SEM310
Temperature Transmitter, HART, In Head, Universal Input, 4 to 20 mA Output
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: STATUS
- Product type: Signal Converters
- Signal Conditioner Input:Resistance, RTD, Thermocouple, Voltage; Signal Conditioner Output:Current; No. of Output Channels:1Channels; Accuracy %:-; Output Accuracy:-; Supply Voltage:40VDC; N
- SVHC: No SVHC (04-Feb-2026)
- Accuracy %: -
- Product Range: -
- Supply Voltage: 40VDC
- Isolation Input: Isolated
- No. of Channels: 2 Channel
- Output Accuracy: -
- No. of Output Channels: 1Channels
- Signal Conditioner Input: Resistance, RTD, Thermocouple, Voltage
- Signal Conditioner Output: Current
- Signal Conditioner Mounting: Panel Mount
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 246.97 € |
| Current stock | 10+ |
| Lead time | 30 days |
SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER **HART 5,6,7 COMPATIBLE** **UNIVERSAL INPUT, DUAL CHANNEL[*1]** **ATEX, UKEX & IEC Ex VERSION** ~~a~~ **MATHS FUNCTIONS** **SIL HARDWARE SAFETY INTEGRITY** ## **INTRODUCTION** The SEM310 is a HART 5 upwards, (generic device) compatible universal transmitter. It accepts RTD, Thermocouple, Potentiometer or millivolt input signals and converts them to the industry standard (4 to 20) mA transmission signal. Alternatively, HART multidrop mode can be selected. The SEM310 is programmed using a standard USB lead. The ATEX / UKEX / IECEx version (SEM310X) is programmed with a ATEX / UKEX / IECEx approved communication lead (USBX Config). Both versions use our free configuration USBSpeedlink software downloaded from our web site. Standard features can also be programmed using HART communication. ## **FEATURE HIGHLIGHTS** ## **SENSOR REFERENCING** The SEM310 sensor referencing via the Windows based USBSpeedlink software allows for close matching to a known reference sensor eliminating possible sensor errors. ## **USER CALIBRATION** In addition to sensor referencing, current output trimming is possible via the USB and HART commands. ## **CUSTOM LINEARISATION** The SEM310 can be programmed with a custom linearization to suit nonstandard sensors or sensors with unusual or unique characteristics. Consult the sales office for details. ## **SENSOR BURN OUT DETECTION** If a sensor wire is broken or becomes disconnected the SEM310 output will automatically go to its user defined level (upscale or downscale) or pre-set value. ## **OUTPUT CURRENT PRESET** For ease of system calibration and commissioning the output can be set to a pre-defined level anywhere within the (4 to 20) mA range. Hart **[®]** Registered trademark of the HART Communication Foundation. - ***1** Dual channel input not available on slide wire or multi wire RTD. D2579-01-14 SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER |**ELECTRICAL INPUTSPECIFICATIONS @20°C**|**ELECTRICAL INPUTSPECIFICATIONS @20°C**|**ELECTRICAL INPUTSPECIFICATIONS @20°C**| |---|---|---| |**Range+ Options**|**Accuracy**|**Stability**| |**Resistance**||| |(10 to 10000) Ω<br>Excitation 200 uA<br>Lead resistance (0 to 20) Ω<br>(2,3 or 4 Wire connection)|(10 to 500) Ω ± 0.055 Ω,<br>(500 to 2500) Ω ± 0.5 Ω,<br>(2500 to 10500) Ω ±0.2 % of reading<br>(+Lead error on 2 wire)|(0 to 500) Ω 0.013 Ω/°C,<br>(500 to 2500) Ω 0.063 Ω/°C,<br>(2500 to 10500) Ω 0.27 Ω/°C| |**Slide wire**||| |(0 to 100) % Travel<br>Wire resistance (1 to 100) K**Ω**|± 0.1 %|±0.001%/°C| |**mV**||| |(-205 to 205) mV DC<br>(-1000 to 1000) mV DC|±0.02 mV<br>±10.0 mV|±0.005 mV/°C<br>±0.02 mV/°C| |**SENSOR INPUTSPECIFICATIONS @20°C**<br>**RTD (Single/ 2 wire Dual Channel; isolated tip only for Dual operation)**|**SENSOR INPUTSPECIFICATIONS @20°C**<br>**RTD (Single/ 2 wire Dual Channel; isolated tip only for Dual operation)**|**SENSOR INPUTSPECIFICATIONS @20°C**<br>**RTD (Single/ 2 wire Dual Channel; isolated tip only for Dual operation)**| |---|---|---| |**Type**|**Range**|**Accuracy/ Stability**| |Pt100 (IEC)|(-200 to 850)°C|0.2°C ± (°0.05% of reading)<br>(Plus sensor error)| |Pt500 (IEC)|(-200 to 850)°C|| |Pt1000 (IEC)|(-200 to 600)°C|| |Ni100|(-60 to 180)°C|| |Ni120|(-70 to 180)°C|| |Ni1000|(-40 to 150)°C|| |Cu53|(-40 to 180)°C|| |Cu100|(-80 to 260)°C|| |Cu1000|(-80 to 260)°C|| |Library contains more (standards/types) Including silicon sensors||| |Temperature stability:-Refer to resistance stability values for thermal effect||| |**SENSOR INPUTSPECIFICATIONS @20°C**<br>**Thermocouple (Single/Dual Channel; isolated tip only for Dual operation)**|**SENSOR INPUTSPECIFICATIONS @20°C**<br>**Thermocouple (Single/Dual Channel; isolated tip only for Dual operation)**|**SENSOR INPUTSPECIFICATIONS @20°C**<br>**Thermocouple (Single/Dual Channel; isolated tip only for Dual operation)**| |---|---|---| |**Type**|**Range**|**Accuracy/ Stability**| |K|(-150 to 1370)°C|±0.1 % of full scale ± 0.5 °C<br>(Plus sensor error)| |J|(-200 to 1200)°C|| |N|(-270 to 1300)°C|| |E|(-260 to 1000)°C|| |T|(-150 to 400) °C|±0.2 % of full scale ± 0.5 °C<br>(Plus sensor error)| |R|(0 to 1760)°C|±0.1 % of full scale ± 0.5 °C<br>over range (800 to 1760) °C<br>(Plus sensor error)| |S|(0 to 1760) °C|| |L|(-200 to 900)°C|±0.1 % of full scale ± 0.5 °C<br>(Plus sensor error)| |U|(-200 to 600)°C|| |B|(0 to 1820)°C|| |C|(0 to 2300)°C|| |D|(0 to 2300)°C|| |G|0 to 2300)°C|| |Library contains more (standards/types)||| |Temperature stability: - RefertomVstabilityvaluesforthermaleffect||| D2579-01-14 SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER |**COLD JUNCTION (Ambient sensor)**|**COLD JUNCTION (Ambient sensor)**|**COLD JUNCTION (Ambient sensor)SPECIFICATIONS @20°C**| |---|---|---| |**Type**|**Range**|**Accuracy/Stability**| |Thermistor 10K Beta 3380|(-40 to 85)°C|±0.2°C| |Thermal drift|Zero at 20°C|±0.05°C/°C| |||| |**DUAL CHANNEL OPERATION**||| |Thermocouples A & B|Functions; Average, Redundancy, A+B, A|B, A–B, Highest, Lowest| |mV A & B|Functions; Average, A+B, A–B, Highest, Lowest|| |RTD A&B|Twowire connection. Functions;Average,A + B,A – B,Highest,Lowest|| |**OUTPUTSPECIFICATIONS @20°C**|**OUTPUTSPECIFICATIONS @20°C**|**OUTPUTSPECIFICATIONS @20°C**| |---|---|---| |**Type/ options**|**Range**|**Accuracy/ Stability/ Notes**| |Two wire current|(4 to 20) mA|(mA Out/ 2000) or 5 uA<br>whichever is the greater| |Thermal drift|Zero at 20°C|1 uA/°C| |User set minimum current|(3.5 to 4.0) mA 3.8 mA default|| |User set maximum current|(20 to 23.0) mA<br>20.5 mA default|| |User set error current|(3.5 to 23.0) mA|| |User pre-set current|(20 to 23.0) mA|For diagnostics| |Current loop off|3.5 mA|| |Loop effect|± 0.2 uA/V|| |Loop supply|(10 to 30) V DC,>35 mA|SELV| |Max load|[(V supply–10)/20] KΩ|700 Ω @ 24 V DC| |Protection|Reverse and over voltage|| |**USB USER INTERFACE, required to access advanced functionality options**<br>Approved USB configuration lead required for SEM310X|**USB USER INTERFACE, required to access advanced functionality options**<br>Approved USB configuration lead required for SEM310X|**USB USER INTERFACE, required to access advanced functionality options**<br>Approved USB configuration lead required for SEM310X| |---|---|---| |**Type/ Options/ Function**|**Description**|**Notes**| |USB 2.0|Mini B USB<br>Approved configuration lead<br>SEM310X|USB powers device for config<br>Only. Power loop for live data.| |Baud Rate|38,400|| |Sensor configuration|Sensor type<br>Sensor offset<br>Sensor fail high or low<br>Pre-set sensor value<br>Set damping<br>Set No. wires resistance Input<br>Set fixed or auto cold junction|TC/mV/RTD/Ohms/Slide wire<br>Dual TC/mV/RTD<br>Dual use separate offsets<br>Dual Share sensor fail<br>For diagnostics<br>2, 3 or 4 wire| |Profiler configuration|Set profiler input range<br>Set profiler segments<br>Enter profile X~Y values<br>Set profiler output units<br>Set the output process range<br>TC & RTD input only set units|In sensor units<br>(4 to 22) segments<br>Profiler set up| |Output signal|Select the process range for<br>re-transmission<br>Set minimum current<br>Set maximum current<br>Set the error current<br>Trim 4.0 mA signal<br>Trim 20 mA signal<br>Pre-set Loop current|Set in profiler out units<br>(3.5 to 4.0) mA<br>(20 to 23.0) mA<br>(3.5 to 23.0) mA<br>(3.8 to 4.5) mA<br>(19.5 to 20.5) mA<br>(3.5 to 23.0) mA| D2579-01-14 SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER |Damping|User set process variable (PV)<br>damping|(1 to 32) seconds to reach 70% of final<br>value| |---|---|---| |Diagnostics|Read (PV, mA, ambient °C,<br>error & power off) logs points<br>back from device<br>Set the log period<br>Clear log and start new log<br>Export log data<br>Detect open circuit sensor wire<br>Calibration date, certificate<br>number, calibrated by|Up to 150 points<br>Log Rate (1 to 60) readings per hour| |Live Data|Read process variable (PV)<br>Read profiler input signal<br>Read profiler output signal<br>Read ambient temperature<br>Read % output<br>Read mA output|| |HART information|Read/write tag number<br>Read/write tag date<br>Set polling address<br>Read/write description<br>Read/write message<br>Read/write final assembly<br>number<br>Read/write long tag|| |HART specification|Read manufacturers ID<br>Read short ID<br>Read HART revision<br>Read device revision<br>Read software revision<br>Read hardware revision<br>Read unique ID<br>Read No. pre-ambles<br>Read maximum No. variables<br>Read No. of configuration<br>changes<br>Extended device status<br>Extended manufacturers ID<br>Extended distributes ID<br>Device profile<br>Device ID1, ID2 & ID3|| D2579-01-14 SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER ## **HART INTERFACE** |**Type/ options/ function**|**Description**|**Notes**| |---|---|---| ||1.Read primary variable (PV)|| ||2.Read loop current and|| ||percentage of range|| ||3.Read dynamic variables and|| ||Loop current|| |HART Protocol 1200 baud FSK|7.Read loop configuration|| ||8.Read dynamic variable|| |Version HART 5 to 7|classifications|| |compatible|9.Read device variables with|| ||status|| |Universal commands|12.Read message|| ||13.Read tag, descriptor and|| ||date|| ||14.Read primary variable|| ||transducer Information|| ||15.Read device information|| ||16.Read final assembly|| ||number|| ||17.Write message|| ||18.Write tag, descriptor and|| ||date|| ||19.Write final assembly|| ||number|| ||20.Read long tag|| ||22.Write long tag|| ||38.Reset configuration|| ||changed flag|| ||48.Read additional device|| ||status|| ||0. Read unique ID|| |Additional universal|6. Write polling address|| |commands|11. Read unique ID associated|| ||with tag|| ||21. Read unique ID associated|| ||with long tag|| ||34. Write PV damping value|| ||35. Write PV range|| ||40. Enter/exit fixed current|| ||mode|| |Common practice|41. Perform self-test|| |commands|42. Perform device reset|| ||45. Trim loop current zero|| ||46. Trim loop current gain|| ||49. Write primary variable|| ||transducer serial number|| ||71. Lock device|| ||76. Read lock device state|| D2579-01-14 SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER |**GENERAL**|**GENERAL**| |---|---| |**Function**|**Description**| |Isolation|Flash tested 5 Seconds 4 KV DC, working voltage 50 V AC| |Reading update|200 ms| |Response time|500 ms to reach 70% final value| |Warm up|2 minutes| |Start-up time|5 seconds| |**AMBIENT**<br>**Function**<br>**Description**<br>Temperature<br>Operating/Storage (-40 to 85)°C<br>Humidity<br>Operating/Storage (10 to 90) %RH non-condensing<br>Protection<br>>=IP65<br>USB configuration ambient<br>(10 to 30)°C<br>~~———~~|**AMBIENT**<br>**Function**<br>**Description**<br>Temperature<br>Operating/Storage (-40 to 85)°C<br>Humidity<br>Operating/Storage (10 to 90) %RH non-condensing<br>Protection<br>>=IP65<br>USB configuration ambient<br>(10 to 30)°C<br>~~———~~|**AMBIENT**<br>**Function**<br>**Description**<br>Temperature<br>Operating/Storage (-40 to 85)°C<br>Humidity<br>Operating/Storage (10 to 90) %RH non-condensing<br>Protection<br>>=IP65<br>USB configuration ambient<br>(10 to 30)°C<br>~~———~~| |---|---|---| ||**MECHANICAL**|| ||Enclosure|DIN standard size terminal block| ||Material|ABS flammability UL94-VO| ||Dimensions|44 mm diameter 24 mm height| ||Weight|Approximately 43 g| ||Fixing centres|33 mm| ||Centre hole|6.35 mm| ||Colour|Black SEM310, Blue SEM310X| **CONNECTIONS Function Description** Output Screw terminals (1 to 2) Input Screw terminals (3 to 6) ~~SSS~~ USB Mini USB for SEM310, approved configuration lead for SEM310X **APPROVALS** EMC BS EN 61326 Industrial Ingress protection BS EN 60529 RoHS Directive 2011/65/EU Incorporating Amendment Directive EU2015/863 and UK designated standard. SIL Accreditation IEC 61508-2: 2010 clauses 7.4.4 and 7.4.5 ATEX / UKEX SEM310X Ex ia IIC T4 Ga Ex ia IIIC T135 Da IECEx SEM310X Ex ia T4 Ga Ex ia IIIC T135 Da **ORDER CODE** STANDARD SEM310 ATEX / UKEX SEM310X ~~—_—_=~~ **ACCESSORIES** USB configuration software USBSpeedLink free of charge from www.status.co.uk USB programming lead USB programming lead part number 42-200-0001-01 ATEX / UKEX programming lead USBX Head enclosure options Refer to www.status.co.uk ~~——~~ Probe options Refer to www.status.co.uk To maintain full accuracy annual calibration is required contact sales@status.co.uk for details The data in this document is subject to change. Status Instruments assumes no responsibility for errors Status Instruments Ltd Tel: +44 (0)1684 296818 Status Business Park Fax: +44 (0)1684 293746 Gannaway Lane, Tewkesbury Email: sales@status.co.uk Gloucestershire, UK Website: www.status.co.uk GL20 8FD D2579-01-14
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →