- Manufacturer: SOLAHD
- Product type:
- Power Supply Applications:ITE; No. of Outputs:1 Output; Output Power Max:960W; Output Voltage - Output 1:24VDC; Output Current - Output 1:40A; Output 73R7416
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1112.73 € |
| Current stock | 10+ |
| Lead time | 30 days |
**4**
**Power Supplies**
## **SDN™ Performance DIN Rail Series**
The SDN DIN Rail power supplies provide industry leading performance. Sag immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications. Power factor correction to meet European directive, hazardous location approvals and optional redundant accessories allow the SDN series to be used in a wide variety of applications. Wide operation temperature range, high tolerance to shock and vibration and reliable design make the SDN series the definition of DC power quality.
## **Features**
- Power Factor Correction (per EN61000-3-2)
- Auto Select 115/230 VAC, 50/60 Hz Input
**==> picture [136 x 27] intentionally omitted <==**
**----- Start of picture text -----**<br>
UL 508 Listed UL 60950 EMC and<br>IND. CONT. EQ. E137632 Low Volt.<br>E61379 CUL/CSA-C22.2 Directive<br>No. 234-M90<br>**----- End of picture text -----**<br>
- Single Phase models meet SEMI F47 Sag Immunity
- Class 1, Div 2 Hazardous Locations
- Improved metal mounting clip
- DC OK Signal
- Adjustable Voltage
- SDN10-24-100P New Compact width (3.26”)
## **Related Products**
- SDP™ Series
- SFL Series
- SCP Series
- SCL Series
- Parallel Capability standard on all units
- Industrial grade design
- 10°C to 60°C operation without derating. Indefinite short circuit, overvoltage and overtemperature protection.
- Powers high inrush loads without shutdown or foldback
- Rugged metal case and DIN connector
- SDN2.5-24-100P and SDN4-24-100LP meet NEC Class 2
- Narrow width on rail for space critical applications
- User-friendly front panel
- Large, rugged, accessible, multiple connection screw terminations
- Easy installation
- application – 2.5 A through 40 A
## **Applications**
- Industrial/Machine control
- Process control
- Conveying Equipment
- Material Handling
- Vending Machines
- Packaging Equipment
- DeviceNet[TM]
- Amusement Park Equipment
- Semiconductor Fabrication Equipment
## **Accessories**
- Chassis Mount Bracket (SDN-PMBRK2)
- Single and three phase inputs available
- High MTBF and reliability
- Five year warranty
- Patented
Visit our website at www.solaheviduty.com or contact **Technical Services** at **(800) 377-4384** with any questions.
**80**
**4**
## **Power Supplies**
## **The Sola Difference**
**==> picture [495 x 611] intentionally omitted <==**
**----- Start of picture text -----**<br>
Strong all metal<br>DIN connector<br>for horizontal or<br>vertical mounting<br>Rugged metal packaging<br>Large, heavy-duty screw<br>- —— terminals for #10 AWG/4 mm [2] ,<br>for quick, easy installation<br>Multiple output ih ——— SS<br>connections<br>———— \<br>for ease of wiring<br>multiple devices<br>1O.B.SB.B.4 a WoNOHW. DC OK Signal<br>Single or parallel use<br>\<br>selectable by user<br>Easy to use, clearly Adjustable<br>labeled front panel output voltage<br>No internal fan, no extra<br>cooling required in any<br>power level<br>UL508 listing<br>means no derating<br>in UL 508 systems<br>NN IND.CONT.EQ.18WM<br>Full CE compliance for<br>eQnus LISTED C € —_.<br>115/230 VAC 1.3-0.7A 50/60 HZ safety, emissions and<br>ingress protection<br>: r 1<br>| [oo KW, H<br>Automatically adjusts for<br>either 115 or 230V, 50 or Narrow width for minimal<br>60 Hz Input. No manual panel space required<br>intervention required.<br>**----- End of picture text -----**<br>
Visit our website at www.solaheviduty.com or Contact **Technical Services** at **(800) 377-4384** with any questions.
**81**
**4**
## **Power Supplies**
##
|**Description**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|---|---|---|---|---|---|
||**SDN 2.5-24-100P**|**SDN 4-24-100LP**|**SDN 5-24-100P**|**SDN 10-24-100P**|**SDN 20-24-100P**|
|**Input**||||||
|**Nominal Voltage**|115/230 VAC auto select|||||
|**- AC Range**|85-132/176-264 VAC|||||
|**- DC Range**|90-375 VDC|210-375 VDC|||N/A|
|**- Frequency**|47 - 63 Hz|||||
|**Nominal Current1**|1.3 A / 0.7 A|1.8 A / 0.9 A|2.2 A / 1.0 A|5 A / 2 A typ.|9 A/ 3.9 A|
|**- Inrush current max.**|typ. < 25 A|typ. < 20 A||typ. < 40 A||
|**Efficiency (Losses2)**|> 87.5% typ (8.6 W)|> 88% typ (13.1 W)|> 88% typ (16.4 W)|> 88% typ (32.7 W)|> 90% typ (48 W)|
|**Power Factor Correction**|Units Fulfill EN61000-3-2|||||
|**Output**||||||
|**Nominal Voltage**|24 VDC (22.5 - 28.5 VDC adj.)|||||
|**- Tolerance**|< ±2% overall (combination Line, load, time and temperature related changes)|||||
|**- Ripple3**|< 50 mVpp|||||
|**Nominal Current**|2.5 A (60 W)|3.8 A (92 W)|5 A (120 W)|10 A (240 W)|20 A (480 W)|
|**- Peak Current4**|2x Nominal Current<br>< 2 sec.|4.2 A max|6 A<br>2x Nominal Current<br>< 2 sec.|12 A<br>2x Nominal Current<br>< 2 sec.|25 A<br>2x Nominal Current<br>< 2 sec.|
|**-Current Limit**|Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current)|||||
|**Holdup Time5**|> 50 ms|> 110 ms|> 100 ms||> 20 ms|
|**Parallel Operation**|Single or Parallel use is selectable via Front Panel.|||||
|**General**||||||
|**EMC**<br>**- Emissions**||||||
||EN50081-1,-2 Class B EN55011, EN55022 Radiated and Conducted including Annex A.|||||
|**- Immunity**|EN50082-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation Class 4,<br>EN61000-4-11; Transient resistance according to VDE 0160/W2 over entire load range.|||||
|**Approvals**|EN60950; EN50178; EN60204; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC). EN61000-3-2, IEC60079-15 (Class 1, Zone 2, Hazardous<br>Location, Groups A, B, C, D w/ T3A temp class up to 60°C Ambient.) SEMI F47 Sag Immunity. SDN2.5 & SDN4 - UL60950 testing to include approval as<br>NEC Class 2 power supply acc. to NFPA 70 art. 725-41 (a)(2).|||||
|**Temperature**|Storage: -25°C...+85°C Operation. -10°C...+60°C full power with operation to 70°C possible with a linear derating to half power from 60°C to 70°C (Convection cooling,<br>no forced air required). Operation up to 50% load permissable with sideways or front side up mounting orientation. The relative humidity is < 90% RH, noncondensing;<br>IEC 68-2-2, 68-2-3. For operation below -10°C, contact Technical Services.|||||
|**Warranty**|5 years|||||
|**General Protection/**<br>**Safety**|Protected against continuous short-circuit, overload, open-circuit. Overvoltage protection (OVP) for output set > 30.5 but < 33 VDC, Auto Recovery.<br>Protection class 1 (IEC536), degree of protection IP20 (IEC 529) Safe low voltage: SELV (acc.EN60950)|||||
|**Status Indicators**|Green LED and DC OK signal (N.O. Contact rated 300 mA @ 60 VDC)|||||
|**Installation**||||||
|**Fusing**<br>**- Input**|Internally fused. External 10 A slow acting fusing for the input is recommended for SDN2.5, 4, 5 and 10P models.<br>A 16 A slow acting fuse or time-delay circuit breaker is recommended for the SDN20 model.|||||
|**- Output**|Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal O/P<br>current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping.|||||
|**Mounting**|Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required).|||||
|**Connections**|Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for stranded conductors.<br>Output: Two connectors per output, connector size range: 16-10 AWG (1.5 - 6 mm2) for solid conductors.|||||
|**Case**|Fully enclosed metal housing with fine ventilation grid to keep out small parts.|||||
|**- Free Space**|25 mm above and below<br>25 mm left and right 10 mm in front||25 mm above and below<br>25 mm left and right<br>15 mm in front|70 mm above and below<br>25 mm left and right 15 mm in front||
|**H x W x D**|4.88 in x 1.97 in x 4.55 in<br>(124 mm x 50 mm x 116 mm)|4.88 in x 2.56 in x 4.55 in<br>(124 mm x 65 mm x 116 mm)||4.88 in x 3.26 in x 4.55 in<br>(124 mm x 83 mm x 116 mm)|4.88 in x 6.88 in x 4.55 in<br>(124 mm x 175 mm x 116 mm)|
|**Weight (lbs/g)**|1.6 lb (725g)|2.4 lbs (1055g)||3.3 lbs (1480g)|3 lbs (1520g)|
1
2 Losses are heat dissipation in watts at full load, nominal input line.
3 Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
4 All peak current is calculated at 24 Volt levels.
5 Full load, 100 VAC Input @ Tamb = +25°C
Visit our website at www.solaheviduty.com or contact **Technical Services** at **(800) 377-4384** with any questions.
**82**
**4**
**Power Supplies**
##
|**Description**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|---|---|---|---|---|---|
||**SDN 5-24-480**|**SDN 10-24-480**|**SDN 20-24-480C**|**SDN 30-24-480**|**SDN 40-24-480**|
|**Input**||||||
|**Nominal Voltage**|1Ø or 3Ø, 380 - 480 VAC1|||3Ø 380 - 480 VAC||
|**-AC Range**|340 - 576 VAC|||||
|**-DC Range**|450 - 820 VDC|||||
|**-Frequency**|47 - 63 Hz|||||
|**Nominal Current2**|0.4 A|0.8 A|1.5 A|2.0 A|3.0 A|
|**-Inrush current max.**|typ. < 17 A|typ. < 15 A|typ. < 7 A|typ. < 30 A||
|**Efficiency (Losses3)**|> 90% typ (12 W)|> 90% typ (26.7 W)|> 90% typ (48 W)|> 90% typ (72 W)|> 90% typ (96 W)|
|**Power Factor Correction**|Units Fulfill EN61000-3-2|||||
|**Output**||||||
|**Nominal Voltage**|24 VDC (22.5 - 28.5 VDC adj.)|||||
|**-Tolerance**|< ±2% overall (combination Line, load, time and temperature related changes)|||||
|**-Ripple4**|< 50 mVpp|||||
|**Nominal Current**|5 A (120 W)|10 A (240 W)|20 A (480 W)|30 A (720 W)|40 A (960 W)|
|**-Peak Current**|6 A<br>2x Nominal Current<br>< 2 sec.|12 A<br>2x Nominal Current<br>< 2 sec.|25 A<br>2x Nominal Current<br>< 2 sec.|35 A<br>2x Nominal Current<br>< 2 sec.|45 A<br>2x Nominal Current<br>< 2 sec.|
|**-Current Limit**|Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current)|||||
|**Holdup Time**|> 20 ms|||||
|**Parallel Operation**|10A, 20A, 30A parallel/single user selectable. 40A contains active current balancing via single wire connection.|||||
|**General**||||||
|**EMC**||||||
|**-Emissions**|EN50081-1,-2 Class B EN55011, EN55022 Radiated and Conducted including Annex A.|||||
|**-Immunity**|EN50082-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation<br>Class 4, EN61000-4-11; Transient resistance according to VDE 0160/W2 over entire load range.|||||
|**Approvals**|CB Scheme, EN60950; EN50178; EN60204; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC). EN61000-3-2, IEC 60079-15<br>Class 1, Zone 2 hazardous location, Groups IIA, IIB, IIC w/T3 temp class up to 60°C Ambient.|||||
|**Temperature**|Storage: -25°C...+85°C Operation. -10°C...60°C full power with operation to 70°C possible with a linear derating to half power from 60°C to 70°C<br>(Convection cooling, no forced air required). Operation up to 50% load permissable with sideways or front side up mounting orientation. The relative<br>humidity is < 90% RH, noncondensing; IEC 68-2-2, 68-2-3.|||||
|**Warranty**|5 years|||||
|**General Protection/**<br>**Safety**|Protected against continuous short-circuit, overload, open-circuit. Overvoltage protection (OVP) for output set > 30.5 but < 33 VDC, Auto Recovery.<br>Protection class 1 (IEC536), degree of protection IP20 (IEC 529) Safe low voltage: SELV (acc.EN60950)|||||
|**Status Indicators**|Green LED on when Vout= 18V or greater.|||||
|**Installation**||||||
|**Fusing**||||||
|**-Input**|Internally fused.|||||
|**-Output**|Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x<br>Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping.|||||
|**Mounting**|Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required).|||||
|**Connections**|Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for stranded conductors.<br>Output: Two connectors per output, connector size range: 16-10 AWG (1.5 - 6 mm2) for solid conductors.|||||
|**Case**|Fully enclosed metal housing with fine ventilation grid to keep out small parts.|||||
|**-Free Space**|25 mm above and below<br>25 mm left and right<br>15 mm in front||70 mm above and below<br>25 mm left and right<br>15 mm in front|||
|**H x W x D**<br>**in (mm)**|4.88 in x 2.91 in x 4.55 in<br>(124 mm x 73 mm x 116 mm)|4.88 in x 3.5 in x 4.55 in<br>(124 mm x 89 mm x 116 mm)|4.88 in x 5.9 in x 4.55 in<br>(124 mm x 150 mm x 116 mm)|4.88 in x 9.72 in x 4.55 in<br>(124 mm x 247 mm x 116 mm)|4.88 in x 11.1 in x 4.55 in<br>(124 mm x 282 mm x 116 mm)|
|**Weight (lbs/g)**|1.7 lbs (730g)|2.16 lbs (980g)|3.97 lbs (1800g)|4 lbs (2000g)|6.6 lbs (3300g)|
1 For the SDN20-24-480C, single phase input is permissible but output is derated to 75% (15 Amps @ 24 VDC).
2
3 Losses are heat dissipation in watts at full load, nominal input line.
4 Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
Visit our website at www.solaheviduty.com or Contact **Technical Services** at **(800) 377-4384** with any questions.
**83**
**4**
**Power Supplies**
## **SDN™ Series Dimensions**
|**Catalog Number**|**Dimensions - inches(mm)**|**Dimensions - inches(mm)**|**Dimensions - inches(mm)**|
|---|---|---|---|
||**H**|**W**|**D**|
|SDN 2.5-24-100P|4.88(124)|1.97(50)|4.55(116)|
|SDN 4-24-100LP|4.88(124)|2.56(65)|4.55(116)|
|SDN 5-24-100P|4.88(124)|2.56(65)|4.55(116)|
|SDN 5-24-480|4.88(124)|2.91(73)|4.55(116)|
|SDN 10-24-100P|4.88(124)|3.26(83)|4.55(116)|
|**Catalog Number**|**Dimensions - inches(mm)**|**Dimensions - inches(mm)**|**Dimensions - inches(mm)**|
|---|---|---|---|
||**H**|**W**|**D**|
|SDN 20-24-100P|4.88(124)|6.88(175)|4.55(116)|
|SDN 10-24-480|4.88(124)|3.50(89)|4.55(116)|
|SDN 20-24-480C|4.88(124)|5.90(150)|4.55(116)|
|SDN 30-24-480|4.88(124)|9.72(247)|4.55(116)|
|SDN 40-24-480|4.88(124)|11.10(282)|4.55(116)|
Visit our website at www.solaheviduty.com or contact **Technical Services** at **(800) 377-4384** with any questions.
**84**
**4**
**Power Supplies**
## **SDN™ Series Mounting**
## **DIN Rail Mounting**
Snap on the DIN Rail:
1. Tilt unit slightly backwards
2. Put it onto the DIN Rail
3. Push downwards until stopped
4. Push at the lower front edge to lock
5. Shake the unit slightly to ensure that the retainer has locked
Alternative Screwing-on: Using the optional SDN-PMBRK2 accessory, the unit can also be screwed onto plane surfaces (without DIN Rail).
Detachment from DIN Rail:
## **Chassis Mounting**
Press button downwards (to unlock) and remove the unit from the DIN Rail.
## **Dimensions**
Instead of snapping a Sola SDN™ unit on the DIN Rail, you can also screw it on by means of the screw mounting set SDN-PMBRK2.
the existing two profiles at the back of the unit.
## **Note:**
You need one SDN-PMBRK2 per unit.
- In addition, two screws are required per SDN-PMBRK2
- (e.g. M3 x 12), which are not included with the set.
##
- a. At the unit:
1. Remove the screw from the profile.
- outwards
- to remove.
- b. Push the
- SDN-PMBRK2 profile into the groove as far as possible. Secure with
screw.
_For SDN5-24-100P and above models_
## **Note the orientation:**
_groove only as shown here._
_For SDN2.5-24-100P Model_
Visit our website at www.solaheviduty.com or Contact **Technical Services** at **(800) 377-4384** with any questions.
**85**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →