Image not available
Illustrative purposes only
SIL465400
Solid State Relay, 4-20mA, IP20, 32 A, 450 VAC, DIN Rail, Screw, Analogue
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CELDUC
- Product type:
- SVHC: No SVHC (14-Jun-2023)
- Load Current: 32A
- Product Range: celpac SIL4 Series
- Relay Mounting: DIN Rail
- Switching Mode: Analogue
- Relay Terminals: Screw
- Control Voltage Max: -
- Control Voltage Min: -
- Contact Configuration: -
- Operating Voltage Max: 450VAC
- Operating Voltage Min: 160VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 237.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
S/SIL465400/A/12/01/2022/GB page 1 / 5 ## **celpac[®]** **Power Solid State Relay With Analog Control, pitch 22.5mm compact size and DIN rail mounting.** - `❏` Ready to use Single-Phase Relay: Phase angle controller Transfer characterisic :Linear angle open loop Operating voltage :160 to 450V Operating Current :0.1 to 32A ## **SIL465400** **Phase angle controller Output : 160-450VAC 32A(*) Input : Analog 4 .. 20mA** - `❏` Wide variety of applications. - `❏` Main frequency range : 40 to 70 Hz with self adaptation - `❏` Analog control : Current 4 .. 20mA - `❏` Green LED visualization on the input - `❏` Relay without trimmer (factory setting) - `❏` Isolated internal power supply (taken from the mains) - `❏` Built in protection : RC and VDR - `❏` Mounting and dismounting on DIN rail without any tool or directly mountable on panel with screws. - `❏` Designed in conformity with EN60947-4-3 - (IEC947-4-3) and EN60950 ## **Dimensions :** - (*) see conditions, thermal curve page 4. ( 22A @ 40°C according IEC 947.4.3 ) ## **Typical application:** **==> picture [34 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> Mains<br>160-450V<br>**----- End of picture text -----**<br> _**Proud to serve you**_ ~~a~~ YT All technical caracteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis. **[celduc] r e l a i s[®]** S/SIL465400/A/12/01/2022/GB page 2 / 5 ## **celpac** ~~**[®]**~~ ## _**Control characteristics (at 25°C)**_ |**Paramètre / Parameter**<br>**Conditions**<br>**Symbol**<br>**Typ.**|**Unit**| |---|---| |Operatingcontrol current<br>Ic<br>4 to 20|mA| |Maximum input voltage<br>Uc max<br>± 14V|V| |Input resistor<br>Rc<br>312|Ω| |Input LED<br>green|| |Rise and fall time<br>See fig. 2<br>time<br>62|ms| |Input immunity<br>IEC 1000-4-4(burst)<br>2kV|| |**_Output characteristics(at 25°C)_**|| |**_Parameter_**<br>Load voltage<br>**Conditions**<br>**Symbol**<br>Ue typ<br>**Typ.**<br>400<br>**Unit**<br>V rms<br>Operatingrange<br>Peak voltage<br>Mains frequencyrange<br>Clampingvoltage<br>Ue min-max<br>Up<br>fm<br>Uclamp<br>160-450<br>1200<br>V rms<br>V<br>40-70<br>820(@1mA)<br>Hz<br>V<br>internalpower supplycurrent counsomption(from mains)<br>AC-51 nominal current :permanent<br>AC-53 nominal current<br>Non repetitive overload current<br>@Ue typ,50Hz<br>**_( see Fig. 4page 4)_**<br>Ie<br>Ie AC-51<br>tp=10ms_(Fig. 3)_<br>Ie AC-53<br>Itsm<br>On state voltage drop (typical value)<br>Dynamic resistance(typical value)<br>@25°C<br>Vt<br>rt<br>6<br>**32**<br>mA rms<br>A rms<br>12<br>550<br>A rms<br>A<br>0,9<br>8<br>V<br>mΩ<br>~~a~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~|| |Output Power dissipation (typical value for full conduction)<br>Thermal resistance betweenjunction to air<br>Pd<br>Rthj/a<br>0,81xIe+0,08xIe2<br>3,3(2,5)<br>W<br>K/W<br>Off state leakage current<br>Minimum load current<br>Rise and fall time<br>Delaytime<br>@Ue,50Hz<br>Ilk<br>Iemin<br>@50Hz see fig. 2<br>@50Hz see fig. 2<br>tau<br>td max<br>Power upinitialisation time<br>Off state dv/dt<br>Maximum non repetitive di/dt<br>I2t(<10ms)<br>@Ue,50Hz<br>t init.<br>dv/dt<br>di/dt<br>I2t<br><5<br>100<br>mA<br>mA<br>15<br>20<br>ms<br>ms<br>160<br>500<br>ms<br>V/µs<br>50<br>1500<br>A/µs<br>A2s<br>Conducted immunitylevel<br>Conducted immunitylevel<br>Short circuitprotection<br>IEC 1000-4-4(burst)<br>IEC 1000-4-5(schocks)<br>FERRAZ<br>4kV criterion B<br>4kV criterion B<br>gRC 25A/32A/50A/63A 14x51<br>~~a~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~GQ~~<br>~~(OO~~<br>~~a~~<br>~~**G**C~~<br>~~a~~<br>~~Q~~|| |**_General characteristics(at 25°C)_**|| |Input to output insulation voltage<br>Ui<br>4000<br>VRMS<br>~~a~~|| |Output to case insulation voltage<br>Ui<br>4000<br>VRMS<br>~~a~~|| |Insulation resistance<br>Ri<br>100(@500VDC)<br>MΩ<br>~~GQ~~|| |Rated impulse voltage<br>Uimp<br>4000<br>V<br>~~a~~|| |Protection level / IEC 529<br>-<br>IP20<br>~~a~~|| |Pollution degree<br>-<br>2<br>~~a~~|| |Vibration resistance 10 -55 Hz accordingto CEI68 :<br>double amplitude<br>(not tested)<br>~~a~~|| |Shocks resistance accordingto CEI68(on DIN rail / with screws)<br>-<br>30/50<br>g<br>~~a~~|| |Ambient temperature(with no icingor condensation)<br>-<br>-20 /+70<br>°C<br>~~GQ~~|| |Storage temperature(with no icingor condensation)<br>-40/+100<br>°C<br>~~a~~|| |Ambient humidity<br>HR<br>40 to 85<br>%<br>~~a~~|| |Weight<br>270<br>g<br>~~a~~|| |Conformity<br>EN60947-4-3 (IEC60947-4-3)<br>~~a~~|| **celduc** ® ~~**www.celduc.com**~~ **r e l a i s 5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19** ~~S/SIL465400/A/12/01/2022/GB~~ page 3 / 5 ## **celpac** ~~**[®]**~~ _**Transfer characteristics (at 25°C)**_ ~~QO~~ **Paramètre /** _**Parameter**_ **Conditions Symbol Min Nom Max Unit** ~~QO~~ Operating analog current Ic 4 .. 20 mA ~~QO~~ Minimum release current 4 mA ~~QO~~ Uload/Ue RMS (@ Ue typ.) @ Ic=20mA >98 % ~~QO~~ Transfer type ~~(~~ linear angle (see Fig. 1 ) ~~QO~~ Tranfer accuracy 2 % ~~QO~~ Minimum step level (Minimum ON angle, Fig. 1) @ Ic=4,3mA tcmin/ta 4 % ~~QO~~ Rise and fall time @50Hz see fig. 2 tau 15 ms ~~QO~~ Delay time @50Hz see fig. 2 td max 20 ms **==> picture [154 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Fig. 2 : Timing (Switch ON) @50Hz<br>**----- End of picture text -----**<br> ## **Other possibilities with SIL4 series :(consult us)** - With trimmer for minimum step level setting: - With trimmer for fall and rise time setting: - Type of soft fall and rise time :linear or exponential - Linear transfer characteristic: angle, RMS, power - Analog input :0 - 5V, 0 - 10V, ... - Mains frequency range - Mains voltage range **==> picture [145 x 380] intentionally omitted <==** **----- Start of picture text -----**<br> Fig.1 Transfer characteric :<br>a<br>; PLT | |<br>L<br>Resist ive load<br>Y,<br>TALE<br>-<br>4 6 8 10 12 14 16<br>Ic(mA)<br>7<br>Aen<br>/ |<br>Yo<br>Min. st ep level(4% )<br>**----- End of picture text -----**<br> - Operating current **celduc** ® ~~**www.celduc.com**~~ **r e l a i s** ~~pO~~ **5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19** ~~S/SIL465400/A/12/01/2022/GB~~ page 4 / 5 ## **celpac** ~~**[®]**~~ ## _**Thermal specifications**_ **.** **==> picture [224 x 97] intentionally omitted <==** **----- Start of picture text -----**<br> ♦ The curve "1" gives the limits of the product. The tempera-<br>ture reached are acceptable for the components. These val-<br>ues are in compliance with most of SSRs manufacturers. In a<br>cabinet with a minimum of ventilation or a non permanent<br>current, these values are correct.<br>♦ The curve "2" gives the limits of the product according to<br>EN60947-4-3 with a maximum rise temperature of 50°C<br>(@40°C) for a permanent working and in air calm ( test dur-<br>ing 8 hours).<br>**----- End of picture text -----**<br> **==> picture [224 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> ♦ For a non permanent current, you can calcule the average<br>power = Pd x duty cycle and check the rise temperature : ∆Tj<br>= Pd x Rthj/a (Pd and Rthj/a are given page 2)). The junction<br>temperature must not exceed 125°C at the maximum ambient<br>temperature. The maximum current is limited to the size of<br>the thyristors = 50A.<br>**----- End of picture text -----**<br> **==> picture [224 x 37] intentionally omitted <==** **----- Start of picture text -----**<br> ♦ The thermal constant (Cth) of the product is 7 minutes.<br>That means the rise temperature is only 63% of the stabilized<br>temperature after a running time of<br>7 minutes.<br>**----- End of picture text -----**<br> ## _**Overload current**_ **.** 1 - _No repetitive Itsm is given without voltage reapplied . This curve is used for the determination of the protection._ **==> picture [372 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> 2 - Repetitive Itsm is given for inrush current<br>with initial Tj = 70°C. In normal working , this<br>curve musn't be exceed. Be carefull, the Ff nia No repetive<br>repetition of the surge current decrease the<br>lifetime SSR's . g 200 0 ae<br>0<br>fig 3<br>0,01 0,1 t<br>Mounting and dismounting on DIN rail without any tool. Panel Mounting<br>**----- End of picture text -----**<br> ♦ _**Warning** ! semiconductor relays don't provide any galvanic insulation between the load and the mains. Always use in conjunction with an adapted circuit breaker with isolation feature or a similar device in order to ensure a reliable isolation in the event of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...)._ ## **celduc** ® ~~**www.celduc.com**~~ **r e l a i s 5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19** S/SIL465400/A/12/01/2022/GB ## **celpac** ~~**[®]**~~ page 5 /5 GB **==> picture [503 x 102] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||| |---|---|---|---|---|---| |L|wires|L|torques| |Connections|.|screwdriver| |(mm|[2]|)| |♦|For|the output terminals, the wire cross sections must be| |adapted to the load current and to the overcurrent protection device|control| |characteristics. The relay rated voltage must be adapted to the mains|0,4N.m|3,5x0,5mm| |1 x(0,75-->2,5)| |rated voltage.|L = 6mm|(0,6N.m max)| |ai|pS| |♦|celpac|use screw clamp connections.|Power| |1,2N.m|Pozidriv2/| |1x(1,5-->16) 1 x(1,5-->10)| |—|\|oe|L = 10mm|(1,8N.m max)|0,8x5,5 (1x6)| **----- End of picture text -----**<br> ## _**Mounting**_ - ♦ _**Only in vertical position:**_ _The user should protect heat sensitive materials as well as persons against any contacts with the heatsink. For non vertical mounting , the load current must be 50% lower than the rated one . For a good cooling, the SSR needs an air convection. Less convection air produces an abnormal heating. Keep a distance between the upper SSR and the lower SSR. In case of no space between two SSR (zero space between two SSRs) , please reduce the load current. For further details refer to below :_ ♦ _**Derating current with no space between SSRs** AC-51 nominal currents are given with a space of 22,5mm between each SSR, for a_ ~~CE~~ _permanent current during a minimum time of 8 hours in air calm according to IEC60947-4-3. In case of non permanent currents or in case of SSRs are mounted with no space, you must check the heatsink temperature never exceed 90°C. When the SSRs are mounted side to side ( no space between each relay) a derating current of 25% must be take into account._ _A forced cooling ( fan inside the cabinet) improves significantly the thermal performances._ ## _**Typical application :**_ ## _**LOADS**_ _SILD product is designed mainly for AC-51 résistive load. AC-53 motor current are also given . For other loads, check the inrush current at turn ON and possible overvoltages at turn OFF or consult us :_ _* AC-55b : Incandescent lamps : Inrush current is generally 10 times In during few 10ms. So limit the nominal current at about 15A._ - _AC-55a : Electric discharge lamp : These loads often have overcurrent at turn ON and overvoltage at turn OFF, so we advise to use 400VAC SSR on 230VAC mains._ _* AC-56a : Transformers loads : Very high inrush current up to 100 times In . We advise to use random SSR._ ## _**Protection :**_ _To protect the SSR against a short-circuit of the load , use a fuse with a I[2] t value = 1/2 I[2] t value specified page 2. A test has been made with FERRAZ fuse ( see page 2)._ _It is possible to protect SSR by MCB ( miniature circuit breaker). In this case, see application note (_ _SSR protection) and use a SSR with high I[2] t value (5000A[2] s minimum)._ ## _**EMC :**_ - ♦ **Immunity :** _We give in our data-sheets, the immunity level of our SSRs according to the main standards for this type of products : EN61000-4-4 &5. You can see the high immunity level in comparison with the products on the market._ - ♦ **Emission:** _SSRs are complex devices which must be interconnected with other equipment (loads, cables,etc.) to form a system. Because the other equipment or the interconnections may not be under the control of_ **celduc** _, it shall be the responsibility of the system integrator to ensure that systems containing SSRs comply with the requirements of any rules and regulations applicable at the system level.. Consult_ **celduc** _laboratory which can make some tests in your application._ ## **celduc** ® ~~**www.celduc.com**~~ **r e l a i s** **5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →