Image not available
Illustrative purposes only
SLB350S48K
AC/DC Open Frame Power Supply (PSU), 7.3A @ 200LFM, ITE & Industrial, 1 Output, 350W @ 200LFM
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SL POWER / ADVANCED ENERGY
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: SLB350 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 4.1A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Industrial
- Power Rating (Forced Cooling): 350W @ 200LFM
- Power Rating (Convection Cooling): 200W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 76.42 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **SL POWER SLB350 SERIES** 350 Watts Single Output Industrial Grade Advanced Energy’s SL Power SLB350 AC-DC power supplies are available with a nominal main output of 12 V, 24 V, 48 V or 56 V. SLB350 power supplies provide up to 350 Watts with air flow. All models have output overvoltage, short circuit and overload protection and a 3 x 5 x 1.5 inch form factor. ## **AT A GLANCE** ## **Total Power** **350 Watts** ## **Input Voltage** **85 to 264 VAC** ## **SPECIAL FEATURES** ## **SAFETY** **# of Outputs** - 200 Watts Convection up to 60OC - EN/CSA/IEC/UL62368-1 **Single** - 350 Watts with 200 LFM Airflow up to 60OC - 3” x 5” x 1.5” Form Factor - Universal Input 85 to 264 VAC - For 1U Applications - Class B Conducted and Radiated EMI - 3 Years Warranty - RoHS Compliant ©2025 Advanced Energy Industries, Inc. **SLB350** ## **ELECTRICAL SPECIFICATIONS** **==> picture [478 x 404] intentionally omitted <==** **----- Start of picture text -----**<br> Input<br>Input ra nge 85 to 264 VAC, 47 to 63 Hz, 1Ø<br>Input current 4.0 A max at 115 Vac, 2.0 A at 230 Vac.<br>Earth leakage current <300 μA @ 264 VAC, 60 Hz, NC; <600 μA SFC<br>Inrush Current 40 A peak maximum @ 264 VAC, cold start<br>Efficiency 90% typical<br>Isolation voltage Input/Output: 4000 VAC<br>Input/Ground: 1800 VAC<br>Output/Ground: 500 VAC<br>Output<br>Maximum power Max of 200 Watts for convection cooled, 350 Watts with 200 LFM air flow. See "Ordering Information" section<br>for specific voltage model ratings<br>Output voltage See "Ordering Information" section<br>Voltage adjustability Fixed output<br>1% pk-pk for all models. See "Ordering Information" section for details. (20 MHz bandwidth, differential mode.<br>Ripple and noise Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and<br>10μF low ESR capacitors)<br>Total regulation ±2% (combined line, load and initial setting)<br>Minimum load Not required<br>Switching frequency PFC: 50 kHz to 200 kHz. Main Converter: variable 70 kHz to 100 kHz<br>500 μs response time for return to within 0.5% of final value for a 50% load step change, ∆ i/ ∆ t<0.2 A/μs. Max.<br>Transient response<br>voltage deviation is ±3%<br>Hold-up time > 24 ms at full load 350 W, 100 VAC, 60Hz<br>Turn on time <3 s @ 115 VAC, full load<br>Reliability<br>MTBF 250K hours, 50°C, 115 VAC<br>Protection<br>Overvoltage protection 115% to 140% of nominal output voltage. Recycle AC input to reset.<br>Short circuit protection Short across the output terminals will not cause damage to the unit. Hiccup mode. Auto recovery.<br>Thermal protection Will shutdown upon an over temperature condition. Auto recovery.<br>Overload protection 130% to 180% of rated output current value. Hiccup mode.<br>**----- End of picture text -----**<br> ## **ENVIRONMENTAL SPECIFICATIONS** **==> picture [479 x 98] intentionally omitted <==** **----- Start of picture text -----**<br> Vibration Per IEC 60068-2-6<br>Shock Per IEC 60068-2-27<br>Operating temperature -10°C to +70°C. (Derating above 60°C see derating curves)<br>Temperature derating See derating curves<br>Storage temperature -40°C to +85°C<br>Altitude Operating: -500 to 15,000 ft (5000 m). Non-operating: -500 to 40,000 ft<br>Relative humidity 5% to 95%, non-condensing<br>**----- End of picture text -----**<br> **2 advancedenergy.com** **SLB350** ## **DERATING CURVE** **==> picture [119 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> ORDERING INFORMATION<br>**----- End of picture text -----**<br> |**Model Number**|**Output Voltage**|**With Air Flow**|**With Air Flow**|**Convection**|**Convection**| |---|---|---|---|---|---| |||**Output Current**|**Output Power**|**Output Current**|**Output Power**| |SLB350S12K|12 V|25.0 A|300 W|12.0 A|180 W| |SLB350S24K|24 V|14.6 A|350 W|8.3 A|200 W| |SLB350S48K|48 V|7.30 A|350 W|4.1 A|200 W| |SLB350S56K|56 V|6.25 A|350 W|3.6 A|200 W| **advancedenergy.com 3** **SLB350** ## **EMI/EMC COMPLIANCE** **==> picture [479 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> Conducted emissions EN55015/CISPR15:2013, EB55032:2015 CISPR22 2006 Class B, FCC Part 15.107,Class B, 115 and 230Vac<br>Radiated emissions CISPR15, EN55032: 2015/CISPR22 Class B, CISPR32 Class B, FCC Part 15.109, Class B at 115 and 230Vac<br>Harmonic current emissions EN61000-3-2, Class A, and C (230Vac, 100% load)<br>Voltage fluctuations & flicker IEC61000-3-3<br>Electro static discharge immunity EN55035:2017, EN55024/IEC61000-4-2, Level 4: +/-8kV contact, +/-15kV air, Criteria A<br>Radiated RF immunity EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz<br>Electrical fast transients / bursts EN55035:2017EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A<br>Surge susceptibility EN55035:2017EN55024/IEC61000-4-5, Level 3, +/-1kV DM, +/-2kV CM, Criteria A<br>EN55022/IEC61000-4-6, 3V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur radio bands<br>Conducted RF susceptibility<br>between 0.15Mhz and 80Mhz, 80% AM at 1KHz<br>Power frequency magnetic fields test EN55035:2017N55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz<br>EN55035:2017EN55024/IEC/EN61000-4-11:<br>--100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees. Criteria A @ full load.<br>Voltage dip immunity<br>--100% dip for 20mS, 0 deg., Criteria A @ full load<br>--100% dip for 5000mS, Criteria B<br>**----- End of picture text -----**<br> Notes: Performance criteria are based on EN55024. According to the standards, performance criteria are decoded as following: - A. Normal performance during and after the test - B. Temporary degradation, self-recoverable - C. Temporary degradation, operator intervention required to recover the operation - D. Permanent damage ## **PIN ASSIGNMENTS** **==> picture [479 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> Type Connector Pin Assignments Mating Connector<br>TE# 640445-3 PIN 1 AC Neutral TE/AMP# 640250-3<br>CN1 Input connector<br>(1 pin removed) PIN 3 AC Line Pins: 640252-1<br>Ground2 - Functional Ground (FG) Mounting Hole Location<br>PIN 1 +Vo<br>PIN 2 +Vo<br>TE# PIN 3 +Vo TE/AMP# 640250-6<br>CN2 Output connector<br>640445-6 PIN 4 RTN Pins: 640252-1<br>PIN 5 RTN<br>PIN 6 RTN<br>**----- End of picture text -----**<br> Notes: 1. Contact AE for other compatible connector options. 2. This power supply requires mounting on standoffs 0.20” (5mm) minimum in height. **4 advancedenergy.com** **SLB350** **==> picture [111 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL DRAWING<br>**----- End of picture text -----**<br> Notes: 1. Recommended assembly screws - It is recommended to use M3 SEMS screws with heads that do not exceed 5.5 pie. 2. Assemble on a metal plate with metal standoffs getting better EMI performance. When installing the power supply into the end-product, a non-conductive insulator should be placed between the unit and any conductive metal chassis or mounting platform. 3. All dimensions in mm. 4. This power supply requires mounting on metal standoffs 0.20" (5 mm) min. in height. 5. Weight: 370 g. **advancedenergy.com 5** **==> picture [596 x 270] intentionally omitted <==** ## **ABOUT ADVANCED ENERGY** Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. ## **TRUST** For international contact information, visit advancedenergy.com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2025 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, and AE® are U.S. trademarks of Advanced Energy Industries, Inc. ENG-SLB350-11.21.25
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →