Image not available
Illustrative purposes only
SLB1000S24K
1000W ENCLOSED FAN COOLED POWER SUPPLY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SL POWER / ADVANCED ENERGY
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 264.11 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **SL POWER SLB1000** 1000 Watt Bulk Front End Advanced Energy’s SL Power SLB1000 provides a low cost solution to Industrial and Medical single output high power requirements. Full featured, the 2.4" x 5.2" x 10.0" enclosed form factor utilizes smart fans for self contained thermal management at very low acoustic noise levels. Voltage output for the series ranges from 12 V to 48V nominal at a continuous output power of 1000 W. ## **AT A GLANCE** ## **Total Power** **1000 W** ## **# of Outputs** **Single** ## **Outputs** **12 to 48 VDC 5 VDC standby** ## **SPECIAL FEATURES** - 1000 W output power - 2.4” x 5.2” x 10.0” - 7.7 Watts per cubic inch - Industrial/Medical safety - -20 °C to 70 °C with derating - High efficiency: 90% typical - Variable speed “Smart Fans” - ± 5% voltage adjustment range - Low acoustic noise - DC OK signal and inhibit function ## **COMPLIANCE** - EMI: CE Class B, RE Class A - EN61000 Immunity, Heavy Industrial ## **SAFETY** > UL/cUL Recognized ITE (UL/CSA62368-1) - UL/cUL Recognized Medical - (ANSI/AAMI ES60601-1 Type BF) - CE LVD (EN62368-1 + ROHS) - CB Report - CE Mark - EMC according to the medical standard IEC 60601-1-2 4th Edition ©2025 Advanced Energy Industries, Inc. **SLB1000** ## **ELECTRICAL SPECIFICATIONS** **==> picture [479 x 257] intentionally omitted <==** **----- Start of picture text -----**<br> Input<br>Input Ra nge 90 to 264 VAC (Operating)<br>115/230 VAC (Nominal)<br>TERMINAL BLOCK<br>Frequency 47 to 63 Hz, Nominal 50/60<br>Input Fusing Internal 15 A fuses, both lines fused<br>Inrush Current 40 A peak, cold start<br>Power Factor 0.99 typical, meets EN61000-3-2<br>Harmonics Meets IEC 1000-3-2 requirements<br>Input Current 12 A RMS max input current, at 100 VAC<br>Hold Up Time 16 mS minimum for Main O/P, at full rated load<br>Efficiency > 90% typical<br>Leakage Current Input-Earth: <500μA @ 264VAC; Input-Output: <100uA @ 264VAC; Output-Ground: <250uA @<br>264VAC<br>Power Line Transient MOV directly after the fuse<br>Isolation PRI-Chassis 2087 VAC Basic<br>PRI-SEC 4000 VAC Reinforced 2xMOPP<br>SEC-Chassis 500 VDC<br>Switching Frequency PFC: Variable, 30kHz to 125kHz; Main Switch: TBD<br>No Load Input Power <30 W, with main output disabled and no load on 5Vsb output<br>**----- End of picture text -----**<br> **==> picture [478 x 236] intentionally omitted <==** **----- Start of picture text -----**<br> Output<br>Output Rating See 'ORDERING INFORMATION' Section 90 to 264 VAC<br>Set Point ± 1.0% 50% Load, 115 VAC, 25°C Ambient<br>Total Regulation Range Main output ± 5% Combined line/load/transient when measured at output terminal<br>Rated Load 1000 W maximum Derate linear to 50% from 50°C to 70°C<br>Minimum Load 0 A<br>Ripple and Noise 1.5% Vout max p-p 20 MHz Bandwidth, differential mode. Measured with noise probe<br>directly across output terminals, and load terminated with 0.1μF<br>ceramic and 47μF low ESR capacitors.<br>Output Voltage Overshoot <10% overshoot at turn-on All conditions<br><1% overshoot at turn-off<br>Transient Response Max. voltage deviation is ±3.5% of final value 50% load step @ 0.2 A/μs, between 25% to 100% of output rating<br>Recovery time < 500 μS for return to within 0.5% of set point<br>Output Voltage Adjustability ±5% (+0%, -5% for 48V model)<br>Short Circuit Protection Protected, no damage to occur Auto-Recovery<br>Remote Sense Compensation up to 250 mV<br>Overload Protection (OCP) 105% to 125% Hiccup Mode; 5Vsb output: 110% to 170%<br>Overvoltage Protection (OVP) 115% to 155%<br>Overtemp Protection Latch Mode, will require AC recycle to reset<br>Capacitive Load 12V: 2000uF, 24V: 10000uF, 48V: 5000uF 5Vsb outout: 5270uF<br>MTBF >250K Hours Telcordia SR-332, Issue 3, 110V/220V, for both 25°C and 50°C<br>**----- End of picture text -----**<br> **2 advancedenergy.com** **SLB1000** ## **ENVIRONMENTAL SPECIFICATIONS** **==> picture [478 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> Operating Temperature -20°C to 70°C (with linear 50% derating from 40°C to 70°C)<br>Storage Temperature -40°C to +85°C<br>Humidity 5% to 95%, non-condensing<br>Fan Noise <TBD dBA, 100% load at 30°C, Tested per ISO7999<br>Altitude Operating: -500m to 5000m<br>Storage: -500m to 12,192m<br>Shock Per IEC60068-2-6<br>Vibration Per IEC60068-2-27<br>**----- End of picture text -----**<br> ## **EMI/EMC COMPLIANCE** **==> picture [479 x 220] intentionally omitted <==** **----- Start of picture text -----**<br> Conducted Emissions EN55011/32: Class B, CISPR11/32: Class B, FCC Part 15.107, Class B; 3dB margin typ, at 120 and 230VAC.<br>Radiated Emissions EN55011/32: Class A, CISPR11/32: Class A, FCC Part 15.107, Class A, 3dB margin typ, at 120 and 230VAC2<br>Harmonic Current Emissions EN61000-3-2, Class A (230VAC, 100% load)<br>Voltage Fluctuations & Flicker IEC61000-3-3<br>Electro Static Discharge Immunity EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A, IEC60601-1-2, 4th Edition, Table 4<br>Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz, IEC60601-1-2, 4th Edition, Table 4<br>Electrical Fast Transients/Bursts EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A, IEC60601-1-2, 4th Edition, Table 5<br>Surges Line to Line (DM) and Line to EN55024/IEC61000-4-5, Level 3, +/-1kV DM, +/-2kV CM, Criteria A; Level 4, +/-2kV DM, +/-4kV CM, Criteria C;<br>Ground (CM) Surpasses IEC60601-1-2, 4th Ed.requirements.<br>Conducted Disturbances Induced EN55022/IEC61000-4-6, 3V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur radio bands<br>by RF Fields between 0.15Mhz and 80Mhz, 80% AM at 1KHz, IEC60601-1-2, 4th Edition, Table 5.<br>Rated Power Frequency Magnetic<br>EN55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz, IEC60601-1-2, 4th Edition, Table 4<br>Fields Test<br>EN55024/IEC/EN61000-4-11:<br>--100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees:<br>Voltage Dips --100% dip for 20mS, 0 deg., Criteria B, TBDW load for Criteria A<br>--100% dip for 5000mS (250/300 cycles), Criteria B<br>-- 60% dip for 100mS, Criteria B<br>**----- End of picture text -----**<br> Notes: 1. Performance criteria are based on EN55024. According to the standards, performance criteria are decoded as following: - A. Normal performance during and after the test - B. Temporary degradation, self-recoverable - C. Temporary degradation, operator intervention required to recover the operation - D. Permanent damage 2. With external ferrite core on the output cable for the 48V model. ## **ORDERING INFORMATION** **==> picture [478 x 67] intentionally omitted <==** **----- Start of picture text -----**<br> Vin = 100 to 264 VAC Vin < 100 VAC<br>Model Number Output Voltage<br>Output Current Output Power Output Current Output Power<br>SLB1000S12K 12 V 84.0 A 1000 W 66.6 A 800 W<br>SLB1000S24K 24 V 42.0 A 1000 W 33.3 A 800 W<br>SLB1000S48K 48 V 21.0 A 1000 W 16.6 A 800 W<br>**----- End of picture text -----**<br> **advancedenergy.com 3** **SLB1000** ## **PIN ASSIGNMENT** **==> picture [479 x 301] intentionally omitted <==** **----- Start of picture text -----**<br> Input Voltage Pin Description Connector Information<br>L AC LINE Terminal Block with (3) M4 Screws<br>N AC NEUTRAL Torque = 16kgf-cm<br>G GROUND 13mm centers<br>Output Voltage Pin Description Connector Information<br>+Vout SK3, Power rail Mating part: Molex 19141-0058 or equivalent<br>GND SK4, Power GND Mating part: Molex 19141-0058 or equivalent<br>Output Control Signals Description SK2 Pin Number<br>5Vsb 5V @ 2A Standby Output 1<br>-VS Remote Sense Return 2<br>5Vsb 5V @ 2A Standby Output 3<br>GND Signal Return 4<br>G_DCOK_E DC OK Signal 5<br>-VPROG Programming Signal Return 6<br>G_DCOK_C DC OK Signal 7<br>NC No Connection 8<br>+VPROG Programming Signal 9<br>+Vsense Remote Sense Positive 10<br>SCL TBD 11<br>INH_EN Inhibit Signal 12<br>SDA TBD 13<br>GND Signal Return 14<br>**----- End of picture text -----**<br> Note: Mating connector for SK2 is: LANDWIN: PN 2050S2000 Housing and PN 2053T021V Contact CIVILUX: PN CI0120SD000 Housing and PN CI01TD21PE0 Contact **4 advancedenergy.com** **SLB1000** **==> picture [119 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL DRAWINGS<br>**----- End of picture text -----**<br> **advancedenergy.com 5** **==> picture [596 x 270] intentionally omitted <==** ## **ABOUT ADVANCED ENERGY** Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. **TRUST** For international contact information, visit advancedenergy.com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2025 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc. ENG-SLB1000- 11.17.2025
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →