SG-TL70-DXN2
VISUAL SIGNAL INDICATOR UNITS
- Manufacturer: BANNER ENGINEERING
- Product type: Visual Signal Indicator Units
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 268.7 € |
| Current stock | 10+ |
| Lead time | 30 days |
TL70 Wireless Communication Segment ## Features Sure Cross® Wireless TL70 Tower Lights combine the best of Banner's popular Tower Light family with its reliable, field proven, Sure Cross wireless architecture. ## Benefits - Enables machine monitoring and Overall Equipment Effectiveness by collecting available machine data for analysis and to identify causes of lost production - Lowers the cost and complexity of line and plant reconfigurations - Provides an easy way to implement remote monitoring and the Industrial Internet of Things (IIoT) - Easy Installation —Adds wireless communication and networking capabilities to new or existing TL70 Tower Lights - Power Options —Works with either the standard DC-powered or AC-powered TL70 base - • Input Flexibility —Accepts PNP or NPN inputs • No Constant Power —Uses machine input power for lights and stores power to keep radio in sync - • Industrial Design —Rugged, water-resistant IP65 housing with UV-stabilized material • Event Counter —Configure input wires as auxiliary sourcing inputs from external devices or as a 20 Hz, 32-bit event counter - • Powerful Radio —Available in 900 MHz (1 watt) and 2.4 GHz (65 mW) ISM Bands IMPORTANT: Please download the complete TL70 Wireless Communication Segment technical documentation, available in multiple languages, from www.bannerengineering.com for details on the proper use, applications, Warnings, and installation instructions of this device. IMPORTANT: Por favor descargue desde www.bannerengineering.com toda la documentación técnica de los TL70 Wireless Communication Segment, disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las instrucciones de instalación de estos dispositivos. IMPORTANT: Veuillez télécharger la documentation technique complète des TL70 Wireless Communication Segment sur notre site www.bannerengineering.com pour les détails sur leur utilisation correcte, les applications, les notes de sécurité et les instructions de montage. ## Models **==> picture [465 x 63] intentionally omitted <==** **----- Start of picture text -----**<br> Model Base Color Frequency Input Output<br>SG-TL70-DXN9 Black<br>900 MHz ISM Band<br>SG-TL70-DXN9C Gray Six PNP/NPN discrete, 32-bit Synchronous Event<br>Counter (enabled using DIP switches storing counter Six Discrete Out<br>SG-TL70-DXN2 Black value with inputs 5 and 6)<br>2.4 GHz ISM Band<br>SG-TL70-DXN2C Gray<br>**----- End of picture text -----**<br> Original Instructions 21-Aug-25 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com p/n: 204207 Rev. D TL70 Wireless Communication Segment ## Configuration Instructions ## Set the Radio Module DIP Switches Before applying power to the device, set the radio module's DIP switches. Default configurations are noted with (*). **==> picture [161 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> DIP Switches<br>Bank # 1 (1-4)<br>DIP Switches<br>Bank # 2 (5-8)<br>LED<br>Binding<br>Push Button<br>**----- End of picture text -----**<br> DIP Switch 1 —The 900 MHz radios transmit at 1 Watt (30 dBm) or 250 mW (24 dBm). Refer to your Gateway's datasheet for more information. **==> picture [500 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> DIP Switch 1: Radio Transmit Power 900 MHz Models 2.4 GHz Models<br>OFF * 1 Watt (30 dBm) operation<br>Disabled<br>ON 250 mW (24 dBm) operation<br>**----- End of picture text -----**<br> DIP Switch 2 —Use DIP switch 2 if: - There are no light segments attached to the tower light base; or - In conjunction with DIP switch 5 and constant power to read inputs back to the Gateway and control light segments independently from the Gateway using the output registers. DIP Switch 2: Input Wires 900 MHz Models and 2.4 GHz Models OFF * Input wires control light segments ON Disables input wire control of light segments; input state is still reported back to the Gateway DIP Switch 3 —In the default position (OFF), inputs 1 through 6 control the tower lights. When DIP switch 3 is ON, the input wire for Module 5 is the counter input and the input wire for Module 6 is disabled. Registers 5 and 6 store the 32- bit synchronous counter count. Inputs 5 and 6 are independent from the lights and will not drive any lights they are wired to. Input wires 1 through 4 function normally. Using the counter input requires a TL70 with an 8-pin base to support the additional counting input. **==> picture [500 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> DIP Switch 3: Event Counter 900 MHz Models and 2.4 GHz Models<br>OFF * Default I/O operation<br>ON Configure input 5 as a 32-bit synchronous counter at a maximum frequency of 20 Hz; disable input 6 (the counter<br>requires two registers)<br>**----- End of picture text -----**<br> DIP Switch 4 —Bit packing uses a single register, or range of contiguous registers, to represent I/O values. This allows you to read or write multiple I/O values with a single Modbus message. Input 1 is stored in the least significant bit of register 1. Output 1 is stored in the least significant bit of register 9. DIP switch 4 in the ON position does not work with DIP switch 6 for flashing recognition. **==> picture [500 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> DIP Switch 4: Bit Packing I/O 900 MHz Models and 2.4 GHz Models<br>OFF * Default I/O operation<br>ON Bit-packed I/O with all inputs in Modbus register 1 and all outputs in Modbus register 9. All other Modbus registers<br>are disabled.<br>**----- End of picture text -----**<br> DIP Switch 5 —Enabling dc-powered mode with DIP switch 5 configures the input wire for Module 6 to accept a constant 24 V dc input. The TL70 can still accept inputs for up to 5 tower light segments and remotely control light segments from the Gateway. **==> picture [500 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> DIP Switch 5: Configure DC Power Mode 900 MHz Models and 2.4 GHz Models<br>OFF * Default I/O operation<br>ON Enable dc-powered mode and remote light segment control<br>**----- End of picture text -----**<br> DIP Switch 6 —Enables the TL70 Wireless Node Segment to recognize a 0.8 Hz to 6 Hz flashing state produced on the input. This feature allows each light segment attached to have two separate states that can be recognized and tracked for reporting or triggering rules/functions when paired with the DXM100 Wireless Controller. The input register will alternate between a value of 2 and 3 when the flashing state is active. DIP switch 6 in the ON position cannot be used in conjunction with DIP switch 4 (ON position). page 2 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 21-Aug-25 TL70 Wireless Communication Segment **==> picture [500 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> DIP Switch 6: Enable Flash Recognition 900 MHz Models and 2.4 GHz Models<br>OFF * Default I/O operation (Input register values: 0 = OFF, 1 = ON)<br>ON Enables flash recognition (Input register values: 0 = OFF, 1 = ON, 2 = Flashing OFF, 3 = Flashing ON)<br>**----- End of picture text -----**<br> DIP Switch 7 —Allows the user to trigger the output of a light in a specific flash pattern. To use this feature constant power is required and DIP switch 5 must be turned ON. See "Creating Host Controlled Flash Patterns" on page 5 for more information. **==> picture [500 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> DIP Switch 7: Enable Host Controlled Flash Patterns 900 MHz Models and 2.4 GHz Models<br>OFF * Default I/O operation<br>ON Enables host controlled flash patterns<br>**----- End of picture text -----**<br> ## Event Counter To use the event counter, the measured (logic high) signal must be greater than or equal to 25 ms. The 32-bit count is stored in I/O registers 5 and 6. To zero out (clear) the event counter, - Map an input/button on a Gateway to Node register 14 to clear the counter when the input/button is activated; or - From a host system, write a 1 (the output must transition from a zero to a one to reset the counter) to Node register 14 or write a 5424 (0x1530) to Node control register 15. RF firmware revision 5.3 or higher (on all products released after 3/20/2015) is required to use this feature. **==> picture [114 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> Correct<br>Incorrect<br>t = 0 25 ms 50 ms 75 ms 100 ms<br>**----- End of picture text -----**<br> ## Bind the TL70 to the Gateway and Assign the Node Address Before beginning the binding procedure, apply power to all the devices. 1. Enter binding mode. - For housed Gateways, triple-click button 2. - For board-level Gateway modules, triple-click the button. - ◦ For DXMs, under the ISM Radio menu, use the down arrow button to highlight the Binding menu. Click ENTER . **==> picture [94 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> DIP Switches<br>Bank # 1 (1-4)<br>DIP Switches<br>Bank # 2 (5-8)<br>LED<br>Binding<br>Push Button<br>**----- End of picture text -----**<br> On the board modules, the green/red LED flashes. On the housed models, both LEDs flash red. 2. Assign the TL70 a Node address using the Gateway's rotary dials or the DXM's arrow keys. - On a Gateway: Use the left rotary dial for the left digit and the right rotary dial for the right digit. For example, to assign your TL70 to Node 01, set the left dial to 0 and the right dial to 1. - On the DXM: Use the arrow keys to select the Node ID, then press ENTER . The display shows Binding . - Valid Node addresses are 01 through 47. 3. Access the circuit board in the radio module of the TL70. 4. Enter binding mode on the TL70 by triple-clicking the binding button. The bicolor LED flashes alternately while it searches for a Gateway in binding mode. After the TL70 is bound, the LED is red and green for four seconds (looks amber), then it flashes four times (looks amber). The TL70 automatically exits binding mode, cycles power, and enters Run mode. 5. For DXMs, click BACK to exit binding for that specific Node address. 6. Label the Node with the assigned address for future references. - This makes it easier to identify the physical Node location within a multi-Node network. 7. Reassemble the components back onto the base. 8. Repeat steps 2 through 5 for as many TL70 Wireless Communication Segments as are needed for your network. 9. After binding all TL70s, exit binding mode on the Gateway. - For housed Gateways, double-click button 2. - ◦ For board-level Gateway modules, double-click the button. ◦ For DXM models, click BACK until you return to the main menu. ## LED Behavior for the Nodes Nodes do not sample inputs until they are communicating with the Gateway. The radios and antennas must be a minimum distance apart to function properly. Recommended minimum distances are: - 900 MHz radio transmitting at ≤ 250 mW: 6 feet - 900 MHz radios transmitting at ≥ 500 mW: 15 feet - 2.4 GHz radios transmitting at 65 mW: 1 foot © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 3 of 8 21-Aug-25 TL70 Wireless Communication Segment **==> picture [488 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> LED (Bi-color) Node Status<br>Flashing green Radio link okay<br>Green and red flashing alternately In Binding mode<br>Both colors are solid for 4 seconds, then flash 4 times; looks amber Binding mode is complete<br>Flashing red, once every 3 seconds Radio link error<br>Flashing red, once every second Device error<br>Assemble the TL70 Wireless Communication Segment<br>To assemble the modules:<br>1. Position the TL70 Wireless Communication Segment on the base. The<br>communication segment must mount directly to the TL70 base.<br>(= 2. Align the notches on each module and press together.<br>—s 3. Rotate the top module clockwise to lock into place (notches shown in the locked position).<br>4. Assemble the remaining modules in the desired order.<br>Align the notches Notches shown in locked position Follow the instructions and wiring diagrams on the TL70 Modular Tower Light<br>datasheet, using either the standard or AC voltage base for triggering appropriate<br>inputs.<br>**----- End of picture text -----**<br> ## Assemble the TL70 Wireless Communication Segment ## Sure Cross® DX80 Performance Configuration Software The configuration software offers an easy way to link I/O points in your wireless network, view I/O register values, and set system communication parameters when a host system is not part of the wireless network. The software runs on any computer with the Windows Vista, Windows 7, Windows 8, or Windows 10 operating system. **==> picture [88 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Device Configuration screen<br>**----- End of picture text -----**<br> Use a USB to RS-485 adapter cable to connect a standalone DX80 Gateway to the computer. For DXM Controllers with an internal DX80 radio, connect a computer to the DXM Controller using the supplied USB or Ethernet connection. Download the most recent revisions of the configuration software from Banner Engineering's website: https://www.bannerengineering.com/us/en/products/wireless-sensor-networks/ reference-library/software.html. The USB to RS-485 adapter cable is not required for the DXM Controller. For standalone DX80 Gateway devices use: - USB to RS-485 adapter cable model BWA-UCT-900 for 1 Watt radios - USB to RS-485 adapter cable model BWA-HW-006 for all other radios ## Modbus Registers Modbus holding registers for the 8-pin models. On 5-pin models, the M5 and M6 modules are not available. When DIP Switch 7 and 5 are enabled, the I/O range for all outputs is up to 0xFFFF, based on which flash pattern message is being created. Input register values: 0 = OFF, 1 = ON and if DIP Switch 6 is enabled then 2 = Flashing OFF, 3 = Flashing ON is added. page 4 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 21-Aug-25 TL70 Wireless Communication Segment **==> picture [500 x 263] intentionally omitted <==** **----- Start of picture text -----**<br> Modbus Holding Register I/O Range Holding Register Module #<br>I/O I/O Type Representation (Dec.)<br>Gateway Any Node Min. Max. Min. Max.<br>1 1 1 + (Node# × 16) Discrete IN 1 / Bit-packed inputs ¹ 0 3 / 63 0 3 / 63 M1<br>2 2 2 + (Node# × 16) Discrete IN 2 0 3 0 3 M2<br>3 3 3 + (Node# × 16) Discrete IN 3 0 3 0 3 M3<br>4 4 4 + (Node# × 16) Discrete IN 4 0 3 0 3 M4<br>5 5 5 + (Node# × 16) Discrete IN 5 / 32-bit event counter high word ² 0 3 / 65535 0 3 / 65535 M5<br>6 6 6 + (Node# × 16) Discrete IN 6 / 32-bit event counter low word ² 0 3 / 65535 0 3 / 65535 M6<br>7 7 7 + (Node# × 16) Reserved<br>8 8 8 + (Node# × 16) Device Message<br>9 9 9 + (Node# × 16) Discrete OUT 9 / Bit-picked outputs ¹ 0 1 / 63 0 1 / 63 M1<br>10 10 10 + (Node# × 16) Discrete OUT 10 0 1 0 1 M2<br>11 11 11 + (Node# × 16) Discrete OUT 11 0 1 0 1 M3<br>12 12 12 + (Node# × 16) Discrete OUT 12 0 1 0 1 M4<br>13 13 13 + (Node# × 16) Discrete OUT 13 0 1 0 1 M5<br>14 14 14 + (Node# × 16) Discrete OUT 14 / Zero out (clear) the counter ² 0 1 0 1 M6<br>15 15 15 + (Node# × 16) Control Message<br>16 16 16 + (Node# × 16) Reserved<br>**----- End of picture text -----**<br> ¹Active when DIP Switch 4 is enabled ²Active when DIP Switch 3 is enabled ## Creating Host Controlled Flash Patterns When DIP switch 7 is enabled, a host controlled system can write a value of 0x0000 to 0xFFFF to an output register to enable that light segment in that specific flash pattern. Flash a TL70 light by entering a time-based bit mask into the output register. Bit 0 represents the first 62.5 ms time window, bit 1 represents the second 62.5 ms window, etc. For example, turn ON the output from 0 to 250 ms, OFF from 250 to 500 ms, ON from 500 to 750 ms, then OFF again from 750 ms to 1 second by writing 0x0F0F to the appropriate output. **==> picture [500 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0<br>Bin 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1<br>Hex 0 F 0 F<br>Light Turned off from 750 ms to 1 s Turned on from 500 to 750 ms Turned off from 250 to 500 ms Turned on from 0 to 250 ms<br>**----- End of picture text -----**<br> ## Specifications ## Performance Radio with Internal Antenna Specifications Radio Transmit Power (900 MHz, 500 mW radios) Conducted: 27 dBm (500 mW) EIRP with the supplied antenna: < 36 dBm - Radio Transmit Power (2.4 GHz radios) - Conducted: < 18 dBm (65 mW) - EIRP with the supplied antenna: < 20 dBm (100 mW) ## Antenna Minimum Separation Distance - 900 MHz radios transmitting at ≥ 500 mW: 4.57 m (15 ft) with the supplied antenna - 2.4 GHz radios transmitting at 65 mW: 0.3 m (1 ft) with the supplied antenna ## Radio Range A 2 dB antenna ships with this device. Transmit power and range are subject to many factors, including antenna gain, installation methods, characteristics of the application, and environmental conditions. Please refer to the following documents for installation instructions and high-gain antenna options. Installing Your Sure Cross® Radios (151514) Conducting a Site Survey (133602) Sure Cross® Antenna Basics (132113) ## Link Timeout (Performance) Gateway: Configurable via User Configuration Software Node: Defined by Gateway © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 5 of 8 21-Aug-25 TL70 Wireless Communication Segment ## Spread Spectrum Technology FHSS (Frequency Hopping Spread Spectrum) 900 MHz Compliance (SX7023EXT Radio Module) Radio module is indicated by the product label marking Contains FCC ID: UE3SX7023EXT Contains IC: 7044A-SX7023EXT ## 2.4 GHz Compliance (SX243 Radio Module) Radio module is indicated by the product label marking Contains FCC ID: UE3SX243 Radio Equipment Directive (RED) 2014/53/EU Contains IC: 7044A-SX243 ## Tower Light Specifications ## Supply Voltage and Current 12 V DC to 30 V DC (Outside the USA: 12 V DC to 24 V DC, ± 10%)[(1)] 900 MHz Consumption: Maximum current draw is < 40 mA and typical current draw is < 30 mA at 24 V DC. (2.4 GHz consumption is less.) |Indicator Color or Audible Model|Maximum Current (mA)|Maximum Current (mA)| |---|---|---| ||at 12 V DC|at 30 V DC| |Blue, Green, White|420|150| |Red, Yellow, Orange|285|120| |Standard Audible|30|30| |Loud Audible (Intensity 1)|18|14| |Loud Audible (Intensity 2)|40|28| |Loud Audible (Intensity 3)|160|70| |Loud Audible (Intensity 4)|350|110| ## Supply Protection Circuitry ## Protected against transient voltages ## Audible Alarm Standard Audible: 2.6 KHz ± 250 Hz oscillation frequency; maximum intensity (typical) 92 dB at 1 m (3.3 ft) Loud Audible: 2.6 KHz ± 250 Hz oscillation frequency; maximum intensity (typical) at 1 m (3.3 ft) |DIP Switches|DIP Switches|Maximum Intensity (typical) at 1 meter dB| |---|---|---| |9|10|| |ON|ON|Intensity 4: 109 dB| |OFF|ON|Intensity 3: 106 dB| |ON|OFF|Intensity 2: 101 dB| |OFF|OFF|Intensity 1: 94 dB| ## Audible Adjustment Standard Audible: Rotate the cover until the desired volume is reached Loud Audible Adjustment: Select the desired volume using DIP switches 9 and 10 Typical Reduction in Sound Intensity with Audible Adjustment (maximum to minimum): ## Connections 5-pin M12 quick disconnect, 8-pin M12 quick disconnect, 150 mm (5.9 in) PVC cable with an M12 quick disconnect, or 2 m (6.5 ft) unterminated cable, depending on model ## Construction Bases, Segments, Covers: Polycarbonate ## Vibration and Mechanical Shock Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC 60068-2-6 Shock: 15G 11 ms duration, half sine wave per IEC 60068-2-27 ## Indicator Characteristics ||Color<br>Coordinates(2)|Color<br>Coordinates(2)| |---|---|---| ||x|y| |525 nm|–|–| |625 nm|–|–| |590 nm|–|–| |470 nm|–|–| |5000 K|–|–| ||0.66|0.33| ## Operating Conditions –40 °C to +50 °C (–40 °F to +122 °F) 95% at +50 °C maximum relative humidity (non-condensing) Environmental Rating IP65 Radiated Immunity HF 10 V/m (EN 61000-4-3) ## Certifications CE/UKCA approval only applies to 2.4 GHz models Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM Turck Banner LTD Blenheim House Blenheim Court Wickford, Essex SS11 8YT GREAT BRITAIN - Standard Audible: 8 dB - • Loud Audible: 16 dB ## Indicators 1 to 6 colors depending on model (Green, Red, Yellow, Blue, White, and Orange) LEDs are independently selected Flash Rates: 1.5 Hz ±10% and 3 Hz ±10% **==> picture [61 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 03737-22-04042<br>**----- End of picture text -----**<br> ## Indicator Response Time Off Response: 150 µs (maximum) at 12 V DC to 30 V DC On Response: 180 ms (maximum) at 12 V DC; 50 ms (maximum) at 30 V DC (1) For European applications, power this device from a Limited Power Source as defined in EN 60950-1. (2) Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. page 6 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 21-Aug-25 TL70 Wireless Communication Segment ## Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. **==> picture [208 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Supply|Supply| |Required Overcurrent|Required Overcurrent| |Wiring|Wiring| |Protection (A)|Protection (A)| |(AWG)|(AWG)| |20|5.0|26|1.0| |22|3.0|28|0.8| |24|2.0|30|0.5| **----- End of picture text -----**<br> ## Dimensions **==> picture [186 x 174] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Model|Height (H)| |1 light module|87.6 mm (3.45 in)| |1 light module, 1 audible module|144.3 mm (5.68 in)| |2 light modules|137.3 mm (5.41 in)| |2 light modules, 1 audible module|194 mm (7.64 in)| |3 light modules|187 mm (7.36 in)| |3 light modules, 1 audible module|243.7 mm (9.59 in)| |4 light modules|236.7 mm (9.32 in)| |4 light modules, 1 audible module|293.4 mm (11.55 in)| |5 light modules|286.4 mm (11.28 in)| |5 light modules, 1 audible module|343.1 mm (13.5 in)| |6 light modules|336.1 mm (13.23 in)| **----- End of picture text -----**<br> **==> picture [119 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> M30 × 1.5<br>(mounting nutincluded) 24.9 mm<br>L [0.98”]<br>Internal threads =<br>1/2-14 NPT<br>Max Torque: 2.25 Nm<br>[20 in-lbf] M12 × 1<br>**----- End of picture text -----**<br> ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. ## Notas Adicionales (con Antena) Información México: La operación de este equipo está sujeta a las siguientes dos condiciones: 1) es posible que este equipo o dispositivo no cause interferencia perjudicial y 2) este equipo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada. Banner es una marca registrada de Banner Engineering Corp. y podrán ser utilizadas de manera indistinta para referirse al fabricante. "Este equipo ha sido diseñado para operar con las antenas tipo Omnidireccional para una ganancia máxima de antena de 6 dBd y Yagi para una ganancia máxima de antena 10 dBd que en seguida se enlistan. También se incluyen © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 7 of 8 21-Aug-25 TL70 Wireless Communication Segment aquellas con aprobación ATEX tipo Omnidireccional siempre que no excedan una ganancia máxima de antena de 6dBd. El uso con este equipo de antenas no incluidas en esta lista o que tengan una ganancia mayor que 6 dBd en tipo omnidireccional y 10 dBd en tipo Yagi, quedan prohibidas. La impedancia requerida de la antena es de 50 ohms." Approved Antennas BWA-9O2-C --Antena, Omni 902-928 MHz, 2 dBd, junta de caucho, RP-SMA Macho BWA-9O5-C --Antena, Omni 902-928 MHz, 5 dBd, junta de caucho, RP-SMA Macho BWA-9O6-A --Antena, Omni 902-928 MHz, 6 dBd, fibra de vidrio, 1800mm, N Hembra BWA-9Y10-A --Antena, Yagi, 900 MHz, 10 dBd, N Hembra ## Mexican Importer Banner Engineering de Mèxico, S. de R.L. de C.V. | David Alfaro Siqueiros 103 Piso 2 Valle oriente | San Pedro Garza Garcia Nuevo Leòn, C. P. 66269 81 8363.2714 page 8 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 21-Aug-25
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →