SDX01D4
Pressure Sensor, Calibrated, -40 to 85°C, 1 psi, Analogue, Absolute, 20 V, Dual Axial
- Manufacturer: HONEYWELL
- Product type: Pressure Transducers
- Port Style: Dual Axial
- Product Range: SDX Series
- Sensor Output: Analogue
- Voltage Rating: 20V
- Operating Pressure Max: 1psi
- Pressure Measurement Type: Absolute
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 57.2 € |
| Current stock | 10+ |
| Lead time | 30 days |
## SDX Series Plastic Silicon Pressure Sensors Low Cost, Temperature Compensated, DIP, 0 psi to 1 psi, 0 psi to 100 psi ## **DESCRIPTION** The SDX Series sensors provide a very cost-effective solution for pressure applications that require small size plus performance. These calibrated and temperature-compensated sensors give an accurate and stable output over a 0 °C to 50 °C [32 ° F to 122 ° F] temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air and dry gases. Devices are available to measure absolute and gage pressures from 1 psi (SDX01) up to 100 psi (SDX100). The absolute devices have an internal vacuum reference and an output voltage proportional to absolute pressure. The SDX devices are available in standard commercial and prime grades (SDCXXXXX **-A** ) to allow optimization of accuracy and cost in any given application. The SDX devices feature an integrated circuit (IC) sensor element and laser trimmed thick film ceramic housed in a compact solvent resistant case. The package is a double-wide, dual-inline package (DIP). This is the same familiar package used by IC manufacturers except it is only 11,94 mm [0.470 in] long and has a pressure port(s). The PC board area used by each DIP is approximately 0.26 in2. This extremely small size enables the use of multiple sensors in limited available space. The DIP provides excellent corrosion resistance and isolation to external package stress. The DIP mounts on a PC board like a standard IC with through-hole pins. The pins anchor the pressure sensor to the PC board and provide a more secure and stable unit than other types of packages. The output of the bridge is ratiometric to the supply voltage and operation from any dc supply voltage up to 20 Vdc is acceptable. ## **FEATURES** - Low cost DIP - Precision temperature compensation - Calibrated zero and span - Small size ## **POTENTIAL APPLICATIONS** - Medical equipment - Computer peripherals - Pneumatic controls - HVAC - Low noise - High impedance for low power applications - Prime grade available (SDXxxxyy-A) ## **SDX Series** **Table 1. Pressure Range Specifications and Ordering Information** |**Catalog Listing, Pressure Connection,**<br>**Pressure Type**|**Catalog Listing, Pressure Connection,**<br>**Pressure Type**|**Catalog Listing, Pressure Connection,**<br>**Pressure Type**|**Catalog Listing, Pressure Connection,**<br>**Pressure Type**|**Operating**<br>**Pressure**|**Operating**<br>**Pressure**|**Proof**<br>**Pressure**<br>(2)|**Full-Scale Span**<br>**(1)**|**Full-Scale Span**<br>**(1)**|**Full-Scale Span**<br>**(1)**|**Full-Scale Span**<br>**(1)**| |---|---|---|---|---|---|---|---|---|---|---| |**Gage**|**Differential/Gage**||**Absolute**||||**Min.**||**Typ. **|**Max.**| |SDX01G2|SDX01D4||`-`|0 psid to 1 psid||20 psid|17.37 mV||18.00mV|18.18mV| |SDX01G2-A|SDX01D4-A||`-`||||17.82 mV||18.00mV|18.80mV| |SDX05G2|SDX05D4||`-`|0 psid to 5 psid||20 psid|57.90mV||60.00mV|62.10mV| |SDX05G2-A|SDX05D4-A||`-`||||59.40mV||60.00mV|60.60mV| |SDX15G2|SDX15D4||`-`|0 psid to 15 psid||30 psid|86.85mV||90.00mV|93.15mV| |SDX15G2-A|SDX15D4-A||`-`||||89.10mV||90.00mV|90.90mV| |-|-||SDX15A2|0 psia to 15 psia||30 psia|86.85mV||90.00mV|93.15mV| |-|-||SDX15A4||||86.85mV||90.00mV|93.15mV| |-|-||SDX15A2-A||||89.10mV||90.00mV|90.90mV| |-|-||SDX15A4-A||||89.10mV||90.00mV|90.90mV| |SDX30G2|SDX30D4||`-`|0 psid to 30 psid||60 psid|86.85mV||90.00mV|93.15mV| |SDX30G2-A|SDX30D4-A||`-`||||89.10mV||90.00mV|90.90mV| |`-`|`-`||SDX30A2|0 psia to 30 psia||60 psia|86.85mV||90.00mV|93.15mV| |`-`|`-`||SDX30A4||||86.85mV||90.00mV|93.15mV| |`-`|`-`||SDX30A2-A||||89.10mV||90.00mV|90.90mV| |`-`|`-`||SDX30A4-A||||89.10mV||90.00mV|90.90mV| |SDX100G2|SDX100D4||`-`|0 psid to 100<br>psid||150 psid|96.50mV||100.00mV|103.5mV| |SDX100G2-A|SDX100D4-A||`-`||||99.00mV||100.00mV|101.0mV| |`-`|`-`||SDX100A2|0 psia to 100<br>psia||150 psia|96.50mV||100.00mV|103.5mV| |`-`|`-`||SDX100A4||||96.50mV||100.00mV|103.5mV| |`-`|`-`||SDX100A2-A||||99.00mV||100.00mV|101.0mV| |`-`|`-`||SDX100A4-A||||99.00 mV||100.00 mV|101.0 mV| |**Nomenclature**|||**Pressure Connection**<br>**(See Fig. 2)**|||**Pressure Type**|||**Grade**|| |G2|||A2/G2|||gage|||standard commercial|| |G2-A|||A2/G2|||gage|||prime|| |D4|||OK|||differential|||standard commercial|| |D4-A|||OK|||differential|||prime|| |A2|||A2/G2|||absolute|||standard commercial|| |A2-A|||A2/G2|||absolute|||prime|| |A4|||A4|||absolute|||standard commercial|| |A4-A|||A4|||absolute|||prime|| **Table 2. General Specifications (Maximum)** |**Table 2. General Specifications(Maximum)**|| |---|---| |**Characteristic**|**Parameter **| |Supplyvoltage (VS)|20Vdc| |Common mode pressure|150 psig| |Lead solderingtemperature(2 s to 4 s)|250 °C[482°F]| **Table 3. Environmental Specifications (Maximum)** |**Characteristic**|**Parameter **| |---|---| |Compensated operating temperature|0°C to 50°C [32°Fto122°F]| |Operating temperature|-40°C to 85°C [-40 °Fto185 °F]| |Storagetemperature|-55°Cto125°C [-67°F to257°F]| |Humiditylimits|0% RH to 100% RH| 2 www.honeywell.com/sensing ## Plastic Silicon Pressure Sensors, Low Cost, Temperature Compensated, DIP, 0 psi to 1 psi, 0 psi to 100 psi ## **Table 4. Performance Characteristics(** 3) |**Table 4. Performance Characteristics(**<br>**(**3)||||| |---|---|---|---|---| |**Characteristic**|**Min.**|**Typ. **|**Max.**|**Unit**| |Zero pressure offset<br>Zero pressure offset (prime grade)<br>(4)|-1.0<br>-0.3|0.0<br>0.0|+1.0<br>0.3|mV<br>mV| |Combined linearity and hysteresis<br>(5)<br>Combinedlinearity andhysteresis (prime grade)<br>(5) (13)|–<br>–|±0.2<br>±0.1|±1.0<br>±0.25|% FSO<br>%FSO| |Temperature effect on span, 0 °C to 50 °C [32°F to 122°F]<br>(6)<br>Temperature effectonspan, 0°Cto 50°C [32°F to122°F]<br>(6)(prime grade)|–<br>–|±0.4<br>±0.4|±2.0<br>±1.0|% FSO<br>%FSO| |Temperature effect on offset 0, °C to 50 °C [32°F to 122°F]<br>(6)<br>Temperature effect onoffset 0,°C to 50°C [32°Fto122°F]<br>(6) (prime grade)|–<br>–|±0.2<br>±0.2|±1.0<br>±0.5|mV<br>mV| |Repeatability<br>(7)|–|±0.2|±0.5|%FSO| |Input resistance<br>(8)|–|4.0|–|kOhm| |Outputresistance<br>(9)|–|4.0|–|kOhm| |Common modevoltage<br>(10)|1.5|3.0|5.0|Vdc| |Responsetime<br>(11)|–|100|–|µs| |Longterm stabilityof offset and span<br>(12)|–|±0.1|–|mV| **Notes:** 1. Full-Scale Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Full-Scale Span is ratiometric to the supply voltage. 2. Maximum pressure above which causes permanent sensor failure. 3. Reference conditions: - **T** - • **A**[= 25 °C (unless otherwise noted). ] - Supply VS = 12 Vdc, Common Mode Line pressure = 0 psig. - Pressure applied to Port B. For absolute devices only, pressure is applied to Port A and the output polarity is reversed. - 4. Maximum zero pressure offset for absolute devices is ±500 mV. 5. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. 6. Maximum error band of the offset voltage and the error band of the span, relative to the 25 °C [77 °F] reading. 7. Maximum difference in output at any pressure within the operating pressure range and the temperature within 0 °C to 50 °C [32 °F to 122 °F] after: - 100 temperature cycles, 0 °C to 50 °C [32 °F to 122 °F]. - 1.0 million pressure cycles, 0 psi to full-scale span. 8. Input resistance is the resistance between V **S** and ground. 9. Output resistance is the resistance between the + and - outputs. 10. Common Mode voltage of the output arms for V **S** =12 Vdc. 11. Response time for a 0 psi to Full-Scale Span pressure step change, 10% to 90% rise time. 12. Long term stability over a one-year period. 13. Maximum combined linearity and hysteresis for the SDX05 prime grade is ±0.5%. ## **Figure 1. Electrical Connections** Honeywell Sensing and Control 3 **Figure 2. Mounting Dimensions (For Reference Only. mm/[in])** **==> picture [76 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> A2/G2 Package<br>**----- End of picture text -----**<br> ## **A4 Package** - **D4 Package** ## **[WARNING ]** ## **PERSONAL INJURY** DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. **Failure to comply with these instructions could result in death or serious injury.** ## **WARRANTY/REMEDY** Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. **The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.** ## **[WARNING ]** ## **MISUSE OF DOCUMENTATION** - The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. - Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. **Failure to comply with these instructions could result in death or serious injury.** ## **SALES AND SERVICE** Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: ## **E-mail:** info.sc@honeywell.com **Internet:** www.honeywell.com/sensing ## **Phone and Fax:** While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Asia Pacific +65 6355-2828; +65 6445-3033 Fax Europe +44 (0) 1698 481481; +44 (0) 1698 481676 Fax Latin America +1-305-805-8188; +1-305-883-8257 Fax USA/Canada +1-800-537-6945; +1-815-235-6847 +1-815-235-6545 Fax Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. ## Sensing and Control ## Honeywell 1985 Douglas Drive North Golden Valley, Minnesota 55422 **www.honeywell.com/sensing** 008103-3-EN IL50 GLO Printed in USA November 2008 Copyright © 2008 Honeywell International Inc. All rights reserved.
Updated at February 9, 2023
Honeywell is a globally recognized leader in the design and manufacture of advanced sensing and switching solutions. Renowned for engineering components that deliver enhanced precision and ruggedness, Honeywell provides essential technologies for demanding applications across critical healthcare, aerospace, and industrial equipment. With a comprehensive portfolio built to address both basic and complex design challenges, the company stands at the forefront of reliable electronic component manufacturing. The core of our Honeywell offering is an extensive selection of high-performance sensors and transducers. This includes a robust lineup of pressure sensors and transducers engineered for accurate fluid and gas measurement in challenging environments. Furthermore, we provide a wide array of temperature sensors and specialized temperature sensing NTC thermistors designed for stable thermal management, alongside precision current sensors and load cells that deliver critical feedback for control systems. Beyond advanced sensing technology, Honeywell’s expertise extends to essential circuit protection and electromechanical components. Our selection encompasses power relays, thermal magnetic circuit breakers, and standard terminal blocks, ensuring safe and efficient power distribution. Whether integrating core components or sourcing specialized accessories, design engineers can rely on Honeywell for uncompromising quality and operational excellence.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →