SKA20460
Solid State Relay, 4 A, 600 Vrms, PCB, Through Hole, Zero Crossing
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CELDUC
- Product type:
- Contact Configuration:-; Load Current:4A; Operating Voltage Max:600Vrms; Relay Mounting:PCB; Relay Terminals:Through Hole; Switching Mode:Zero Crossing; Operating Voltage Min:24Vrms; Control Voltage Min:5
- SVHC: No SVHC (27-Jun-2024)
- Load Current: 4A
- Product Range: SKA Series
- Relay Mounting: PCB
- Switching Mode: Zero Crossing
- Relay Terminals: Through Hole
- Control Voltage Max: 30VDC
- Control Voltage Min: 5VDC
- Contact Configuration: -
- Operating Voltage Max: 600Vrms
- Operating Voltage Min: 24Vrms
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 26.11 € |
| Current stock | 25+ |
| Lead time | 30 days |
~~S/MOD/SKA20460/B/07/06/2013~~ page 1 / 4F/GB ## **Relais statique pour circuit imprimé AC Solid State Relay for PCB mounting** ## **SKA20460** - → Relais statique synchrone pour circuit imprimé spécialement adapté à la plupart des charges. Zero Cross Solid State Relay for printed circuit board designed for most types of loads. **Output : 24-600VAC 5A Input : 5-30VDC** - → Tension de sortie élevée : 600VAC avec des composants 1200V. Haute immunité aux perturbations selon IEC/EN61000-4-4 & IEC/EN61000-4-5. High output voltage : 600VRMS with 1200Vpeak components High immunity according IEC/EN61000-4-4 & IEC/EN61000-4-5 - → Très faible niveau de synchronisme / Very low zero cross voltage. - → Très faible courant de fuite / Very low leakage current. - → Fort courant de surcharge avec un calibre de courant non permanent de 10A / High surge current with a nominal power component of 10A (non permanent) → Construit en conformité aux normes IEC/EN60947-4-3 et EN60950/VDE0805 ; IEC 60335-1/ VDE0700-1 ; Designed in conformity with IEC/ EN60947-4-3 and EN60950/VDE0805 ; IEC 60335-1/ VDE0700-1 ; **==> picture [46 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions<br>**----- End of picture text -----**<br> **CAD documents: www.celduc-relais.com/uk/plan3d.asp** ## _**Proud to serve you**_ **celduc[®] r e l a i s** All technical caracteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis. ~~S/MOD/SKA20460/B/07/06/2013~~ page 2 / 4F/GB |||DC|DC|DC|| |---|---|---|---|---|---| |Paramètre /Parameter|Symbol|Min|Typ|Max|Unit| |Tension de commande /Control voltage|Uc|5|5-12-24|30|V| |Courant de commande /Control current(@Uc)|Ic|3||29|mA| |Tension de non fonctionnement /Release voltage|Uc off|0.8|||V| |Résistance interne / Input internal resistance|Rc|1000|||Ω| |Immunité /Input immunity : EN61000-4-4||2kV|||| |Immunité/Input immunity : EN61000-4-5||2KV|||| Input : Ic = f( Uc) ## **Caractéristiques de sortie / Output characteristics (at 25°C)** |Paramètre/ Parameter<br>~~a~~<br>~~a~~|Conditions<br>~~QO~~<br>~~QO~~|Symbol<br>~~QO~~<br>~~QO~~|Min<br>~~GO~~<br>~~QO~~|Typ.<br>~~QO~~|Max|Unit| |---|---|---|---|---|---|---| |Plage de tension utilisation /Operatingvoltage range<br>~~a~~<br>~~a~~<br>~~a~~|~~QO~~<br>~~QO~~<br>~~QO~~|Ue<br>~~QO~~<br>~~QO~~<br>~~QO~~|24<br>~~GO~~<br>~~QO~~<br>~~OO~~|400-480<br>~~QO~~<br>~~OO~~|600|V rms| |Tension de crête /Peak voltage(clampingvoltage)<br>~~a~~<br>~~a~~<br>~~a~~|Up<br>~~QO~~<br>~~QO~~<br>~~QO~~|~~QO~~<br>~~QO~~<br>~~QO~~|1200<br>~~QO~~<br>~~OO~~<br>~~OO~~|||V| |Niveau de synchronisme /Zero cross level<br>~~a~~<br>~~a~~<br>~~**a**~~|~~QO~~<br>~~QO~~<br>~~QO~~|Usync<br>~~QO~~<br>~~QO~~<br>~~QO~~|~~OO~~<br>~~OO~~<br>~~QO~~|~~OO~~<br>~~OO~~|12|V| |Tension minimum amorçage/ Latchingvoltage<br>~~a~~<br>~~**a**~~<br>~~a~~|Ie nom<br>~~QO~~<br>~~QO~~<br>~~QO~~|Ua<br>~~QO~~<br>~~QO~~<br>~~QO~~|10<br>~~OO~~<br>~~QO~~<br>~~QO~~|~~OO~~<br>~~QO~~||V| |Courant nominal /nominal current (AC-51)<br>~~**a**~~<br>~~a~~<br>~~a~~|Heater<br>~~QO~~<br>~~QO~~<br>~~QO~~|Ie AC-51<br>~~QO~~<br>~~QO~~<br>~~QO~~|~~QO~~<br>~~QO~~<br>~~QO~~|4<br>~~QO~~<br>~~QO~~|5|A rms| |Courant nominal /nominal current (AC-53)<br>~~a~~<br>~~a~~|Motor<br>~~QO~~<br>~~QO~~<br>~~QO~~|Ie AC-53<br>~~QO~~<br>~~QO~~<br>~~QO~~|~~QO~~<br>~~QO~~<br>~~CO~~|1.5<br>~~QO~~<br>~~QO~~<br>~~CO~~||A rms| |Courant nominal /nominal current (other loads)<br>~~a~~|Other loads<br>~~QO~~<br>~~QO~~<br>~~QO~~|Ie<br>~~QO~~<br>~~QO~~<br>~~QO~~|Seepage 3<br>~~QO~~<br>~~CO~~<br>~~QO~~|||| |Courant surcharge/ Non repetitive overload current<br>~~a~~|tp=10ms(Fig. 3)<br>~~QO~~<br>~~a~~<br>~~QO~~<br>~~QO~~|Itsm<br>~~QO~~<br>~~a~~<br>~~QO~~<br>~~QO~~|105<br>~~CO~~<br>~~a~~<br>~~QO~~<br>~~QO~~|120<br>~~CO~~<br>~~a~~<br>~~QO~~|~~a~~|A<br>~~a~~| |Chute directe à l'étatpassant /On state voltage drop<br>~~a~~|(Ie = nominal current)<br>~~QO~~<br>~~a~~<br>~~QO~~|V<br>~~QO~~<br>~~a~~<br>~~QO~~|0.85 + 0,040xIe<br>~~QO~~<br>~~a~~<br>~~QO~~<br>~~I~~|||V<br>~~a~~| |Tension seuil à l'état passant /On state Threshold voltage<br>~~(OD~~|Threshold voltage<br>@ 25°C<br>~~QO~~<br>~~(OD~~|Vto<br>~~QO~~<br>~~(OD~~|~~QO~~<br>~~(OD~~|~~QO~~<br>~~(OD~~<br>~~I~~|0.85<br>~~(OD~~|V<br>~~(OD~~| |Résistance dynamique /On state dynamic resistance<br>~~QO~~|~~QO~~|rt<br>~~QO~~|~~QO~~|~~I~~<br>~~QO~~|40<br>~~QO~~|mΩ<br>~~QO~~| |Puissance dissipée (max) /<br>Outputpower dissipation(max value)||Pd|0,765xIe + 0,040xIe2|||W| |Résistance thermique jonction/air<br>Thermal resistance betweenjunction to air<br>~~**a**~~|( depending on installation)<br>~~GO~~|Rthj/a<br>~~GO~~|21<br>~~GO~~|24<br>~~GO~~|33|K/W| |Courant de fuite à l'état bloqué/ Off state leakage current<br>~~**a**~~<br>~~a~~|@Ue typ,50Hz<br>~~GO~~<br>~~QO~~|Ilk<br>~~GO~~<br>~~QO~~|~~GO~~<br>~~QO~~|~~GO~~|0.1|mA| |Courant minimum de charge/ Minimum load current<br>~~**a**~~<br>~~a~~<br>~~a~~|~~GO~~<br>~~QO~~<br>~~QO~~|Iemin<br>~~GO~~<br>~~QO~~<br>~~QO~~|1<br>~~GO~~<br>~~QO~~<br>~~QO~~|~~GO~~<br>~~QO~~||mA| |Temps de fermeture/ Turn on time<br>~~a~~<br>~~a~~<br>~~a~~|@Ue typ,50Hz<br>~~QO~~<br>~~QO~~<br>~~QO~~|ton max<br>~~QO~~<br>~~QO~~<br>~~QO~~|~~QO~~<br>~~QO~~<br>~~QO~~|~~QO~~<br>~~QO~~|10|ms| |Temps d'ouverture /Turn off time<br>~~a~~<br>~~a~~<br>~~a~~|@Ue typ,50Hz<br>~~QO~~<br>~~QO~~<br>~~GO~~|toff max<br>~~QO~~<br>~~QO~~<br>~~GO~~|~~QO~~<br>~~QO~~<br>~~OO~~|~~QO~~<br>~~QO~~<br>~~OO~~|10|ms| |Fréquence réseau/ Mains frequencyrange<br>~~a~~<br>~~a~~<br>~~a~~|F mains<br>~~QO~~<br>~~GO~~<br>~~QQ~~|f<br>~~QO~~<br>~~GO~~<br>~~QQ~~|0,1<br>~~QO~~<br>~~OO~~<br>~~QQ~~|50-60<br>~~QO~~<br>~~OO~~|800|Hz| |dv/dt à l'état bloqué /Off state dv/dt<br>~~a~~<br>~~a~~|~~GO~~<br>~~QQ~~<br>~~QO~~|dv/dt<br>~~GO~~<br>~~QQ~~<br>~~QO~~|500<br>~~OO~~<br>~~QQ~~<br>~~QO~~|~~OO~~<br>~~QO~~||V/µs| |di/dt max /Maximum di/dt non repetitive<br>~~a~~<br>~~a~~|~~QQ~~<br>~~QO~~<br>~~QO~~|di/dt<br>~~QQ~~<br>~~QO~~<br>~~QO~~|~~QQ~~<br>~~QO~~<br>~~QO~~|~~QO~~<br>~~QO~~|50|A/µs| |I2t(<10ms) : Value for fusing<br>~~ee~~<br>~~a~~|~~QO~~<br>~~ee~~<br>~~QO~~<br>~~GO~~|I2t<br>~~QO~~<br>~~ee~~<br>~~QO~~<br>~~GO~~|55<br>~~QO~~<br>~~ee~~<br>~~QO~~<br>~~OO~~|72<br>~~QO~~<br>~~ee~~<br>~~QO~~<br>~~OO~~|~~ee~~|A2s<br>~~ee~~| |Immunité /Conducted immunitylevel<br>~~a~~|IEC/EN61000-4-4(bursts)<br>~~QO~~<br>~~GO~~|~~QO~~<br>~~GO~~|2kV criterion A (with external VDR)<br>~~QO~~<br>~~OO~~|||| |Immunité /Conducted immunitylevel<br>~~ff~~|IEC/EN61000-4-5(surge)<br>~~GO~~<br>~~ff~~|~~GO~~<br>~~ff~~|2kV criterion A (with external VDR)<br>~~OO~~<br>~~ff~~|||~~ff~~| |||||||| **® celduc r e l a i s** ~~**www.celduc.com**~~ **5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19** ~~S/MOD/SKA20460/B/07/06/2013~~ page 3 / 4F/GB ## **Fig. 2 Courbes thermiques / Thermal curves** ## **fig 3 : Courants de surcharges / Overload currents** - 1 - Itsm non répétitif sans tension réappliquée est donné pour la détermination des protections. 1 - No repetitive Itsm is given without voltage reapplied . This curve is used to define the protection (fuses). - 2 -Itsm répétitif est donné pour des surcharges de courant Attention : la répétition de ces surcharges de courant diminue la durée de vie du relais. 2 - Repetitive Itsm is given for inrush current. In normal operation, this curve musn't be exceeded. Caution, frequent over load currents will decrease the life expectancy of the SSR. - → Attention ! les relais à semi-conducteurs ne procurent pas d'isolation galvanique entre le réseau et la charge. Ils doivent être utilisés associés à un disjoncteur avec propriété de sectionnement ou similaire, afin d'assurer un sectionnement fiable en amont de la ligne dans l'hypothèse d'une défaillance et pour tous les cas où le relais doit être isolé du réseau (maintenance; non utilisation sur une longue durée...). Sous réserve d'installation, d'entretien et d'utilisation conformes à sa destination, à la réglementation, aux normes en vigueur, aux instructions du constructeur et aux règles de l'art. → Warning ! semiconductor relays don't provide any galvanic insulation between the load and the mains. Always use in conjunction with an adapted circuit breaker with insulation feature or a similar device in order to ensure a reliable insulation in the event of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...). It is important that the solid state relay is subject to correct installation, maintenance and use conforming to its intended regulations and standards, to the supplier's instructions and to accepted rules of art. **® celduc** ~~**www.celduc.com**~~ **r e l a i s** **5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19** ~~S/MOD/SKA20460/B/07/06/2013~~ page 4 / 4F/GB ## **Applications typiques / Typical LOADS** - > Les produits SKA sont adaptés au contrôle de la plupart des charges. Nous donnons dans nos spécifications le courant en AC-51 (charge résistive). Pour les autres charges, il faut surveiller les surcharges en courant à la fermeture et les surtensions éventuelles à l'ouverture. - AC-55b: Lampes à incandescence : Courants d'appel généralement de 10 fois le courant nominal durant quelques 10ms . - AC-55a: Lampes à décharge. Ces charges ont souvent des surcourants importants à la fermeture et des surtensions à l'ouverture (capacités). Nous conseillons d'utiliser des relais 400VAC sur réseau 230VAC. - AC-58: Moteurs monophasés . Ces charges ont souvent des surcourants importants à la fermeture et des surtensions à l'ouverture (capacités). Nous conseillons d'utiliser des relais 400VAC sur réseau 230VAC et d'adapter le courant du relais au courant de démarrage. - > SKA products are designed for most types of loads. We give in our data-sheet the AC-51 current value corresponding to resistive loads. For other loads, check the inrush current at turn ON and possible overvoltages at turn OFF: - AC-55b: Incandescent lamps : Inrush current is generally 10 times In during few 10ms. - AC-55a: Electric discharge lamp : These loads often have overcurrent at turn ON and overvoltage at turn OFF, so we advise to use 400VAC SSR on 230VAC mains. - AC-58: One pole motors. These loads often have overcurrent at turn ON and overvoltage at turn OFF, so we advise to use 400VAC SSR on 230VAC mains and to adapt the SSR current to the starting current of the motor. ## **Protection / Protection :** - > La protection d'un relais statique contre les court-circuits de la charge peut être faite par fusibles rapides avec des I[2] t = 1/2 I[2] t du relais . - Pour plus de détails nous consulter - > To protect a SSR against a short-circuit of the load , use a fuse with a I[2] t value = 1/2 I[2] t value specified page 2. - For more details consult us. ## **CEM / EMC :** − > Immunité : Nous spécifions dans nos notices le niveau d'immunité de nos produits selon les normes essentielles pour ce type de produit, c'est à dire IEC/ EN61000-4-4 & IEC/ EN61000-4-5. Mais nous respectons aussi les autres normes CEM IEC/ EN61000-4-2 ; IEC/ EN61000-4-6; .... en conformité avec la norme IEC60947-4-3 - > Immunity: We give in our data-sheets immunity level according to the main standards for these products: IEC/EN61000-4-4 & - IEC/EN61000-4-5. But we are also in conformity with other standards IEC/EN61000-4-2, IEC/EN61000-4-6, .... in compliance with IEC/EN60947-4-3. - > Emission: Nos relais statiques sont principalement conçus et conformes pour la classe d'appareils A (Industrie). - L'utilisation du produit dans des environnements domestiques peut amener l'utilisateur à employer des moyens d'atténuation supplémentaires. En effet, les relais statiques sont des dispositifs complexes qui doivent être interconnectés avec d'autres materiels (charges, cables, etc) pour former un système. Etant donné que les autres materiels ou interconnexions ne sont pas de la responsabilité de **celduc[®]** , il est de la responsabilité du réalisateur du système de s'assurer que les systèmes contenant des relais statiques satisfont aux prescriptions de toutes les règles et règlements applicables au niveau des systèmes. Consulter **celduc[®]** qui peut vous conseiller ou réaliser des essais dans son laboratoire sur votre application. - > Emission: **celduc[®]** SSRs are mainly designed in compliance with standards for class A equipment (Industry). - Use of this product in domestic environments may cause radio interference. In this case the user may be required to employ additionnal devices to reduce noise. SSRs are complex devices that must be interconnected with other equipment (loads, cables, etc.) to form a system. Because the other equipment or the interconnections may not be under the control of **celduc[®]** , it shall be the responsability of the system integrator to ensure that systems containing SSRs comply with the requirement of any rules and regulations applicable at the system level. Consult **celduc[®]** for advices. Tests can be performed in our laboratory. ## **® celduc** ~~**www.celduc.com**~~ **r e l a i s** **5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →