Image not available
Illustrative purposes only
SKL20220
Solid State Relay, 25 A, 280 Vrms, PCB, Through Hole, Zero Crossing
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CELDUC
- Product type:
- Contact Configuration:-; Load Current:25A; Operating Voltage Max:280Vrms; Relay Mounting:PCB; Relay Terminals:Through Hole; Switching Mode:Zero Crossing; Operating Voltage Min:12Vrms; Co
- SVHC: No SVHC (27-Jun-2024)
- Load Current: 25A
- Product Range: SKL Series
- Relay Mounting: PCB
- Switching Mode: Zero Crossing
- Relay Terminals: Through Hole
- Control Voltage Max: 32VDC
- Control Voltage Min: 8VDC
- Contact Configuration: -
- Operating Voltage Max: 280Vrms
- Operating Voltage Min: 12Vrms
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 26.54 € |
| Current stock | 50+ |
| Lead time | 30 days |
~~S/MOD/SKL20220/B/23/03/2000~~ page 1 / 3 F/GB ## **Relais Statique pour circuit imprimé** _**Solid State Relay for printed circuit board**_ ## **• Gamme pour circuit imprimé pour montage** ## **SKL20220** ## **8-32VDC control 25A*/ 230VAC output** ## **sur dissipateur thermique.** - **Sortie AC synchrone.** - **Calibre élément de puissance : 25A** - **Technologie DCB ( Direct Copper Bonding)** - _**Range for printed circuit board for mounting**_ ## _**on an external heatsink.**_ ## **•** _**Zero-cross AC Output.**_ ## **•** _**Power element size : 25A.**_ *** :** Limité par le radiateur : 20A@25°C avec WF032000 / _limited by the heatsink : 20A@25°C with WF032000_ ## **•** _**DCB technology ( Direct Copper Bonding)**_ Ces produits sont disponibles avec d'autres tailles de thyristors : 16A , 50A/1800A2s et 75A/5000A2s pour de très hautes performances. T _hese products are available with other sizes thyristors: 16A ,50A/1800A2s and 75A / 5000A2s for high performances._ Application typique/ _Typical application_ **Caractéristiques de commande (à 20°C)** _**/ Control characteristics (at 20°C)**_ |**Paramètres /****_Parameters_**<br>Tension de commande /_Control voltage_<br>Courant de commande /_Control current(@ Uc nom)_<br>Tension de relachement/_Release voltage_|**Symbol**<br>Uc<br>Ic<br>Uc off|**Min**<br>8<br>3,5|**DC**<br>**Nom**<br>24<br>13,5||**Max**<br>32<br>18<br>1|**Unit**<br>V<br>mA<br>V| |---|---|---|---|---|---|---| |Résistance interne /_Input internal resistor_fig.1<br>Rc<br>1640<br>**Caractéristiques d'entrée-sortie(à 20°C) ****_/ Input-output characteristics(at 20°C)_**||||||Ω| |Tension assignée Isolement/Rated impulse voltage<br>Isolement entrée-sortie /_Input-output isolation_|Uimp<br>U|4000|4 000|||V<br>VRMS| |Isolement E-S/semelle/ I-O/ case insulation|U|3300||||VRMS| **Caractéristiques générales /** _**General characteristics**_ |**Paramètres /****_Parameters_**|**Conditions**|**Symbol**|**Typ.**|**Unit**| |---|---|---|---|---| |Poids/_Weight_|||15|g| |Température de stockage /_Storage temperature_|||-40/+120|°C| |Température de fonctionnement /_Operating temperature_|||-40/+80|°C| ## _**Proud to serve you**_ **celduc[®] r e l a i s** All technical caracteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis. ~~S/MOD/SKL20220/B/23/03/2000~~ page 2 / 3 F/GB **Caractéristiques de sortie(à 20°C)** _**/ Output characteristics (at 20°C)**_ |**Paramètres /****_Parameters_**|**Conditions**|**Symbol**|**Typ.**|**Unit**| |---|---|---|---|---| |Tension de charge /_Load voltage_||Ue|230|V rms| |Plage tension de fonctionnement /_Operating range_||Uemin-max|12-280|V rms| |Tension crête /_Peak voltage_||Up|600|V| |Niveau de synchonisation /_Synchronizing level_||Usync|12|V| |Tension d'amorçage /_Latching voltage_|Ie nom|Ua|8|V| |Courant nominal /_Nominal current_||Ie|25(*)|A rms| |Courant de surcharge non répétitif /_Non repetitive overload current_|tp=10ms_(Fig. 3)_|Itsm|250|A| |Chute tension directe crête/_On state voltage drop_|@ Ie nom|Vd|1,6|V| |Courant de fuite état bloqué/_Off state leakage current_|@Ue,50Hz|Ilk|1|mA| |Courant de charge minimum /_Minimum load current_||Iemin|5|mA| |Temps de fermeture/_Turn on time_|Uc nom DC,f=50Hz|ton max|10|ms| |Temps d'ouverture/_Turn off time_|Uc nom DC,f=50Hz|toff max|10|ms| |Plage de fréquence /_Operating frequency range_||f|10-440|Hz| |dv/dt état bloqué /_Off state dv/dt_||dv/dt|500|V/µs| |dI/dt maximum non répétitif/_Maximum di/dt non repetitive_||di/dt|50|A/µs| |I2t(<10ms)||I2t|312|A2s| |EMC Test d'immunité /_Conducted immunity level: with external VDR_|IEC 1000-4-4(bursts)|2kV criterion A with external VDR||| |EMC Test d'immunité /_Conducted immunity level : with external VDR_|IEC 1000-4-5(shocks)|2kV criterion A with external VDR||| |Conformité /_Conformity_|EN60947-4-x and 5-1 /pr EN61810-xxx|||| |Homologation / Approval|UL File E69913|||| - Limité par le radiateur : se reporter aux courbes ci-dessous - _Limited by the heatsink : see curves fig 2_ **Fig.2 Caractéristiques thermiques /** _**thermal curves :**_ Utilisation des courbes / _Use curves :_ **==> picture [244 x 281] intentionally omitted <==** **----- Start of picture text -----**<br> Par calcul / calculation method<br>Puissance Dissipée<br>par relais pour un courant permanent : 35<br> SSR Power Dissipation for a<br>permanent current: ”ot<br>2<br>Pd= (0,8xI +0,016 x I )<br>-<br>Pour un cycle de marche plus faible CF 3 5<br>( cycle <30s) /<br>For a lower duty cycle ( cycle <30s)<br>Pd= Pd x ton/ ( ton+toff) zg,<br>Résistance thermique jonction /radiateur / — Poe<br>=<br>Thermal resistor between junction/heatsink :<br>Rthj/c = 1,3K/W PoC<br>,<br>Choix dissipateur simplifié / 6<br>Easy choice of heatsink :<br>- - 0<br>Rth heatsink= ((125 Tamb) /Pd) 1,3<br>Précautions :<br>* Les relais à semiconducteurs ne procurent pas d'isolation<br>galvanique entre le réseau et la charge.<br>* Prévoir un varistor externe en parallèle sur la sortie : taille<br>mini : 14mm<br>**----- End of picture text -----**<br> ## _Cautions_ : - _Semiconductor relays don't provide any galvanic insulation between the load and the mains._ - _Use a VDR across the output : minimum size : 14 mm_ **celduc ® r e l a i s** ~~**www.celduc.com**~~ **5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19** ~~S/MOD/SKL20220/B/23/03/2000~~ page 3 / 3 F/GB ## Montage sur carte _/ PCB mouting_ - 1) Ces relais se sont pas compatibles avec une techno de « reflow » : _not suitable for reflow process_ 2) Dans un process vague, limites : température max de 260°C durant 10 secondes : _Wave solder : max 260°C 10 secondes IPC/JEDEC J-STD-020C_ - 3) Dans un process soudure manuel : max 400°C durant 5 secondes sur les terminaux : _hand solder max 400°C 5s_ **==> picture [94 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> celduc ®<br>**----- End of picture text -----**<br> ~~**www.celduc.com**~~ **r e l a i s 5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →