - 2 x MOPP Isolation - Meets Heavy Industrial/4th Edition EMC - -20OC To 70OC Operating Temperature Range - 3 Years Warranty ©2022 Advanced Energy Industries, Inc. **SLB65** ## **ELECTRICAL SPECIFICATIONS** **==> picture [478 x 457] intentionally omitted <==** **----- Start of picture text -----**<br> Input<br>Input ra nge 80 to 264 VAC, 47 to 63 Hz, 1Ø<br>Input current 1.0 A max at 230 VAC<br>Inrush current 85 A max., cold start @ 264 VAC input, 25OC<br>Input fuses 3.15 A, 250 VAC<br>Leakage current<br>Earth <500 μA @ 264 VAC, 60 Hz, NC<br>Patient <100 μA @ 264 VAC, 60 Hz<br>Efficiency (typ. @ 25OC )<br>SLB65S12x, SLB65S15x 89% @ 230 VAC, 86.5% @ 115 VAC, full load<br>SLB65S18x 89% @ 230 VAC, 87.0% @ 115 VAC, full load<br>SLB65S24x 89% @ 230 VAC, 87.0% @ 115 VAC, full load<br>SLB65S48x 88% @ 230 VAC, 88% @ 115 VAC, full load<br>Isolation voltage Input/Ground: 1500 VAC (1 MOPP)<br>Input/Output: 4000 VAC (2 MOPP)<br>Output/Ground: 1500 VAC<br>Output<br>Maximum power Max of 65 Watts for convection cooled. See "Ordering information" section.<br>0.5% RMS, 1% to 1.5% pk-pk for all models. (20 MHz bandwidth, differential mode. Measured with noise<br>Ripple and noise<br>probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors)<br>Total regulation ±2% ( Maximum deviation from nominal voltage for all loading conditions)<br>Minimum load Not required<br>Overshoot <5% overshoot at turn-on, <5% overshoot at turn-off, under all conditions<br>500 μs response time for return to within 0.5% of final value for a 50% load step change, ∆ i/ ∆ t<0.2 A/μs. Max.<br>Transient response voltage deviation is ±3.5%, @ 25OC<br>Hold-up time 12 ms typical from loss of AC input at 115 VAC<br>Turn on time <2 s @ 115 VAC (<3 s for 12 V output model)<br>Cooling Convection (65 W Output)<br>Reliability<br>MTBF >500K hours, 25°C, full rated load (Calculation is done based on Telcordia reports )<br>Warranty 3 years<br>Protection<br>Overvoltage protection 115% to 130% of nominal output voltage. Requires AC recycle to reset. Latch mode.<br>Short circuit protection Short across the output terminals will not cause damage to the unit. Hiccup mode.<br>Thermal protection Will shutdown upon an over temperature condition. Auto-recovery mode.<br>Overload protection 120% to 180% of rated output current value. Hiccup mode.<br>**----- End of picture text -----**<br> **2 advancedenergy.com** **SLB65** ## **DERATING CURVES** ## **EMI/EMC COMPLIANCE** |Conducted emissions|EN55011/22 Class B; FCC Part 15, EN55015/CISPR15:2013, CISPR22 2006 Class B, CISPR32 Class B,<br>FCC Part 15.107, Class B: at 115 and 230 Vac| |---|---| |Radiated emissions|EN55011/22 Class A; FCC Part 15, CISPR15 radiated EN55032/CISPR22 Class B, CISPR32 Class B, FCC<br>Part 15.109, Class B: at 115 and 230 Vac| |Harmonic current emissions|EN61000-3-2, Class A, B, C & D| |Voltage fluctuations & flicker|IEC61000-3-3| |Electro static discharge immunity|EN61000-4-2, Level 4: 8kV contact, 15kV air, Criteria A| |Radiated RF fields susceptibility|EN61000-4-3, Level 3 (3V/m), Criteria A. EN55032/EN61000-4-3, 10V/m, 80MHz to 2.7GHz, 80% AM at<br>1kHz, IEC60601-1-2, 4th Edition, Table 4| |Electrical fast transients / bursts|EN61000-4-4, Level 3 (PS: 2kV-40A, other lines 1kV-20A), Criteria A, EN55024/IEC61000-4-4, Level 4, ±4kV,<br>100Khz rep rate, 40A, Criteria A, IEC60601-1-2, 4th Edition, Table 5| |Surge susceptibility|EN61000-4-5, Installation Class 3 (1kV diff. mode, 2kV common mode), Criteria A, EN55024/IEC61000-4-5,<br>Level 4, ±2kV DM, ±4kV CM, Criteria A, Surpasses IEC60601-1-2, 4th Edition requirements.| |Conducted RF susceptibility|EN61000-4-6, Level 3 (3Vrms), Criteria A, EN55032/IEC61000-4-6, 3V/m – Level 4, 0.15 to 80Mhz; and<br>12V/m) in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz, IEC60601-1-2, 4th<br>Edition, Table 5.| |Rated power frequency magnetic<br>fields test|EN61000-4-8, Level 3 (3A/m), Criteria A, EN55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz, IEC60601-1-2,<br>4th Edition, Table 4| |Voltage Sags & Surges|EN61000-4-11, 95% dip/0.5 cycle (Criteria A), 60%/5 cycles (Criteria B), 30%/25 cycles (Criteria A), Loading<br>is 70% of 100W with 100VAC<br>EN55024/IEC/EN61000-4-11:<br>--100% dip for 10 ms, at 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315°<br>--100% dip for 20 ms, 0°, Criteria A<br>--100% dip for 5000 ms (250/300 cycles), Criteria B<br>--60% dip for 100 ms, Criteria B<br>--30% dip for 500 ms, Criteria A<br>IEC60601-1-2, 4th Edition, Table 5| Notes: Performance criteria are based on EN55024. According to the standards, performance criteria are decoded as following: - A. Normal performance during and after the test - B. Temporary degradation, self-recoverable - C. Temporary degradation, operator intervention required to recover the operation - D. Permanent damage **advancedenergy.com 3** **SLB65** ## **ENVIRONMENTAL SPECIFICATIONS** **==> picture [479 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> Vibration Random vibration per MIL-STD-810E, Method 514.4, Cat. 1, Figure 514.4-1, 1 hr in each of three axes<br>Shock Non-operating: Half-sine, 40 gpk, 10ms, 3 axes, 6 shocks total<br>Cooling Convection<br>Operating temperature -20°C to +70°C<br>Temperature derating 40% derating at 70°C<br>Storage temperature -40°C to +85°C<br>Altitude Operating: 500 to 5,000 m. Non-operating: 500 to 40,000 ft<br>Relative humidity 5% to 95%, non-condensing<br>**----- End of picture text -----**<br> ## **ORDERING INFORMATION** **==> picture [478 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> Model Output Output Output Total OVP<br>Ripple & Noise<br> Number Voltage Current Power Regulation Threshold<br>SLB65S05x 5 V 8.0 A 40 W ±2% 7.9 ± 1.1V 0.5%RMS, 1.5% pk-pk<br>SLB65S12x 12 V 5.0 A 60 W ±2% 14.0 ± 1.1V 0.5%RMS, 1.5% pk-pk<br>SLB65S15x 15 V 4.0 A 60 W ±2% 18.0 ± 1.5V 0.5%RMS, 1.0% pk-pk<br>SLB65S18x 18 V 3.3 A 60 W ±2% 21.0 ± 3.0V 0.5%RMS, 1.0% pk-pk<br>SLB65S24x 24 V 2.71 A 65 W ±2% 28.0 ± 4.0V 0.5%RMS, 1.0% pk-pk<br>SLB65S48x 48 V 1.35 A 65 W ±2% 55.0 ± 4.0V 0.5%RMS, 1.0% pk-pk<br>**----- End of picture text -----**<br> Notes: Replace the "x" at the end of the model number with "C" for class II (ungrounded) input or replace with "K" for class I (grounded) input. ## **SAFETY** |UL/CSA/Demko|EN/CSA/UL/IEC 60601-1 3rd edition BF Rated & EN62368-1| |---|---| |CB report|Yes| |Isolation type|Double/Reinforced between input and output| ## **PIN ASSIGNMENTS** **==> picture [478 x 123] intentionally omitted <==** **----- Start of picture text -----**<br> Connector SLB65 Mating Connector Mating Pin<br>PIN 1 AC Line<br>J1 (Input connector) PIN 2 SPARE AMP: 640250-3 AMP: 640252-2<br>PIN 3 AC Neutral<br>PIN 1 +Vo<br>PIN 2 +Vo<br>J2 (Output connector) AMP: 640250-4 AMP: 640252-2<br>PIN 3 RTN<br>PIN 4 RTN<br>- -<br>G1 (Ground) Ring type terminal or similar<br>**----- End of picture text -----**<br> **4 advancedenergy.com** **SLB65** ## **MECHANICAL DRAWING** Notes: 1. All dimensions in inches (mm). **advancedenergy.com 5** **==> picture [596 x 270] intentionally omitted <==** ## **ABOUT ADVANCED ENERGY** Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. ## **TRUST** For international contact information, visit advancedenergy.com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2023 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, and AE® are U.S. trademarks of Advanced Energy Industries, Inc. ENG-SLB65-12.1 8 .2 3
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →